8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen
Filtern
Dokumenttyp
- Vortrag (186)
- Zeitschriftenartikel (109)
- Beitrag zu einem Tagungsband (87)
- Posterpräsentation (64)
- Sonstiges (9)
- Buchkapitel (8)
- Forschungsdatensatz (8)
- Forschungsbericht (4)
- Beitrag zu einem Sammelband (3)
- Dissertation (2)
Sprache
- Englisch (355)
- Deutsch (125)
- Mehrsprachig (1)
Schlagworte
- Concrete (101)
- Ultrasound (87)
- LIBS (63)
- Monitoring (53)
- Non-destructive testing (38)
- Beton (29)
- Zerstörungsfreie Prüfung (29)
- Ultraschall (28)
- NDT (26)
- Coda wave interferometry (21)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (481) (entfernen)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (186)
Ultrasonic Coda Wave interferometry has the potential to detect minute changes in scattering materials like concrete. By permanently installing ultrasonic transducers in concrete, DFG Research unit CoDA aims to develop methods for concrete damage assessment in Germany's aging infrastructure. To test the methods developed in simulations and laboratory experiments on a large scale, we have implemented several ultrasonic transducers at the Gänstorbrücke Ulm, one of Germany's most monitored road bridges. Since fall 2020 we are monitoring parts of the center of the Bridge, as well as an abutment, and compare the results to the commercial monitoring system. All data is recorded with a self-made data collection device, the so-called W-Box, and analyzed with different coda wave-based algorithms to detect signal and volumetric velocity changes. The long-term measurements show that the influence of temperature changes on strains and therefore ultrasound velocity changes calculated with coda waves can be monitored. The capabilities and limitations of the coda wave-based monitoring system are tested in a controlled experiment. Static loading using a truck with varying loads at several positions allows the calibration of the system to improve the detectability of possibly damaging loads and changes induced by this loading. A map of velocity change analyzing data from this load experiment shows that the influence of load on the material and strain distribution can be detected with array measurements.
Hydration is the exothermic reaction between anhydrous cement and water, which forms the solid cement matrix of concrete. Being able to evaluate the hydration is of high interest for the use of both conventional and more climate-friendly building materials. The experimental monitoring is based on temperature or moisture measurements. The first needs adiabatic conditions, which can only be achieved in laboratory. The latter is often measured comparing the weight of the material sample before and after oven drying, which is time-consuming. This study investigates the moisture content of two cement-based and two calcium sulphate based mixtures for the first 90 days by using the calcium carbide method and oven drying at 40 °C and 105 °C (Darr method). Thereby, the amount of chemically bound water is determined to derive the degree of hydration. The calcium carbide measurements highly coincide with oven drying at 40 °C. The calcium carbide method is therefore evaluated as a suitable alternative to the time-consuming Darr drying. The prompt results are seen as a remarkable advantage and can be obtained easily in laboratory as well as in the field.
According to the NBI database, more than 21,000 in-service U.S. bridges lack sufficient structural documentation necessary for analytical load rating. Among these are a significant proportion of older prestressed concrete bridges. Given the lack of documentation on the reinforcing layout, such structures cannot be load rated analytically and are often subject to engineering judgement as the basis for rating. Otherwise, the typical approach for load rating such bridges is to conduct costly proof load testing and destructive probing together with making conservative assumptions. Therefore, any improvement to current practices will benefit DOTs and taxpayers alike. Accurately reconstructed 3D images of the girders to reflect the internal reinforcement could mitigate the need for costly, if not impractical, destructive testing and proof load testing, and help reduce dependency on conservative assumptions. This study examines a comprehensive NDE approach using ultrasonic tomography and GPR to aid in gathering structural information for load rating purposes. Different types of AASHTO and hollow core girders were tested.
The Infrastar training school provides lectures and hands-on training to Master and PhD students, early-stage researchers and (young) professionals on all aspects of asset management of civil infrastructures with respect to fatigue of materials. It is organized yearly since 2019 and up to 20 profiles are selected to attend the 3.5-day training.
A team of 7 teachers provides insight in multi-disciplinary and intersectoral basic concepts in three core fields, ranging from the design to the dismantling of the structures (bridges and wind turbines):
1. Monitoring and auscultation,
2. Structural and action models,
3. Reliability, risk and decision analyses.
Each year, a recognized expert is invited to deliver a keynote lecture to raise interest in a specific aspect of one of the fields covered. The presentation is recorded and published on the training school website.
Attenuation of ultrasonic signals in concrete has the potential to carry much information about the microstructure of the material. In this work a series of concrete specimens of varying porosities and pore size distributions were internally imaged with x-ray computed tomography (CT), and then subsequently examined with throughtransmission ultrasound. The CT images were used to quantify both capillary porosity of cement paste as well as internal interfaces that are likely to produce elastic wave scattering. Ultrasound signals were represented as a diffusion process such that absorption and scattering attenuation could be isolated. As implemented, the diffusion model was a poor predictor of capillary porosity, while diffusivity was a reasonable predictor of scattering interfaces. Diffusivity was found to scale extremely well with small scale porosity, which made it a good predictor of compressive strength.
The retroreflective corner echo is used, for example, in ultrasonic non-destructive testing of metals to find fatigue cracks in tubes or shafts. If the much weaker crack tip signal is additionally detected, the crack length can also be determined. A corner reflection occurs in cases of surface breaking cracks with predominantly perpendicular orientation to the surface. The intensity of the corner reflection depends on the angle of incidence and on the ultrasonic wave mode used. For the reliable detection of vertical surface breaking cracks in metals, transversal waves are commonly used, which propagate at an angle of 37° to 53° to the inspection surface. As shown in this contribution, the wide spread low frequency ultrasonic arrays with dry point contact sources available for ultrasonic testing of concrete also allow to receive corner echoes. These devices generate transversal waves in concrete structures with a large divergence of the sound field. A series of experiments was carried out with such dry point contact arrays on concrete specimens with artificial test defects and controlled induced cracks of different depths. The ultrasonic time-of-flight signals were recorded, exported and reconstructed utilising the SAFT (Synthetic Aperture Focusing Technique) algorithm. The SAFT reconstruction parameters were adjusted to visualize the corner echo indication. As will be shown, with this targeted processing, the reproducible detection of surface breaking cracks in concrete is possible. The retroreflective corner echo can thus be exploited in civil engineering for non-destructive inspection of concrete.
Muon tomography applied to assessment of concrete structures: First experiments and simulations.
(2022)
Non-destructive techniques for reinforced or prestressed concrete inspection such as ultrasound or radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features. Until the 1980s X-ray transmission was used in case of special demands and showed a much better resolution than other NDT techniques. However, due to safety concerns and cost issues, this method is almost never used anymore. Muon tomography has received much attention recently. Novel detectors for cosmic muons and tomographic imaging algorithms have opened new fields of application. As a first step towards practical application in civil engineering and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results are at least of similar quality compared to ultrasonic and radar imaging, potentially even better. In a second step, we have performed simulations to assess the potential for a set of important testing problems such as grouting defects in tendon ducts. The next steps include the development of mobile detectors and optimizing acquisition and imaging parameters.
This presentation summarizes the opbjectives and the progress of the EURATOM project PREDIS (pre-disposal management of radioactive waste) and its workpackage 7 in particular. Focus is on the development of wireless sensors for monitoring radioactive waste packages, measuring radiation, temperature, pressure and humidity.
This contribution summarizes actual developments and draft fundamental teaching topics in the field of nondestructive testing in civil engineering (NDT-CE). It is based on the first memorandum on teaching and research in the field of NDT-CE at German speaking universities and provides an overview of the academic education and highlights possible focuses, especially in teaching but also takes into account noteworthy developments and topics in research in the field of NDT-CE.
Suggestions are given for the development and advancement of the teaching curricula in regards to a comprehensive and sound professional education of students in civil engineering and adjacent disciplines.
The Infrastar training school provides lectures and hands-on training to Master and PhD students, early-stage researchers and (young) professionals on all aspects of asset management of civil infrastructures with respect to fatigue of materials. It is organized yearly since 2019 and up to 20 profiles are selected to attend the 3.5-day training.
A team of 7 teachers provides insight in multi-disciplinary and intersectoral basic concepts in three core fields, ranging from the design to the dismantling of the structures (bridges and wind turbines):
1. Monitoring and auscultation,
2. Structural and action models,
3. Reliability, risk and decision analyses.
Each year, a recognized expert is invited to deliver a keynote lecture to raise interest in a specific aspect of one of the fields covered. The presentation is recorded and published on the training school website.
Concrete structures are invaluable assets to a society and managing them efficiently and effectively can be supported by information gathered through structural health monitoring (SHM). In this paper, a combined approach based on passive, i.e., acoustic emission (AE), and active, i.e., ultrasonic stress wave (USW) monitoring techniques for application to concrete structures is proposed and evaluated. While AE and USW are based on the same underlying physics, i.e., wave motion in solids, they differ fundamentally with respect to the nature of the source. For the former, external stimuli such as mechanical loads or temperature cause the rapid release of energy from initially unknown locations. As a result, AE events are unique and cannot be repeated. For the latter, a known source at a known location is employed at a specified time. This approach is thus controlled and repeatable. It is
argued that a combination of these two techniques has the potential to provide a more comprehensive picture of ongoing fracture processes, damage progression, as well as slowly occurring aging and degradation mechanisms.
This combined approach does thus promise new opportunities to support condition assessment of concrete structures. After providing an overview and comparison of the two techniques, results, and observations from a full-scale laboratory experiment and an in-service bridge monitoring study are discussed to demonstrate the promise of the proposed combined monitoring approach. Finally, suggestions for further work are presented.
Muon tomography applied to assessment of concrete structures: First experiments and simulations.
(2022)
Non-destructive techniques for reinforced or prestressed concrete inspection such as ultrasound or radar have found regular, successful practical application but sometimes suffer from limited resolution and
accuracy, imaging artefacts or restrictions in detecting certain features. Until the 1980s X-ray transmission was used in case of special demands and showed a much better resolution than other NDT techniques.
However, due to safety concerns and cost issues, this method is almost never used anymore. Muon tomography has received much attention recently. Novel detectors for cosmic muons and tomographic imaging algorithms have opened new fields of application. As a first step towards practical application in civil engineering and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results are at least of similar quality compared to ultrasonic and radar imaging, potentially even better. In a second step, we have performed simulations to assess the potential for a set of important testing problems such as grouting defects in tendon ducts. The next steps include the development of mobile detectors and optimizing acquisition and imaging parameters.
Engineered barriers are a key element to enable safe nuclear waste disposal. One method currently under research for their construction is magnesia concrete applied in a shotcrete procedure. In this study, the ultrasonic echo method is evaluated as a means for quality assurance. Imaging of internal structures (backwall, boreholes) and defects, such as delamination, has successfully been achieved in the shotcrete. Additionally, detailed information about the potential cause of selected reflectors are obtained by phase analysis. In several test blocks of various sizes, no consistent concrete section boundaries have been found by ultrasonic imaging, which was verified by subsequent drilling and complementary tests. An experiment with artificial defects imitating cracks, air-filled voids, and material with lower density has been challenging and shows the limitations of the current methods. Although significant defects, such as a large delamination, are reliably identified, several smaller defects are not identified. Generally, ultrasonic imaging provides a suitable base as a mean for quality assurance during and after the construction of sealing structures. However, further developments are required to enhance the reliability of the method and a full validation is still pending. Still, the method has potential to increase the safety of nuclear waste repositories.
To complement the information provided by deterministic seismic imaging at length scales above a certain resolution limit we present the first application of adjoint envelope tomography (AET) to experimental data. AET uses the full envelopes of seismic records including scattered coda waves to obtain information about the distribution of absorption and small-scale heterogeneity which provide complementary information about the investigated medium. Being below the resolution limit this small-scale structure cannot be resolved by conventional tomography but still affects wave propagation by attenuating ballistic waves and generating scattered waves. Using ultrasound data from embedded sensors in a meter-sized concrete specimen we image the distribution of absorption and heterogeneity expressed by the intrinsic quality factor Q−1 and the fluctuation strength ɛ that characterizes the strength of the heterogeneity. The forward problem is solved by modeling the 2-D multiple nonisotropic scattering in an acoustic medium with spatially variable heterogeneity and attenuation using the Monte-Carlo method. Gradients for the model updates are obtained by convolution with the back-propagated envelope misfit using the adjoint formalism in analogy to full waveform inversion.
We use a late coda time window to invert for absorption and an earlier time window to infer the distribution of heterogeneity. The results successfully locate an area of salt oncrete with increased scattering and concentric anomalies of intrinsic attenuation. The resolution test shows that the recovered anomalies constitute reasonable representations of internal structure of the specimen.
Der Weg zur digitalen Brücke ist eingeschlagen. Im Bereich der Planung, Bauüberwachung und -ausführung wird aktuell das Building Information Modelling (BIM) eingeführt. Ist eine Brücke in der Baulast von Bund und Ländern errichtet, wird ihr Zustand im Zuge von wiederkehrenden Bauwerksprüfungen nach DIN 1076 lückenlos überwacht. Abgespeichert werden die Informationen der Überwachung in einer Datenbank (ASB-ING Teilsystem Bauwerksdaten). Aus dieser Datenbank können anschließend relevante Informationen in ein objektspezifisches Bauwerksbuch überführt werden. In dieser Datenbank werden im Vorfeld definierte Daten abgespeichert. Reine Messdaten oder aber auch die verwendeten ingenieurtechnisch-physikalischen Modelle verbleiben in der Regel bei den beauftragen Dienstleistern. Zusammengefasst existieren verschiedene parallele Insellösungen der Informationsablage. Gegenstand verschiedener Forschungsanstrengungen ist es nun Lösungen zu finden, die einen ganzheitlichen Ansatz für den Informationsfluss von der Errichtung über den Betrieb bis hin zum Abbruch eines Bauwerkes sicherstellen. Im Rahmen einer prototypischen Entwicklung wird auf Grundlage, des für die Industrie 4.0 entwickelten open source Software Framework Eclipse BaSyx, ein möglicher Lösungsansatz – die Verwaltungsschale BBox (Bridge Box) - präsentiert. Dieser Lösungsansatz stellt das physikalisch-ingenieurtechnische Modell zur Zustandsbewertung der Brücke gedanklich in den Mittelpunkt. Unter der Voraussetzung einer durchgängigen Digitalisierung der gesamten Prozessschritte innerhalb der Lebensdauer der Brücke, kann jeder Planungs- und Fertigungsschritt, die Instandhaltung einschließlich des Rückbaus erfasst werden. Das Besondere hierbei ist, dass auch die Grundlagen der Bewertung, wie Messdaten, mit abgespeichert werden. Die Modellstruktur der Verwaltungsschale erlaubt hierbei eine bedarfsgerechte Granularität hinsichtlich der Messdaten auf allen virtuellen Ebenen, um das physikalisch-ingenieurtechnisch Modell mit Daten zu versorgen. Die gewählte Form der Datenablage bildet den Grundstein für zukünftige KI-Auswertungen z.B. mit den Methoden des Maschinellen Lernens (ML). Der Zugriff auf die dafür jeweils benötigten Daten wird durch die Ablage der Daten einschließlich Metadaten und den Einsatz einer Standard S3 Schnittstelle stark vereinfacht. Der Beitrag stellt die Entwicklung und die Systemarchitektur der BBox am Beispiel von 2 Projekten dar.
To improve ultrasonic imaging of concrete structures, we transferred a seismic migration technique, the Reverse Time Migration (RTM), to non-destructive testing. A 2D elastic RTM algorithm was tested on synthetic ultrasonic echo data. Compared to the typically used synthetic aperture focusing technique (SAFT) as well as our acoustic RTM algorithm, the presented elastic RTM results show an enhancement in imaging vertical reflectors and complex features inside the 2D numerical concrete model.
The ultrasonic echo technique is widely used in non-destructive testing for investigation and damage analysis of concrete constructions. Important applications include thickness measurements, geometry determination, the localization and characterization of built-in components as well as the detection of quality issues (cracks, honeycombing, low concrete strength).
To improve ultrasonic data imaging of complicated structures in concrete, we transferred a seismic migration technique, the Reverse Time Migration (RTM), to non-destructive testing in civil engineering. In a preliminary study, we tested a 2D acoustic RTM algorithm on measured ultrasonic echo data acquired at a concrete foundation slab. Compared to the conventional used synthetic aperture focusing technique algorithms (SAFT) for ultrasonic data reconstruction, our acoustic RTM results showed a significant improvement in imaging the interior structure of the concrete slab. Vertical reflectors were reconstructed which was not possible by traditional imaging.
In contrast to SAFT, RTM is a wavefield-continuation method in time and uses the full wave equation. RTM is, thus, able to include multiple reflections and to handle multi-pathing as well as many other complex situations. As a drawback RTM requires extensive computing power and memory capacity. Nevertheless, due to progresses in parallel processing and other computational technologies RTM has become appealing for the application in the field of non-destructive testing.
An RTM algorithm, which uses the full elastic wave equation instead of the full acoustic one (as applied in our preliminary work) has the potential to optimize the imaging results even further. This is due to the fact, that our ultrasonic measurement data are generated by exciting elastic waves. Thus, in a first step, two 2D elastic RTM algorithms were tested on synthetic ultrasonic echo data generated with a concrete model consisting of several steps and circular shaped air inclusions. In addition, two imaging conditions were evaluated to reduce migration artifacts. Our synthetic elastic RTM results showed an enhancement in imaging the features inside the test model compared to acoustic RTM and SAFT. In a second step, we acquired ultrasonic measurement data at a concrete test specimen consisting of three steps and four air filled tendon ducts. The evaluation of the real data with our elastic RTM code was also successful and the reconstruction of the geometries of the steps and tendon ducts could be improved. With our study we have shown that elastic RTM is a step forward for ultrasonic testing in civil engineering.
Das Ultraschall-Echo-Verfahren ist eine klassische zerstörungsfreie Prüftechnik zur Geometriebestimmung sowie Schadensanalyse von Betonkonstruktionen. Um die Abbildung der Ultraschalldaten von komplexen Betonstrukturen zu verbessern, haben wir die Reverse-Time Migration (RTM) aus der Seismik auf die zerstörungsfreie Prüfung im Bauwesen übertragen. In einer Vorstudie haben wir einen 2D akustischen RTM Code verwendet und an realen Ultraschalldaten, die an einer Betonfundamentplatte aufgenommen wurden, getestet. Im Vergleich mit dem herkömmlichen Rekonstruktionsalgorithmus für Ultraschalldaten, der Synthetic Aperture Focusing Technique (SAFT), zeigten die akustischen RTM-Ergebnisse eine deutliche Verbesserung in der Abbildung der inneren Struktur der Betonfundamentplatte. Vertikale Reflektoren konnten rekonstruiert werden, was mit dem herkömmlichen Abbildungsverfahren nicht möglich war. RTM ist, im Gegensatz zu SAFT, eine wellengleichungsbasierte Migrationsmethode und beruht auf der numerischen Lösung der vollständigen Wellengleichung. Die Vorteile sind, dass der Algorithmus sämtliche Informationen des Wellenfeldes verwendet und daher verschiedene Welleneffekte wie z.B. Multipathing berücksichtigt werden können. Die RTM bietet damit die Möglichkeit auch stark geneigte Reflektoren sowie Streukörper mit komplexen Geometrien darzustellen. Ein Nachteil ist jedoch die lange Rechenzeit und der hohe Bedarf an Speicherkapazität. Ein RTM-Algorithmus, der die elastische Wellengleichung anstatt der akustischen verwendet (wie in unserer Vorstudie angewandt), hat das Potenzial, die Abbildungsergebnisse noch weiter zu optimieren. Das liegt daran, dass unsere Ultraschallmessdaten durch Anregung elastischer Wellen generiert werden. In einem ersten Schritt haben wir zwei elastische 2D-RTM-Algorithmen an synthetischen Ultraschalldaten getestet. Diese wurden mit einem Betonmodell, bestehend aus mehreren Stufen und kreisförmigen Lufteinschlüssen, erzeugt. In einem zweiten Schritt wurden reale Ultraschalldaten mit Scherwellenprüfköpfen an einer Betonstufenplatte mit integrierten Hüllrohren aufgenommen. Die Auswertung der realen Daten mit unserem elastischen RTM-Code war ebenfalls erfolgreich. Wir konnten die Abbildungsqualität der Stufen und Hüllrohre im Vergleich zur akustischen RTM und SAFT verbessern.
The majority of ultrasonic devices used for non-
destructive testing in civil engineering require contact with the
surface of the concrete (specimen), which significantly increases
the time required for the measurement. This makes it impractical
for extensive investigation of large-scale structures such as bridge
decks, foundations, or tunnels.
In a pioneering approach, fluidic oscillators are used as contact
free ultrasonic sources to overcome the aforementioned limi-
tations. These robust and cost-effective actuators require only
pressurised air and are ideally suited for harsh environments. At
a constant supply pressure, they generate a continuous mono-
frequent actuation signal. Further, varying the supply pressure
via a fast pressure regulator was found to generate a frequency
modulated signal which enabled time-of-flight measurement with
an added advantage of increased signal to noise ratio. To
demonstrate the feasibility of this novel idea of non-contact
ultrasound, the results of the initial tests are presented.
The majority of ultrasonic devices used for non-destructive testing in civil engineering require contact with the surface of the concrete (specimen), which significantly increases the time required for the measurement. This makes it impractical for extensive investigation of large-scale structures such as bridge decks, foundations, or tunnels.
In a pioneering approach, fluidic oscillators are used as contact
free ultrasonic sources to overcome the aforementioned limitations. These robust and cost-effective actuators require only pressurised air and are ideally suited for harsh environments. At a constant supply pressure, they generate a continuous monofrequent actuation signal. Further, varying the supply pressure via a fast pressure regulator was found to generate a frequency modulated signal which enabled time-of-flight measurement with an added advantage of increased signal to noise ratio. To demonstrate the feasibility of this novel idea of non-contact ultrasound, the results of the initial tests are presented.
The majority of ultrasonic devices used for non-destructive testing in civil engineering require contact with the surface of the concrete (specimen), which significantly increases the time required for the measurement. This makes it impractical for extensive investigation of large-scale structures such as bridge decks, foundations, or tunnels.
In a pioneering approach, fluidic oscillators are used as contact free ultrasonic sources to overcome the aforementioned limitations. These robust and cost-effective actuators require only pressurised air and are ideally suited for harsh environments. At a constant supply pressure, they generate a continuous mono-frequent actuation signal. Further, varying the supply pressure via a fast pressure regulator was found to generate a frequency modulated signal which enabled time-of-flight measurement with an added advantage of increased signal to noise ratio. To demonstrate the feasibility of this novel idea of non-contact ultrasound, the results of the initial tests are presented.
Laser Induced Breakdown Spectroscopy – A Tool for Imaging the Chemical Composition of Concrete
(2022)
One of the most common causes of damage is the ingress of harmful ions into the concrete, which can lead to deterioration processes and affect structural performance. Therefore, the increasingly aging infrastructure is regularly inspected to assess durability. Regular chemical analysis can be useful to determine the extent and evolution of ion ingress and to intervene in a timely manner. This could prove more economical than extensive repairs for major damage, particularly for critical infrastructure. In addition to already established elemental analysis techniques in civil engineering such as potentiometric titration or X-ray fluorescence analysis, laser-induced breakdown spectroscopy (LIBS) can provide further important complementary information and benefits. The possibilities of LIBS are demonstrated using the example of a drill core taken from a parking garage.
One of the most common causes of damage is the ingress of harmful ions into the concrete, which can lead to deterioration processes and affect structural performance. Therefore, the increasingly aging infrastructure is regularly inspected to assess durability. Regular chemical analysis can be useful to determine the extent and evolution of ion ingress and to intervene in a timely manner. This could prove more economical than extensive repairs for major damage, particularly for critical infrastructure. In addition to already established elemental analysis techniques in civil engineering such as potentiometric titration or X-ray fluorescence analysis, laser-induced breakdown spectroscopy (LIBS) can provide further important complementary information and benefits. The possibilities of LIBS are demonstrated using the example of a drill core taken from a parking garage.
Galvanic corrosion protection by embedded zinc anodes is an accepted technique for the corrosion protection of reinforcing steel in concrete. Galvanic currents flow between the zinc anode and the steel reinforcement due to the potential difference that is in the range of a few hundred mV.
The ion distribution was studied on two steel reinforced concrete specimens admixed with 3 wt.% chloride/wt. cement and galvanically protected by a surface applied EZ-anode. On both specimens, a zinc anode was embedded and glued to the concrete surface by a geo-polymer-based chloride-free binder. At one specimen, the EZ-anode was operated for 2,5 years, the EZ-anode at the other specimen was not electrically connected to the reinforcement, this specimen serves as a reference. Both specimens have been stored under identical conditions. The ion distribution between the anode (EZ-ANODE) and cathode (steel reinforcement) was studied by laser-induced breakdown spectroscopy (LIBS) after 7 months, 12 months, and 2,5 years. Results of the LIBS studies on the specimen with activated EZ-anode after 7 months, 12 months, and 2,5 years and of the reference specimen after 2,5 years are reported. Results show that diffusion of ions contributes to the changes in the ion distribution but migration, especially of chlorides towards the EZ-anode is significant despite the weak electric field – several hundred millivolts - generated by the galvanic current. Results show that chloride ions accumulate near the zinc-anode as in water-insoluble zinc-hydroxy chlorides - Simonkollite.
Existing concrete structures were usually designed for lifetimes of several decades. The current and urgently required efforts to increase sustainability and protect the environment will likely result in extended service lives up to 100 years. To achieve such objectives, it is required to assess structures over their entire lifecycles. Non-destructive testing (NDT) methods can reliably support the assessment of existing structures during the construction, operational, and decommissioning phases. One of the most important and safety-relevant components of a prestressed concrete structure are the tendons. NDT methods such as the ultrasonic echo method are suitable for both the detection and the localization of the tendons, i.e., the measurement of their geometrical position inside the component. The uniqueness of structures, concrete heterogeneity, and varying amounts of secondary components such as the reinforcement represent obstacles in the application of these methods in practice. The aim of this contribution is to demonstrate a practicable procedure, that can be used in the field to determine the parameters required for the measuring data analysis without extensive knowledge about the investigated components. For this purpose, a polyamide reference specimen is used to show which steps are required to obtain reliable imaging information on the position of tendons from the measurement data. The procedure is then demonstrated on a concrete test specimen that covers various relevant and practice-oriented test scenarios, such as varying tendon depths and component thicknesses.
Each engineering decision is based on a number of more or less accurate information. In assessment of existing structures, additional relevant information collected with on-site inspections facilitate better decisions. However, observed data basically represents the physical characteristic of interest with an uncertainty. This uncertainty is a measure of the inspection quality and can be quantified by expressing the measurement uncertainty. The internationally accepted rules for calculating measurement uncertainty are well established and can be applied straightforwardly in many practical cases. Nevertheless, the calculations require the occasionally time-consuming development of an individually suitable measurement model. This contribution attempts to emphasize proposals for modelling the non-destructive depth measurement of tendons in concrete using the ultrasonic echo technique. The proposed model can serve as guideline for the determination of the quality of the measured information in future comparable inspection scenarios.
In addition to already established structural monitoring methods such as deformation, inclination or strain gauges or acoustic emission sensors, sonic or ultrasonic monitoring might provide valuable information about the condition or alteration of a structure. Sensors such as geophones, recording ambient noise in the sonic and subsonic frequency range can provide information beyond modal analysis by using interferometric methods. Wave velocities determined by this method are related to the elastic properties and stiffness of material and structure and can be converted into damage indicators. Embedded active ultrasonic transducer networks can provide more detailed insight about deterioration or damages again, using interferometric technologies. This approach is extremely sensible, detecting relative change in velocity on down to 10-5. These methods, including benefits and remaining challenges, are demonstrated using data from a test structure at BAM’s test site demonstrating the case of prestress loss, and data from an actual bridge still under traffic.
Existing concrete structures were usually designed for lifetimes of several decades. The current and urgently required efforts to increase sustainability and protect the environment will likely result in extended service lives up to 100 years. To achieve such objectives, it is required to assess structures over their entire lifecycles. Non-destructive testing (NDT) methods can reliably support the assessment of existing structures during the construction, operational, and decommissioning phases. One of the most important and safety-relevant components of a prestressed concrete structure are the tendons. NDT methods such as the ultrasonic echo method are suitable for both the detection and the localization of the tendons, i.e., the measurement of their geometrical position inside the component. The uniqueness of structures, concrete heterogeneity, and varying amounts of secondary components such as the reinforcement represent obstacles in the application of these methods in practice. The aim of this contribution is to demonstrate a practicable procedure, that can be used in the field to determine the parameters required for the measuring data analysis without extensive knowledge about the investigated components. For this purpose, a polyamide reference specimen is used to show which steps are required to obtain reliable imaging information on the position of tendons from the measurement data. The procedure is then demonstrated on a concrete test specimen that covers various relevant and practice-oriented test scenarios, such as varying tendon depths and component thicknesses.
Approaches to the development of a (GUM-) measurement model for the calculation of measurement uncertainties in the localization of tendons in concrete structures using the ultrasonic echo method including demonstration were presented.
Imaging of results in NDT-CE: Strength and limitations in the use of Radar vs. Ultrasonic Echo
(2022)
Presentation on behalf of the co-author specified in BAM-Publica.
Study on capabilities of volume methods (GPR, Ultrasonic Echo) regarding lateral and depth localisation of reinforcement and tendons in concrete components. Varied boundary conditions: spacing and diameter of both the near surface rebars of the mesh, and the reflectors of interest, as well as component thickness and concrete cover. Please find corresponding references on slide 2.
Galvanic corrosion protection by embedded zinc anodes is an accepted technique for the corrosion protection of reinforcing steel in concrete. Galvanic currents flow between the zinc anode and the steel reinforcement due to the potential difference that is in the range of a few hundred mV. The ion distribution was studied on two steel reinforced concrete specimens admixed with 3 wt.% chloride/wt. cement and galvanically protected by a surface applied EZ-anode. On both specimens, a zinc anode was embedded and glued to the concrete surface by a geo-polymer-based chloride-free binder. At one specimen, the EZ-anode was operated for 2,5 years, the EZ-anode at the other specimen was not electrically connected to the reinforcement, this specimen serves as a reference. Both specimens have been stored under identical conditions. The ion distribution between the anode (EZ-anode) and cathode (steel reinforcement) was studied by laser-induced breakdown spectroscopy (LIBS) after 7 months, 12 months, and 2,5 years. Results of the LIBS studies on the specimen with activated EZ-anode after 7 months, 12 months, and 2,5 years and of the reference specimen after 2,5 years are reported. Results show that diffusion of ions contributes to the changes in the ion distribution but migration, especially of chlorides towards the EZ-anode is significant despite the weak electric field – several hundred millivolts - generated by the galvanic current. Results show that chloride ions accumulate near the zinc-anode as in water-insoluble zinc-hydroxy chlorides - Simonkolleit.
Underground sealing structures are necessary to seal radioactive or toxic waste in underground repositories. A special version of MgO concrete is used in the mine in Teutschenthal and applied at a large-scale test with the aim to provide a low permeability barrier. The test structures (up to 10 m long) were created by shotcreting. Besides destructive tests, non-destructive ultrasonic measurements have been evaluated for quality assurance to monitor potential anomalies such as cracks, concrete inhomogeneities, and delamination. We show results of ultrasonic measurements with a multi-transducer system used at the front and from the side of the concrete structure. Images are obtained by synthetic aperture focusing techniques. The boundaries between concreting sections are not visible in the ultrasonic images systematically so that a successful concreting is assumed, which is confirmed by the low permeabilities observed. Several reflectors up to a depth of 1.2 m are identified and interpreted as potential damages in the concrete. Phase analysis of prominent reflectors reveal a negative impedance contrast thus indicating air filled voids, cracks or delamination. Boreholes through some of the identified reflectors are used to verify the results from ultrasonic measurements. Additionally, an experiment with incorporated artificial defects was undertaken to analyse the reliability of the applied methods. Overall, the conducted tests show the potential of ultrasonic measurements to detect critical anomalies. Despite challenges at small-scale structures (cm-order), large-scale anomalies can be identified. Consequently, implementing ultrasonic monitoring during and after the construction of concrete sealing structures has shown its potential as a tool for quality assurance, but needs further development and validation.
Multifaceted developments for pre-disposal management of low and intermediate level radioactive waste are undertaken in the EC funded project PREDIS. In work package 7, innovations in cemented waste handling and pre-disposal storage are advanced by testing and evaluating. To provide better means for safe and effective monitoring of cemented waste packages including prediction tools to assess the future integrity development during pre-disposal activities, several monitoring and digital tools are evaluated and improved. Both safety enhancement (e. g. less exposure of testing personnel) and cost effectiveness are part of the intended impact. Current methods to pack, store, and monitor cemented wastes are identified, analysed and improved. Innovative integrity testing and monitoring techniques applied to evaluate and demonstrate package and storage quality assurance are further developed. The work includes but is not limited to inspection methods such as muon imaging, wireless sensors integrated into waste packages as well as external package and facility monitoring such as remote fiber optical sensors. The sensors applied will go beyond radiation monitoring and include proxy parameters important for long term integrity assessment (e. g. internal pressure). The measured data will be used in digital twins of the packages for specific simulations (geochemical, integrity) providing a prediction of future behaviour. Machine Learning techniques trained by the characterization of older packages will help to connect the models to the actual data. As data handling, processing and fusion are crucial for both the monitoring and the digital twin model, all data (measured and simulated) will be collected in a joint data base and connected to a decision framework. Finally, the implementation of the improved techniques will be tested at actual facilities. An overview about various relevant tools, their interconnections, and first research results will be shown.
New materials and innovative monitoring for safe sealing structures in underground repositories
(2022)
Within the project SealWasteSafe, we advance construction materials and monitoring concepts of sealing structures applied for underground disposal of nuclear waste. As these engineered barriers have high demands concerning integrity, an innovative alkali-activated material (AAM) is improved and tested on various laboratory scales that is highly suitable for the application in salt as a host rock. This AAM has a low reaction kinetics related to a preferential slow release of the heat of reaction in comparison to alternative salt concretes based on Portland cement or magnesium oxychloride cements. Hence, crack formation due to thermally induced strain is reduced. A comprehensive multi-sensory monitoring scheme is developed and investigated to compare the setting process of AAM and salt concrete for manufactured specimens (100-300 l). The analysed parameters include temperature and humidity of the material, acoustic emissions, and strain variations recorded by fiber optic cables. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete allow for wireless access and are compared to conventional cabled systems for temperature and humidity measurements. Furthermore, ultrasonic methods are used for quality assurance to detect obstacles, potential cracks and delamination. Field layout and applied imaging techniques are optimised to enhance the image quality. To characterise the inside of the test engineered barrier and achieve a proof-of-concept, an ultrasonic borehole probe is developed to allow for phased arrays that can further improve the detection of potential cracks. Modelling results and first analysis of half-spherical specimen prove the reliability of the directional response caused by the phased arrays of the newly constructed ultrasonic borehole probe. Overall, the project SealWasteSafe improves the construction material, multi-sensory monitoring concepts and ultrasonics for quality assurance. Particularly for salt as a host rock, this will help to develop safe sealing structures for nuclear waste disposal.
Underground sealing structures are necessary to seal radioactive or toxic waste in underground repositories. Particularly developed MgO concrete is used in the mine in Teutschenthal and applied at a large-scale test with the aim to provide concrete with low permeabilities. The test structures (up to 10 m long) were created with the help of a shotcrete procedure. Besides destructive tests, non-destructive ultrasonic measurements are used for quality assurance to monitor potential anomalies such as cracks, concrete inhomogeneities, and delamination. We show results of ultrasonic measurements with a multi-transducer system used at the front site of the concrete structure. Images are obtained by synthetic aperture focusing techniques. Concreting sections are not systematically imaged so that a successful concreting is assumed as also indicated by observed low permeabilities. Several reflectors up to a depth of 1.2 m are identified and interpreted as potential damages in the concrete. Phase analysis of prominent reflectors reveal a negative impedance contrast thus indicating air filled voids, cracks or delamination. Boreholes through some of the identified reflectors are used to verify the results from ultrasonic measurements. Additionally, an experiment with incorporated defects is undertaken to analyse the reliability of the applied methods. Overall, the conducted tests show the great potential of ultrasonic measurements to detect critical anomalies. Despite challenges at small-scale structures (cm-order), large-scale anomalies can be identified. Implementing ultrasonic monitoring during and after the construction of concrete sealing structures is recommended as a tool for quality assurance.
Geophysical methods are able to contribute significantly to geotechnical site characterization. In-situ parameters are collected and gaps between boreholes or other direct tests are filled with information. However the limited resolution has to be considered and the indirect geophysical parameters have to be translated into something geotechnically useful. Moreover, the limitations have to be evaluated when including geophysical data into geostatistical models. If done properly, the use of geophysics will help in an efficient and effective site characterization. A comprehensive overview on existing geophysical (mostly seismic) methods is given as well as information on the calibration of geophysical against geotechnical parameters, pitfalls and limitations and some hints how to include these data into geostatistical/geotechnical models.
The Boltzmann plot is one of the most widely used methods for determining the temperature in different types of laboratory plasmas. It operates on the logarithm as a function of the dimensional argument, which assumes that the correct physical units are used. In many works using the Boltzmann method, there is no analysis of the dimension of this argument, which may be the cause of a potential error. This technical note offers a brief description of the method and shows how to correctly use physical units when using transcendental functions like the logarithm.
During their life span, concrete structures interact with many kinds of external mechanical loads. Most of these loads are considered in advance and result in reversible deformations. Nevertheless, some of the loads cause irreversible, sometimes unnoticed changes below the macroscopic scale depending on the type and dimension of the impact. As the functionality of concrete structures is often relevant to safety and society, their condition must be known and, therefore, assessed on a regular basis. Out of the spectrum of non-destructive monitoring methods, Coda Wave Interferometry using embedded ultrasonic sensors is one particularly sensitive technique to evaluate changes to heterogeneous media. However, there are various influences on Coda waves in concrete, and the interpretation of their superimposed effect is ambiguous. In this study, we quantify the relations of uniaxial compression and uniaxial tension on Coda waves propagating in normal concrete. We found that both the signal correlation of ultrasonic signals as well as their velocity variation directly reflect the stress change in concrete structures in a laboratory environment. For the linear elastic range up to 30% of the strength, we calculated a velocity variation of −0.97‰/MPa for compression and 0.33%/MPa for tension using linear regression. In addition, these parameters revealed even weak irreversible changes after removal of the load. Furthermore, we show the time-dependent effects of shrinkage and creep on Coda waves by providing the development of the signal parameters over time during half a year together with creep recovery. Our observations showed that time-dependent material changes must be taken into account for any comparison of ultrasonic signals that are far apart in time. The study’s results demonstrate how Coda Wave Interferometry is capable of monitoring stress changes and detecting even small-size microstructural changes. By indicating the stated relations and their separation from further impacts, e.g., temperature and moisture, we anticipate our study to contribute to the qualification of Coda Wave Interferometry for its application as an early-warning system for concrete structures.
Responsible treatment of the environment and resources is a key element of sustainability. The building and construction industry is one of the largest consumers of natural resources. Consequently, there is a particular need for regulations and technologies that help to create closed material cycles. From the technological point of view, such efforts are complicated by the growing material diversity and the amount of composites contained in present and future construction and demolition waste (CDW). Nowadays, simple but proven techniques like manual sorting are mainly used. However, this practice not only poses health risks and dangers to the staff performing the work, but also relies on merely obvious, visually striking differences. Automated, sensor-based sorting of these building materials could complement or replace this practice to improve processing speed, recycling rates, sorting quality, and prevailing health conditions. The preliminary results for the identification of a wide variety of building materials with LIBS are presented.
Concrete structures often show severe damage during their lifetime. One such damage is pitting corrosion of the steel reinforcement caused by chloride ingress into the porous concrete structure. Laser-induced breakdown spectroscopy (LIBS) is a promising method in civil engineering, which is used for detection of chlorine in concrete structures in addition to conventional methods of wet chemistry. To assess LIBS as a trustful analytical technique, its accuracy and robustness is carefully tested. The presentation will outline the results of the interlaboratory comparison of chlorine quantification in cement paste samples, which was carried out by 12 laboratories in 10 countries. Two sets of samples with chloride content ranging from 0.06-1.95 wt.% in the training set and 0.23-1.51 wt.% in the test sample set (“unknowns”), with additional variations in the type of cement and chlorine source (salt type) were sent to the laboratories. The overall result demonstrates that LIBS is suitable for the quantification of the investigated sample compositions: average relative bias was mostly below 15 %. Considering that the laboratories did not receive instructions on how to perform the analysis or how to process the data, the results can be evaluated as a true status quo of the LIBS technique for this type of analysis.
This study aims to develop a real time structural health monitoring method by ultrasonic tests combined with advanced six component (6C) translation and rotation measurements. Conventionally, the investigation of the velocity and acceleration response in the translation direction is used to obtain the eigenfrequencies of structures. Recently the measurement of rotation has been considered to fully characterize the dynamic behavior of structures. This research undertakes the evaluation of a novel 6C sensor (IMU50-iXblue) with components originally developed for navigation for the purpose of bridge monitoring. However, as for all vibration recordings, there is a certain influence of environmental conditions (mainly temperature) which may affect evaluation and the results of structural assessment. We propose applying the cross-correlation function to the 6C ambient vibration signals to reconstruct wave propagation and using coda wave interferometry (CWI) to obtain internal velocity variation from waveforms. A field experiment on a large-scale prestressed concrete bridge model is presented. To verify that we are able to identify the pre-stress loss even in presence of temperature effects, we perform measurements in two different scales: the ultrasonic and output-only, vibration measurements. The change in the structural properties due to the pre-stress loss should be detected by the pulse velocity change. The results reveal both the performance and advantages of ultrasonic techniques and the capabilities of 6C sensors. To conclude, the application of CWI to wave signals contributes to a comprehensive assessment for bridge monitoring.
The acquisition and appropriate processing of relevant information about the considered system remains a major challenge in assessment of existing structures. Both the values and the validity of computed results such as failure probabilities essentially depend on the quantity and quality of the incorporated knowledge. One source of information are onsite measurements of structural or material characteristics to be modeled as basic variables in reliability assessment. The explicit use of (quantitative) measurement results in assessment requires the quantification of the quality of the measured information, i.e., the uncertainty associated with the information acquisition and processing. This uncertainty can be referred to as measurement uncertainty. Another crucial aspect is to ensure the comparability of the measurement results.This contribution attempts to outline the necessity and the advantages of measurement uncertainty calculations in modeling of measurement data-based random variables to be included in reliability assessment. It is shown, how measured data representing time-invariant characteristics, in this case non-destructively measured inner geometrical dimensions, can be transferred into measurement results that are both comparable and quality-evaluated. The calculations are based on the rules provided in the guide to the expression of uncertainty in measurement (GUM). The GUM-framework is internationally accepted in metrology and can serve as starting point for the appropriate processing of measured data to be used in assessment. In conclusion, the effects of incorporating the non-destructively measured data into reliability analysis are presented using a prestressed concrete bridge as case-study.
This study aims to develop a real-time monitoring method for the structural performance by ultrasonic testing in combination with six-component (6-C) translation and rotation measurements. So far, the recordings of the velocity and acceleration response in the translation direction have been used to obtain the eigenfrequencies of structures. Recently, measurement of rotation has been used to fully characterize the dynamic behavior of structures. In this research, 6-C sensors consisting of a three-component rotational seismometer and a three-component broadband seismometer are evaluated for their suitability for bridge monitoring. Since changes in environmental conditions such as temperature during vibration recordings affect the structural evaluation results, cross-correlation function is applied here to the 6-C ambient vibration signals to reconstruct the wave propagation on the one hand, and coda wave interferometry (CWI) is applied to obtain the internal velocity variation from waveforms on the other hand. In field tests on a large-scale prestressed concrete bridge model, it was verified whether the prestress loss can also be determined in presence of temperature effects. For this purpose, measurements were performed in two scales, ultrasonic and output-only vibration measurements. The change in structural properties due to the prestress loss should be detected by the pulse velocity change. The results demonstrate both the performance and advantages of ultrasonic techniques and the capabilities of 6-C sensors. Thus, the application of CWI to wave signals can contribute comprehensively to bridge monitoring.
Introduction of a monitoring system for Bingham fluids in additive manufacturing with concrete
(2022)
Freeform additive manufacturing of concrete structures is a rising technology in civil engineering with several fascinating advantages. Nonetheless, to ensure reliability and structural integrity, standards and quality control are required in the future to bring this technology into the market. As the concrete is manufactured continuously, continuous quality control of the printing process is also required, i.e. comprehensive process monitoring. At BAM, a test rig will be installed, enabling the printing of concrete structures with a maximum size of 2 m x 1 m x 1 m (l x w x h). Here, process monitoring is the focus of the test rig. In this study, we show the results of the first pump tests, including the measurement of several parameters such as temperature and pressure along the supply system, i.e. from the concrete pump to the printer head.
Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert.
This contribution introduces an investigation of a large-scale prestressed concrete bridge model (“BLEIB” structure at the BAM-TTS open air test site) by means of on-site cooperative measurements. This bridge has an external post-tensioning system and has been instrumented with the ultrasonic transducers, temperature sensors and optical fibers for Distributed Acoustic Sensing (DAS). Our experiment was designed to test the suitability of the novel 6C sensors developed within the framework of the GIOTTO project – the IMU50. The IMU50 sensor enables vibration measurements in translation along three axes and rotation around three axes. The geophone sensors were considered for complementary measurements of vertical velocity response. In the experiment, several perturbations were achieved by controlling the external influence factors such as loading and prestressing changes. The aim of the integrated measurement strategy was to fully observe the results of the condition change and to verify the effectiveness of multiple sensors for bridge monitoring.
Introduction of a monitoring system for Bingham fluids in additive manufacturing with concrete
(2022)
Freeform additive manufacturing of concrete structures is a rising technology in civil engineering with several fascinating advantages. Nonetheless, to ensure reliability and structural integrity, standards and quality control are required in the future to bring this technology into the market. As the concrete is manufactured continuously, continuous quality control of the printing process is also required, i.e. comprehensive process monitoring. At BAM, a test rig will be installed, enabling the printing of concrete structures with a maximum size of 2 m x 1 m x 1 m (l x w x h). Here, process monitoring is the focus of the test rig. In this study, we show the results of the first pump tests, including the measurement of several parameters such as temperature and pressure along the supply system, i.e. from the concrete pump to the printer head.
Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert.
This contribution introduces an investigation of a large-scale prestressed concrete bridge model (“BLEIB” structure at the BAM-TTS open air test site) by means of on-site cooperative measurements. This bridge has an external post-tensioning system and has been instrumented with the ultrasonic transducers, temperature sensors and optical fibers for Distributed Acoustic Sensing (DAS). Our experiment was designed to test the suitability of the novel 6C sensors developed within the framework of the GIOTTO project – the IMU50. The IMU50 sensor enables vibration measurements in translation along three axes and rotation around three axes. The geophone sensors were considered for complementary measurements of vertical velocity response. In the experiment, several perturbations were achieved by controlling the external influence factors such as loading and prestressing changes. The aim of the integrated measurement strategy was to fully observe the results of the condition change and to verify the effectiveness of multiple sensors for bridge monitoring.
Damage Assessment of Civil Structures Using Wave Propagation Analysis and Transmissibility Functions
(2022)
A common damage detection method in civil engineering is to monitor dynamic characteristics such as natural frequencies and modal shapes, which are directly related to the structural stiffness. However, the discrepancy in measured natural frequencies may result from environmental changes, the soil-structure interaction or effects caused by earthquakes. This makes it difficult to decide whether the local change in structural properties is caused by damage or other factors. To address this challenge and thus improve the current damage detection method, the wave propagation analysis method and the transmissibility relationship were considered. In our study, the wave propagation field in structures was reconstructed by applying the Normalized-Input-Output-Minimization (NIOM) method to vibration recordings. Wave velocities and transmissibility functions were considered as reference values for the damage indicators. This paper demonstrates the evaluation of local property changes in two examples of large-scale structures: a 14-story RC building and a 64 m long pedestrian bridge. The proposed damage indicators show a clear correspondence to structural changes.
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications. To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. Its applicability to measurements in concrete is verified. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
Several countries, which use or used nuclear power, started to destruct nuclear power plants. Thus, large amounts of radioactive waste have to be stored safely during the next decades. Large underground caverns will
be used a nuclear waste disposal. Once the cavern is full, a sealing construction is required. The sealing should avoid the contact to any fluids or substances of the storage barrels and reduce hazardous radiation.
Ultrasonic measurement technology has become indispensable in NDT-CE. Air-coupled ultrasonic (ACU) measurement techniques promise to reduce measurement time. However, the signal quality suffers from large specific impedance mismatch at the transducer-air and air-specimen interface. Additionally, large pressure amplitudes are necessary for the penetration depth required in NDT-CE applications.
To address the specific requirements of ultrasonic testing in NDT-CE, a robust ACU transducer was developed, that generates ultrasound by quickly switching a pressurized air flow. The simple design of the fluidic transducer makes the device maintenance free and resilient against harsh environmental conditions. Since the signal is generated by aeroacoustics, there is no specific impedance mismatch between the transducer and the surrounding air. The ultrasonic signal exhibits frequencies in the 30-60 kHz range and is therefore well suited to penetrate heterogenous materials such as concrete. This contribution gives an introduction in the working principle and signal characteristics of the fluidic transducer. A detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
Recently, non-destructive testing in civil engineering (NDT-CE), in particular of concrete components, has successfully mastered the leap from research to practice. Several methods have been established for field inspections to determine the concrete cover of reinforcement or to estimate the compressive strength as well as other parameters related to the concrete material. In addition, the application of nondestructive testing is indispensable, if information about the inner structure - such as the location of rebars and tendon ducts or the damage-related condition assessment to detect grouting defects, honeycombs, delamination, or corrosion - is required. Besides the selection of a suitable NDT method and an appropriate inspection system, the reliability of the results depends largely on the person who applies the non-destructive inspection technique and evaluates the inspection results. To ensure a high quality of non-destructive concrete evaluation as well as to keep the uncertainty caused by the inspection personnel to a minimum, structured, consistent and regulated theoretical as well as practical training of inspection personnel is essential. To close this gap, the subcommittee of education (UA-A) within the committee for NDT-CE of the German Society for Nondestructive Testing (DGZfP) has been reactivated in 2018 to establish uniform training standards for nondestructive concrete inspections in the long term. The subcommittee consists of scientists, practitioners, authorities, and clients. So far, the national standard DIN 4871 “Non-destructive testing - Qualification and Certification of NDT personnel in Civil Engineering (NDT-CE)” was developed and is currently under review. This standard considers the civil-industry-specifics, for example, that standards for NDT of concrete, as well as related product standards with a few exceptions, still do not exist at the moment. Within this presentation, the concept, the connection to ISO 9712 and other standards as well as an overview of the developed German standard DIN 4871 will be presented.
Recently, non-destructive testing in civil engineering (NDT-CE), in particular of concrete components, has successfully mastered the leap from research to practice. Several methods have been established for field inspections to determine the concrete cover of reinforcement or to estimate the compressive strength as well as other parameters related to the concrete material. In addition, the application of non-destructive testing is indispensable, if information about the inner structure - such as the location of rebars and tendon ducts or the damage-related condition assessment to detect grouting defects, honeycombs, delamination, or corrosion - is required. Besides the selection of a suitable NDT method and an appropriate inspection system, the reliability of the results depends largely on the person who applies the non-destructive inspection technique and evaluates the inspection results. To ensure a high quality of non-destructive concrete evaluation as well as to keep the uncertainty caused by the inspection personnel to a minimum, structured, consistent, and regulated theoretical as well as practical training of inspection personnel is essential. To close this gap, the subcommittee of education and training (UA-A) within the committee for NDT-CE of the German Society for Non-Destructive Testing (DGZfP) has been reactivated in 2018 to establish uniform training standards for non-destructive concrete inspections in the long term. The subcommittee consists of scientists, practitioners, authorities, and clients. So far, the national standard DIN 4871 “Non-destructive testing - Qualification of NDT personnel in Civil Engineering (NDT-CE)” was developed. This standard considers the civil-industry-specifics, for example, that standards for NDT of concrete, as well as related product standards with a few exceptions, still do not exist at the moment. Within this presentation, the concept, the connection to ISO 9712 and other standards as well as an overview of the recently developed German standard DIN 4871 will be presented.
The ‘Gänstorbrücke’ bridge between the cities of Ulm and Neu-Ulm is one of the best-monitored bridges all over Germany. In addition to an already active bride monitoring system, we have equipped the bridge with 30 ultrasonic transducers to explore the monitoring possibilities at an in-service large-scale reinforced concrete structure with continuous active ultrasonic measurements. The monitoring system is based on the detection of small changes in the entire signal, especially the multiply scattered parts of the recording, the so-called coda. Applying Coda Wave Interferometry (CWI), subtle changes in the signal can be detected and related to changing velocities in the area between source and receiver. A comparison of the results from coda wave interferometry with the strain measurements of the permanent monitoring system shows a correlation between strain measurements and CWI results. We discuss the challenges of changing environmental conditions, pose for interpretation of the results, and highlight the advantages of embedded versus externally attached ultrasonic transducers in permanent bridge monitoring, especially when coda wave interferometry is applied.
The ‘G¨anstorbr¨ucke’ bridge between the cities of Ulm and Neu-Ulm is one of the best-monitored bridges all over Germany. In addition to an already active bride monitoring system, we have equipped the bridge with 30 ultrasonic transducers to explore the monitoring possibilities at an in-service large-scale reinforced concrete structure with continuous active ultrasonic measurements. The monitoring system is based on the detection of small changes in the entire signal, especially the multiply scattered parts of the recording, the so-called coda. Applying Coda Wave Interferometry (CWI), subtle changes in the signal can be detected and related to changing velocities in the area between source and receiver. A comparison of the results from coda wave interferometry with the strain measurements of the permanent monitoring system shows a correlation between strain measurements and CWI results. We discuss the challenges of changing environmental conditions, pose for interpretation of the results, and highlight the advantages of embedded versus externally attached ultrasonic transducers in permanent bridge monitoring, especially when coda wave interferometry is applied.
Within a DFG-funded research group, we investigate the possibility of concrete damage assessment with coda waves. Coda wave interferometry (CWI) can be a valuable asset to structural health monitoring (SHM) as we can detect small signal changes and quantify them with the calculation of relative velocity changes. By equipping an in-service road bridge with more than 24 embedded ultrasonic transducers, we want to analyze how methods developed within the research group perform in an uncontrollable environment. We evaluate individual source-receiver combinations for detection of temporal changes as well as the entire installed sensor array to create maps of material change comparing two distinct states of the bridge.
The project "SealWasteSafe" of the Bundesanstalt für Materialforschung und -prüfung (Berlin) deals with sealing structures applied for underground disposal of nuclear waste from two perspectives: material improvement for application in sealing constructions and feasibility study regarding multi-sensor approaches to ensure quality assurance and long-term monitoring.
One specimen of 150 l made of alkali-activated material, which was found innovative and suitable for sealing constructions based on preliminary laboratory studies, and another one made of conventional salt concrete, are manufactured with an integrated multi-sensory setup for quality assurance and long-term-monitoring. The specimens were left in their cast form and additionally thermally insulated to simulate the situation in the repository. The multi-sensory concept comprises RFID technology embedded in the specimens suppling material temperature and moisture measurements, integrated distributed fibre optic sensing allowing strain measurement and acoustic emission testing for monitoring crack formation. Overall, the suitability and the functionality of the sensors embedded into and attached to strongly alkaline (pH > 13 for the AAM) and salt corrosive (NaCl) environment was proven for the first 672 h.
First RFID measurement succeeded after 626 h for the alkali-activated material and after 192 h for the conventional salt concrete. Strain measurement based on fibre optic sensing turned out the alkali-activated material (> 1 mm/m) undergoing approximately twice the compression strain as the salt concrete (< 0.5 mm/m). In contrast, the acoustic emission first and single hits representing crack formation in numbers, was found for alkali-activated material half of that detected at the salt concrete.
Investigation of temperature effects on ultrasonic velocity in a prestressed concrete bridge model
(2022)
Ultrasonic measurements have recently been applied in the context of structural health monitoring in civil engineering. The ultrasonic method is very sensitive to environmental conditions and material property changes, which might be caused by prestress losses and loading effects on the bridge. However, it remains a challenge to identify the damage mechanisms causing structural property changes from the above mentioned factors influencing ultrasonics. The focus of this contribution is to investigate the correlation between ultrasonic velocities and temperature by the coda wave interferometry (CWI) analysis. Long-term monitoring of a prestressed concrete bridge model under field conditions was carried out to observe the effect of temperature. The homogeneous change in concrete caused by temperature was revealed by applying the CWI method. The threshold value of the best correlation coefficients for the linear regression of temperature and ultrasonic velocity changes was also studied. Experimental assessment will provide a ratio for temperature correction to evaluate the pre-stressing force decrease and its consequences on crack opening or extension.
This dataset contains raw data resulting from Impact-Echo measurements at the reference concrete block "IE Platte", located at BAM (German Federal Institute for Materials Research and Testing).
The specimen contains three polystyrene slabs and one polyethylene foil to act as reflectors. The specimen was produced in a three-step process. First, the base plate was cast. Second, the reflectors were taped to the base plate. Finally, the upper layer was cast on top of base plate and reflectors. A drawing is contained in the dataset.
The Impact-Echo method is based on the excitation of the zero-group-velocity frequency of the first symmetric Lamb mode of a plate-like structure, in order to assess its thickness. Numerous publications elaborate on Impact-Echo theory, examples are (Gibson and Popovics 2005, Schubert and Köhler 2008 , Abraham and Popovics 2010).
The measurements have been conducted using a setup that contains only commercially available components. The setup consists of an Olson CTG-2 concrete thickness gauge (Olsen Instruments, USA) for actuation and sensing and an 8-bit NI USB-5132 digital storage oscilloscope (National Instruments, USA) combined with the Echolyst software (Schweizerischer Verein für technische Inspektionen (SVTI), Switzerland) for data acquisition.
Measurements were conducted using a grid of 29x29 points with a spacing of 50 mm. At each point 8192 samples were recorded at a sampling rate of 1 MS/s.
The dataset contains the (X,Y) location in mm of the individual measurement points as well as the raw measurement data at those points.
The data is provided in the formats *.mir/*.mhdr (Echolyst), *.npy (Python) and *.mat (Matlab) and *.csv to ease the import in various post-processing tools.
Investigation of temperature effects on ultrasonic velocity in a prestressed concrete bridge model
(2022)
Ultrasonic measurements have recently been applied in the context
of structural health monitoring in civil engineering. The ultrasonic method is very sensitive to environmental conditions and material property changes, which might be caused by prestress losses and loading effects on the bridge. However, it remains a challenge to identify the damage mechanisms causing structural property changes from the above-mentioned factors influencing ultrasonics. The focus of this contribution is to investigate the correlation between ultrasonic velocities and temperature by the coda wave interferometry (CWI) analysis. Long-term monitoring of a prestressed concrete bridge model under field conditions was carried out to observe the effect of temperature. The homogeneous change in concrete caused
by temperature was revealed by applying the CWI method. The threshold value of the best correlation coefficients for the linear regression of temperature and ultrasonic velocity changes was also studied. Experimental assessment will provide a ratio for temperature correction to evaluate the prestressing force decrease and its consequences on crack opening or extension.
Das Bauwesen erfordert sehr hohe Flächenleistungen, so dass der physische Kontakt zur Oberfläche möglichst vermieden werden sollte, um eine hohe Verfahrgeschwindigkeit der Sensoren zu gewährleisten. Andererseits weisen luftgekoppelte, membranbasierte Aktuatoren durch den Impedanzsprung sehr hohe Verluste auf. Daher stellt das schnelle berührungslose Ultraschallmessen immer noch eine ungelöste Herausforderung im Bauwesen dar.
Neue Ultraschall-Messsysteme (LAUS, Bohrlochsonde) haben ihre Funktionstüchtigkeit unter Beweis gestellt. Ergebnisse aus den Messungen konnten verifiziert werden. Standard-Mess- und –Auswerteverfahren müssen für Spritzbeton weiterentwickelt und angepasst werden. Mit sämtlichen Messmethoden konnten großflächige Risse detektiert werden. Messungen mit der Bohrlochsonde und LAUS sind zur Qualitätssicherung geeignet.
Verschlussbauwerke sind für die untertägige Endlagerung im Salzgestein als eine wichtige technische Barriere vorgesehen. Diese Bauwerke müssen hohen Anforderungen an Sicherheit und Integrität genügen, weshalb im Projekt SealWasteSafe Werkstofftechnik, Prüfverfahren und Überwachungsmethoden für sichere Verschlussbauwerke verbessert werden. Dabei zeigen die untersuchten alkaliaktivierten Materialien (AAM) langsamere Reaktionskinetik bei der Erhärtung im Vergleich zu Salzbeton, was potenziell geringere Rissbildung erwarten lässt. Die Erhärtung wird an Probekörpern (100-300 l) multisensorisch über einen Zeitraum von mindestens 28 Tagen überwacht. Die Parameter Temperatur und Feuchtigkeit werden einerseits kabelgebunden, andererseits mittels drahtloser Radio Frequency Identification (RFID)-Technik aufgezeichnet. Zusätzlich kommen Schallemissionsmessungen sowie Dehnungsmessungen mittels verteilter faseroptischer Sensorik (FOS) zum Einsatz. Die Überwachung zeigt verschiedene Charakteristika beim Erhärten der Materialien mit geringerer Temperaturentwicklung des AAM. Zusätzlich werden Ultraschallmessungen genutzt, um Einbauteile und Störstellen wie Risse und Delaminationen im Rahmen der Qualitätssicherung am Probekörper und am Verschlussbauwerk zu detektieren. Dafür werden sowohl ein Ultraschallmesssystem mit großer Apertur (LAUS) als auch eine Ultraschall-Bohrlochsonde eingesetzt. Durch Erhöhung des Schalldrucks und Schallfeldbündelung im Beton wird die Aussagekraft der von der Bohrlochsonde aufgezeichneten Messsignale verbessert, was in Modellierungen und ersten Labortests gezeigt werden kann. Die Auswertung der Ultraschallmessungen zeigt das große Potenzial der Methode mit Eindringtiefen bis zu 9 m, wobei anspruchsvolle Abbildungsverfahren zu einer verbesserten Abbildung der internen Strukturen führen. Insgesamt verbessern die im Projekt SealWasteSafe entwickelten Materialien und Methoden die Möglichkeiten für sichere Verschlussbauwerke nuklearer Endlager. Obwohl die Konzepte speziell für Bauwerke im Salzgestein entwickelt werden, sind sie partiell gut auf andere Wirtsgesteine übertragbar.
Im Jahre 2011 wurde in Deutschland nach 50 Jahren der Ausstieg aus der kommerziellen Kernenergie beschlossen. Fünf Jahre später war Deutschland mit 80.000 GWh immer noch unter den zehn größten Atomstromproduzenten. Im darauffolgenden Jahr wurden weltweit 2.500.000 GWh Atomstrom produziert. Durch die Atomstromproduktion fallen große Mengen an radioaktiven Reststoffen an, die bis zu mehrere tausend Jahre für einen vollständigen Abbau benötigen. Aus dieser Problematik geht die Debatte über den Verbleib der Reststoffe hervor. Die Endlagerung in tiefen Gesteinsschichten ist eine Lösung für das Problem. Voraussetzung ist hierbei allerdings die Gewährleistung eines dauerhaften Schutzes vor ionisierender Strahlung, die durch Verschlüsse der tiefen Gesteinsschichten in Form von Verschlussbauwerken erzielt werden sollen. Es gilt die bauliche Integrität sowie die Dichtwirkung der Verschlussbauwerke dauerhaft zu überwachen und zu prüfen, um eine langfristige Verzögerung der Radionuklidfreisetzung zu gewährleisten.
This research is to perform passive and active measurements on a
large-scale prestressed concrete bridge model under the outdoor
condition. Multi sensors were applied to this test structure –
BLEIB, which is located at the BAM test site. The experimental
evaluation of ultrasonic wave propagation and seismic noise
recordings were considered for revealing the bridge damage
condition, as a basic for developing a reliable bridge monitoring
system.
Analyse des gefügeabhängigen Löslichkeitsverhaltens potenziell AKR-empfindlicher Gesteinskörnungen
(2021)
Das gefügeabhängige Löslichkeitsverhalten wurde an folgenden vier Gesteinskörnungen unterschiedlicher Alkaliempfindlichkeitsklassen
untersucht:
• GK1 (EIII-S): quarzreicher Kies
• GK2 (EIII-S): Grauwacke (Splitt)
• GK3 (EI-S): Quarz-Feldspat-Porphyr (Splitt)
• GK4 (EI-S): sandsteinreicher Kies
DiePorenstrukturanalyse erfolgte sowohl an Einzelkörnern mittels vergleichender 3D-CT und BET- Untersuchungen als auch an Korngemengen der einzelnen Kornfraktionen (außer Fraktion 16/22 mm) über die Wasseraufnahme und mit BET. Für die Visualisierung und Quantifizierung der von außen zugänglichen Oberflächenanteile der Einzelkörner wurde ein Softwaretool entwickelt, erprobt und erfolgreich angewandt. Es gelang so u.a. den Nachweis zu erbringen, dass die gebrochenen Einzelkörner der Grauwacke und des Rhyoliths einen deutlich geringeren von außen zugänglichen Oberflächenanteil als die gleichartigen Gesteinskörner aus dem Kies besitzen. Aufgrund der limitierten Ortsauflösung der 3D-CT von 11 bis 16,5 μm wurde mit BET eine um drei Zehnerpotenzen höhere spezifische Oberfläche ermittelt.
Zu den Porositätsuntersuchungen an den Korngemengen sei angemerkt, dass zum Teil gegenläufige Trends zwischen offener Porosität und spezifischer Oberfläche festgestellt wurden. Dieses ist beim Bezug des bei den Löseversuchen in 0,1 M KOH mit definierter NaCl-Zugabe aus der Gesteinskörnung gelösten SiO2 und Al2O3 von zentraler Bedeutung. Bei den Löseversuchen an den fraktionsspezifischen Korngemengen selbst zeigte sich, dass die stufenweise Erhöhung des NaCl-Gehalts von 0 auf 10 M.-% im Eluat eine erhöhte SiO2-Löslichkeit und eine verminderte Auslaugung von Al2O3 zur Folge hat. Auffallend war hierbei, dass die Al2O3-Löslichkeit bei GK4 ohne und mit geringer NaCl-Zugabe die mit Abstand höchsten Werte annimmt. Bei den zusätzlich durchgeführten Löseversuchen an den tomografierten Einzelkörnern in 1 M KOH-Lösung mit Zugabe von 1 M.-% NaCl zeigte sich, dass nur vereinzelt bei den untersuchten Gesteinsarten eine Korrelation zwischen dem SiO2- bzw. Al2O3-Gehalt im Eluat und der absoluten BET-Oberfläche nachweisbar ist. Dies ist vermutlich darauf zurückzuführen, dass neben der Oberfläche weitere Parameter (z.B. die mineralogische Zusammensetzung der Einzelkörner) das Löseverhalten maßgebend beeinflussen. Bei den parallel zu den Löseversuchen durchgeführten Betonversuchen nach dem ARS 04/2013 zeigte sich, dass die Alkaliempfindlichkeit der GK4 bei beiden Betonversuchen mit Alkalizufuhr unterschiedlich zu bewerten ist. So ist unabhängig von der vorgegebenen pessimalen Betonrezeptur des Fahrbahndeckenbetons ausschließlich bei der Klimawechsellagerung die GK4 als alkaliempfindlich einzustufen. Allerdings konnte der Befund der stark ausgeprägten AKR bei der GK4 mit der Dünnschliffmikroskopie nicht bestätigt werden. Analoges gilt für die Bewertung der Alkaliempfindlichkeit von GK2 mit den Betonversuchen nach der Alkalirichtlichtlinie des DAfStb. So ist auch hier die GK2 nicht im 60 °C-Betonversuch sondern ausschließlich im 40 °C-Betonversuch als alkaliempfindlich einzustufen.
Dienach den verschiedenartigen Betonversuchen durchgeführten LIBS-Analysen am Vertikalschnitt der Prüfkörper zeigen, dass im Kernbereich nach dem 60 °C-Betonversuch mit 10 %iger NaCl-Lösung und nach der Klimawechsellagerung mit NaCl-Beaufschlagung annähernd gleich hohe Natrium- und Chloridgehalte vorgefunden werden. Wider Erwarten treten an den beaufschlagten Prüfflächen Abreicherungen von Natrium und Anreicherungen von Chlorid auf. Im 40°C- und 60 °C-Betonversuch wurde das Natrium bis in eine maximale Tiefe von ca. 30 mm bzw. 20 mm ausgelaugt. Die aufbauenden korrelativen Betrachtungen zwischen den Ergebnissen des 60°C Betonversuchs mit Alkalizufuhr und der Löseversuche an den fraktionsspezifischen Korngemengen in 1 M KOH-Lösung mit definierter NaCl-Zugabe sind durchaus vielversprechend. So zeigt sich beispielsweise beim Waschbeton, dass der fraktionsspezifisch gewichtete SiO2-Überschuss im Eluat nach 56 Tagen mit Zugabe von 0,5 M.-% NaCl ohne Bezug auf die BET-Oberfläche zur gleichen Einstufung der vier betrachteten Gesteinskörnungen wie bei den Dehnungen im 60 °C-Betonversuch mit 3 %-iger NaCl-Lösung führt. Außerdem korrelieren die im 60 °C-Betonversuch mit 10 %-iger NaCl-Lösung ermittelten Dehnungen mit dem gewichteten SiO2-Überschuss im Eluat bei Zugabe von 2 M.-% NaCl ohne Bezug auf die BET-Oberfläche.
Ausschließlich bei den Betonversuchen nach der Alkali-Richtlinie erwies sich der Bezug des im Eluat ermittelten SiO2-Überschusses auf die BET-Oberfläche als zielführend. Aufgrund des Potenzials der Löseversuche mit NaCl-Zugabe für die Bewertung der Alkaliempfindlichkeit der Gesteinskörnung im Fahrbahndeckenbeton wird empfohlen, die vergleichenden Untersuchungen zwischen den Löseversuchen an Korngemischen der einzelnen Fraktionen und den Betonversuchen nach dem ARS 04/2013 mit einer möglichst hohen Anzahl an Gesteinskörnungen und einem präzisierten Untersuchungsumfang fortzuführen.
The dataset presented contains ultrasonic data recorded in pulse echo mode. The investigated specimen is made of the isotropic homogeneous material polyamide and has a drill hole of constant diameter running parallel to the surface, which was scanned in a point grid using an automatic scanner system. At each measuring position, a pitch-catch measurement was performed using a sampling rate of 2 MHz. The probes used are arrays consisting of a spatially separated receiving and in-phase transmitting unit. The transmitting and receiving sides each consist of 12 point-shaped single probes. These dry-point contact (DPC) probes operate according to the piezoelectric principle at nominal frequencies of 55 kHz (shear waves) and 100 kHz (longitudinal waves), respectively, and do not require a coupling medium. The measurements are performed with longitudinal (100 kHz) and transverse (55 kHz) waves with different geometric orientations of the probe on the measurement surface. The data presented in the article provide a valid source for evaluating reconstruction algorithms for imaging in the low-frequency ultrasound range.
Monitoring of repositories for radioactive waste requires techniques which can be applied long-term under harsh conditions. In this work, the reliability and suitability of materials and a capacitive sensor for measuring relative humidity are investigated, which are to be embedded in the special concrete components for the closure structures of underground repository. Preliminary tests with accelerated aging of the materials used, validation of the sensors under difficult conditions, investigations of the surfaces after aging by pH 14 solution, defined exposure of the sensors in a climatic chamber and the microscope images are discussed. The results will be used for further development and optimization of the RFID based sensor systems which can be applied to monitor the condition of different building structures without cabling.
This paper describes a new ultrasonic measuring device called “W-Box”. It was developed based on the requirements of the DFG Forschergruppe (research unit) CoDA for a portable device for monitoring of concrete specimens, models and actual structures using embedded ultrasonic transducers as well as temperature and humidity sensors. The W-Box can send ultrasonic pulses with a variable frequency of 50–100 kHz to one selectable transducer and records signals from up to 75 multiplexed channels with a sample rate of 1 MHz and a resolution of 14 bits. In addition, it measures temperature and humidity with high accuracy, adjustable amplification, restarts automatically after a power failure and can be fully controlled remotely. The measured data are automatically stored locally on-site data quality checks and transferred to remote servers. The comparison of the W-Box with a laboratory setup using commercial devices proves that it is equally reliable and precise, at much lower cost. The W-Box also shows that their measurement capacities, with the used embedded ultrasonic transducers, can reach above 6 m in concrete.
Zerstörungsfreie Prüfmethoden für Verschlussbauwerke nuklearer Endlager im Projekt SealWasteSafe
(2022)
Für die sichere Einlagerung von radioaktiven oder toxischen Abfällen kommen im Salzgestein technische Barrieren in Form von untertägigen Verschlussbauwerken zum Einsatz. Aufgrund der hohen Anforderungen an Sicherheit und Integrität dieser Verschlussbauwerke werden umfangreiche zerstörungsfreie Prüfmethoden zur Überwachung und Qualitätssicherung verwendet. Im BAM-Projekt SealWasteSafe werden Werkstofftechnik, Prüfverfahren und Überwachungsmethoden für sichere Verschlussbauwerke in Endlagern verbessert. Dabei wird der bisherige Salzbeton mit dem innovativen alkaliaktivierten Material (AAM) mit langsamerer Reaktionskinetik bei der Erhärtung und somit potenziell geringerer Rissbildung verglichen. Im Labormaßstab werden Probekörper mit Volumina von 100-300 l multisensorisch ausgestattet und somit die Zuverlässigkeit und Widerstandsfähigkeit der Sensoren gegenüber der hochalkalischen Umgebung nachgewiesen. Durch das Monitoring wird der Abbindevorgang des Betons überwacht und die Materialien über einen Zeitraum von mehreren Wochen charakterisiert. Dabei werden die Parameter Temperatur und Feuchtigkeit einerseits verkabelt als auch mittels drahtloser Radio Frequency Identification (RFID)-Technik aufgezeichnet. Zusätzlich kommen Schallemissionsmessungen sowie Dehnungsmessung mittels verteilter faseroptischer Sensorik (FOS) zum Einsatz. Das multisensorische Überwachungssystem wird durch aktive Ultraschallmessungen ergänzt, die durch die Detektion von Rissen, Delaminationen oder anderen Störstellen eine Qualitätssicherung der Verschlussbauwerke ermöglichen. Dafür werden sowohl ein Ultraschallsystem mit großer Apertur (LAUS) als auch eine Ultraschall-Bohrlochsonde eingesetzt. Durch Erhöhung des Schalldrucks und Bündelung der Schallsignale im Beton wird die Aussagekraft der von der Bohrlochsonde aufgezeichneten Messsignale verbessert, was in Modellierungen und ersten Labortests gezeigt werden kann. Die Auswertung der Ultraschallmessungen erfolgt mit auf Diffraktionssummation beruhenden Migrationsverfahren wie Kirchhoff-Tiefenmigration und Synthetic Aperture Focusing Technique (SAFT), die Abbildungen vom Inneren der Probekörper erzeugen. Insgesamt verbessert das Projekt SealWasteSafe mithilfe innovativer Multisensorik und Ultraschallmethodik die Überwachungs- und Qualitätssicherungskonzepte für sichere Verschlussbauwerke nuklearer Endlager.
Das vorliegende Arbeitspapier stellt den Stand des Wissens und der Forschung zum Einsatz von Sensorik in Straßenbefestigungen zur Erfassung von Eingangsgrößen und Merkmalen für die Substanzbewertung zusammenfassend dar. Unter Sensorik versteht dieses Arbeitspapier ganz allgemein technische Einrichtungen, mit denen man die Werte von physikalischen Größen erfassen und zur Interpretation darstellen kann.
A novel ultrasonic borehole probe is developed for the quality assurance of sealing structures in radioactive waste repositories using existing research boreholes. The aim is to analyse the sealing structures made of salt concrete concerning potential cracks, delamination, and embedded objects. A first prototype of the probe uses 12 individual dry point contact (DPC) shear horizontal wave transducers separated by equidistant transmitter/receiver arrays, each consisting of six individual transducers. It is operated with a commercial handheld ultrasonic testing device used in civil engineering. In order to increase the generated sound pressure of the borehole probe, the number of transducers will be increased to 32 for the novel probe. In addition, a time-controlled excitation of the individual probes is used to steer a focused sound beam to a certain angle and focus on a certain distance based on calculated time delays. Hence, the sensitive test volume is more limited, and the signal-to-noise ratio of the received signals improved. This paper presents the validation of the newly developed phased array borehole probe by beam simulation and experimentally on a half-cylindrical test specimen to investigate the directional characteristics. In combination with geophysical reconstruction method, an optimised radiation characteristic of the probe, an improved signal quality and thus an increased reliability of the results in imaging is expected. This is of great importance to construct safe sealing structures needed for radioactive or toxic waste disposal.
A novel ultrasonic borehole probe is developed for the quality assurance of sealing structures in radioactive waste repositories using existing research boreholes. The goal is to examine the sealing structures made of salt concrete for possible cracks, delamination, and embedded objects. A prototype probe uses 12 individual horizontal dry point contact (DPC) shear wave transducers separated by equidistant transmitter/receiver arrays of six individual transducers each. It is operated with a commercially available portable ultrasonic flaw detector used in the civil engineering industry. To increase the generated acoustic pressure of the borehole probe, the number of transducers in the novel probe is increased to 32. In addition, a timed excitation of each probe directs a focused beam of sound to a specific angle and distance based on calculated time delays. This limits the sensitive test volume and improves the signal-to-noise ratio of the received signals. This paper presents the validation of the newly developed phased array borehole probe by investigating the directivity through beam computation in the CIVA software and experimental investigations on a semi-cylindrical test specimen. It is expected that an optimised radiation pattern of the probe in combination with geophysical reconstruction methods will improve the signal quality and thus increase the reliability of the imaging results. This is of great importance for the construction of safe sealing structures needed for the disposal of radioactive or toxic waste.
Development of an Accurate and Robust Air-Coupled Ultrasonic Time-of-Flight Measurement Technique
(2022)
Ultrasonic time-of-flight (ToF) measurements enable the non-destructive characterization of material parameters as well as the reconstruction of scatterers inside a specimen. The time-consuming and potentially damaging procedure of applying a liquid couplant between specimen and transducer can be avoided by using air-coupled ultrasound. However, to obtain accurate ToF results, the waveform and travel time of the acoustic signal through the air, which are influenced by the ambient conditions, need to be considered. The placement of microphones as signal receivers is restricted to locations where they do not affect the sound field. This study presents a novel method for in-air ranging and ToF determination that is non-invasive and robust to changing ambient conditions or waveform variations. The in-air travel time was determined by utilizing the azimuthal directivity of a laser Doppler vibrometer operated in refracto-vibrometry (RV) mode. The time of entry of the acoustic signal was determined using the autocorrelation of the RV signal. The same signal was further used as a reference for determining the ToF through the specimen in transmission mode via cross-correlation. The derived signal processing procedure was verified in experiments on a polyamide specimen. Here, a ranging accuracy of <0.1 mm and a transmission ToF accuracy of 0.3μs were achieved. Thus, the proposed method enables fast and accurate non-invasive ToF measurements that do not require knowledge about transducer characteristics or ambient conditions.
Mit dem zerstörungsfreien Verfahren der nuklear magnetischen Resonanz (NMR) mit Fokus auf 1H-Protonen lässt sich der Feuchtegehalt in porösen Materialien bestimmen und bei einem vollgesättigten Medium eine Porengrößenverteilung ableiten. Für die Ermittlung der Porengrößenverteilung muss die gemessene T2-Relaxationszeitenverteilung mit dem Parameter Oberflächenrelaxivität (OR) umgerechnet werden. Ist dieser Parameter für das zu untersuchende Medium unbekannt, kann dieser mithilfe von Vergleichsverfahren abgeschätzt werden. Dabei kommen z. B. Gassorption, Quecksilberporosimetrie (MIP), Dünnschliff-Mikroskopie oder µ-Computer-Tomographie (µ-CT) zum Einsatz. Da die verschiedenen Verfahren allerdings unterschiedliche Auflösungsgrenzen aufweisen und auf verschiedenen physikalischen Prinzipien beruhen, können die ermittelten ORs für ein Medium stark variieren. Um ein besseres Verständnis für die OR und die Einflüsse der Vergleichsverfahren zu bekommen, wurden 19 verschiedene Sandsteintypen untersucht. Die OR wurde zum einen basierend auf der spezifischen inneren Oberfläche aus der dynamischen Dampfsorption (DVS) und der Gassorption abgeleitet. Zum anderen wurden die Relaxationszeitenverteilungen durch manuelles Anpassen der OR derart in Porengrößenverteilungen umgerechnet, sodass es eine Übereinstimmung mit den Porengrößenverteilungen aus MIP und/oder µ-CT gibt. Die Umrechnung von Relaxationszeitverteilungen in eine Porengrößenverteilung berücksichtigt dabei sowohl fast- als auch slow-diffusion. Insgesamt ergab sich für die Sandsteine ein breites Spektrum an ORs, bei dem die über die innere spezifische Oberfläche ermittelten ORs andere Größenordnungen aufwiesen (< 10 µm/s), als bei dem Vergleich mit MIP oder µ-CT (bis 600 µm/s). Die mit MIP und µ-CT ermittelten Werten lagen dabei um einen Faktor von 1 bis 30 auseinander. Dieser umfangreiche Datensatz, der vier verschiedene Vergleichsverfahren einbezieht, soll neue Erkenntnisse in der Charakterisierung von porösen Materialien (z. B. bezüglich der Oberflächenrauigkeit) und in der Ursache für die starke Variation der OR ermöglichen. Durch das Berücksichtigen von fast- als auch slow-diffusion, können dabei sogar Daten in eine Porengrößenverteilung umgerechnet werden, bei denen das fast-diffusion-Kriterium nach Brownstein und Tarr nicht erfüllt ist. Außerdem ergibt sich aus der Berücksichtigung des slow-diffusion-Regimes ein neues Verständnis für die obere Auflösungsgrenze von NMR.
Reliable assessment of earthen dams’ stability and tailing storage facilities widely used in the mining industry is challenging, particularly under seismic load conditions. In this paper, we propose to take into account the effect of the dominant frequency of seismic load on the stability assessment of tailing/earthen dams. The calculations are performed by finite element modelling (FEM) with the Mohr–Coulomb failure criteria. To separate the frequency content from other dynamic parameters describing the seismic wave, synthetic waveforms with identical amplitude and attenuation characteristics, but differing spectral characteristics have been used. The analysis has been performed for three different slope angles and two scenarios of seismic wave propagation. Consequently, the changes of total displacement and shear stresses depending on the frequencies have been determined and clearly show that lower frequencies cause higher stress levels and displacement. Finally, the response surface methodology has been applied to determine how different parameters affect the slope stability under dynamic load conditions. Overall, this study is a first step to improve the existing methods to assess slope stability when considering seismic load.
Damage detection of reinforced concrete (RC) structures is becoming a more attractive domain due to the safety issues arising in the last few decades. The damage in concrete can be caused by excessive exploitation of the structure or environmental effects. The cracks in concrete can be detected by different nondestructive testing methods. However, the available methods used for this purpose have numerous limitations. The technologies available in the market nowadays have difficulties detecting slowly progressive, locally limited damage. In addition, some of These methods cannot be applied, especially in hard-to-reach areas in the superstructures. In order to avoid these deficiencies, an embedded ultrasonic methodology can be used to detect cracks in RC structures. In this study, the methodology of crack detection supported with the advanced Signal processing algorithm was proposed and verified on RC structures of various types, and cracks occurring between embedded sensors can be detected. Moreover, different pairs of ultrasonic sensors located in the considered structures are used for the analysis of the sensitivity of distance between them. It is shown that the ultrasonic sensors placed in the range of 1.5–2 m can detect cracks, even when the other methods failed to detect changes in the structure. The obtained results confirmed that diffuse ultrasonic sensor methodology is able to monitor real structures more effectively than traditional techniques.
Integration of fiber reinforcement in high-performance cementitious materials has become widely applied in many fields of construction. One of the most investigated advantages of steel Fiber reinforced concrete (SFRC) is the deceleration of crack growth and hence its improved sustainability.
Additional benefits are associated with its structural properties, as fibers can significantly increase the ductility and the tensile strength of concrete. In some applications it is even possible to entirely replace the conventional reinforcement, leading to significant logistical and environmental benefits.
Fiber reinforcement can, however, have critical disadvantages and even hinder the Performance of concrete, since it can induce an anisotropic material behavior of the mixture if the fibers are not appropriately oriented. For a safe use of SFRC in the future, reliable non-destructive testing (NDT) methods need to be identified to assess the fibers’ orientation in hardened concrete. In this study,
ultrasonic material testing, electrical impedance testing, and X-ray computed tomography have been investigated for this purpose using specially produced samples with biased or random Fiber orientations. We demonstrate the capabilities of each of these NDT techniques for fiber orientation measurements and draw conclusions based on these results about the most promising areas for future research and development.
Für die Qualitätssicherung von neuen Fundamenten steht eine Reihe von zerstörungsfreien Prüfverfahren zur Verfügung. Das Portfolio reicht von der einfachen Hammerschlagmethode („Pfahlintegritätsprüfung“) bis zu aufwändigen Ultraschallverfahren für meterstarke Fundamentplatten. Aber funktionieren die Verfahren auch im Bestand? Lassen sich die für Wieder-, Um- und Weiternutzung notwendigen Daten erfassen? Und wie werden die zerstörungsfreien Prüfverfahren erfolgreich in Untersuchungskonzepte integriert? Dies wird vor allem am Beispiel der Fundamente von Freileitungsmasten diskutiert.
The integral collection of information such as strains, cracks, or temperatures by ultrasound offers the best prerequisites to monitor structures during their lifetime. In this paper, a novel approach is proposed which uses the collected information in the coda of ultrasonic signals to infer the condition of a structure. This approach is derived from component tests on a reinforced concrete beam subjected to four-point bending in the lab at Ruhr University Bochum. In addition to ultrasonic measurements, strain of the reinforcement is measured with fiber optic sensors. Approached by the methods of moment-curvature relations, the steel strains serve as a reference for velocity changes of the coda waves. In particular, a correlation between the relative velocity change and the average steel strain in the reinforcement is derived that covers 90% of the total bearing capacity. The purely empirical model yields a linear function with a high level of accuracy (R 2 =0.99, R2=0.99, RMSE≈90μ
RMSE≈90μ strain).
Ultrasonic testing is a widely applied measurement method in materials research and medicine. Commonly, a transducer is coupled to the specimen directly or via a liquid coupling agent. While reducing acoustic transmission losses significantly, this procedure is time-consuming and cannot be used for sensitive specimens. Air-coupled ultrasound is a viable alternative in such cases, although suffering from very high acoustic transmission losses between transducer, air and specimen. The recently introduced fluidic transducer (FT) generates ultrasound by utilizing the instability of a supersonic air jet switched inside a fluidic amplifier. Since only air is used as the working medium and no vibrating surfaces are used for ultrasound generation, the transducer is able to efficiently generate large acoustic pressure amplitudes. The resulting acoustic field shares its directivity with the ejected high-velocity air jet. Thus, the acoustic energy needs to be redirected from the jet axis in order to make the fluidic transducer applicable to sensitive specimens. In this study, the effectivity of using sonic crystals (SCs) for this redirection is investigated using acoustic and flow measurements. SCs are air-permeable while being reflective to large acoustic frequency bands. It was shown that both a defect waveguide and a mirroring strategy successfully redirected the acoustic field from the air jet. Furthermore, the interaction of flow and SC showed strong acoustic quenching if the SC was placed too close to the FT outlet. Blockage of the jet entrainment due to the SC may result in slightly higher off-axis flow velocities locally, which should be considered in sensitive applications.
Ultrasonic monitoring, making use of the sensitivity of the coda of repeated transmission meas-urements to changes in stress, temperature, moisture, as well as localized or distributed damage, has gotten at-tention in structural health monitoring (SHM) research recently. Analysis methods such as coda wave inter-ferometry (CWI), including its nonlinear extension, have been shown to be able to measure ultrasonic wave velocity changes with a 1∙10-5 resolution, while indicators such as cross-correlation or cross-coherence have been used to distinguish between reversible and irreversible changes. Several small- and large-scale laboratory experiments have demonstrated that stress changes in structures can be captured or damage detected in a very early stage. The use of this technique for pre-warning before failure are currently under investigation, as well as detailed research on the physical causes and the connection between ultrasonic wave properties and materi-al/structural behavior. Recently, several of large-scale laboratory and real structures have been instrumented with embedded ultrasonic transducers to gather experience and evidence on how to use this technology in re-al-world applications. Preliminary results from installations on a new bridge, an existing bridge, a tunnel, a la-boratory earthquake test as well as a historic stadium in Germany, Poland, and the United States, respectively, are presented. Environmental influences (mainly temperature) and validation by load tests are discussed.
Ultrasonic monitoring, making use of the sensitivity of the coda of repeated transmission meas-urements to changes in stress, temperature, moisture, as well as localized or distributed damage, has gotten at-tention in structural health monitoring (SHM) research recently. Analysis methods such as coda wave inter-ferometry (CWI), including its nonlinear extension, have been shown to be able to measure ultrasonic wave velocity changes with a 1∙10-5 resolution, while indicators such as cross-correlation or cross-coherence have been used to distinguish between reversible and irreversible changes. Several small- and large-scale laboratory experiments have demonstrated that stress changes in structures can be captured or damage detected in a very early stage. The use of this technique for pre-warning before failure are currently under investigation, as well as detailed research on the physical causes and the connection between ultrasonic wave properties and materi-al/structural behavior. Recently, several of large-scale laboratory and real structures have been instrumented with embedded ultrasonic transducers to gather experience and evidence on how to use this technology in re-al-world applications. Preliminary results from installations on a new bridge, an existing bridge, a tunnel, a la-boratory earthquake test as well as a historic stadium in Germany, Poland, and the United States, respectively, are presented. Environmental influences (mainly temperature) and validation by load tests are discussed.
Zu jedem Endlager gehört die Entwicklung eines Verschlusskonzept. Im Endlager Morsleben und an anderer Stelle werden in Abhängigkeit vom Wirtsgestein verschiedene Materialien und Bauweisen für Streckenverschlüsse entwickelt und in großem Maßstab erprobt. Hierzu gehören auch Maßnahmen der Qualitätssicherung, die Informationen über Ausführung und Zustand der Versuchsbauwerke liefern. Hierzu werden von der Bundesanstalt für Materialforschung und -prüfung (BAM) für verschiedene Forschungsvorhaben und Prüfaufträge Methoden und Geräte getestet, verbessert und vor Ort unter Tage eingesetzt Die hier beschriebenen Verfahren lassen sich auch zu Untersuchungen im Wirtsgestein anwenden.
Zu jedem Endlager gehört die Entwicklung eines Verschlusskonzept. Im Endlager Morsleben und an anderer Stelle werden in Abhängigkeit vom Wirtsgestein verschiedene Materialien und Bauweisen für Streckenverschlüsse entwickelt und in großem Maßstab erprobt. Hierzu gehören auch Maßnahmen der Qualitätssicherung, die Informationen über Ausführung und Zustand der Versuchsbauwerke liefern. Hierzu werden von der Bundesanstalt für Materialforschung und -prüfung (BAM) für verschiedene Forschungsvorhaben und Prüfaufträge Methoden und Geräte getestet, verbessert und vor Ort unter Tage eingesetzt. Die hier beschriebenen Verfahren lassen sich auch zu Untersuchungen im Wirtsgestein anwenden.
NDE 4.0 in Civil Engineering
(2021)
Civil engineering industry is one of the most important industry sectors in the worldwide economy. It contributes significantly to the gross economic product and general employment. Even more important, it provides many of the basic needs of the society (e.g., housing, infrastructure, and protection from natural hazards). The concept of “Industry 4.0” or “Smart Production” has not yet made significant progress in the civil engineering industry. The designing, building, and operating processes are still widely dominated by the exchange of printed documents and drawings. Most objects (buildings and other constructions) are unique, and a large part of the production still requires a large amount of manual labor. As-built documentation and quality assurance are often neglected. Civil engineering is among the industry sectors with the lowest level of digitalization and the lowest gain in productivity. However, this is going to change. In the past decade, several drivers have challenged the ways clients, contractors, and authorities currently operate. These drivers include but are not limited to an increasing demand for serialization and automatization or the mandatory introduction of “Building Information Modeling” (BIM) in public procurement as well as the upcoming use of digital twins. NDE plays an increasing role in quality assurance, condition assessment, and monitoring of structures. However, with very few exceptions, applications are mostly nonstandardized and performed only at selected sites. To change this, the NDT-CE community including manufacturers, service providers, clients, and the scientific community must work consistently on open data formats, interfaces to BIM, standardization, and validated ways for a quantitative use of the results in the assessment of constructions.
Acoustic emission and ultrasonic monitoring of a prestressed concrete bridge in its final years
(2021)
Many European bridges built in the 1950s, 60s and 70s must be re-placed in the next decade due to structural deficiencies, insufficient load capacity or other issues. However, the existing bridges must be used for another couple of years even if flaws and damages already have been detected.
In Germany, several prestressed concrete bridges have been instrumented with acoustic emission detection systems to detect wire breaks and to provide early warning signs before failure. To evaluate and interpret the consequences of wire breaks additional instrumentation and accompanying measures as finite element modeling are required.
At a bridge in southern Germany we have complemented such a system with active ultrasonic monitoring. Repeated ultrasonic measurements are evaluated with a very sensible algorithm called coda wave interferometry. This method, inspired by seismology, has been shown to deliver early warning signs in lab experiments. Large volumes of concrete can be monitored with a limited network of ultrasonic transducers. We will report on the installation, capabilities, and lim-itations as well as first results.
Non-destructive testing methods are available in civil engineering for decades to estimate concrete properties or to detect flaws and features. But recently we have seen the dawn of next-generation tools, methods, and applications. Some of them will be discussed in the web talk: – Better tools: deeper and more detailed insight into concrete constructions – Better methods: Quantitative use in probabilistic structural assessment – Better rules: Towards standardization, qualification, and certification – Better application: Digitalization and Elimination of the boundaries between NDT, SHM, and BIM: NDT-CE 4.0 Not enough? I might show, how cosmic rays might become a game-changer in NDT-CE. This live webinar record was provided by https://eurostruct.org
The EURATOM PREDIS project (http://www.predis-h2020.eu, last access:TS1) targets the development and implementation of activities for predisposal treatment of radioactive waste streams other than nuclear fuel and high-level radioactive waste. It started on 1 September 2020 with a 4 year duration. The consortium includes 47 partners from 17 member states. The overall budget of the project is EUR23.7 million, with EC contribution of EUR 14 million. The PREDIS project develops and increases the technological readiness level (TRL) of treatment and conditioning methodologies for wastes for which no adequate or industrially mature Solutions are currently available, including metallic materials, liquid organic waste and solid organic waste. The PREDIS project also develops innovations in cemented waste handling and predisposal storage by testing and evaluating.
The technical work packages align with priorities formulated within the Roadmap Theme 2 of EURAD (https://www.ejp-eurad.eu/TS2), Nugenia Global Vision (https://snetp.eu/nugenia/TS3) and with those identified by the project’s industrial end users group (EUG). The PREDIS will produce tools guiding decision making on the added value of the developed technologies and their impact on the design, safety and economics of waste management and disposal.
Four technical work packages are focusing on specific waste types: metallic, liquid organic, solid organic, and cemented wastes. For the first three, the main aim lies in processing, stabilizing, and packaging the different waste streams, e.g. by using novel geopolymers, to deliver items which are in line with national and international waste acceptance criteria. In contrast, the fourth technical work package has a different focus.
To provide better ways for a safe and effective monitoring of cemented waste packages including prediction tools to assess the future integrity development during predisposal activities, several digital tools are evaluated and improved. Safety enhancement (e.g. less exposure of testing personnel) and cost-effectiveness are part of the intended impact. The work includes but is not limited to inspection methods, such as muon imaging, wireless sensors integrated into waste packages as well as external package and facility monitoring, such as remote Fiber optic sensors. The sensors applied will go beyond radiation monitoring and include proxy parameters important for long-term integrity assessment (e.g. internal pressure). Sensors will also be made cost-effective to allow the
installation of many more sensors compared to current practice. The measured data will be used in digital Twins of the waste packages for specific simulations (geochemical, integrity) providing a prediction of future behavior.
Machine learning techniques trained by the characterization of older waste packages will help to connect the models to the current data. All data (measured and simulated) will be collected in a joint database and connected to a decision framework to be used at actual facilities.
The presentation includes detailed information about the various tools under consideration in the Monitoring of cemented waste packages, their connection and first results of the research.
To provide better means for a safe and effective monitoring of cemented waste packages including prediction tools to assess the future integrity development during pre-disposal activities, several digital tools are evaluated and improved in the frame of the EC funded project PREDIS. Safety enhancement (e. g. less exposure of testing personnel) and cost effectiveness are part of the intended impact. The work includes but is not limited to inspection methods such as muon imaging, wireless sensors integrated into waste packages as well as external package and facility monitoring such as remote fiber optical sensors. The sensors applied will go beyond radiation monitoring and include proxy parameters important for long term integrity assessment (e. g. internal pressure). Sensors will also be made cost effective to allow the installation of much more sensors compared to current practice. The measured data will be used in digital twins of the packages for specific simulations (geochemical, integrity) providing a prediction of future behavior. Machine Learning techniques trained by the characterization of older packages will help to connect the models to the actual data. All data (measured and simulated) will be collected in a joint data base and connected to a decision framework to be used at actual facilities. The paper includes detailed information about the various tools under consideration, their connection and first results of our research.
"The reassessment of bridges continues to take great importance both nationally and internationally. A major challenge is to find computation models reflecting the actual properties of the considered structures sufficiently accurate. Besides regular inspections, the conduction of advanced measurements is suitable to generate reliable information about a structure to be assessed. Prior to incorporating measurement results in reassessment, the relevance, the trueness, and the precision of the measured information needs to be stated. On the one hand, the use of information whose quality has not been assessed can lead to errors with serious consequences. On the other, the measurement of irrelevant information is inefficient. Although the use of measured data in assessment is currently mostly unregulated, their appreciation in reliability analyses is beneficial since the built environment can be assessed more realistically. Utilizing NDT in reassessment has the potential to extend remaining lifetimes of a structure, save resources, and improve infrastructural availabilities. The power of judgment regarding the decision on the reliability of an existing structure can be increased.
In this contribution, an approach is outlined to process non-destructively gathered measurement data in a comparableway in order to include themeasured information in probabilistic reliability assessments of existing structures. An essential part is the calculation of measurement uncertainties. The effect of incorporating evaluated NDT-results is demonstrated by means of a prestressed concrete bridge and GPR measurements conducted on this bridge as a case-study. The bridge is assessed regarding SLS Decompression using the NDT-results."