8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen
Filtern
Dokumenttyp
- Vortrag (181)
- Zeitschriftenartikel (107)
- Beitrag zu einem Tagungsband (80)
- Posterpräsentation (62)
- Sonstiges (9)
- Buchkapitel (8)
- Forschungsdatensatz (8)
- Beitrag zu einem Sammelband (3)
- Forschungsbericht (3)
- Dissertation (2)
Sprache
- Englisch (342)
- Deutsch (121)
- Mehrsprachig (1)
Schlagworte
- Concrete (99)
- Ultrasound (86)
- LIBS (62)
- Monitoring (53)
- Non-destructive testing (37)
- Beton (28)
- Ultraschall (28)
- Zerstörungsfreie Prüfung (27)
- NDT (26)
- Coda wave interferometry (21)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (464)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (464)
- 7 Bauwerkssicherheit (37)
- 8.0 Abteilungsleitung und andere (30)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (20)
- 8.6 Faseroptische Sensorik (16)
- 7.4 Baustofftechnologie (15)
- 1 Analytische Chemie; Referenzmaterialien (10)
- 8.5 Röntgenbildgebung (10)
- 7.1 Baustoffe (9)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (181)
The Infrastar training school provides lectures and hands-on training to Master and PhD students, early-stage researchers and (young) professionals on all aspects of asset management of civil infrastructures with respect to fatigue of materials. It is organized yearly since 2019 and up to 20 profiles are selected to attend the 3.5-day training.
A team of 7 teachers provides insight in multi-disciplinary and intersectoral basic concepts in three core fields, ranging from the design to the dismantling of the structures (bridges and wind turbines):
1. Monitoring and auscultation,
2. Structural and action models,
3. Reliability, risk and decision analyses.
Each year, a recognized expert is invited to deliver a keynote lecture to raise interest in a specific aspect of one of the fields covered. The presentation is recorded and published on the training school website.
"INFRASTAR aims to develop knowledge, expertise and skills for optimal and reliable management of structures. The generic methodology is applied to bridges and wind turbines in relation to fatigue offering the opportunity to deal with complementary notions (such as old and new asset management, unique and similar structures, wind and traffic actions) while addressing 3 major challenges: 1/ advanced modelling of concrete fatigue behaviour, 2/new non destructive testing methods for early aged damage detection and 3/probabilistic approach of structure reliability under fatigue. Benefit of cross-experience and inter-disciplinary synergies creates new knowledge. INFRASTAR proposes innovative solutions for civil infrastructure asset management so that young scientists acquire a high employment profile in close dialogue between industry and academic partners. Modern engineering methods, including probabilistic approaches, risk and reliability assessment tools, will take into account the effective structural behaviour of existing bridges and wind turbines by exploiting monitored data. Existing methods and current state-of -the art is based on excessive conservatism which produces high costs and hinders sustainability. INFRASTAR improves knowledge for optimising the design of new structures, for more realistic verification of structural safety and more accurate prediction of future lifetime of the existing structures. That is a challenge for a sustainable development because it reduces building material and energy consumption as well as CO2 production. Within the global framework of optimal infrastructure asset management, INFRASTAR will result in a multi-disciplinary body of knowledge covering generic problems from the design stage process of the new civil infrastructures up to recycling after dismantlement. This approach and the proposed methods and tools are new and allow a step forward for innovative and effective process."
Fatigue is one of the most prevalent issues, which directly influences the service life expectancy of concrete structures. Fatigue has been investigated for years for steel structures. However, recent findings suggest that concrete structures may also be significantly subjected to the fatigue phenomena that could lead to premature failure of certainfatigue prone structural elements. To date, fatigue of reinforced concrete has been given little focus. and Kknowledge on the influence factors and durability/capacity effects on this material should be improved. Current technological means to measure fatigue in civil structures like bridges and wind turbines (both onshore and offshore) are outdated, imprecise and inappropriate.
Meanwhile, this topic has got much more attention as dynamic loading on concrete structures plays an increasing role, e.g. in bridges with increasing traffic and heavier trucks, in wind energy production due to inherent vibrations e.g. in offshore wind turbine support structures affected by wind and waves.
The European Innovative Training Networks (ITN) Marie Skłodowska-Curie Actions project INFRASTAR (Innovation and Networking for Fatigue and Reliability Analysis of Structures - Training for Assessment of Risk) provides research training for 12 PhD students. The project aims to improve knowledge for optimizing the design of new structures as well as for more realistic verification of structural safety and more accurate prediction of the remaining fatigue lifetime of existing structures.
First, the INFRASTAR research framework is detailed. Then it will be exemplified through the presentation of the major results of the four PhD students involved in the work package dealing with auscultation and monitoring. This includes the development and improvement of Fiber Optics (FO) and Coda Wave Interferometry (CWI) for crack sizing and imagery, new sensor technologies and integration, information management, monitoring strategy for fatigue damage investigation and lifetime prediction.
Fatigue is one of the most prevalent issues, which directly influences the service life expectancy of concrete structures. Fatigue has been investigated for years for steel structures. However, recent findings suggest that concrete structures may also be significantly subjected to fatigue phenomena that could lead to premature failure of certain structural elements. To date, fatigue of reinforced concrete has been given little focus. Knowledge on the influence factors and durability/capacity effects on this material should be improved. Current technological means to measure fatigue in civil structures like bridges and wind turbines (both onshore and offshore) are outdated, imprecise and inappropriate.
Meanwhile, this topic has got much more attention as time-variant loading on concrete structures plays an increasing role, e.g. in bridges with increasing traffic and heavier trucks, and for wind turbines for renewable energy production, e.g. for offshore wind turbine support structures affected by wind and waves.
The European Innovative Training Networks (ITN) Marie Skłodowska-Curie Actions project INFRASTAR (Innovation and Networking for Fatigue and Reliability Analysis of Structures - Training for Assessment of Risk) provides research training for 12 PhD students. The project aims to improve knowledge for optimizing the design of new structures as well as for more realistic verification of structural safety and more accurate prediction of the remaining fatigue lifetime of existing concrete structures.
First, the INFRASTAR research framework is detailed. Then it will be exemplified through the presentation of the major results of the four PhD students involved in the work package dealing with auscultation and monitoring. This includes the development and improvement of Fiber Optics (FO) and Coda Wave Interferometry (CWI) for crack sizing and imagery, new sensor technologies and integration, information management, monitoring strategy for fatigue damage investigation and lifetime prediction.
The Infrastar training school provides lectures and hands-on training to Master and PhD students, early-stage researchers and (young) professionals on all aspects of asset management of civil infrastructures with respect to fatigue of materials. It is organized yearly since 2019 and up to 20 profiles are selected to attend the 3.5-day training.
A team of 7 teachers provides insight in multi-disciplinary and intersectoral basic concepts in three core fields, ranging from the design to the dismantling of the structures (bridges and wind turbines):
1. Monitoring and auscultation,
2. Structural and action models,
3. Reliability, risk and decision analyses.
Each year, a recognized expert is invited to deliver a keynote lecture to raise interest in a specific aspect of one of the fields covered. The presentation is recorded and published on the training school website.
A safety or security related assessment of explosions, accidental and intentional scenarios alike, often necessitate performance of replication-tests. Such test results are necessary to clarify the causes within the scope of forensic investigations. To gain important insights into the behavior of structures and materials under such loading, field tests may also be performed in accordance with different test standards. To determine the resistance of building-structures after explosions, estimation of the residual load-bearing capacity in addition to the assessment of dynamic structural response and damage to the building components is important. In most cases an evaluation of structural integrity is based only on the visual damage, resulting in an overestimation of the residual capacity.
The Bundesanstalt für Materialforschung und -prüfung (BAM) operates the Test site for Technical Safety (TTS) on an area measuring about 12 km2 in the Federal State of Brandenburg for execution of true-to-scale explosion tests. At the TTS, building component testing was performed to assess the suitability of different non-destructive testing methods to characterize the dynamic structural response and damage resulting from the detonation of high explosives.
Different blast-loading scenarios were realized by varying the net explosive mass and the standoff distance with all scenarios representing a near-field detonation. The test object was a reinforced concrete wall 2 m high, 2.5 m wide and 20 cm thick, fixed at both vertical edges. The dynamic loading of the wall was characterized with 8 piezoelectric pressure sensors flush-mounted on the front surface, thus measuring the reflected pressures from the shock wave. The tests were conducted with the aim of characterizing the global behavior of the wall under dynamic shock loading and the resulting local damage pattern, respectively. High speed digital image correlation was implemented in combination with multiple acceleration sensors to observe the rear surface of the wall to chart the dynamic deflection during the loading and to determine the residual deformation after the loading had ceased. In addition, one test specimen was instrumented with fiber optic sensor cables, both fixed to the rebars and embedded in the concrete-matrix, respectively. Firstly, these sensors were interrogated during the blast test by a distributed acoustic sensing (DAS) device using a particularly high sampling rate to measure the shock-induced vibrations in the structure with high temporal resolution. This delivers information on dynamics of compression and tension cycles from within the structure. Secondly, the local damage-pattern emerging during the series of blasts was determined via distributed fiber optic strain sensing (DSS) by interrogating the embedded fiber optic sensors with a high spatial resolution DSS device after each blast. This enabled the characterization of non-visual damage to the structure, in particular with regard to the formation of localized cracks in the concrete matrix. The DSS was further complimented by a structure-scanner based on ultrasonic measurements.
Our contribution describes this new test approach in detail. Results of the three datasets, namely dynamic shock loading, global behavior of the test object and the local damage pattern will be presented. The suitability of the implemented measurement methods will be discussed in combination with the challenges in their application for technical safety evaluation of building components under explosive loading.
Construction methods, environmental stressors, and aging factors are the main causes for defects of reinforced concrete in nuclear power plants (NPP). These defects are typically occurred as corrosion of reinforcement steel, delamination, cracks, malfunction of post-tensioning or steel composite systems etc. Some of the challenges for assessing the performance of these structures by nondestructive testing methods (NDT) are that the assessment could be performed only during the annual overhauls when testing is time-limited and uncertainty of the accuracy and reliability of the available NDT testing devices combined with the lack of the international uniformity of the methods used for NDT tests. To overcome these challenges, a mock-up wall representing a section of the concrete containment of the NPP was built. The mock-up wall included simulated defects, which mimic the most common types of defects in NPP concrete structures such as dimensional errors, honeycombing, delamination, defects adjacent to the steel liner and voids in grouted tendon ducts for the post-tensioned structures. This paper introduces the design and construction of the wall including the concrete properties, reinforcement, tendon ducts and the types of the simulated defects. The paper also introduces the NDT methods and techniques that are suitable for assessing the condition of the mock-up wall under the real environmental conditions. These techniques include mechanical methods as rebound hammer, ultrasonic and electromagnetic methods. This mock-up wall will enable to investigate reliably available NDT methods and experts’ skills providing also an important and very much need educational platform for future NDE experts.
Stahlbetontragwerke sind eine wichtige Konstruktionsweise im Bauwesen und ein wachsendes Anwendungsfeld für die Zerstörungsfreie Prüfung (ZfP).
Zur Sicherung der Tragsicherheit, strukturellen Integrität, Bestimmung von Geometrien und zur Detektion konstruktiver Elemente wie z.B. Bewehrung, Verankerungen und Spannkanälen besitzen zerstörungsfreie Prüfverfahren in diesem Bereich inzwischen große Relevanz. Durch den bislang erreichten Fortschritt in der Forschung und Entwicklung haben moderne akustische und elektromagnetische Verfahren eine beachtliche Leistungsfähigkeit erreicht. Von Geräteherstellern sind diese in kommerziellen Produktserien umgesetzt worden und finden eine zunehmend breite Anwendung in der Praxis. In einigen anderen Anwendungsgebieten, in denen die ZfP bereits fester Bestandteil von Überwachungen ist, wie z.B. im Maschinenbau und insbesondere in der Kerntechnik und der Luftfahrt, existieren umfangreiche Qualitätssicherungssysteme für die konforme Anwendung und zuverlässige Einbeziehung der ZfP. Dem relativ jungen Entwicklungsstadium moderner ZfP für Stahlbetonbauteile entsprechend müssen solche Konzepte im Bauwesen erst noch entwickelt bzw. implementiert werden.
Dementsprechend hat sich der Unterausschuss Qualitätssicherung (UA- S) des Fachausschusses ZfP im Bauwesen (ZfPBau) die Definition und Verbesserung der Qualität von ZfP-Anwendungen sowie insbesondere die verfahrensunabhängige Standardisierung von Prüfprozeduren und statistische Absicherung der Prüfergebnisse zum Ziel gemacht.
Die aktuellen Arbeitsfelder beinhalten die Entwicklung praxisgerechter Konzepte für Prüfprozeduren und deren Erprobung in einem Ringversuch sowie die Konzeption von Testkörpern hinsichtlich unterschiedlicher Aspekte wie Parameterstudien, Validierung, Kalibrierung und Simulation. Dabei werden Ansätze anderer Branchen durchaus einbezogen, die Anpassung an die spezifischen Bedürfnisse und Gegebenheiten des Bauwesens wird jedoch als wesentlich angesehen und stellt somit eine wichtige Vorgabe dar.
Da die Tätigkeiten nicht auf einzelne Verfahren begrenzt sind, müssen generelle Vorgehensweisen entwickelt werden, die sich auf die jeweiligen Verfahren konkretisieren lassen. Der Vortrag gibt hierzu erste Einblicke in die Arbeit des Ausschusses.
The field of non-destructive testing of civil structures (NDT-CE) has been continuously growing. Due to the complexity and diversity of civil constructions as well as the heterogeneity of concrete, specific standards or guidelines for the application of modern NDT-CE are still missing. The development of individual solutions is the current approach, which is just as challenging as it is common for NDT-CE.
With the increasing development and commercialization of NDT-CE technology, the group of practitioners is growing. To ensure a good level of quality in the industry, it appears necessary to establish adequate means.
Naturally, the performance of NDT-CE methods regarding a specific application is strongly dependent on choosing the most suitable inspection technique and applying it correctly, generally referred to as the inspection procedure in the field of NDT. There are well-defined guidelines regarding procedure documentation and handling in many fields of NDT (e.g. nuclear, aerospace or automotive) according to the high importance of procedures in assuring a successful and reliable application. For a long time, this has not always been the case with NDT-CE, which is still considered a unique discipline of NDT. Part of the reason for that might be the young development state of NDTCE, the heterogeneity of building materials like concrete, timber or masonry as a material and the diversity of civil structures. In consequence, NDT-CE procedure development is considered challenging.
Among other aspects, addressed in the subcommittee on Quality Assurance (UA-QS) within the committee for NDT-CE of the German Society for Nondestructive Testing (DGZfP), part of its work aims at establishing an adequate basis for NDT-CE procedure development. While some of the highly developed approaches from other industries are taken into consideration, they need to be analyzed regarding their suitability for NDT-CE and adapted accordingly. For a procedure to be as defined as possible, it needs to contain sufficient information, such as the scope and limitations regarding material, geometry and condition of the test object, inspection parameters, calibration, data acquisition, analysis criteria as well as requirements regarding the inspection personnel.
For a successful implementation in the field, it is important to define the specific procedure as precisely as possible. Despite the necessity of a great amount of information to be included, the procedure needs to be suitable for efficient field application.
The UA-QS is developing a guideline for NDT-CE procedures suitable for application in this field of NDT to ensure correct and reproducible application. To demonstrate and evaluate this concept, specific examples of procedures are also produced. In particular, the UA-QS has developed a procedure for the detection and positioning of tendon ducts using Ground Penetrating Radar (GPR). This procedure is tested regarding the practical applicability in a roundrobin on a defined type of reference test block.