8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen
Filtern
Erscheinungsjahr
- 2019 (50) (entfernen)
Dokumenttyp
- Vortrag (21)
- Beitrag zu einem Tagungsband (16)
- Zeitschriftenartikel (6)
- Posterpräsentation (5)
- Beitrag zu einem Sammelband (2)
Sprache
- Englisch (50) (entfernen)
Schlagworte
- Concrete (16)
- Monitoring (10)
- NDT (9)
- Ultrasound (8)
- LIBS (7)
- Chloride (5)
- Air-coupled ultrasound (4)
- Defect detection (4)
- Embedded sensors (4)
- Mapping (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (50) (entfernen)
Eingeladener Vortrag
- nein (21)
The analysis of the chemical composition of cement-based materials like concrete is a crucial task in civil engineering. Concrete is a multi-phase material made of cement, water, aggregates, additives and admixtures. During the damage assessment of concrete structures, the external ingress of harmful species like chlorine, alkalis or sulfates needs to be determined. In order to provide a fast and precise analysis of concrete the application of LIBS offers unique possibilities as the technique can detect all elements at air atmosphere.
To determine the condition of concrete, the information about the chemical composition, the ingress of harmful species as well as the evaluation of characteristic values like the used cement type or the type of aggregates are needed. This work presents the two-dimensional evaluation of concrete samples using LIBS and multivariate data analysis of atomic and molecular emission. For the evaluation of the main components different classification methods will be applied to identify the heterogeneity of the samples. With respect to their specific phase, different species will be quantified using multivariate regression (PLS) and important figures of merit will be presented. All results will be verified using Standard procedure of wet chemistry (XRF, potentiometric titration and ICP-OES).
The application of a LIBS system is presented. A diode-pumped low energy laser (3 mJ, 1.5 ns, 100 Hz) and a compact NIR spectrometer are used. A scanner allows the two-dimensional element mapping. For the quantitative analysis calibration of the system is carried out with reference samples in a concentration range of chlorine of 0.05 wt.% to 2.5 wt.%. To determine the 2D distribution of harmful elements (Cl, C), concrete cores were drilled, split and analyzed directly. By comparing the chloride ingress and the carbonation, the interaction of both processes can be visualized in one measurement that takes less than 10 minutes with a drill core of 50 mm x 100 mm. Results obtained were compared and verified with standard measurements.
Due to the penetration of harmful chlorides into concrete, e.g. from de-icing salt, damage processes such as chloride-related pitting corrosion can occur if critical values are exceeded. In this study, multiphase materials such as chloride-contaminated concrete are examined in detail. A direct comparison is made by analyzing the spectroscopic information of simultaneously measured atomic and molecular emissions with laser-induced breakdown spectroscopy (LIBS). In addition, the influence on the calibration is examined on the basis of the combined spectral information of both reaction paths of the penetrated chlorides. The calibration models of univariate and multivariate methods were validated using reference samples with wet chemical analysis. The results are applied to a concrete sample of a parking deck, which was also analyzed by potentiometric wet chemistry. In order to account for the heterogeneity of concrete, spatially (200 μm) and spectroscopically (0.1 nm) resolved LIBS measurements were performed using a fully automated laboratory system. Simultaneous measurements with three spectrometers allow the analysis of the emission processes of several elements such as Cl, Ca, O, Si and Mg as well as the newly formed molecules CaO and CaCl. The evaluation of the molecular emission in combination with atomic lines extends the analytical performance, since different concrete phases such as aggregates and cement matrix can be better represented. The measurements were carried out in ambient air and with helium purge gas. The limit of detection (LOD) achieved for a combined evaluation of atomic and molecular emission was determined to be 0.028 wt%.
NDE of foundations
(2019)
This talk teaches the basic princioles and applications of NDT methods for deep foundations, sprecifically piles. A variety of testing methods are discussed (integrity testing, ultrasonic crosshole logging, parallel seismic and others). Capabilities and limitations are given as well as specific hints for practical use.