8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen
Filtern
Dokumenttyp
- Vortrag (181)
- Zeitschriftenartikel (107)
- Beitrag zu einem Tagungsband (80)
- Posterpräsentation (62)
- Sonstiges (9)
- Buchkapitel (8)
- Forschungsdatensatz (8)
- Beitrag zu einem Sammelband (3)
- Forschungsbericht (3)
- Dissertation (2)
Sprache
- Englisch (342)
- Deutsch (121)
- Mehrsprachig (1)
Schlagworte
- Concrete (99)
- Ultrasound (86)
- LIBS (62)
- Monitoring (53)
- Non-destructive testing (37)
- Beton (28)
- Ultraschall (28)
- Zerstörungsfreie Prüfung (27)
- NDT (26)
- Coda wave interferometry (21)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (464)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (464)
- 7 Bauwerkssicherheit (37)
- 8.0 Abteilungsleitung und andere (30)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (20)
- 8.6 Faseroptische Sensorik (16)
- 7.4 Baustofftechnologie (15)
- 1 Analytische Chemie; Referenzmaterialien (10)
- 8.5 Röntgenbildgebung (10)
- 7.1 Baustoffe (9)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (181)
This technical note highlights the fact that CF-LIBS algorithms work in mole fractions, while results of spectrochemical analysis are usually reported in mass fractions or mass percent. Ignoring this difference and not converting mole fractions to mass fractions can lead to errors in reported concentrations determined by the CF-LIBS method and inadequate comparison of these concentrations with certified concentrations. Here, the key points of the CF-LIBS algorithm are reproduced and the formulae for converting a mole fraction to a mass fraction and vice versa are given. Several numerical examples are also given, which show that the greater the difference between the molar mass of an individual element in a sample and the average molar mass, the greater the discrepancy between the mole and mass fractions.
Additive manufacturing of concrete structures is a novel and emerging technology. Freecontouring in civil engineering, which allows for entirely new designs, is a significant advantage. Inthe future, lower construction costs are expected with increased construction speeds and decreasingrequired materials and workers. However, architects and civil engineers rely on a certain quality ofexecution to fulfil construction standards. Although several techniques and approaches demonstratethe advantages, quality control during printing is highly challenging and rarely applied. Due to thecontinuous mixing process commonly used in 3D concrete printing, it is impossible to exclude varia-tions in the dry mixture or water content, and a test sample cannot be taken as a representative samplefor the whole structure. Although mortar properties vary only locally, a defect in one layer duringprinting could affect the entire integrity of the whole structure . Therefore, real-time process monitor-ing is required to record and document the printing process.At the Bundesanstalt für Materialforschung und -prüfung (BAM) a new test rig for the additive man-ufacturing of concrete is built. The primary purpose is measuring and monitoring the properties of amortar during the printing process.The following study investigates an approach for calculating yield stress and plastic viscosity based onexperimentally recorded pressure data. The calculations assume that fresh mortar behaves as a Bing-ham fluid and that the Buckingham-Reiner-equation is applicable. A test setup consisting of rigid pipeswith integrated pressure sensors at different positions is utilized.Monitoring the printing process with different sensors is crucial for the quality control of an ongoingprocess.
Bei der Betonage von Abdichtbauwerken können Temperaturen bis 110 °C und hohe Drücke bis 5 MPa erreicht werden. Mittels Technikumsversuchen wurde nachgewiesen, dass Mikroakustik- und Ultraschallsensoren zum Einbau in Demonstrationsbauwerke geeignet sind.
Die Untersuchungen wurden bei der BAM (Bundesanstalt für Materialforschung und -prüfung) in Berlin durchgeführt. Es ist vorgesehen, die Sensoren in Morsleben am Demonstrationsbauwerk im Anhydrit einzusetzen.
Ultrasonic echo testing is a well-established non-destructive testing technique used to investigate the interior of concrete structures in civil engineering. For the reconstruction of internal features, methods similar to seismic imaging are applied. To improve the ultrasonic imaging capabilities, we investigate the potential of a newly available 3D matrix mode measurement device in combination with advanced imaging techniques.
Commonly used ultrasonic array measurement devices rely on several ultrasonic transducers coupled to act as one transducer that transmits or receives transversal ultrasound waves. Although this approach is well suited to detect elongated structures such as pipes and rebars, it has limitations if 3D embedded objects are present. Hence, the ultrasonic device MiraA1040Pro used here is designed to measure the ultrasonic wavefield on a 4 by 16 matrix of individual transducers. For testing, we used laboratory specimens with linear and spheric embedded structures first. Both linear and matrix mode measurements were conducted and analysed using the Synthetic Aperture Focusing Technique
(SAFT) which is similar to Kirchhoff migration. Second, we used a data set from Teutschenthal mine at a shotcrete specimen constructed to simulate engineered barriers tailored for nuclear waste repositories. Ultrasonic measurements were investigated as a tool for quality assurance of these structures. The specimen contains both artificial 3D artifacts as well as naturally occurring defects such as a delamination. To make use of the advanced data acquisition, focusing 3D imaging techniques are applied to further improve the imaging quality.
Generally, the reconstructed images from the 3D matrix mode data have a lower level of Signal-to-Noise-Ratio than the 2D linear mode because the source signal is weaker compared to the linear mode. Moreover, complex wave conversions of the SH-transversal wave occur that are reduced in the 2D linear scenario. However, clearer images can be achieved at non-linear features, particularly with focusing imaging methods. Thus, combining 3D data acquisition techniques with advanced imaging methods improves the success in imaging complex concrete structures. This is of particular interest for thick concrete structures in nuclear barrier systems or foundations. Additionally, we demonstrate opportunities to use well-constrained test laboratory scenarios from non-destructive testing as a practical test case for geophysical methods.
Machbarkeitsstudie zur Zustandserfassung von Spannbetonschwellen mit dem Ultraschallverfahren
(2024)
Das niederfrequente Ultraschallverfahren zur zerstörungsfreien Zustandserfassung von Stahlbetonkomponenten findet im Bauwesen umfangreiche Anwendung. Multistatische Arrays sind am Markt verfügbar und ausgelegt für die Prüfung großflächiger Betonstrukturen. In einer Machbarkeitsstudie wird überprüft, ob eine Zustandserfassung an schlanken Spannbetonschwellen möglich ist. B70-Schwellen und B90-Weichenschwellen wurden hierfür im Labor, im Schienennetz und während der Wiederaufbereitung mit dem Ultraschallverfahren untersucht. Fokus ist die Detektion von Sickenrisse, Kopfrissen und Treibrissen im Bereich des Schwellenkopfes.
Die rekonstruierten Ultraschalldaten zeigen für intakt-klassifizierte Schwellen ein reproduzierbares Rückwandecho und weitere Reflexionen an den Schwellenaußenkanten. Die Ausprägung der Amplitude variiert je nach Degradation durch Belastung und Verwitterung. Defekt-klassifizierte Schwellen mit z. B. Kopfrissen oder unterseitigen Abplatzungen unterscheiden sich im Signalbild deutlich durch oberflächennahe Reflexionen bzw. verschobene Rückwandechos. Basierend auf den untersuchten Schwellen zeigt die Machbarkeitsstudie, dass eine zerstörungsfreie Zustandserfassung mit Hilfe des Ultraschallverfahrens grundsätzlich möglich ist.
Entwicklung einer flexiblen Datenablage zur sicheren Speicherung von Bauwerksdaten - "CASPAR"
(2024)
Bestandsunterlagen von älteren Bauwerken sind bezüglich einer rechnerischen Zustandsbewertung häufig nur in einem unzureichenden Umfang verfügbar. Dies gilt sowohl für den privaten als auch für den öffentlichen Bereich. Der Wert von Bestandsunterlagen für Gebäude oder Brücken ist Vielen nicht bekannt. Soll jedoch der aktuelle Zustand von Bauwerken bewertet, sollen Restlebensdauern abgeschätzt oder soll umgebaut werden, stellen Bestandsunterlagen die Grundlage dafür dar. Liegen diese nicht vor, so muss die Bauweise des Bauwerkes kostenintensiv nachvollzogen und mit nachträglichen Untersuchungsverfahren bewertet werden. Vor allem ist dies darauf zurückzuführen, dass die Aufbewahrung der Bestandsunterlagen dem Bauherrn obliegt und diese meist in Papierform vorliegen und dann bei Umzügen, Betriebsschließungen, Eigentümerwechsel etc. verloren gehen.
Die Digitalisierung im Bauwesen bietet hier Möglichkeiten diese Probleme künftig zu vermeiden. Bereits heute nimmt die digitale Planung im Bauwesen eine immer größere Rolle ein. Mehr und mehr Bauvorhaben werden schon jetzt in sogenannten BIM Modellen (Building Information Modelling) geplant. Um die Akzeptanz einer digitalen Lösung zu gewährleisten muss die Vertrauenswürdigkeit von Daten auch langfristig garantiert sein. Naturgemäß unterliegen Erkenntnisse, die aus Daten gewonnen werden, häufig vielen Prozessschritten mit unterschiedlichen Beteiligten. Es lässt sich vor dem Hintergrund der üblichen Lebensdauern von Bauwerken leicht erkennen, dass es schwierig ist diese Prozesskette, von der Datenerhebung bis zur teilweise jahrzehnte späteren Nutzung, beweissicher und rückführbar zu gestalten. Diese Attribute sind es aber, die die Vertrauensbasis für die Qualität und somit auch die Akzeptanz von digitalisierten Daten bilden. Im Projekt „CASPAR“ erarbeiten wir eine mögliche technologische Grundlage, um Bauwerksdaten langfristig und manipulationssicher zu speichern.
Relevant, abgesichert, vergleichbar – ZfP-Ergebnisse bei der Zuverlässigkeitsbewertung von Bauwerken
(2024)
Die Nachrechnung, d. h. die Zuverlässigkeitsbewertung von bestehenden Brücken, ist aufgrund der alternden Infrastruktur und sich verändernden Anforderungen an die Bauwerke eine fortwährend große Herausforderung in Wissenschaft, Praxis und Standardisierung. Ein wesentlicher Vorteil bei der Nachrechnung besteht gegenüber dem Neubauentwurf in der Möglichkeit, Informationen über den tatsächlichen Zustand der Bauwerke zu erheben – im Idealfall ohne wesentliche destruktive Eingriffe in die Bausubstanz. Deren Verwendung bei der Zuverlässigkeitsanalyse dient der Zuschärfung von Berechnungsmodellen und ermöglicht realitätsnähere Bauwerksbeurteilungen. Die Einbeziehung von Messdaten bei der Zuverlässigkeitsbewertung setzt jedoch voraus, dass die Qualität der gemessenen Informationen bekannt und deren Vergleichbarkeit sichergestellt ist. Darüber hinaus sollte die Relevanz der messbaren Informationen beziffert werden, um wirtschaftliche Inspektionen am Bauwerk gezielt durchführen zu können.
In diesem Beitrag wird am Beispiel von Ultraschall- und Radarmessungen an einer Spannbetonbrücke gezeigt, wie ZfP-Ergebnisse bei der Zuverlässigkeitsbewertung von Bestandsbauwerken mit probabilistischen Methoden genutzt werden können. Betrachtet werden innere geometrische Abmessungen wie die Lage der Bewehrung oder von Spanngliedern. Die Relevanz der messbaren Informationen wird anhand von Sensitivitätsanalysen beziffert. Messunsicherheitsbetrachtungen dienen der Bezifferung der Qualität der gemessenen Informationen und der Gewährleistung deren Vergleichbarkeit. Abschließend werden die möglichen Auswirkungen der Berücksichtigung von ZfP-Ergebnissen auf die Bauwerkszuverlässigkeit in einem Nachweis einer Spannbetonbrücke gemäß Eurocode demonstriert.
Der Vortrag behandelt den Stand der Technik bei der zerstörungsfreien Prüfung von Betonkonstruktionen und insbesondere den Stand und die Herausforderungen bei der Digitalisierung. Es werden Prüfaufgaben sowie etablierte Prüfmethoden und die passende Auswahl diskutiert. Ein weitere Schwerpunkt liegt bei der Genauigkeit und Verlässlichkeit und dem Konzept ZfPStatik. Abschließend werden Schnittstellen zu BIM, SIB-Bauwerke und anderen System kurz angerissen und ein Katalog offener Fragen aufgestellt.
Locating and sizing delaminations is a common inspection task in the maintenance and quality control of construction and rehabilitation. Their detection is an important area of application of nondestructive testing in civil engineering (NDT-CE). To improve this application, NDT test systems and test solutions must be compared, for which specimens containing well-defined delaminations are needed to serve as a reference. Currently, there are no widely accepted procedures available for creating such flaws locally and reproducibly. This study presents procedures for creating artificial delaminations repeatably and as close as possible to natural delaminations. To produce the discontinuities only substances were used which can occur in concrete components and do not affect the application of NDT-CE methods. Ultrasonic pulse-echo (UPE) was used to test the flaws in the specimens. The delaminations were created by applying expansive mortar in prepared through holes. Three specimens with two delaminations each were built and tested using UPE.
AbstractAir‐coupled ultrasonic testing (ACU) is a pioneering technique in non‐destructive testing (NDT). While contact testing and fluid immersion testing are standard methods in many applications, the adoption of ACU is progressing slowly, especially in the low ultrasonic frequency range. A main reason for this development is the difficulty of generating high amplitude ultrasonic bursts with equipment that is robust enough to be applied outside a laboratory environment. This paper presents the fluidic ultrasonic transducer as a solution to this challenge. This novel aeroacoustic source uses the flow instability of a sonic jet in a bistable fluidic switch to generate ultrasonic bursts up to 60 kHz with a mean peak pressure of 320 Pa. The robust design allows operation in adverse environments, independent of the operating fluid. Non‐contact through‐transmission experiments are conducted on four materials and compared with the results of conventional transducers. For the first time, it is shown that the novel fluidic ultrasonic transducer provides a suitable acoustic signal for NDT tasks and has potential of furthering the implementation of ACU in industrial applications.This article is protected by copyright. All rights reserved
In ultrasonic testing, material and structural properties of a specimen can be derived from the time-of-flight (ToF). Using signal features, such as the first peak or envelope maximum, to calculate the ToF is error-prone in multipath arrangements or dispersive and attenuating materials, which is not the case for the signal onset. Borrowing from seismology, researchers used the Akaike information criterion (AIC) picker to automatically determine onset times. The most commonly used formulation, Maeda's AIC picker, is reassessed and found to be based on inappropriate assumptions for signals often used in ultrasonic testing and dependent on arbitrary parameters. Consequently, an onset picker for ultrasonic through-transmission measurements is proposed, based on a spectral entropy criterion (SEC) to model the signal using the AIC framework. This SEC picker takes into account the spectral properties of the ultrasonic signal and is virtually free of arbitrary parameters. Synthetic and experimental data are used to compare the performance of SEC and AIC pickers. It is shown that the accuracy of onset picking is improved for densely sampled data.
Chapter 6: Case studies
(2023)
Until the 1980s radiography was used to inspect civil structures in case of special demands and showed a much better resolution than other NDT techniques. However, due to safety concerns and cost issues, this method is almost never used anymore. Meanwhile, non-destructive techniques such as ultrasound or
radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features when applied to reinforced or prestressed concrete inspection.
Muon tomography has received much attention recently. Muons are particles generated naturally by cosmic rays in the upper atmosphere and pose no risk to humans. Novel detectors and tomographic imaging algorithms have opened new fields of application, mainly in the nuclear sector, but also in spectacular cases such as the Egyptian pyramids.
As a first step towards practical application in civil engineering and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results have been at least of similar quality compared to ultrasonic and radar imaging, potentially even better. Recently, the research was expanded to more realistic testing problems such as the detection of voids in certain structural elements. However, before practical implementation, more robust, mobile, and affordable detectors would be required as well as user-Friendly imaging and simulation software.
The built infrastructure ages and requires regular inspection and, when in doubt, monitoring. To ensure that older concrete bridges showing signs of deterioration can be used safely, several innovative monitoring tools have been introduced, including but not limited to optical, fiber-optic, or acoustic emission techniques. However, there are gaps in the portfolio. A sensing technique that covers a wide range of damage scenarios and larger volumes, while still being sensitive and specific, would be beneficial.
For about 15 years, research has been conducted on ultrasonic monitoring of concrete structures that goes beyond the traditional ultrasonic pulse velocity test (PV test), mostly using a very sensitive data evaluation technique called coda wave interferometry. At BAM we have developed sensors and instrumentation specifically for this method.
We have instrumented a 70-year-old, severely damaged prestressed concrete bridge in Germany in addition to a commercial monitoring system. We have now collected data for almost 3 years. We can show that we can provide information about the stress distribution in the bridge. We have also been able to confirm that there has been no significant additional damage to the bridge since the installation.
X-rays without X-rays: Can muon tomography provide pictures from within concrete and other objects?
(2024)
Until the 1980s radiography was used to inspect civil structures in case of special demands and showed a much better resolution than other NDT techniques. However, due to safety concerns and cost issues, this method is almost never used anymore. Meanwhile, non-destructive techniques such as ultrasound or
radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features when applied to reinforced or prestressed concrete inspection.
Muon tomography has received much attention recently. Muons are particles generated naturally by cosmic rays in the upper atmosphere and pose no risk to humans. Novel detectors and tomographic imaging algorithms have opened new fields of application, mainly in the nuclear sector, but also in spectacular cases such as the Egyptian pyramids.
As a first step towards practical application in civil engineering and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results have been at least of similar quality compared to ultrasonic and radar imaging, potentially even better. Recently, the research was expanded to more realistic testing problems such as the detection of voids in certain structural elements. However, before practical implementation, more robust, mobile, and affordable detectors would be required as well as user-Friendly imaging and simulation software.
The talk also discusses other applications , such as volcanology, mining and geothermal exploration.
The Large Aperture Ultrasound System (LAUS) developed at BAM is known for its ability to penetrate thick objects, especially concrete structures commonly used in nuclear waste storage and other applications in civil engineering. Although the current system effectively penetrates up to ~9 m, further optimization is imperative to enhance the safety and integrity of disposal structures for radioactive or toxic waste. This study focuses on enhancing the system’s efficiency by optimizing the transducer spacing, ensuring that resolution is not compromised. An array of twelve horizontal shear wave transducers was used to find a balance between penetration depth and resolution. Systematic adjustments of the spacing between transmitter and receiver units were undertaken based on target depth ranges of known reflectors at depth ranges from 5 m to 10 m. The trade-offs between resolution and artifact generation were meticulously assessed. This comprehensive study employs a dual approach using both simulations and measurements to investigate the performance of transducer units spaced at 10 cm, 20 cm, 30 cm, and 40 cm. We found that for depths up to 5 m, a spacing of 10 cm for LAUS transducer units provided the best resolution as confirmed by both simulations and measurements. This optimal distance is particularly effective in achieving clear reflections and a satisfactory signal-to-noise ratio (SNR) in imaging scenarios with materials such as thick concrete structures. However, when targeting depths greater than 10 m, we recommend increasing the distance between the transducers to 20 cm. This increased spacing improves the SNR in comparison to other spacings, as seen in the simulation of a 10 m deep backwall. Our results emphasize the critical role of transducer spacing in achieving the desired SNR and resolution, especially in the context of depth imaging requirements for LAUS applications. In addition to the transducer spacing, different distances between individual sets of measurement positions were tested. Overall, keeping the minimal possible distance between measurement position offsets provides the best imaging results at greater depths. The proposed optimizations for the LAUS in this study are primarily relevant to applications on massive nuclear structures for nuclear waste management. This research highlights the need for better LAUS efficiency in applications such as sealing structures, laying the foundation for future technological advances in this field.
The ultrasonic echo technique is widely used in non-destructive testing (NDT) of concrete objects for thickness measurements, geometry determinations and localization of built-in components. To improve ultrasonic imaging of complex concrete structures, we transferred a seismic imaging technique, the Reverse Time Migration (RTM), to NDT in civil engineering. RTM, in contrast to the conventionally used synthetic aperture focusing technique (SAFT) algorithms, considers all wavefield types and thus, can handle complex wave propagations in any direction with no limit on velocity variations and reflector dip. In this paper, we focused on the development, application and evaluation of a two-dimensional elastic RTM algorithm considering horizontally polarized shear (SH) waves only. We applied the elastic SH RTM routine to synthetic ultrasonic echo SH-wave data generated with a concrete model incorporating several steps and circular cavities. As these features can often be found in real-world NDT use cases, their imaging is extremely important. By using elastic SH RTM, we were able to clearly reproduce almost all reflectors inside the concrete model including the vertical step edges and the cross sections of the cavities.We were also capable to show that more features could be mapped compared to SAFT, and that imaging of complex reflectors could be sharpened compared to elastic P-SV (compressional-vertically polarized shear) RTM. Our promising results illustrate that elastic SH RTM has the potential to significantly enhance the reconstruction of challenging concrete structures, representing an important step forward for precise, high-quality ultrasonic NDT in civil engineering.
The through-life management of our constantly ageing infrastructure is a basic requirement in order to ensure their structural safety and serviceability. Each structure experiences deterioration processes with time leading to a decrease of structural safety and serviceability. The design of new structures considers the expected deterioration for a defined period, the design service life. However, a frequent survey of structural safety controlling structural condition should be mandatory and a maintenance plan should be an integral part of the design. In addition, many structures have exceeded their design service life already or are very close to it leading to an increasing demand for condition assessment. On the one hand, assumptions made during design are not valid any more due to change of the loads, e.g., increasing traffic loads in terms of number and weights. On the other hand, design codes evolved over time in such a way that existing structures do not comply with today’s standards. In all these cases, the through-life management is an important tool to maintain the accessibility of existing structures with known reliability.
In line with the new Model Code for Concrete Structures, which includes guidance for both – design of new structures and assessment of existing structures, the Task Group 3.3 focused on the compilation of a state-of-the-art guideline for the through-life management of existing concrete structures, including:
Data acquisition by testing and monitoring techniques;
Condition assessment for the evaluation of existing structures;
Performance prediction using advanced methods;
Decision-making procedures to perform a complete assessment of existing structure.
The overall objective of the through-life management is the assessment of the current condition and the estimation of the remaining service life under consideration of all boundary conditions.
A safety or security related assessment of explosions, accidental and intentional scenarios alike, often necessitate performance of replication-tests. Such test results are necessary to clarify the causes within the scope of forensic investigations. To gain important insights into the behavior of structures and materials under such loading, field tests may also be performed in accordance with different test standards. To determine the resistance of building-structures after explosions, estimation of the residual load-bearing capacity in addition to the assessment of dynamic structural response and damage to the building components is important. In most cases an evaluation of structural integrity is based only on the visual damage, resulting in an overestimation of the residual capacity.
The Bundesanstalt für Materialforschung und -prüfung (BAM) operates the Test site for Technical Safety (TTS) on an area measuring about 12 km2 in the Federal State of Brandenburg for execution of true-to-scale explosion tests. At the TTS, building component testing was performed to assess the suitability of different non-destructive testing methods to characterize the dynamic structural response and damage resulting from the detonation of high explosives.
Different blast-loading scenarios were realized by varying the net explosive mass and the standoff distance with all scenarios representing a near-field detonation. The test object was a reinforced concrete wall 2 m high, 2.5 m wide and 20 cm thick, fixed at both vertical edges. The dynamic loading of the wall was characterized with 8 piezoelectric pressure sensors flush-mounted on the front surface, thus measuring the reflected pressures from the shock wave. The tests were conducted with the aim of characterizing the global behavior of the wall under dynamic shock loading and the resulting local damage pattern, respectively. High speed digital image correlation was implemented in combination with multiple acceleration sensors to observe the rear surface of the wall to chart the dynamic deflection during the loading and to determine the residual deformation after the loading had ceased. In addition, one test specimen was instrumented with fiber optic sensor cables, both fixed to the rebars and embedded in the concrete-matrix, respectively. Firstly, these sensors were interrogated during the blast test by a distributed acoustic sensing (DAS) device using a particularly high sampling rate to measure the shock-induced vibrations in the structure with high temporal resolution. This delivers information on dynamics of compression and tension cycles from within the structure. Secondly, the local damage-pattern emerging during the series of blasts was determined via distributed fiber optic strain sensing (DSS) by interrogating the embedded fiber optic sensors with a high spatial resolution DSS device after each blast. This enabled the characterization of non-visual damage to the structure, in particular with regard to the formation of localized cracks in the concrete matrix. The DSS was further complimented by a structure-scanner based on ultrasonic measurements.
Our contribution describes this new test approach in detail. Results of the three datasets, namely dynamic shock loading, global behavior of the test object and the local damage pattern will be presented. The suitability of the implemented measurement methods will be discussed in combination with the challenges in their application for technical safety evaluation of building components under explosive loading.
BAM (Federal Institute for Materials Research and Testing) is developing an electronic measurement system to be placed inside a waste drum, which will be filled with concrete. The goal of this measurement system is to monitor the process of hardening and the evolution of the concrete itself over time to indirectly identify potential defects such as corrosion or cracking. The measured parameters are humidity, temperature, and pressure. In this regard, particular attention was given to the design of the electronic board’s enclosure, to allow the sensors to measure the state of the concrete without being in direct contact with it. In the scope of the European Commission’s project of PREDIS, the supply of power to the battery-less sensors and the data acquired by such sensors are transmitted through the metallic waste drum by an innovative wireless technology developed by VTT (Technical Research Centre of Finland) in order to ensure long-term operation while keeping the integrity of the sealed container.
BAM is developing an electronic measurement system to be placed inside a waste drum, which will be filled with concrete. The goal of this measurement system is to monitor the process of hardening and the evolution of the concrete itself over time to indirectly identify potential defects such as corrosion or cracking. The measured parameters are humidity, temperature, and pressure. In this regard, particular attention was given to the design of the electronic board’s enclosure, to allow the sensors to measure the state of the concrete without being in direct contact with it. In the scope of the EU project PREDIS, the data acquired by such sensors are transmitted from inside to outside the metallic waste drum through wireless technology.
The sensing system is made of a chain of small sensing units, called SensorNodes. Each SensorNode includes two off-the-shelf sensors, one for relative humidity and temperature and one for pressure and temperature. A SensorNode is designed to have a unique identifier, in order to be connected to other units while being uniquely discoverable by a standard communication protocol. In this way, a distributed matrix of measurement points is created.
One of the most challenging tasks in designing a measurement system to run in a harsh environment (such as hardening concrete) is to let the sensors sense the external environment without damaging the sensor itself.
To keep the external environment away from the electronic board while still letting the sensors measure the concrete behavior, holes have been drilled through the lid and covered from the inside with a layer of a porous membrane. The membrane's pores allow water and gas particles to pass through and let the enclosed air equilibrate with the external environment.
With the help of the developed sensors, monitoring concrete in cemented waste drums will be possible. The derived data will also serve as the basis for ongoing modeling approaches for digital twins within the Predis project. Overall, the sensors provide a means of enabling safe nuclear waste management through advanced monitoring
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
Engineering barrier systems are a crucial part of the safe underground disposal of radioactive waste, particularly in salt as a host rock. Sealing structures made of tailored concrete are under test at various sites in Germany. To characterise the material properties of the concrete and potentially also the bonding to the host rock as part of the necessary subsurface structures, we apply non-destructive testing making use of advanced geophysical imaging methods.
Ultrasonic investigations have been carried out at underground concrete structures in the Teutschenthal mine in Germany. Here, we show results from two distinct constructions produced in a shotcrete procedure. Our goal is to analyse the performance of ultrasonics to be used as quality assurance for sealing structures made from shotcrete. First, a ~10 m long shotcrete structure is investigated with the help of a unique Large Aperture Ultrasonic System (LAUS) allowing for depth penetration of > 9 m. We perform measurements at the front and from the side of the construction. Second, we obtain results from a 1 m thick shotcrete body containing several artificial defects (width up to 8 cm). Ultrasonic testing data were acquired using a commercial multi-static device. Additionally, a new device measuring with 3D mode instead of line mode is applied and preliminary results will be shown.
Generally, the acquired ultrasonic data are analysed by the Synthetic Aperture Focusing Technique that is commonly applied in non-destructive testing. As a result, reflectors in the analysed shotcrete structures are imaged. Individual reflections from internal features and particularly the opposite wall are identified. An unexpected delamination wider than 30 cm is clearly imaged and later verified by boreholes. Thus, the method is – in general – suitable to serve as a quality measure. However, particularly the small and deep artificial defects can hardly be identified in the resulting images. Thus, we use advanced geophysical imaging methods to further enhance the quality of the obtained images. The recorded ultrasonic energy is focused to the physically reflective origin in the analysed volume. First results clearly show that we successfully improve the image quality regarding noise level and artifacts and hence facilitate the detection of objects.
In total, we present a valuable experiment under realistic conditions for underground sealing structures made from shotcrete, where the locations of artificial reflectors are partly known. This experiment serves as a unique basis to analyse the performance of advanced analysis methods to obtain high-quality images of the structure’s interior. Hence, the developed ultrasonic testing and analysis schemes can serve as a part of quality assurance that will help to enable safe sealing structures for nuclear waste disposal.
Information about an existing structure can be collected at certain costs to evaluate the reliability and condition as realistically as necessary. This information can be relevant or irrelevant, true or biased, precise or imprecise. The incorporation of relevant and quality-assessed measured information into reliability reassessment offers the chance to extend remaining lifetimes and support decision making about optimal actions or maintenance strategies. This paper shows recent developments in a national research project that aims to produce a guideline on the NDT-based, structure-specific modification of partial safety factors. The general methodology, results from recalculations according to the Eurocodes and metrologically solvable testing tasks relevant in the recalculation of the concrete bridges are shown and compared with the non-destructive testing methods applicable to concrete bridges. A case study is used to demonstrate that as-built drawings, in this case of the positions of tendons and shear reinforcement, can be verified using the radar method.
The evaluation of technical components and materials in terms of condition and quality with the aid of non-destructive testing methods plays an outstanding role both in industrial serial production and in the individual assessment of components. The ultrasonic echo method is used for a wide variety of testing tasks, such as measuring the thickness of a component. At the Bundesanstalt für Materialforschung und -prüfung (BAM) in Berlin, test methods are developed and their performance is demonstrated. For this purpose, references such as materials, test procedures or data sets are generated, which are used to evaluate these developed test methods. An important component of these references are data sets that are created according to the BAM Data Policy and made available to the scientific community and users of test methods in practice on the basis of the FAIR principles (Findability, Accessibility, Interoperability, and Reuse).
Im DIN-Normenausschuss Materialprüfung (NMP) wurde das Normungsgremium NA 062-08-28 AA „Qualifizierung von zerstörungsfreien Prüfungen“ reaktiviert. Das Ziel der Reaktivierung ist die Erarbeitung einer Norm für einen standardisierten Prozess zur probabilistischen Bewertung von Prüfverfahren.
In der zerstörungsfreien Prüfung (ZfP) führt die Ermittlung von Mess- / Prüfunsicherheiten von Prüfverfahren, in normativer Hinsicht in Deutschland und Europa, noch ein Schattendasein. Die Norm ISO IEC 17025 und auch der VDA-Band 5 wurden weiter in Richtung Messunsicherheit entwickelt, allerdings führt ihre Anwendung in der ZfP zu Problemen.
Der Arbeitsausschuss NA 062-08-28 AA soll hier den Brückenschlag zwischen Messunsicherheit, objektiver statistischer Bewertung für ZfP-Verfahren und eine weitere Stärkung der probabilistischen Bruchmechanik erreichen. Geplant ist daher die Erarbeitung einer DIN-Norm, welche die Kriterien für eine korrekte Versuchsplanung, ein praktikables Vorgehen zur Bewertung der Prüfergebnisse und die mathematische Überführung in eine Zuverlässigkeitsaussage enthält. Es soll ein Leitfaden erstellt werden, der für ein möglichst breites Branchenspektrum eingesetzt werden kann, unabhängig von den Besonderheiten verschiedener Industriezweige.
Dargestellt werden das relevante Normungsgremium sowie der Hintergrund des zu erstellenden Dokuments.
Almost all building materials in civil engineering have an open porosity and interact with or are affected by the environmental conditions. Structures might suffer from effects such as moisture adsorption, carbonation, corrosion, penetration of salt ions and chemical substances, etc. In the hygroscopic range, these processes are mostly driven by diffusion. Due to the confinement of small pores (less than1 µm), the Knudsen effect reduces the molecular diffusion. This reduction can become more significant in case of temporal changing pore systems because of physisorption of water vapor, carbonation, or chemisorption.
In this study, unstabilised earth blocks and earth masonry are investigated. In a first step, the pore size distribution of the blocks is measured and sorption isotherms are recorded in experiments. Besides the ordinary physisorption, the involved clay minerals undergo swelling or shrinking due to chemisorption. The following two effects must be considered: first, the reduction of the available pore space by the adsorbed water layer. For this, the Hillerborg sorption theory is used, which is a combination of the well-known Brunauer-Emmett-Teller sorption theory and the Kelvin equation. This allows the computation of adsorbed water layers even in curved pore geometries. Second, the variation of the initial pore size distribution due to chemisorption needs to be modelled. Based on these two models, the effective diffusion coefficient can be predicted. For validation, arrays of relative humidity sensors were embedded into a free-standing earth masonry wall. This monitoring was carried out over more than a year to have a broad variety of environmental conditions and was located in Berlin, Germany.
The prediction of the effective diffusion coefficient can also be transferred to other processes and allows the investigation of materials having temporarily changing pore systems. Examples are the carbonation of cementitious materials, alkali silica reaction, calcium leaching of long-lasting structures, etc. These effects are prominent in the meso-pore range and might significantly alter the effective diffusion coefficient.
Im DIN-Normenausschuss Materialprüfung (NMP) wurde das Normungsgremium NA 062-08-28 AA „Qualifizierung von zerstörungsfreien Prüfungen“ reaktiviert. Das Ziel der Reaktivierung ist die Erarbeitung einer Norm für einen standardisierten Prozess zur probabilistischen Bewertung von Prüfverfahren.
In der zerstörungsfreien Prüfung (ZfP) führt die Ermittlung von Mess- / Prüfunsicherheiten von Prüfverfahren, in normativer Hinsicht in Deutschland und Europa, noch ein Schattendasein. Die Norm ISO IEC 17025 und auch der VDA-Band 5 wurden weiter in Richtung Messunsicherheit entwickelt, allerdings führt ihre Anwendung in der ZfP zu Problemen.
Der Arbeitsausschuss NA 062-08-28 AA soll hier den Brückenschlag zwischen Messunsicherheit, objektiver statistischer Bewertung für ZfP-Verfahren und eine weitere Stärkung der probabilistischen Bruchmechanik erreichen. Geplant ist daher die Erarbeitung einer DIN-Norm, welche die Kriterien für eine korrekte Versuchsplanung, ein praktikables Vorgehen zur Bewertung der Prüfergebnisse und die mathematische Überführung in eine Zuverlässigkeitsaussage enthält. Es soll ein Leitfaden erstellt werden, der für ein möglichst breites Branchenspektrum eingesetzt werden kann, unabhängig von den Besonderheiten verschiedener Industriezweige.
Dargestellt werden das relevante Normungsgremium sowie der Hintergrund des zu erstellenden Dokuments.
When reassessing existing concrete bridges, the challenge is often to obtain missing or incomplete information on the internal structure. In particular, the number and position of the existing reinforcement as well as the geometric dimensions of the components are of interest. Non-destructive testing methods, like radar or ultrasound, which work on the basis of the pulse-echo method, have been established for this purpose, as they only require access to the component from one side. The measurement data recorded on the structure require pre-processing to be able to reproduce the internal structure geometrically accurately. Besides different steps of data processing, the geometrical reconstruction of the measured data based on the Synthetic Aperture Focusing Technique (SAFT) is state of the art today. In this paper, the technical possibilities of the ultrasonic echo method are presented based on measurements in the laboratory and on a real bridge structure. The precision of the reconstruction and its limitations are shown. In addition to the state of the art SAFT technique, open questions and the latest research approaches, such as imaging by reverse time migration (RTM) including initial results are discussed.
When reassessing existing concrete bridges, the challenge is often to obtain missing or incomplete information on the internal structure. In particular, the number and position of the existing reinforcement as well as the geometric dimensions of the components are of interest. Non-destructive testing methods, like radar or ultrasound, which work on the basis of the pulse-echo method, have been established for this purpose, as they only require access to the component from one side. The measurement data recorded on the structure require pre-processing to be able to reproduce the internal structure geometrically accurately. Besides different steps of data processing, the geometrical reconstruction of the measured data based on the Synthetic Aperture Focusing Technique (SAFT) is state of the art today. In this paper, the technical possibilities of the ultrasonic echo method are presented based on measurements in the laboratory and on a real bridge structure. The precision of the reconstruction and its limitations are shown. In addition to the state of the art SAFT technique, open questions and the latest research approaches, such as imaging by reverse time migration (RTM) including initial results are discussed.
A major advantage in the reassessment of existing structures is the possibility of including measured data that describe the actual properties and the current condition of the structure to be reassessed. Currently, the incorporation of such measured information is mostly unregulated. However, the use of measurement results is vitally important, since a measured data-based improvement of the computation models level of approximation can lead at least to more meaningful results, possibly to extended remaining life times of the structure and in the best case to a saving of resources. Conversely, not appreciating well measurable and relevant information can be equated with a waste of resources. In this paper, a concept for the comparable use of non-destructively measured data as basic variables in probabilistic reliability assessments is outlined and examined using a typical prestressed concrete road bridge as a case-study. An essential requirement is the calculation of measurement uncertainties in order to evaluate the quality of the measurement results comparably. In conclusion, the example of ultrasonic and radar measurement data is used to demonstrate the effects that the incorporation of the measured information has on the reliability of the structure.
In this study, the wavefield radiated from a building to its surroundings is identified and extracted from M4.6 earthquake recordings collected by sensors installed in a building and on the nearby athletic field in Matera (Italy) using a new approach for soil-structure interaction assessment. The proposed approach for earthquake data analysis combines in an innovative way two methods already used in seismology and engineering seismology: deconvolution and polarization analysis. The approach enables the identification, reconstruction, and characterization of the wavefield radiated from a vibrating building into its surroundings, and the estimation of the amount of energy associated with it. The approach consists of four steps: estimation of the resonant frequencies of the building, deconvolution of the earthquake recordings from a building and its surroundings, identification of the seismic phases, reconstruction of the signal transmitted from the building to its surroundings, and estimation of its energy, and polarization analysis. Analysis of recordings of the M4.6 event highlighted that the motion related to the wavefield radiated from the building to the ground was mostly linearly polarized in the radial and transverse planes, while a clear ellipticity was observed only in the horizontal plane. The wavefield radiated from the building might be dominated by unconventionally polarized surface waves, i.e., quasi-Rayleigh waves or a combination of quasi-Rayleigh and quasi-Love waves. The results indicated that the energy transmitted from the analyzed vibrating building to its surroundings was significant and decreased the ground motion shaking due to the out-of-phase motion.
This presentation summarizes recent developments within the scope of the national pre-standardization project “ZfPStatik”, which aims to prepare a guideline about NDT-supported structural analyses. The focus is on the purposeful and explicit utilization of geometrical tendon and reinforcement bar positions measured on-site in reliability analysis — shown by means of a prestressed concrete bridge as case study.
Reliability assessment of existing concrete bridges with geometrical NDT results - Case studies
(2023)
The results of and the validity in reliability assessment of existing bridges essentially depend on the information available about the considered system. Information about the actual condition as well as structural and material characteristics can be observed on-site to refine the computation models used in assessment. Non-destructive testing (NDT) methods for concrete structures are capable of reconstructing missing, questioned, or inconsistent as-built plans. This contribution summarizes recent developments within the scope of the national pre-standardization project “ZfPStatik”, which aims to prepare a guideline about NDT-supported structural analyses. The focus is on the purposeful and explicit utilization of geometrical tendon and reinforcement bar positions (measured on-site using the ultrasound echo and ground penetrating radar (GPR) techniques) in probabilistic reliability analyses — shown by means of real case studies. The well-established first order reliability method is applied to different concrete bridges, which are typical for the German road bridge stock, to demonstrate the utility of incorporating quality-evaluated NDT-results in terms of changes in structural reliability.
Additive manufacturing of concrete structures is a novel and emerging technology. Free contouring in civil engineering, which allows for entirely new designs, is a significant advantage. In the future, lower construction costs are expected with increased construction speeds and decreasing required materials and workers. However, architects and civil engineers rely on a certain quality of execution to fulfil construction standards. Although several techniques and approaches demonstrate the advantages, quality control during printing is highly challenging and rarely applied. Due to the continuous mixing process commonly used in 3D concrete printing, it is impossible to exclude variations in the dry mixture or water content, and a test sample cannot be taken as a representative sample for the whole structure. Although mortar properties vary only locally, a defect in one layer during printing could affect the entire integrity of the whole structure . Therefore, real-time process monitoring is required to record and document the printing process. At the Bundesanstalt für Materialforschung und -prüfung (BAM) a new test rig for the additive manufacturing of concrete is built. The primary purpose is measuring and monitoring the properties of a mortar during the printing process. The following study investigates an approach for calculating yield stress and plastic viscosity based on experimentally recorded pressure data. The calculations assume that fresh mortar behaves as a Bingham fluid and that the Buckingham-Reiner-equation is applicable. A test setup consisting of rigid pipes with integrated pressure sensors at different positions is utilized. Monitoring the printing process with different sensors is crucial for the quality control of an ongoing process.
Zur Bewertung der Widerstandsfähigkeit von Schutzobjekten und Bauteilen gegen Explosionsbeanspruchung führt die Bundesanstalt für Materialforschung und -prüfung (BAM) regelmäßig Sprengversuche im Realmaßstab auf einem Testgelände durch.
Solche Versuche sind planungs- und ressourcenintensiv, sodass sie zunehmend durch numerische Simulationen ergänzt bzw. ersetzt werden.
Aktuelle Forschungsarbeiten zielen darauf ab, neue Berechnungsmethoden und Materialmodelle zu entwickeln, mit denen die Bestimmung der Bauteilantwort sowie die daraus resultierende Schädigung nach einem Explosionsereignis möglich sind.
Zur Validierung solcher Ansätze ist es notwendig, systematische Versuche mit unterschiedlichen Szenarien durchzuführen, bei denen die relevanten Parameter mit Hilfe verschiedener Messmethoden aufgezeichnet werden.
The ultrasonic echo technique is frequently used in non-destructive testing (NDT) of concrete structures for thickness measurements, geometry determinations as well as localization of built-in components. To improve ultrasonic imaging of complex structures in concrete, we transferred a geophysical imaging technique, the reverse time migration (RTM), to NDT in civil engineering. In contrast to the conventionally used synthetic aperture focusing technique (SAFT) algorithms, RTM is a wavefield continuation method in time and uses the full wave equation. Thus, RTM can handle complicated wave propagations in any direction without dip limitation. In this paper, we focused on the application and evaluation of a two-dimensional (2D) elastic RTM algorithm considering compressional waves, vertically polarized shear waves, and Rayleigh waves. We tested the elastic RTM routine on synthetic ultrasonic echo data generated with a 2D concrete model consisting of several steps and circular air inclusions. As these complex structures can often be found in real-world NDT use cases, their imaging is especially important. By using elastic RTM, we were able to clearly reproduce vertical reflectors and lower edges of circular air voids inside our numerical concrete model. Such structures cannot be imaged with conventional SAFT algorithms. Furthermore, the used elastic RTM approach also yielded a better reconstruction of a horizontal reflector and upper boundaries of circular air inclusions. Our encouraging results demonstrate that elastic RTM has the potential to significantly improve the imaging of complex concrete structures and, thus, is a step forward for detailed, high-quality ultrasonic NDT in civil engineering.
The Boltzmann plot method is widely used to determine the temperature of laser induced plasma. It involves the use of individual lines that are not easy to find in complex spectra and/or in the spectral range available. If the number of such lines is not enough to build a reliable Boltzmann plot, overlapping lines are often used, which are separated by software. However, line separation is a rather imprecise procedure, which, in addition, requires significant computational costs. This study proposes an extension of the Boltzmann plot method that allows a specific group of unresolved lines to be included in a Boltzmann plot without the need to separate them. This group of lines are multiplets, lines of the same element with similar upper and lower transition states. The multiplet lines along with the individual lines are included in the algorithm, which also includes a correction for self-absorption and is used to determine the plasma temperature. The algorithm is tested on synthetic spectra which are consistent with the model of a homogeneous isothermal plasma in local thermodynamic equilibrium and is shown to be superior to the standard Boltzmann plot method both in more accurate determination of the plasma temperature and in a significant reduction in the computational time. The advantages and disadvantages of the method are discussed in the context of its applications in laser induced breakdown spectroscopy.
Ultrasonic coda wave interferometry can detect small changes in scattering materials like concrete. We embedded ultrasonic transducers in the Gänstorbrücke Ulm, a monitored road bridge in Germany, to test the methodology. Since fall 2020, we've been monitoring parts of the bridge and comparing the results to commercial monitoring systems. We calculate signal and volumetric velocity changes using coda waves, and long-term measurements show that the influence of temperature on strains and ultrasound velocity changes can be monitored. Velocity change maps indicate that different parts of the bridge react differently to environmental temperature changes, revealing local material property differences. A load experiment with trucks allows calibration to improve detectability of possibly damaging events. Our work focuses on measurement reliability, potential use of and distinction from temperature effects, combination with complementary sensing systems, and converting measured values to information for damage and life cycle assessment.
Ultrasonic coda wave interferometry can detect small changes in scattering materials like concrete. We embedded ultrasonic transducers in the Gänstorbrücke Ulm, a monitored road bridge in Germany, to test the methodology. Since fall 2020, we've been monitoring parts of the bridge and comparing the results to commercial monitoring systems. We calculate signal and volumetric velocity changes using coda waves, and long-term measurements show that the influence of temperature on strains and ultrasound velocity changes can be monitored. Velocity change maps indicate that different parts of the bridge react differently to environmental temperature changes, revealing local material property differences. A load experiment with trucks allows calibration to improve detectability of possibly damaging events. Our work focuses on measurement reliability, potential use of and distinction from temperature effects, combination with complementary sensing systems, and converting measured values to information for damage and life cycle assessment.
Ultrasonic inspection, especially contact and immersion methods, have become established techniques for non-destructive testing in civil engineering (NDT-CE). However, the requirement for coupling agents renders these methods cumbersome in practice due to the potential for surface defacement and an arduous measurement process. Consequently, air-coupled ultrasonic transducers have been proposed as an alternative to address these concerns. These (alternatives), however, come with their own challenges, such as a significant impedance mismatch between the air and the specimen as well as the susceptibility of time of flight (TOF) measurements to ambient conditions. Recently, fluidic oscillators have been developed for in-air sound generation to alleviate impedance mismatch and improve the overall robustness, which is an important consideration of NDT-CE applications. The advantage of fluidic oscillators lies in their ability to generate an ultrasonic signal via oscillating air jet excited by a self-actuated fluctuation. Using air as the operating medium provides a supplementary benefit of lowering measurement durations in addition to a substantial drop in acoustic impedance losses with air acting both as an actuation as well as a coupling medium. Thus, TOF measurements using such fluidic transducers are expected to enable faster characterization of specimen parameters.
In that regard, material characterization of polyamide is carried out using ultrasound generated by fluidic devices. Additionally, the mass flow rate of the operating fluid is observed to have a significant effect on the frequency of the fluidic oscillator. Accordingly, the frequency of the oscillation is modulated by varying the supply pressure, leading to a varying flow rate, which in turn facilitates a robust and reliable assessment of the TOF through the material by the generated chirp signals. Furthermore, such frequency modulations effectively improve the signal-to-noise ratio (SNR). Along with a comprehensive study of these new fluidic transducers, preliminary measurement findings are presented, including the material characterization of polymers using air-coupled, frequency-modulated ultrasound.
Im Rahmen des Seminars "Angewandte Forschungsthemen (SAFT)" am Institut für Geowissenschaften der Christian-Albrechts-Universität zu Kiel werden verschiedene geophysikalische Methoden vorgestellt, die bei der zerstörungsfreien Prüfung im Bauwesen zum Einsatz kommen. Neben einem Überblick der Arbeiten an der BAM im Allgemeinen und dem Fachbereich im Besonderen geht es vor allem um den Einsatz von Ultraschallmethoden. Drei wesentliche Schwerpunkte werden dabei beleuchtet:
1) (Geophysikalische) Antworten auf Herausforderungen bei Ultraschall-Anwendungen
2) Material research and multi-sensory monitoring for concrete sealing structures in rock salt unterground repositories (Projekt SealWasteSafe)
und 3) Untersuchung von Spritzbeton-Probekörpern unter Tage mit Ultraschall zur Qualitätssicherung von Verschlussbauwerken.
Insgesamt werden diverse Möglichkeiten für die Geophysik für Forschung und Studierende im Bereich der zerstörungsfreien Prüfung im Bauwesen aufgezeigt.
Moisture testing and mapping
(2023)