8.1 Sensorik, mess- und prüftechnische Verfahren
Filtern
Dokumenttyp
Sprache
- Englisch (47)
Referierte Publikation
- ja (47) (entfernen)
Schlagworte
- Electronic nose (4)
- Nano aerial robot (4)
- TDLAS (4)
- Aerial robot (3)
- Gas tomography (3)
- Plume (3)
- ANOVA (2)
- Adjustment calculation (2)
- Bending (2)
- Chemometric techniques (2)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (47)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (47)
- 7 Bauwerkssicherheit (6)
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.9 Chemische und optische Sensorik (4)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 3 Gefahrgutumschließungen; Energiespeicher (4)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (3)
- 2.2 Prozesssimulation (2)
Paper des Monats
- ja (4)
Till now application of printed magnetoelectronics is hindered by lack of large area exchange coupled metallic multilayers required to produce printable magneto-sensory inks. Large-scale roll-to-roll (R2R) fabrication process is an attractive approach owing to its capabilities for high volume, high throughput, and large area manufacturing. Precise and high performance R2R sputtering technology is developed to fabricate large area giant magnetoresistive (GMR) thin-films stacks that contain 30 metallic bilayers prepared by continuous R2R sputtering of Co and Cu sequential on a hundred meters long polyethylene terephthalate (PET) web. The R2R sputtered Co/Cu multilayer on a 0.2 × 100 m2 PET web exhibits a GMR ratio of ≈40% achieving the largest area exchange coupled room temperature magneto-sensitive system demonstrated to date. The prepared GMR thin-film is converted to magnetosensitive ink that enables printing of magnetic sensors with high performance in a cost-efficient way, which promotes integration with printed electronics. An average GMR ratio of ≈18% is obtained for 370 printed magnetic sensors. The realized precise R2R sputtering approach can also be extended to a wide range of hybrid thin-film material systems opening up a path for new functional inks applied with printing technologies.
The finite volume method (FVM), like the finite element method (FEM), is a numerical method for determining an approximate solution for partial differential equations. The derivation of the two methods is based on very different considerations, as they have historically evolved from two distinct engineering disciplines, namely solid mechanics and fluid mechanics. This makes FVM difficult to learn for someone familiar with FEM. In this paper we want to show that a slight modification of the FEM procedure leads to an alternative derivation of the FVM. Both numerical methods are starting from the same strong formulation of the problem represented by differential equations, which are only satisfied by their exact solution. For an approximation of the exact solution, the strong formulation must be converted to a so-called weak form. From here on, the two numerical methods differ. By appropriate choice of the trial function and the test function, we can obtain different numerical methods for solving the weak formulation of the problem. While typically in FEM the basis functions of the trial function and test function are identical, in FVM they are chosen differently. In this paper, we show which trial and test function must be chosen to derive the FVM alternatively: The trial function of the FVM is a “shifted” trial function of the FEM, where the nodal points are now located in the middle of an integration interval rather than at the ends. Moreover, the basis functions of the test function are no longer the same as those of the trial function as in the FEM, but are shown to be a constant equal to 1. This is demonstrated by the example of a 1D Poisson equation.
The mechanical and geometrical properties of impact targets greatly influence the outcome of a drop test. The International Agreement concerning the International Carriage of Dangerous Goods by Road (ADR) as well as ISO 2248 describe the characteristics of impact targets for drop tests of dangerous goods packagings.
According to these regulations, the impact target’s surface needs to be unyielding, under testing conditions non-deformable, flat, and integral with a mass at least 50 times that of the heaviest packaging to be tested. The problem is that many production facilities, especially manufacturers of corrugated fibreboard boxes, do not have their own testing device with the required 50 times mass ratio of the impact target for a regulation compliant drop test during series production. Furthermore, at UN level it is considered necessary to revise these requirements.
In the present paper, the impact target requirements are examined in detail and compared with those in other technical areas (e.g., impact target for container for the transport of radioactive materials). A research method is being developed to investigate the dependency between the mass ratio of the packaging and the target as well as the damage resistance of a drop tested package in relation to specific design characteristics. The results are of high relevance for industry purposes and intended to ensure a uniform level of safety assessment for the mechanical testing of dangerous goods packagings.
Gas distribution mapping is important to have an accurate understanding of gas concentration levels in hazardous environments. A major problem is that in-situ gas sensors are only able to measure concentrations at their specific location. The gas distribution in-between the sampling locations must therefore be modeled. In this research, we interpret the task of spatial interpolation between sparsely distributed sensors as a task of enhancing an image's resolution, namely super-resolution. Because autoencoders are proven to perform well for this super-resolution task, we trained a convolutional encoder-decoder neural network to map the gas distribution over a spatially sparse sensor network. Due to the difficulty to collect real-world gas distribution data and missing ground truth, we used synthetic data generated with a gas distribution simulator for training and evaluation of the model. Our results show that the neural network was able to learn the behavior of gas plumes and outperforms simpler interpolation techniques.
Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or poorly accessible areas. A challenging task however, is the generation of three-dimensional distribution maps from these spatially sparse gas measurements. To obtain high-quality reconstructions, the choice of optimal measuring poses is of great importance. Remote gas sensors, that are commonly used in Robot Assisted Gas Tomography (RAGT), require reflecting surfaces within the sensor’s range, limiting the possible sensing geometries, regardless of whether the robots are ground-based or airborne. By combining ground and aerial robots into a heterogeneous swarm whose agents are equipped with reflectors and remote gas sensors, remote inter-robot gas measurements become available, taking RAGT to the next dimension – releasing those constraints. In this paper, we demonstrate the feasibility of drone-to-drone measurements under realistic conditions and highlight the resulting opportunities.
Monitoring of repositories for radioactive waste requires techniques which can be applied long-term under harsh conditions. In this work, the reliability and suitability of materials and a capacitive sensor for measuring relative humidity are investigated, which are to be embedded in the special concrete components for the closure structures of underground repository. Preliminary tests with accelerated aging of the materials used, validation of the sensors under difficult conditions, investigations of the surfaces after aging by pH 14 solution, defined exposure of the sensors in a climatic chamber and the microscope images are discussed. The results will be used for further development and optimization of the RFID based sensor systems which can be applied to monitor the condition of different building structures without cabling.
This paper presents first advances in the area of aerial chemical trail following. For that purpose, we equipped a palm-size aerial robot, based on the Crazyflie 2.0 quadrocopter, with a small lightweight metal oxide gas sensor for measuring evaporated ethanol from chemical trails. To detect and localize a 5 cm wide chemical trail, a detection criterion was developed that uses only relative changes in the transient phase of the sensor response. The reduction in signal strength dependence improves the robustness of its application. We tested our setup in first crossing-trail experiments showing that our flying ant robot can correlate an odor hit with the chemical trail within 0.14 m. Principally, this could enable aerial chemical trail following in the future.
Wireless sensor networks provide occupational health experts with valuable information about the distribution of air pollutants in an environment. However, especially low-cost sensors may produce faulty measurements or fail completely. Consequently, not only spatial coverage but also redundancy should be a design criterion for the deployment of a sensor network. For a sensor network deployed in a steel factory, we analyze the correlations between sensors and build machine learning forecasting models, to investigate how well the sensor network can compensate for the outage of sensors. While our results show promising prediction quality of the models, they also indicate the presence of spatially very limited events. We, therefore, conclude that initial measurements with, e.g., mobile units, could help to identify important locations to design redundant sensor networks.
This paper presents first advances in the area of aerial chemical trail following. For that purpose, we equipped a palm-size aerial robot, based on the Crazyflie 2.0 quadrocopter, with a small lightweight metal oxide gas sensor for measuring evaporated ethanol from chemical trails. To detect and localize the chemical trail, a novel detection criterion was developed that uses only relative changes in the transient phase of the sensor response, making it more robust in its application. We tested our setup in first crossing-trail experiments showing that our flying ant robot is able to correlate an odor hit with the chemical trail within 0.14 m. Principally, this could enable aerial chemical trail following in the future.
Poor air quality, particularly in urban areas, causes various diseases and degrades living standards. Air Quality could be affected by emissions of odor, Volatile Organic Compounds (VOCs), and other gases. Therefore, assessment and monitoring of odorous air quality using sensitive, simple, rapid, accurate and portable tools is very important for public health. This study aimed to characterize odor emissions to detect malfunctions in facilities and to prevent air pollution and olfactory nuisance in the environment. A gas chromatographic method, in conjunction with sensorial analysis were performed for odorous air samples analysis collected from neighborhood of Meknes city (Morocco). Advanced multivariate statistical approaches, such as Principal Components Analysis (PCA), Discriminant Function Analysis (DFA), Support Vector Machines (SVMs), and Hierarchical Cluster Analysis (HCA), were used to describe samples similarities. The electronic nose (e-nose) data processing exhibits a satisfactory discrimination between the odorous air samples. Twenty-four VOCs with known molecular formulas were identified with Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS). A validated Partial Least Square (PLS) model foresees good calibration between e-nose measurement and TD-GCMS analysis. The finding indicates that TD-GC–MS approach in conjunction with e-nose unit could be suitable tool for environmental measurement-based odor emissions.