8.1 Sensorik, mess- und prüftechnische Verfahren
Filtern
Dokumenttyp
Sprache
- Englisch (8)
Referierte Publikation
- ja (8) (entfernen)
Schlagworte
- Dangerous goods packagings (2)
- Drop test (2)
- Fluorescence (2)
- Impact target (2)
- Structural dynamics (2)
- Alkali-activated mortars (1)
- Civil engineering (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- Corrugated fibreboard box (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (8)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (8)
- 1 Analytische Chemie; Referenzmaterialien (4)
- 1.9 Chemische und optische Sensorik (4)
- 3 Gefahrgutumschließungen; Energiespeicher (2)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (2)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 8.6 Faseroptische Sensorik (1)
- VP Vizepräsident (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (2)
With the reduction of large oil spills because of stricter regulations and safety measures, the question of how to manage smaller oil spills arises. Few on-site analytical tools are available for first responders or other law enforcement personnel to rapidly test for crude oil in the early management of localized polluted areas. The approach reported here relies on well-described computer-assisted multivariate data analysis of the intrinsic fluorescence fingerprints of crude oils to build a multivariate model for the rapid classification of crude oils and the prediction of their properties. Thanks to a dedicated robust portable reader, the method allowed classification and accurate prediction of various properties of crude oil samples like density (according to API, the American Petroleum Institute and viscosity as well as composition parameters such as volume fractions of paraffins or aromatics. In this way, autonomous operation in on-site or in-the-field applications becomes possible based on the direct (undiluted and untreated) measurement of samples and a rapid, tablet-operated readout system to yield a robust and simple analytical test with superior performance. Testing in real-life scenarios allowed the successful classification and prediction of a number of oil spill samples as well as weathered samples that closely resemble samples collected by first responders.
Contamination of natural bodies of water or soil with oils and lubricants (or generally, hydrocarbon derivatives such as petrol, fuels, and others) is a commonly found phenomenon around the world due to the extensive production, transfer, and use of fossil fuels. In this work, we develop a simple system for the on-field detection of total petroleum hydrocarbons (TPHs) in water and soil. The test is based on the measurement of the fluorescence signal emitted by the molecular rotor 2-[ethyl[4-[2-(4-nitrophenyl)ethenyl]phenyl]amino]ethanol (4-DNS-OH). This dye is embedded in a hydrophobic polymeric matrix (polyvinylidene fluoride), avoiding interactions with water and providing a robust support for use in a test strip fashion. Together with the strips, an embedded optical system was designed for fluorescence signal read-out, featuring a Bluetooth low-energy connection to a commercial tablet device for data processing and analysis. This system works for the detection and quantification of TPHs in water and soil through a simple extraction protocol using a cycloalkane solvent with a limit of detection of 6 ppm. Assays in surface and sea waters were conclusive, proving the feasibility of the method for in-the-field operation.
For dangerous goods packagings, drop testing onto an essential unyielding target can be used to assess the mechanical resistance to impact loads. Adopted regulations like ADR/RID require that the impact surface provided shall be integral with a mass at least 50 times than that of the heaviest package to be tested. The problem is that many manufacturers do not possess impact targets that satisfy the required 50 times mass ratio for regulative drop tests during series production. The objective of this work is to verify existing and define improved criteria for impact target structures based on systematic investigations. Previous evidence highlights the relevance of other parameters in addition to the mass ratio. Therefore, in this research, a variation of drop test parameters was carried out experimentally. Furthermore, numerical vibration analysis was applied to investigate the deformability of the impact surface. The results conclude that the mass ratio of 1:50 cannot be defined as a decisive criterion. In order to determine the influence of further drop test parameters, the research findings were used to validate a parametric model which assesses impact target deflection. An approximation quality of over 90 % was achieved. As a result, new evaluation criteria are proposed. Firstly, a method for identifying critical impact target designs is provided. Secondly, a new comprehensive formula compares the approximated maximum deflection of a real impact target to the respective theoretical threshold derived from a worst-case assumption. In practice, this leads to great advantages in the evaluation of already installed impact targets for dangerous goods packagings.
The mechanical and geometrical properties of impact targets greatly influence the outcome of a drop test. The International Agreement concerning the International Carriage of Dangerous Goods by Road (ADR) as well as ISO 2248 describe the characteristics of impact targets for drop tests of dangerous goods packagings.
According to these regulations, the impact target’s surface needs to be unyielding, under testing conditions non-deformable, flat, and integral with a mass at least 50 times that of the heaviest packaging to be tested. The problem is that many production facilities, especially manufacturers of corrugated fibreboard boxes, do not have their own testing device with the required 50 times mass ratio of the impact target for a regulation compliant drop test during series production. Furthermore, at UN level it is considered necessary to revise these requirements.
In the present paper, the impact target requirements are examined in detail and compared with those in other technical areas (e.g., impact target for container for the transport of radioactive materials). A research method is being developed to investigate the dependency between the mass ratio of the packaging and the target as well as the damage resistance of a drop tested package in relation to specific design characteristics. The results are of high relevance for industry purposes and intended to ensure a uniform level of safety assessment for the mechanical testing of dangerous goods packagings.
Monitoring of repositories for radioactive waste requires techniques which can be applied long-term under harsh conditions. In this work, the reliability and suitability of materials and a capacitive sensor for measuring relative humidity are investigated, which are to be embedded in the special concrete components for the closure structures of underground repository. Preliminary tests with accelerated aging of the materials used, validation of the sensors under difficult conditions, investigations of the surfaces after aging by pH 14 solution, defined exposure of the sensors in a climatic chamber and the microscope images are discussed. The results will be used for further development and optimization of the RFID based sensor systems which can be applied to monitor the condition of different building structures without cabling.
In civil engineering, many structures are made of reinforced concrete. Most Degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture.
Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days.
Moreover, long-term moisture monitoring is performed for more than 1000 days. The Experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.
This paper describes the development of a semi-automatic gas measurement device presenting potentially a broad range of applications, noteworthy in the agricultural sector. Non-reversible fluorescent molecular sensors were designed and syn-thesized. Upon, integration into a hydrogel matrix with an optimal ratio of co-solvents, the sensors reacting selectively to ammonia were illuminated by excitation light to produce a concentration-correlated fluorescence emission. An automated mechanical-elec-trical device initiates a given gas mixture and thus simulates con-centrations similar to a threshold value. The aim of this project is to develop a sensor or a low-cost method which can monitor low concentrations of harmful gases and aid in their elimination or regulation in livestock housing, barns or stables.
This paper describes a wireless mobile prototype able to perform optical measurements by means of a miniatur-ized spectrometer for low light analysis, e.g. fluorescent sensors. Evaluations, calculations, calibration management and result display are performed by a computer or a standard tablet. The device was designed primarily to detect traces of oil in drinking or ground water and for the analyses of crude oils. However, it can also address a wide range of fluorescent sensors. The fast and user-friendly inspection of water quality or oil properties, as well as the adaptability and mobility, make the device attractive for a variety of users. Further application areas could be easily imple-mented by adapting the optics and the software (database, data processing and calibration plots, etc.)