8 Zerstörungsfreie Prüfung
Filtern
Dokumenttyp
Schlagworte
- Ultrasound (112) (entfernen)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (38)
Air-coupled ultrasonic testing is widely used in the industry for the non-destructive testing of compound materials. It provides a fast and efficient way to inspect large concrete civil infrastructures for damage that might lead to catastrophic failure. Due to the large penetration depths required for concrete structures, the use of traditional piezoelectric transducer requires high power electric systems. In this study, a novel fluidic transducer based on a bistable fluidic amplifier is investigated. Previous experiments have shown that the switching action of the device produces a high-power broadband ultrasonic signal. This study will provide further insight into the switching behaviour of the fluidic switch. Therefore, parametric CFD simulations based on compressible supersonic RANS simulations were performed, varying the inlet pressure and velocity profiles for the control flow. Switching times are analyzed with different methods, and it was found that These are mostly independent of the slope of the velocity profile at the control port. Furthermore, it was found that an inversely proportional relationship exists between flow velocity in the throat and the switching time. The results agree with the theoretical background established by experimental studies that can be found in the literature.
This paper summarizes the results of research aimed at assessing cracks in reinforced concrete structures using embedded ultrasonic sensors. The diffuse ultrasonic waves were considered to evaluate the health status of the tested structures. There are different algorithms used to detect cracks in the structure, but most studies have been performed on benchmark reinforced concrete (RC) structures and in laboratory conditions. Since there were difficulties with the validity of Damage detection in real structures in the presence of environmental changes and noises, the application of advanced signal processing methods was necessary. Therefore, the wavelet transform was applied to process ultrasonic signals acquired from multiple civil structures. It is shown that the ultrasonic sensors with an applied wavelet transform algorithm on collected signals can successfully detect cracks in the laboratory as well as in a real environment. Experimental results showed a perfect match for detecting damage and quasi-static load in the presence of environmental changes. The results were confirmed with other techniques. In addition, designing an extra filter for removing noises can be avoided by using the applied algorithms. The obtained results confirmed that diffuse ultrasonic sensor methodology with the proposed algorithm is useful and effective in Monitoring real RC structures, and it is better than traditional techniques.
The simulation of ultrasonic waves in a linearly elastic body can be computationally intensive. The reason is the relatively short wavelength compared to the body size for high frequencies. One possible approach to counteract the high computational costs is to decompose the domain into small parts and strive for parallelization. The Mortar Method is a well-established approach for domain decomposition.
A rather new approach to discretize the emerging subdomains is the Scaled Boundary Finite Element Method. This semi-analytical method has many attractive properties. Some of these properties are listed subsequently. The grid consists of polygonal elements, which leaves much freedom in the meshing process. A variety of material distributions, including anisotropic materials, can be considered. High-order shape functions can be used for optimal convergence properties. The approach treats singularities at crack tips and corners analytically. Especially in the frequency domain, the Scaled Boundary Finite Element Method reduces the dimension of the approximation because only degrees of freedom which are associated with the boundary of a polygonal element are necessary. Those desirable properties make the method particularly suitable for calculating the dynamic responses in bodies with cracks, as it is essential for many non-destructive testing and structural health monitoring applications.
In this contribution, we present a combination of the Scaled Boundary Finite Element Method with the Mortar Method in two dimensions. The presentation starts with a theoretical overview of both approaches. Subsequently, numerical examples demonstrate the stability of the combination for the polygonal boundary of the elements. The numerical examples increase in complexity and are compared to results computed on non-divided domains with the Finite Element Method.
Monitoring of reinforced concrete structures to ensure their stability and increase their service-life is a crucial element of a modern infrastructural concept. With classical methods of non-destructive testing and inspection, repeated measurements under comparable conditions are difficult to conduct. Therefore, DFG research unit FOR 2825 CoDA researches the assessment of concrete damage using ultrasound coda wave interferometry and embedded sensors. Embedding the sensors into the monitoring target reduces human and non-human factors influencing repeatability. Using Coda Wave Interferometry (CWI), small velocity changes in the material can be detected by comparison of repeated measurements. The technique is sensitive to damaging changes like cracking as well as to reversible influences like material temperature. The understanding of these different influences on the signal is crucial for the analysis of long-term monitoring data to make an educated assessment of the structure and its integrity. With several laboratory experiments in a climate chamber and a long-term experiment recording an annual cycle in a large model on an outdoor test site in Horstwalde close to Berlin, we try to understand the influence of temperature on the CWI results. The results show that the velocity change calculated by CWI does closely follow the trend of concrete temperature. After one year of data recording with the large model being exposed to environmental variations only, the calculated velocity change resembles the annual temperature curve. The data shows a linear dependency between velocity and temperature change in a range of -0.03 percent per °K to -0.06 percent per °K - regardless of specimen size. An approach to remove temperature influence from the yearly cycle recorded in the large-scale experiment using this linear relation is unable to remove high-frequency variations - especially daily influences. Low-pass filtering the data can eliminate these variations while preserving permanent shifts caused by damages. Although we have shown that the influence of temperature on long term monitoring can be removed to a significant extent, there is still an influence of environmental changes remaining in the data. Possible nonlinear effects and influences not related to temperature need to be investigated in the future.
With a goal to improve our understanding of the relationships between microstructural features and ultrasonic signal behavior, concrete specimens of varying water-to-cement ratio were imaged using X-ray computed tomography (CT), and subsequently subjected to ultrasonic testing. From the CT scans, measurements were made of cement paste density and number of interfaces. Ultrasonic signals produced using a through-transmission configuration were analyzed and fit to a diffusion model to separate absorption from scattering attenuation. The results showed that at the frequencies tested, ultrasonic dissipation rate correlated weakly with paste density, while diffusivity correlated well with number of interfaces, but only if entrained air is considered separately. Cement paste density was found to be very well predicted by diffusivity, leading to a clear power-law relationship between diffusivity and compressive strength.
Reinforced concrete bridges are iconic parts of modern infrastructure. They are designed for a minimum service life of 100 years. However, environmental factors and/or inappropriate use might cause overload and accelerate the deterioration of bridges. In extreme cases, bridges could collapse when necessary maintenance lacks. Thus, the permanent monitoring for structure health assessment has been proposed, which is the aim of structural health monitoring (SHM). Studies in laboratories have shown that ultrasonic (US) coda wave interferometry (CWI) using diffuse waves has high sensitivity and reliability to detect subtle changes in concrete structures. The creation of micro-cracks might be recognized at an early stage. Moreover, large-volume structures can be monitored with a relatively small number of US transducers. However, it is still a challenge to implement the CWI method in real SHM practical applications in an outdoor environment because of the complex external factors, such as various noise sources that interfere with the recorded signals. In this paper, monitoring data from a 36-m long bridge girder in Gliwice, Poland, instrumented with embedded US transducers, thermistors, and vibrating wire strain gauges, is presented. Noise estimation and reductionmethods are discussed, and the influence of traffic, as well as temperature variation, are studied. As a result, the relative velocity variation of US waves following the temperature change with a very high precision of 10−4% is shown, and a good bridge health condition is inferred. The influence of lightweight real traffic is negligible. The study verified the feasibility of the implementation of the CWI method on real bridge structures.
Due to the importance of reinforced concrete structures for modern society, damage assessment during the entire life-cycle of such structures has become a special interest in non-destructive testing. Using embedded ultrasound sensors in combination with other measurement methods, numerical modeling and self-made data collectors, tailored specifically for monitoring tasks, the German research group DFG FOR CoDA aims to investigate and develop novel methods for damage detection and rapid model updating in reinforced concrete structures. In the first stage of the project, besides the development of custom-built, low-cost data collectors, ultrasonic transducers are embedded in a large, reinforced concrete specimen on a BAM test site near Berlin. In this experiment, the influence of changing environmental conditions (mainly temperature) on the ultrasound signal is investigated using coda-wave interferometry. The results show a correlation between changes in temperature and ultrasonic velocity. Such changes must be taken into consideration in a long-term monitoring setup to distinguish between reversible and permanent changes. By correcting the data using a linear relation between concrete temperature and velocity change to remove the seasonal trends and by low-pass filtering the data to remove daily variations can remove most of the temperature influence on the ultrasound measurements.
Due to increasing ageing, deterioration and loading , several prestressed concrete bridges bulit in the 1950ies and 1960ies need monitoring. Recently several bridges have sucesssfully equipped with acoustic emission sensing system. BAM works together with several universities on an add onn: Active ultrasonic monitoring combined with coda wave interferometry will help to detect subtle changes and precursors fo failure earlier than other methods.
Recent years have seen extended use of ultrasonic techniques for concrete infrastructure assessement. They are applied for quality assurance and condition assessement at bridges, power plants, dams and other important objects. However, there are still a couple of significant limitations. They include, but are not limited to depth of penetration, imaging complex structures or early stage detections of distributed damage. The talk will give information on recent research in this area. Specifically, the application of the unique deep penetration system LAUS is shown. Ultrasonic monitoring using embedded transducers to check for subtle and sudden changes in the material is introduced as well. Comments on initiatives for validation, standardization and certification will be given.
Monitoring of Concrete with Embedded Ultrasound Sensors, Coda Waves and a Novel Measurement Device
(2020)
Using embedded ultrasound (US) sensors in civil engineering structures and Coda Wave Interferometry (CWI), DFG research group CoDA aims for developing methods of concrete damage assessment by combination of Micro and macro scale simulations and experiments. BAMs goal within the project is the provision of small and durable measurement equipment on the one hand, and the investigation of damage sensitive parameters and development of an imaging algorithm on the other hand. In this study we focus on the development of the measurement system and the influence of temperature variations on the measurements.
Entwicklung eines luftgekoppelten Ultraschall-Echo-Prüfverfahrens mittels fluidischer Anregung
(2020)
In vielen technischen Bereichen werden Ultraschallverfahren zur zerstörungsfreien Werkstoffprüfung (ZfP) eingesetzt um auf Basis der Signalstärke und der Laufzeit Einbauteile und Beschädigungen zu orten. Luftgekoppelter Ultraschall spielt bisher in kommerziellen Anwendungen vor Allem im Bauwesen eine untergeordnete Rolle, da die Differenz der akustischen Impedanzen von Luft und Festkörpern immense Verluste beim Übergang des Schallsignals hervorruft.
Im Rahmen des Promotionsvorhabens soll die Eignung eines neuartigen Anregungsprinzip untersucht werden, mit dem ein Großteil dieser Verluste vermieden werden soll. Anstelle eines Festkörpers soll mit Hilfe einer fluidischen Düse Druckluft zur Signalerzeugung eingesetzt werden. Die Impedanzverluste zwischen Aktuatormembran und Umgebungsluft entfallen daher.
Die gezielte Schallerzeugung durch einen pulsierenden Freistrahl ist weitgehend unerforscht. Es ist daher notwendig, den so erzeugten Schallpuls in der Interaktion mit dem transienten Strömungsfeld zu untersuchen. Das kompressible Medium Luft und die geringen räumlichen Dimensionen einer hochfrequenten Pulsdüse werfen darüber hinaus einige Herausforderungen hinsichtlich der eingesetzten Messtechnik auf. Hier sollen geeignete Verfahren weiterentwickelt und validiert werden, um die Eignung des fluidisch erzeugten Pulses zu überprüfen.
In diesem Vortrag werden erste Messungen an einem fluidischen Schalter mit denen an einem kommerziellen Luftultraschallprüfkopf verglichen.
Due to the high sensitivity of coda waves to the smallest structural alterations such as strain, humidity or temperature changes, ultrasonic waves are a valid means to examine entire structures employing networks of ultrasonic transducers. In order to substantiate this ex ante assessment, the viability of measuring ultrasonic waves as a valid point of reference and inference for structural changes is to be further scrutinized in this work. In order to investigate the influence of mechanical strain on ultrasonic signals, a four-point bending test was carried out on a reinforced concrete beam at Ruhr University Bochum. Thus, measurements collected from a network of selected transducer pairings arranged across the central, shear-free segment of the test specimen, were correlated to their respective strain fields. Detected ultrasonic signals were evaluated employing Coda Wave Interferometry. Such analysis comprised the initial non-cracked state as well as later stages with incremental crack depth and quantity. It was to ascertain that the test specimen can in fact be qualitatively compartmentalized into areas of compression and tension identified via Relative Velocity Changes presented in Attribute Maps. However, since results did not entail a zero crossing, i.e., neither positive nor negative values were to be calculated, only relative changes in this work displayed staggered over the height of the object under test, are discussed. Under the given methodological premises, additional information is currently required to make quantitative assertions regarding this correlation of ultrasonic and strain results. This holds true for the comparability of the ultrasonic and strain results for both non-cracked and even the cracked state.
Air-coupled ultrasound was used for assessing natural defects in wood boards by through-transmission scanning measurements. Gas matrix piezoelectric (GMP) and ferroelectret (FE) transducers were studied. The study also included tests with additional bias voltage with the ferroelectret receivers. Signal analyses, analyses of the measurement dynamics and statistical analyses of the signal parameters were conducted. After the measurement series, the samples were cut from the measurement regions and the defects were analyzed visually from the cross sections. The ultrasound responses were compared with the results of the visual examination of the cross sections. With the additional bias voltage, the ferroelectret measurement showed increased signal-to-noise ratio, which is especially important for air-coupled measurement of high-attenuation materials like wood. When comparing the defect response of GMP and FE sensors, it was found that FE sensors had more sensitive dynamic range, resulting from better s/n ratio and short response pulse. Classification test was made to test the possibility of detecting defects in sound wood. Machine learning methods including decision trees, k-nearest neighbor and support vector machine were used. The classification accuracy varied between 72 and 77% in the tests. All the tested machine learning methods could be used efficiently for the classification.
Monitoring of concrete structures is of utmost importance in maintenance and preservation of infrastructure. As a part of the DFG research group CoDA (Concrete Damage Assessment by Coda Waves), the works within this PhD project aim for identification of damage sensitive parameters extracted from ultrasonic measurements obtained with embedded sensors, the determination of environmental (reversible) influences on the signal and the localisation of damaged areas. The main technique used for the detection of changes in the monitored material is the so-called Coda Wave Interferometry (CWI). It uses the later part of the ultrasonic recording for the detection of small changes in the sensed area and the calculation of a relative velocity change. Using this technique we can show that we are able to detect changes in concrete temperature with ultrasound measurements. This enables temperature correction for ultrasound monitoring with embedded sensors. The crucial point for imaging and localisation with coda waves is the calculation of the so-called sensitivity kernels. We propose the application of numerical wave simulations for the kernel calculations instead of the commonly used diffusivity equation. Using finite-difference wave modelling code from our DFG project partners we are able to calculate those Kernels and first results are shown in this presentation. The major task for the second year will be the development and implementation of the inversion algorithm as well as the preparation of validation experiments.
Imaging wood defects using air coupled ferroelectret ultrasonic transducers in reflection mode
(2020)
Air-coupled ultrasound (ACU) is used to detect defects in wood panels without physically contacting the sample and with a quick scanning rate. Transducers made of cellular polypropylene (PP) with a high signal-to-noise ratio are quite suitable for ACU testing of wood. The extremely low modulus of elasticity and low density of PP transducers results in a small difference in acoustic impedance for the Transmission of ultrasonic waves between the transducer and air, allowing new areas of application to become possible.
To demonstrate the suitability of the reflection technique, measurements are shown on the three samples Multiplex, LVL, and MDF and compared with transmission measurements. Due to this acoustic barrier and the use of cellular PP transducers, an exact detection of delamination and cavities is possible in wood panels up to 40 mm thick. If only one side of an object is accessible and the depth of the defect is of interest, the reflection technique is preferred at the expense of a reduced measuring accuracy and Penetration depth.
Rail inspection performed by ultrasonic rail inspection trains is a complex and challenging process. A large number of variables and parameters given by the environment, the track and the testing-system have an influence on the overall performance of the inspection and the inspection result. Typically the parameter vary in a combination depending on the track condition.
To evaluate the individual influence of each relevant variable, simulation tools can be used. Therefore the entire inspection process has to be transferred into a model using combined modelling techniques.
The goal of this work is to model an instrumented ultrasonic test run with a rail inspection train with the parameters varied by a script over a virtually driven distance.
Rail inspection performed by ultrasonic rail inspection trains is a complex and challenging process. A large number of variables and parameters given by the environment, the track and the testing-system have an influence on the overall performance of the inspection and the inspection result. Typically the parameter vary in a combination depending on the track condition.
To evaluate the individual influence of each relevant variable, simulation tools can be used. Therefore the entire inspection process has to be transferred into a model using combined modelling techniques.
The goal of this work is to model an instrumented ultrasonic test run with a rail inspection train with the parameters varied by a script over a virtually driven distance.