In ultrasonic testing, material and structural properties of a specimen can be derived from the time-of-flight (ToF). Using signal features, such as the first peak or envelope maximum, to calculate the ToF is error-prone in multipath arrangements or dispersive and attenuating materials, which is not the case for the signal onset. Borrowing from seismology, researchers used the Akaike information criterion (AIC) picker to automatically determine onset times. The most commonly used formulation, Maeda's AIC picker, is reassessed and found to be based on inappropriate assumptions for signals often used in ultrasonic testing and dependent on arbitrary parameters. Consequently, an onset picker for ultrasonic through-transmission measurements is proposed, based on a spectral entropy criterion (SEC) to model the signal using the AIC framework. This SEC picker takes into account the spectral properties of the ultrasonic signal and is virtually free of arbitrary parameters. Synthetic and experimental data are used to compare the performance of SEC and AIC pickers. It is shown that the accuracy of onset picking is improved for densely sampled data.
Ultrasonic echo testing is a well-established non-destructive testing technique used to investigate the interior of concrete structures in civil engineering. For the reconstruction of internal features, methods similar to seismic imaging are applied. To improve the ultrasonic imaging capabilities, we investigate the potential of a newly available 3D matrix mode measurement device in combination with advanced imaging techniques.
Commonly used ultrasonic array measurement devices rely on several ultrasonic transducers coupled to act as one transducer that transmits or receives transversal ultrasound waves. Although this approach is well suited to detect elongated structures such as pipes and rebars, it has limitations if 3D embedded objects are present. Hence, the ultrasonic device MiraA1040Pro used here is designed to measure the ultrasonic wavefield on a 4 by 16 matrix of individual transducers. For testing, we used laboratory specimens with linear and spheric embedded structures first. Both linear and matrix mode measurements were conducted and analysed using the Synthetic Aperture Focusing Technique
(SAFT) which is similar to Kirchhoff migration. Second, we used a data set from Teutschenthal mine at a shotcrete specimen constructed to simulate engineered barriers tailored for nuclear waste repositories. Ultrasonic measurements were investigated as a tool for quality assurance of these structures. The specimen contains both artificial 3D artifacts as well as naturally occurring defects such as a delamination. To make use of the advanced data acquisition, focusing 3D imaging techniques are applied to further improve the imaging quality.
Generally, the reconstructed images from the 3D matrix mode data have a lower level of Signal-to-Noise-Ratio than the 2D linear mode because the source signal is weaker compared to the linear mode. Moreover, complex wave conversions of the SH-transversal wave occur that are reduced in the 2D linear scenario. However, clearer images can be achieved at non-linear features, particularly with focusing imaging methods. Thus, combining 3D data acquisition techniques with advanced imaging methods improves the success in imaging complex concrete structures. This is of particular interest for thick concrete structures in nuclear barrier systems or foundations. Additionally, we demonstrate opportunities to use well-constrained test laboratory scenarios from non-destructive testing as a practical test case for geophysical methods.
This dataset contains raw data acquired in ultrasound measurements on a reference specimen made of concrete at Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin (Germany). The internal specimen identifier is “Pk050”. The measurements were conducted using the pulse-echo method. The upper surface of the specimen was defined as measuring area. The aim of the measurements is to determine the geometrical dimensions (thickness) of the specimen “Pk050”. In addition to this, a dataset of a second specimen with identifier “Pk266” has been acquired. Pk266 has the same geometrical dimensions and concrete recipe as Pk050, but contains tendons [Reference: https://doi.org/10.7910/DVN/NUU0WZ].
The corner echo is a well-known effect in ultrasonic testing, which allows detection of surface breaking cracks with predominantly perpendicular orientation to the surface as, for example, corrosion cracks in metal pipes or shafts. This echo is formed by two planes, the surface of the crack and the surface which the crack breaks. It can also be classified as a half-skip method, since a reflection of the pulse occurs on the backwall before the reflection at the defect takes place. In combination with the diffraction from the crack tip, the corner echo also allows crack sizing. As shown in this paper, the corner reflection can be used in civil engineering for nondestructive inspection of concrete. Commercially available low frequency ultrasonic arrays with dry point contact sources generate SH transversal waves with sufficient divergence of the sound field in order to detect corner reflections. Ultrasonic line-scans and area-scans were acquired with a linear array on flat concrete specimens, and the data were reconstructed by the Synthetic aperture focusing technique. If the angles and the area of reconstruction are chosen accordingly, the corner echo reflection can be distinguished from other ultrasonic information. The corner echo can thus be used as a method for deciding whether a crack is a partial-depth crack or a full-depth crack and thus for obtaining a statement about crack depth. This paper presents corresponding experimental results obtained on concrete specimens with artificial test defects and cracks induced under controlled conditions.
The ultrasonic echo technique is frequently used in non-destructive testing (NDT) of concrete structures for thickness measurements, geometry determinations as well as localization of built-in components. To improve ultrasonic imaging of complex structures in concrete, we transferred a geophysical imaging technique, the reverse time migration (RTM), to NDT in civil engineering. In contrast to the conventionally used synthetic aperture focusing technique (SAFT) algorithms, RTM is a wavefield continuation method in time and uses the full wave equation. Thus, RTM can handle complicated wave propagations in any direction without dip limitation. In this paper, we focused on the application and evaluation of a two-dimensional (2D) elastic RTM algorithm considering compressional waves, vertically polarized shear waves, and Rayleigh waves. We tested the elastic RTM routine on synthetic ultrasonic echo data generated with a 2D concrete model consisting of several steps and circular air inclusions. As these complex structures can often be found in real-world NDT use cases, their imaging is especially important. By using elastic RTM, we were able to clearly reproduce vertical reflectors and lower edges of circular air voids inside our numerical concrete model. Such structures cannot be imaged with conventional SAFT algorithms. Furthermore, the used elastic RTM approach also yielded a better reconstruction of a horizontal reflector and upper boundaries of circular air inclusions. Our encouraging results demonstrate that elastic RTM has the potential to significantly improve the imaging of complex concrete structures and, thus, is a step forward for detailed, high-quality ultrasonic NDT in civil engineering.
Within the project SealWasteSafe, we advance construction materials and non-destructive monitoring concepts of sealing structures applied for underground disposal of nuclear waste. As these engineered barriers have high demands regarding structural integrity, an innovative alkali-activated material (AAM) that is highly suitable for the application in salt as a host rock is improved and tested on two laboratory scales. This AAM has a low heat evolution due to the reaction mechanism in comparison to common salt concretes based on Portland cement or magnesium oxychloride binders. Hence, crack formation due to thermally induced stress during the hardening process is reduced.
After successful laboratory tests with small specimens (height ~5 cm), comparably manufactured large cubic (edge length 70 cm) and cylindrical specimens (height 120 cm, diameter 40 cm) are equipped with sensing technologies to demonstrate the sensors´ technical capabilities. A comprehensive multi-sensory monitoring scheme is developed and investigated to characterize and compare the different material behaviour during the setting and hardening process of two materials: (1) the newly developed AAM-based mortars with salt aggregate, and (2) a blended Portland cement-based salt concrete as reference. The analysed parameters include temperature and humidity of the material, acoustic emissions, and strain variations recorded by fiber optic cables. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete provide an interface for the wireless readout of various sensors. In parallel to the embedded RFID sensors, conventional cabled systems to read out the temperature and humidity measurements are installed for comparison. Additionally, a detailed inspection of the two large cubic specimens after a monitoring period of more than six months has been undertaken. Active thermography and ultrasonic echo measurements are used to reveal potentially occurring inner cracks from the surface. To verify the non-invasive results, a core sample (diameter 2 cm) was extracted from each of the investigated cubic specimens and analysed in detail with X-ray computed tomography.
Furthermore, ultrasonic methods are used for quality assurance to detect obstacles, cracks, and delamination at in-situ scale sealing structures. Experimental layout and applied imaging techniques are optimised to enhance the image quality for measurements from the front side of the engineered barrier. To characterize the inside of the test sealing structure and to improve the detection of potentially existing cracks, an ultrasonic borehole probe using the phased array technique is developed. First analyses at a half-spherical specimen coincide with modelling results and prove the reliability of the directional response caused by the phased array technique of the newly constructed ultrasonic borehole probe. Overall, the project SealWasteSafe helps to characterize construction materials and improves multi-sensory monitoring concepts and ultrasonic equipment for the sake of quality assurance. Particularly for salt as a host rock, this will help to design safe sealing structures for nuclear waste disposal.
This dataset contains raw data acquired in ultrasound measurements on a reference specimen made of concrete at Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin (Germany). The internal specimen identifier is “Pk266”. The measurements were conducted using the pulse-echo method. The upper surface of the specimen was defined as measuring area. The aim of the measurements is to determine both the geometrical dimensions (thickness) and the position of tendons to the measuring area. In addition to this, a second dataset of a second specimen with identifier is existing named “Pk050” has been acquired. Pk050 has the same geometrical dimensions and concrete recipe as Pk266 recipe but does not contain tendons [Reference: https://doi.org/10.7910/DVN/9EID5D].
Engineering barrier systems are a crucial part of the safe underground disposal of radioactive waste, particularly in salt as a host rock. Sealing structures made of tailored concrete are under test at various sites in Germany. To characterise the material properties of the concrete and potentially also the bonding to the host rock as part of the necessary subsurface structures, we apply non-destructive testing making use of advanced geophysical imaging methods.
Ultrasonic investigations have been carried out at underground concrete structures in the Teutschenthal mine in Germany. Here, we show results from two distinct constructions produced in a shotcrete procedure. Our goal is to analyse the performance of ultrasonics to be used as quality assurance for sealing structures made from shotcrete. First, a ~10 m long shotcrete structure is investigated with the help of a unique Large Aperture Ultrasonic System (LAUS) allowing for depth penetration of > 9 m. We perform measurements at the front and from the side of the construction. Second, we obtain results from a 1 m thick shotcrete body containing several artificial defects (width up to 8 cm). Ultrasonic testing data were acquired using a commercial multi-static device. Additionally, a new device measuring with 3D mode instead of line mode is applied and preliminary results will be shown.
Generally, the acquired ultrasonic data are analysed by the Synthetic Aperture Focusing Technique that is commonly applied in non-destructive testing. As a result, reflectors in the analysed shotcrete structures are imaged. Individual reflections from internal features and particularly the opposite wall are identified. An unexpected delamination wider than 30 cm is clearly imaged and later verified by boreholes. Thus, the method is – in general – suitable to serve as a quality measure. However, particularly the small and deep artificial defects can hardly be identified in the resulting images. Thus, we use advanced geophysical imaging methods to further enhance the quality of the obtained images. The recorded ultrasonic energy is focused to the physically reflective origin in the analysed volume. First results clearly show that we successfully improve the image quality regarding noise level and artifacts and hence facilitate the detection of objects.
In total, we present a valuable experiment under realistic conditions for underground sealing structures made from shotcrete, where the locations of artificial reflectors are partly known. This experiment serves as a unique basis to analyse the performance of advanced analysis methods to obtain high-quality images of the structure’s interior. Hence, the developed ultrasonic testing and analysis schemes can serve as a part of quality assurance that will help to enable safe sealing structures for nuclear waste disposal.
The built infrastructure ages and requires regular inspection and, when in doubt, monitoring. To ensure that older concrete bridges showing signs of deterioration can be used safely, several innovative monitoring tools have been introduced, including but not limited to optical, fiber-optic, or acoustic emission techniques. However, there are gaps in the portfolio. A sensing technique that covers a wide range of damage scenarios and larger volumes, while still being sensitive and specific, would be beneficial.
For about 15 years, research has been conducted on ultrasonic monitoring of concrete structures that goes beyond the traditional ultrasonic pulse velocity test (PV test), mostly using a very sensitive data evaluation technique called coda wave interferometry. At BAM we have developed sensors and instrumentation specifically for this method.
We have instrumented a 70-year-old, severely damaged prestressed concrete bridge in Germany in addition to a commercial monitoring system. We have now collected data for almost 3 years. We can show that we can provide information about the stress distribution in the bridge. We have also been able to confirm that there has been no significant additional damage to the bridge since the installation.
Ultrasonic guided waves interacting with complex geometrical features are of high interest in the SHM field. For example, investigations into the extent to which a small change in defect geometry affects wave propagation have applications in Probability of Detection and defect reconstruction. These fields have to be supported by numerical tools aiming to retrieve accurate and reliable results and, thus, more realistic modeling.
Due to the short wavelengths of ultrasonic waves and the relatively large domains in which the waves propagate, fine grid resolution for the entire domain is usually not possible due to limited computational resources. One solution is to partition the domain into different subdomains and use a specific, efficient approach for each subdomain.
This contribution shows a combination of methods that aims to study these wave defect interactions in an elastic media. Firstly we introduce high-order 3D meshes that can resolve very fine geometrical details and are based on an Octree discretisation technique that employs special transition shape functions to resolve the hanging nodes that may appear due to the nature of the method. Afterward, the Octree mesh is embedded in a prismatic wave-guide based on the semi-analytical formulation of the SBFEM in 3D. To couple the different domains, we employ the mortar method, which enforces the continuity of the wave field across the internal boundaries of the domains. Examples show the power of the approach especially when it comes to parametric analysis.
Nondestructive testing of gas turbine blades is essential for their maintenance and service process which is critical to ensure both safety and efficiency of these highly stressed parts. In this presentation, a novel ultrasonic testing method is explored in order to acquire part thickness information in the turbine blade’s airfoil. In established industry processes, the measurements are mainly carried out manually and only at a few specific positions of the inspected parts. The proposed method scans the part using a robot arm guiding an ultrasonic array sensor. For ultrasonic coupling to the complex-shaped surface geometry, the inspected part and sensor are immersed into water. A two-step TFM[1, 2] (Total Focusing Method) approach is used to reconstruct the outer and inner surfaces subsequently from the ultrasonic raw data, which are acquired using the FMC[3] (Full Matrix Capture) measurement principle. For each sensor position, the location and geometry of the outer surface is first identified and then used to create an image of an area inside the material. From that image, the inner surface is reconstructed. Finally, part thickness information is deducted from merging location data of inner and outer surface. The result is a high resolution, high precision mapping of the inspected part’s wall thickness.
For structural health monitoring systems or non-destructive testing, it is crucial to study the interactions of ultrasonic-guided waves with inhomogeneities or damage in structural components. Simulation of these interactions poses a challenge.
After the wave-damage interaction, the numerical model must reproduce features like mode conversion or wave scattering. Mathematically, damages are discontinuities in a computational domain, and each wave interacts differently because of the geometrical features. We propose a quadtree-based meshing in the current contribution to capture these geometrical characteristics.
This kind of discretisation approach requires special techniques to couple cells of different sizes since, after a quadtree decomposition, the problem of so-called hanging nodes may arise. Transition elements based on high-order transfinite shape functions are used to solve this issue. The advantage is that these elements allow the correct coupling of the cells while retaining a high-order interpolation. Moreover, the reuse of the dynamic stiffness matrices can be exploited based on the similarity of the cells. This procedure makes the approach very efficient.
Examples show the scattering characteristics of different guided wave modes after interacting with inhomogeneities and discontinuities in a plate.
Temperature Compensation Strategies for Lamb Wave Inspection using Distributed Sensor Networks
(2022)
The application of temperature compensation strategies is crucial in structural health monitoring approaches based on guided waves. Actually, the varying temperature influences the performance of the inspection system inducing false alarms or missed detection, with a consequent reduction of reliability. This paper quantitatively describes a method to compensate the temperature effect, namely the optimal baseline selection (OBS), extending its application to the case of distributed sensor networks (DSN). The effect of temperature separation between baseline time-traces in OBS are investigated considering multiple couples of sensors employed in the DSN. A combined strategy that uses both OBS and frequent value warning is considered. Theoretical results are compared, using data from two several experiments, which use different frequency analysis with either predominantly A0 mode or S0 mode data or both. The focus is given on the fact that different paths are available in a sensor network and several possible combination of results are available. Nonetheless, introducing a frequent value warning it is possible to increase the efficiency of the OBS approach making use of fewer signal processing algorithms. These confirm that the performance of OBS quantitatively agrees with predictions and also demonstrate that the use of compensation strategies improve detectability of damage.
Attenuation of ultrasonic signals in concrete has the potential to carry much information about the microstructure of the material. In this work a series of concrete specimens of varying porosities and pore size distributions were internally imaged with x-ray computed tomography (CT), and then subsequently examined with throughtransmission ultrasound. The CT images were used to quantify both capillary porosity of cement paste as well as internal interfaces that are likely to produce elastic wave scattering. Ultrasound signals were represented as a diffusion process such that absorption and scattering attenuation could be isolated. As implemented, the diffusion model was a poor predictor of capillary porosity, while diffusivity was a reasonable predictor of scattering interfaces. Diffusivity was found to scale extremely well with small scale porosity, which made it a good predictor of compressive strength.
According to the NBI database, more than 21,000 in-service U.S. bridges lack sufficient structural documentation necessary for analytical load rating. Among these are a significant proportion of older prestressed concrete bridges. Given the lack of documentation on the reinforcing layout, such structures cannot be load rated analytically and are often subject to engineering judgement as the basis for rating. Otherwise, the typical approach for load rating such bridges is to conduct costly proof load testing and destructive probing together with making conservative assumptions. Therefore, any improvement to current practices will benefit DOTs and taxpayers alike. Accurately reconstructed 3D images of the girders to reflect the internal reinforcement could mitigate the need for costly, if not impractical, destructive testing and proof load testing, and help reduce dependency on conservative assumptions. This study examines a comprehensive NDE approach using ultrasonic tomography and GPR to aid in gathering structural information for load rating purposes. Different types of AASHTO and hollow core girders were tested.
The retroreflective corner echo is used, for example, in ultrasonic non-destructive testing of metals to find fatigue cracks in tubes or shafts. If the much weaker crack tip signal is additionally detected, the crack length can also be determined. A corner reflection occurs in cases of surface breaking cracks with predominantly perpendicular orientation to the surface. The intensity of the corner reflection depends on the angle of incidence and on the ultrasonic wave mode used. For the reliable detection of vertical surface breaking cracks in metals, transversal waves are commonly used, which propagate at an angle of 37° to 53° to the inspection surface. As shown in this contribution, the wide spread low frequency ultrasonic arrays with dry point contact sources available for ultrasonic testing of concrete also allow to receive corner echoes. These devices generate transversal waves in concrete structures with a large divergence of the sound field. A series of experiments was carried out with such dry point contact arrays on concrete specimens with artificial test defects and controlled induced cracks of different depths. The ultrasonic time-of-flight signals were recorded, exported and reconstructed utilising the SAFT (Synthetic Aperture Focusing Technique) algorithm. The SAFT reconstruction parameters were adjusted to visualize the corner echo indication. As will be shown, with this targeted processing, the reproducible detection of surface breaking cracks in concrete is possible. The retroreflective corner echo can thus be exploited in civil engineering for non-destructive inspection of concrete.
Integration of fiber reinforcement in high-performance cementitious materials has become widely applied in many fields of construction. One of the most investigated advantages of steel Fiber reinforced concrete (SFRC) is the deceleration of crack growth and hence its improved sustainability.
Additional benefits are associated with its structural properties, as fibers can significantly increase the ductility and the tensile strength of concrete. In some applications it is even possible to entirely replace the conventional reinforcement, leading to significant logistical and environmental benefits.
Fiber reinforcement can, however, have critical disadvantages and even hinder the Performance of concrete, since it can induce an anisotropic material behavior of the mixture if the fibers are not appropriately oriented. For a safe use of SFRC in the future, reliable non-destructive testing (NDT) methods need to be identified to assess the fibers’ orientation in hardened concrete. In this study,
ultrasonic material testing, electrical impedance testing, and X-ray computed tomography have been investigated for this purpose using specially produced samples with biased or random Fiber orientations. We demonstrate the capabilities of each of these NDT techniques for fiber orientation measurements and draw conclusions based on these results about the most promising areas for future research and development.
The ‘G¨anstorbr¨ucke’ bridge between the cities of Ulm and Neu-Ulm is one of the best-monitored bridges all over Germany. In addition to an already active bride monitoring system, we have equipped the bridge with 30 ultrasonic transducers to explore the monitoring possibilities at an in-service large-scale reinforced concrete structure with continuous active ultrasonic measurements. The monitoring system is based on the detection of small changes in the entire signal, especially the multiply scattered parts of the recording, the so-called coda. Applying Coda Wave Interferometry (CWI), subtle changes in the signal can be detected and related to changing velocities in the area between source and receiver. A comparison of the results from coda wave interferometry with the strain measurements of the permanent monitoring system shows a correlation between strain measurements and CWI results. We discuss the challenges of changing environmental conditions, pose for interpretation of the results, and highlight the advantages of embedded versus externally attached ultrasonic transducers in permanent bridge monitoring, especially when coda wave interferometry is applied.