Previous work has shown that ultrasonic monitoring using externally applied or embedded transducers and imaging methods based on coda wave interferometry are able to detect subtle changes in concrete elements. In this study, a limited number of embedded transducers has been used to monitor changes in several 12 m long two-span concrete beams subjected to point or linear loads until failure.
The ultrasonic results showed the high sensitivity to stress changes and the nonlinear character of the associated effects. However, the ultrasonic features showed a very good correlation to several conventional monitoring parameters. For higher loads (significant amount of cracking), the technique had to be modified to cope with large wave velocity variations and high decorrelation compared to the reference signal.
Using a very simple imaging procedure, the 2D stress field inside the beam has been visualized including inhomogeneities and artifact at places where cracking occurred at higher loads. The technique has the potential to be included in real time monitoring systems.
Nicht nur die Qualitätssicherung von Bauteilen wird immer wichtiger und muss immer höheren Anforderungen entsprechen, sondern auch die dafür verwendete Prüfeinrichtung und die Sensorik. Für die Qualitätssicherung von Ultraschall-Prüfköpfen mit Luftankopplung bestand die bisherige Lösung darin, baugleiche Wandler als Aktuatoren (Referenzsender) einzusetzen.
Für eine Weiterentwicklung der Wandler ist eine akustische Quelle wünschenswert, die eine weit größere Bandbreite mit flachem Frequenzgang aufweist, als die zu untersuchenden Prüfköpfe. Hier bieten sich thermoakustische Wandler an, die keine ausgeprägten Resonanzen haben und über eine hohe Bandbreite verfügen (min. 10 kHz bis 1 MHz). Diese wurden von der BAM in Berlin entwickelt und decken den Frequenzbereich von typischen Luftultraschall-Prüfköpfen vollständig ab.
Der Vortag beschreibt die Besonderheiten der Ansteuerung dieser Wandler, die einen Innenwiderstand von ca. 7 Ohm besitzen und eine Pulsleistung von etwa 10 kW benötigen.
Ferner werden erste Ergebnisse der Charakterisierung von unterschiedlichen piezokeramischen Prüfköpfen im Frequenzbereich von 50 kHz bis 500 kHz präsentiert.
Beispielhaft zeigte ein Prüfkopf mit mehreren Anpassschichten lokale Frequenzunterschiede im Schallfeld.
Monitoring of Concrete with Embedded Ultrasound Sensors, Coda Waves and a Novel Measurement Device
(2020)
Using embedded ultrasound (US) sensors in civil engineering structures and Coda Wave Interferometry (CWI), DFG research group CoDA aims for developing methods of concrete damage assessment by combination of Micro and macro scale simulations and experiments. BAMs goal within the project is the provision of small and durable measurement equipment on the one hand, and the investigation of damage sensitive parameters and development of an imaging algorithm on the other hand. In this study we focus on the development of the measurement system and the influence of temperature variations on the measurements.
Motivation:
• Air-coupled ultrasound (AC-US) enables faster measurements in non-destructive testing for civil engineering
• Current state of the art: piezo and capacitive transducers are mostly used for AC US
• Currently >99.9% sound intensity loss due to impedance mismatches
Innovation:
• Fluidic transducers generate US (30-60 kHz) by rapid switching of a supersonic jet
• Fluidic transducers rely on external components such as solenoid valves and tubing
--> How do repetition time and tube length influence the signal?
Monitoring of reinforced concrete structures to ensure their stability and increase their service-life is a crucial element of a modern infrastructural concept. With classical methods of non-destructive testing and inspection, repeated measurements under comparable conditions are difficult to conduct. Therefore, DFG research unit FOR 2825 CoDA researches the assessment of concrete damage using ultrasound coda wave interferometry and embedded sensors. Embedding the sensors into the monitoring target reduces human and non-human factors influencing repeatability. Using Coda Wave Interferometry (CWI), small velocity changes in the material can be detected by comparison of repeated measurements. The technique is sensitive to damaging changes like cracking as well as to reversible influences like material temperature. The understanding of these different influences on the signal is crucial for the analysis of long-term monitoring data to make an educated assessment of the structure and its integrity. With several laboratory experiments in a climate chamber and a long-term experiment recording an annual cycle in a large model on an outdoor test site in Horstwalde close to Berlin, we try to understand the influence of temperature on the CWI results. The results show that the velocity change calculated by CWI does closely follow the trend of concrete temperature. After one year of data recording with the large model being exposed to environmental variations only, the calculated velocity change resembles the annual temperature curve. The data shows a linear dependency between velocity and temperature change in a range of -0.03 percent per °K to -0.06 percent per °K - regardless of specimen size. An approach to remove temperature influence from the yearly cycle recorded in the large-scale experiment using this linear relation is unable to remove high-frequency variations - especially daily influences. Low-pass filtering the data can eliminate these variations while preserving permanent shifts caused by damages. Although we have shown that the influence of temperature on long term monitoring can be removed to a significant extent, there is still an influence of environmental changes remaining in the data. Possible nonlinear effects and influences not related to temperature need to be investigated in the future.
According to the NBI database, more than 21,000 in-service U.S. bridges lack sufficient structural documentation necessary for analytical load rating. Among these are a significant proportion of older prestressed concrete bridges. Given the lack of documentation on the reinforcing layout, such structures cannot be load rated analytically and are often subject to engineering judgement as the basis for rating. Otherwise, the typical approach for load rating such bridges is to conduct costly proof load testing and destructive probing together with making conservative assumptions. Therefore, any improvement to current practices will benefit DOTs and taxpayers alike. Accurately reconstructed 3D images of the girders to reflect the internal reinforcement could mitigate the need for costly, if not impractical, destructive testing and proof load testing, and help reduce dependency on conservative assumptions. This study examines a comprehensive NDE approach using ultrasonic tomography and GPR to aid in gathering structural information for load rating purposes. Different types of AASHTO and hollow core girders were tested.
Within a DFG-funded research group, we investigate the possibility of concrete damage assessment with coda waves. Coda wave interferometry (CWI) can be a valuable asset to structural health monitoring (SHM) as we can detect small signal changes and quantify them with the calculation of relative velocity changes. By equipping an in-service road bridge with more than 24 embedded ultrasonic transducers, we want to analyze how methods developed within the research group perform in an uncontrollable environment. We evaluate individual source-receiver combinations for detection of temporal changes as well as the entire installed sensor array to create maps of material change comparing two distinct states of the bridge.
Engineering barrier systems are a crucial part of the safe underground disposal of radioactive waste, particularly in salt as a host rock. Sealing structures made of tailored concrete are under test at various sites in Germany. To characterise the material properties of the concrete and potentially also the bonding to the host rock as part of the necessary subsurface structures, we apply non-destructive testing making use of advanced geophysical imaging methods.
Ultrasonic investigations have been carried out at underground concrete structures in the Teutschenthal mine in Germany. Here, we show results from two distinct constructions produced in a shotcrete procedure. Our goal is to analyse the performance of ultrasonics to be used as quality assurance for sealing structures made from shotcrete. First, a ~10 m long shotcrete structure is investigated with the help of a unique Large Aperture Ultrasonic System (LAUS) allowing for depth penetration of > 9 m. We perform measurements at the front and from the side of the construction. Second, we obtain results from a 1 m thick shotcrete body containing several artificial defects (width up to 8 cm). Ultrasonic testing data were acquired using a commercial multi-static device. Additionally, a new device measuring with 3D mode instead of line mode is applied and preliminary results will be shown.
Generally, the acquired ultrasonic data are analysed by the Synthetic Aperture Focusing Technique that is commonly applied in non-destructive testing. As a result, reflectors in the analysed shotcrete structures are imaged. Individual reflections from internal features and particularly the opposite wall are identified. An unexpected delamination wider than 30 cm is clearly imaged and later verified by boreholes. Thus, the method is – in general – suitable to serve as a quality measure. However, particularly the small and deep artificial defects can hardly be identified in the resulting images. Thus, we use advanced geophysical imaging methods to further enhance the quality of the obtained images. The recorded ultrasonic energy is focused to the physically reflective origin in the analysed volume. First results clearly show that we successfully improve the image quality regarding noise level and artifacts and hence facilitate the detection of objects.
In total, we present a valuable experiment under realistic conditions for underground sealing structures made from shotcrete, where the locations of artificial reflectors are partly known. This experiment serves as a unique basis to analyse the performance of advanced analysis methods to obtain high-quality images of the structure’s interior. Hence, the developed ultrasonic testing and analysis schemes can serve as a part of quality assurance that will help to enable safe sealing structures for nuclear waste disposal.