7.2 Ingenieurbau
Filtern
Erscheinungsjahr
- 2018 (8) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (8) (entfernen)
Referierte Publikation
- nein (8) (entfernen)
Schlagworte
- Repair (2)
- Acoustic emission testing (1)
- Amplitude-charge weight laws (1)
- Amplitude-distance laws (1)
- Analysis of variance (1)
- Big Data (1)
- Box-Behnken (1)
- Compressive cyclic loading (1)
- Compressive strength (1)
- Conductor (1)
Organisationseinheit der BAM
Grouting is a universal repair and strengthening technique, which is constantly used for structural remediation of concrete components, trenches, mine subsidence, dam joints, restoration of masonry structures, and geological stabilizations. Having an extremely small particle size of only few microns, ultrafine cements are ideal for grouting applications due to their superior permeability and compressive strength properties of the hardened cement paste compared to that of the less-expensive, but coarser ordinary Portland cements. Supplementary cementitious materials (SCMs) are often used to replace ultrafine cement in order to modify certain properties and to reduce costs. The aim of this experimental study is to investigate the effect of three supplementary materials: microsilica (MS), fly ash (FA), and metakaolin (MK) on the workability, and mechanical properties of an ultrafine cement based grout with a constant water-binder ratio and constant superplasticizer content. Maximum percentages of replacement with ultrafine cement were 6% by volume of cement for MS and 16% for FA, and MK. In general, results suggest that the workability is improved by addition of FA, whereas is reduced, when modified with MS and MK. The compressive strength of grout after cement replacement remains comparable to that of pure cement grout. However, there is a tendency of the MS to positively affect the compressive strength opposite to FA, whereas flexural strength is positively affected by FA. Based on the results, it is evident that grouts with Hägerman cone flow more than 500 mm and compressive strength of more than 90 MPa after 28 days can be produced.
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.
Explosion-induced ground vibrations have been measured at several places. Results about the wave propagation are shown in this contribution. The particle velocities of the soil have been measured at up to 1000 m distance from the explosion and are presented as time records (seismograms) and one-third octave band spectra (transfer functions). The results are compared with the results of hammer impacts. The seismograms clearly show different wave types, compressional waves of the air, the water and the soil, and the Rayleigh wave. The hammer impacts yield good results up to 100 m and incorporate higher frequencies at about 50 Hz, whereas the explosion results in a ground vibration with frequencies around 10 Hz and a longer range of influence. Explosion and hammer excitations are evaluated for the wave velocities of the soil by using the wavenumber and the spatial auto-correlation method. The attenuation of the ground vibration amplitudes A with distance r can well be presented by a power law A ~ r -q. This type of amplitude-distance law and the corresponding power q > 1 are substantiated in the contribution. The influence of the charge weight W is evaluated as an additional power law A ~ W -p for each measuring site. The power is found quite similarly around q 0.6 as all sites have a medium soft soil such as sand and clay. The obtained amplitude-charge-distance law can be used to predict the explosion-induced ground and building vibrations at other sites.
Within the presented research project, experimental and numerical investigations were performed to develop a thin-shelled, modular, mobile element system made of a micro-reinforced ultra-high-performance ductile concrete (DUCON®). Material parameters were experimentally determined to adapt the material model within the numerical analysis applying the Drucker-Prager relationship. Afterwards, for validation of the numerical models, quasi-static and high-velocity impact tests were performed on plate-like structures. Finally, a suitable geometry of transportable barrier elements will be designed, which provides a maximum of resistance against impact by a minimum of weight and a maximum of mobility.
The worldwide spread of windfarms brings new challenges, especially for concrete structures as a part of towers, connecting joints and foundations of wind turbines. High-cyclic loadings in such structures lead to a high relevance of the subject of fatigue. A proper assessment of the fatigue strength of concrete demands therefore a basis of reliable experimental data and the development of standardized testing methods. This article presents first results of an ongoing research program of BAM (Bundesanstalt für Materialforschung und -prüfung) which is a part of a joint project (WinConFat) funded by the German Federal Ministry for Economic Affairs and Energy. The subproject investigates the effects of size and slenderness of the specimens on the fatigue behaviour of high strength concrete at different stress levels. Not only the fatigue strength, but also the fatigue process itself is monitored by means of several measurement methods. Strain measurements are used to calculate the load dependent elastic modulus in the fatigue hysteresis as indicators for fatigue development. Furthermore, the application of non-destructive methods like acoustic emission analysis and ultrasonic measurement in laboratory tests gives a deeper insight into damage processes under cyclic loading. The results shall be used to improve design rules for concrete members under fatigue load and to develop or improve non-destructive techniques for in-service structural health monitoring.
Mit der Errichtung und der Inbetriebnahme des Windpark alpha ventus wurden umfangreiche Messungen an den Tragstrukturen und den Umgebungsparametern durchgeführt. Im Projekt Gigawind life wurde im TP1 ein Datenmanagementsystem zur kontinuierlichen und periodisch fortgeführten Datenauswertung für große Datenbestände (Big Data) entworfen und realisiert. Anhand von Performanceuntersuchungen konnte eine Verkürzung der Rechenzeit um den Faktor 10 in einem Rechencluster erreicht werden. Unter Anwendung einer Datenpipeline nach dem Publish/Subscribe Prinzip wird eine skalierbare Datenschnittstelle für Monitoringdaten vorgeschlagen.
In recent years, several high temperature low sag conductors (HTLS) have been developed and are now commercially available. Very few utilities have long-term experience with all the technologies. Moreover, most of the operational experience is at low temperatures. An independent testing program at maximum operational temperatures comparing most of the available technologies would provide useful guidance to utilities considering using such conductors.
This paper describes the approach and results of an international research project assessing the long-term reliability of a wide range of commercially available high temperature conductor systems. Each system was exposed to 4,400 hours of simultaneous mechanical and electrical stresses. A set of standard mechanical and electrical tests were carried out to determine any changes. A conventional ACSR conductor was also tested and provided a validation that the testing program was realistic.
The majority of the conductor systems performed satisfactorily. However the ACSS system joint resistance and the grease on the TACSR performed poorly.
The response of many geotechnical systems, whose structural behavior depends on shearing effect, is closely related to soil structure interaction phenomenon. Experimentally it is found that the localisation of these effect happens at a narrow soil layer next to the structure. Numerically, this behavior can be modelled through inter-face elements and adequate constitutive models. In this work, a constitutive model in the framework of Gen-eralized Plasticity for sandy soils has been chosen to be adapted for the interface zone. From the direct shear experiments a sandy soil at loose and dense states under different normal pressures is considered. The adapted constitutive model is able to reproduce contraction and dilatation of the soil according to its relative density and it shows a good agreement with the experimental data.