Paper des Monats
- ja (4)
A prediction software has been developed by BAM. The following topics have still be solved. A realistic irregularity spectrum can be derived from axle-box measurements. It agrees wel with the spectrum used for the high-speed 2 project in the United Kingdom. In addition, the scattering of axle pulses should be included. This mid-frequency component can also be found in the HS2 procedure. Finally, the reduction in case of a tunnel line compared to a surface line should be included. Some measurement results of BAM, HS2 and other institutes show a certain mid-frequency reduction. This is due to the load distribution of the tunnel which yields softer axle pulses and the scattered axle impulses are reduced.
The train passages over intact or damaged slab tracks on different soils have been calculated by the finite-element boundary-element or the wavenumber-domain method. The influence of track and soil parameters on the distribution of the track displacements and the soil forces has been analysed. The measured and calculated displacement time histories of train passages could be used to identify track damages such as lose sleepers or a lose track plate. The time histories and spectra of the soil forces can explain the measured ground vibration reduction of slab tracks. The calculated displacement and force distributions of slab tracks on continuous soils do not fulfil the Winkler hypothesis and Winkler models should not be used for track analysis.
Severe mechanical fatigue conditions for worldwide proliferating windfarms are a Major challenge for high-performance concrete in towers, connecting joints and foundations of wind turbines. High-performance concrete offers potential for the application in offshore windfarms, not only regarding its good mechanical, but also chemical resistivity due to low diffusivity in the highly densified microstructure. For a more reliable fatigue assessment, monitoring based on nondestructive testing can be a valuable complement to design rules. Both approaches demand reliable experimental data, information about scalability and the development of standardized testing methods. This article presents results of an ongoing research program of BAM (Bundesanstalt für Materialforschung und -prüfung), which is a part of a joint national project (WinConFat) funded by the German Federal Ministry for Economic Affairs and Energy. The subproject implemented by BAM examines the fatigue behavior in dependence of size and slenderness for varying concrete strength at different stress levels. Besides fatigue strength, nondestructive testing is carried out additionally.
Methods used are strain measurement and ultrasonic testing. The change of strain, stiffness and ultrasonic pulse velocity in the fatigue process is discussed. Results disclose a deeper insight into the damage process under cyclic loading of high-performance concrete and contribute to improve nondestructive monitoring.
Severe mechanical fatigue conditions for worldwide proliferating windfarms are a Major challenge for high-performance concrete in towers, connecting joints and foundations of wind turbines. High-performance concrete offers potential for the application in offshore windfarms, not only regarding its good mechanical, but also chemical resistivity due to low diffusivity in the highly densified microstructure. For a more reliable fatigue assessment, monitoring based on nondestructive testing can be a valuable complement to design rules. Both approaches demand reliable experimental data, information about scalability and the development of standardized testing methods. This article presents results of an ongoing research program of BAM (Bundesanstalt für Materialforschung und -prüfung), which is a part of a joint national project (WinConFat) funded by the German Federal Ministry for Economic Affairs and Energy. The subproject implemented by BAM examines the fatigue behavior in dependence of size and slenderness for varying concrete strength at different stress levels. Besides fatigue strength, nondestructive testing is carried out additionally.
Methods used are strain measurement and ultrasonic testing. The change of strain, stiffness and ultrasonic pulse velocity in the fatigue process is discussed. Results disclose a deeper insight into the damage process under cyclic loading of high-performance concrete and contribute to improve nondestructive monitoring.
The increasing use of renewable energies leads to a constant search for optimised foundation concepts aiming to reduce the costs for offshore wind turbines. In an ongoing research project, we are developing a design approach for typical offshore driven piles based on the application of injections by compaction grouting directly at the pile shaft. Compaction grouting as a ground improvement technique has been used widely as a countermeasure against liquefaction, settlement and low bearing capacity of soil under new or already existing structures. It is performed by forcing highly viscous grout into the soil to displace and compact the surrounding soil without fracturing or penetrating it. Regarding this injection method, this paper gives a brief overview about general aspects such as appropriate soil characteristics and grouting parameters, grouting equipment and fields of application particularly in the offshore sector. This indicates the ability of our optimisation concept to provide an economic alternative to larger pile dimensions and a retrofitting technique, which is available during the entire lifetime of the foundation and can be deployed only in case of necessity (e.g. excessive deformations or insufficient structural stiffness after an extreme load event).
Besides the material feasibility and the constructive realisation of this improvement measure, the development of a corresponding verification concept is crucial in order to ensure the safety and durability of the retrofitted offshore piles. Here we will examine various verification concepts with their respective limitations in the framework of the limit state design. Furthermore, we will present the experimental findings from field tests in sand indicating the advantages of several local injections by compaction grouting for the enhancement of the load bearing behaviour of pile foundations. The test results were also used to validate a numerical model, developed with the finite element program PLAXIS, aiming to predict the expected bearing capacity for different injection scenarios (e.g. grout volume, location of injection points) along a pile shaft.
The aim of an ongoing research project is to develop a design approach for typical offshore driven piles (e.g. Jacket piles) based on the application of injections by compaction grouting directly at the pile shaft. The paper aims to present the results of laboratory and in-situ tests, which reveal the efficiency and the promising potential of the optimised foundation concept for a more economic dimensioning of pile foundations and to increase their bearing capacity in non-cohesive soil at any moment after installation.
Measurements of ground and track vibrations have been performed at a high-speed line in northern Germany. Impacts on the track and the ground, and passages of different trains with different speeds on different tracks have been measured. Transfer functions of the soil are presented and approximated by theoretical soil models. By using these transfer functions, the measured ground vibration between 2 to 64 m distance from the track can be transformed into a load spectrum which can be used for predictions at other sites. The method is compared to the soil-dependent method of an emission spectrum at a certain distance (8 m for example). The influence of train type, speed and track type is discussed on the base of the different emission quantities and the original measurements. The strong influence of the track, ballast track and slab track, is analysed by a theoretical model in wavenumber domain. The response of the track to the passage of the static load is reduced by the stiffness of the slab, the deformation of the track as well as the impulse acting on the soil. Usually, the impulse on the soil should result in a slow quasi-static movement of the soil, slower at further distances. In a heterogeneous soil, however, the impulses from the static loads scatter and keep parts of the higher impulse frequency band. In this case the reduced impulse spectra of the slab track will yield reduced ground vibration in a certain frequency band. Additional (BAM and international) measurements will be used to discuss this and possible other explanations for the different ground vibration differences.
In recent years, several high temperature low sag conductors (HTLS) have been developed and are now commercially available. Very few utilities have long-term experience with all the technologies. Moreover, most of the operational experience is at low temperatures. An independent testing program at maximum operational temperatures comparing most of the available technologies would provide useful guidance to utilities considering using such conductors.
This paper describes the approach and results of an international research project assessing the long-term reliability of a wide range of commercially available high temperature conductor systems. Each system was exposed to 4,400 hours of simultaneous mechanical and electrical stresses. A set of standard mechanical and electrical tests were carried out to determine any changes. A conventional ACSR conductor was also tested and provided a validation that the testing program was realistic.
The majority of the conductor systems performed satisfactorily. However the ACSS system joint resistance and the grease on the TACSR performed poorly.
Global energy consumption will increase in the future necessitating both fossil fuels and renewable energy choices - especially wind energy. Such high energy demand requires installation of offshore energy structures, rigs, platforms and towers, which are susceptible to adverse environmental conditions along with maintenances. Due to their large size and remote locations, cylindrical grouted joints are often adopted between substructure and foundation in these offshore platforms and wind structures such as monopiles. However, these connections are composite structures with exterior sleeve, interior pile and infill mortar. Degradation and settlements were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites were proven difficult to obtain ideal load bearing capacity. In-situ loading conditions were also found to be affecting the failure mechanism inside such connections. This study aims at characterizing the nature of cracks generated in these grouted connections under both static and cyclic loading. Scaled grouted joints were manufactured using a novel reusable mold, and connections were loaded to failure to visualize the main failure patterns. An assessment between failure under these two types of load is drawn along with comparison to previously available literature.
Global energy consumption will increase in the future necessitating both fossil fuels and renewable energy choices - especially wind energy. Such high energy demand requires installation of offshore energy structures, rigs, platforms and towers, which are susceptible to adverse environmental conditions along with maintenances. Due to their large size and remote locations, cylindrical grouted joints are often adopted between substructure and foundation in these offshore platforms and wind structures such as monopiles. However, these connections are composite structures with exterior sleeve, interior pile and infill mortar. Degradation and settlements were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites were proven difficult to obtain ideal load bearing capacity. In-situ loading conditions were also found to be affecting the failure mechanism inside such connections. This study aims at characterizing the nature of cracks generated in these grouted connections under both static and cyclic loading. Scaled grouted joints were manufactured using a novel reusable mold, and connections were loaded to failure to visualize the main failure patterns. An assessment between failure under these two types of load is drawn along with comparison to previously available literature.
At present, to produce renewable energy offshore wind farms play an important role. The available space combined with the more valuable wind conditions make offshore locations very attractive for wind powered energy production. In Europe a significant number of offshore wind farms already exist, especially in the North and Baltic Sea. In future this trend will continue, and further offshore wind farms will be built. The majority of offshore wind turbines are mounted on steel foundation structures. Due to the high-cyclic loading by wind and waves fatigue stress plays a substantial role regarding structural safety.
Besides the consideration of fatigue within the design process, to monitor existing steel structures for potential fatigue cracks during their life time is a major topic and a challenge.
For the structures of the offshore wind turbines are large and partially under water effective reliable methods for the detection of fatigue cracks are required.
This contribution presents investigations on different crack detection methods applied at high-cycle fatigue tests on small-scale welded steel samples as well as on large-scale welded steel components. The tests were conducted at the BAM laboratories. For crack detection mainly three different methods were used and compared. The first method regards to the measurement of strain by conventionally strain gauges. Secondly, the crack luminescence was used as a new and effective optical method for surface monitoring. And finally, crack detection by pressure differentials of the inner and outer section of tubular steel elements was investigated. A comparison study will emphasize the advantages and disadvantages of the different methods and show which of the described methods is potentially more suitable for an application on real offshore wind structures.
At present, to produce renewable energy offshore wind farms play an important role. The available space combined with the more valuable wind conditions make offshore locations very attractive for wind powered energy production. In Europe a significant number of offshore wind farms already exist, especially in the North and Baltic Sea. In future this trend will continue, and further offshore wind farms will be built. The majority of offshore wind turbines are mounted on steel foundation structures. Due to the high-cyclic loading by wind and waves fatigue stress plays a substantial role regarding structural safety.
Besides the consideration of fatigue within the design process, to monitor existing steel structures for potential fatigue cracks during their life time is a major topic and a challenge.
For the structures of the offshore wind turbines are large and partially under water effective reliable methods for the detection of fatigue cracks are required.
This contribution presents investigations on different crack detection methods applied at high-cycle fatigue tests on small-scale welded steel samples as well as on large-scale welded steel components. The tests were conducted at the BAM laboratories. For crack detection mainly three different methods were used and compared. The first method regards to the measurement of strain by conventionally strain gauges. Secondly, the crack luminescence was used as a new and effective optical method for surface monitoring. And finally, crack detection by pressure differentials of the inner and outer section of tubular steel elements was investigated. A comparison study will emphasize the advantages and disadvantages of the different methods and show which of the described methods is potentially more suitable for an application on real offshore wind structures.
A combined finite-element boundary-element method for the dynamic interaction of the soil with flexible structures such as single piles or complete wind energy towers has been developed. Flexible piles in different soils are analysed in frequency domain. The different parameters such as the stiffness of the soil, the bending stiffness and the radius of the hollow pile are analysed for their influence on the complex compliances. The results have been determined as specific power laws which are different for the different load cases (horizontal, rocking, coupling) and for the different soil models (Winkler, continuum with constant, root-parabolic and proportional-linear stiffness variation). The strongest influence of the soil stiffness can be found for the homogeneous soil and the horizontal component. Winkler soils have a weaker influence than the corresponding continuous soils. An offshore wind energy tower has been modeled and calculated for wind and wave loads.
Current standards like ISO 14837-32:2015 and DIN EN 1998-1/NA:2021 as well as prEN 1997-2:2022 allow for using correlations between the results of in-situ soil penetration tests and shear wave velocity (or shear modulus) to determine soil properties to be used in dynamic analyses. While the ISO and prEN standards even provide some recommendations on specific correlations to be used, the DIN standard does not. Due to the statistical nature of such correlations their general applicability has to be verified. We collected data sets from test sites from Germany as well as New Zealand at which cone penetration tests (CPT) as well as seismic site investigation methods were conducted. These sites comprise sandy soils as well as clayey soils, mixed soils as well as glacial soils. We compare the results of several correlations between CPT results and shear wave velocity. The accuracy of such correlations is assessed with respect to the accuracy of seismic in-situ tests. It turns out that for clean sands such correlations between CPT and Vs have a similar order of variability as seismic in-situ tests conducted at the same site. The higher the fines portion of the soil, the higher the variability of the statistical correlations, and consequently the less the general applicability. For glacial soils and other special soil types usage of statistical correlations to determine dynamic soil properties is not recommended.
The mechanical properties of unstabilised earthen building materials are distinctively influenced by changes in material moisture content. However, this moisture-dependency often remains unconsidered in the calculation of the load-bearing capacity of earth constructions. This paper aims to derive a convenient way to sufficiently consider the impact of different material moisture contents on the mechanical properties of unstabilised earth masonry. Therefore, the influence of relative humidity and temperature on the strength and deformation characteristics of unstabilised earth blocks, earth mortar and earth masonry is evaluated by conducting compression tests under various climate conditions. The results show that the compressive strength and the modulus of elasticity are linearly correlated with the relative humidity, whereas changes in temperature at constant relative humidity have no significant influence. To account the distinct moisture-dependency, a general applicable modification factor for unstabilised earthen materials is provided, which enables the adjustment of the compressive strength and the modulus of elasticity in dependency of arbitrary hygroscopic material moisture contents.