7.2 Ingenieurbau
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (82) (entfernen)
Sprache
- Englisch (66)
- Deutsch (15)
- Mehrsprachig (1)
Schlagworte
- Ground vibration (6)
- Structural health monitoring (6)
- Fatigue (5)
- Structural Health Monitoring (5)
- Model interpolation (4)
- Vibration measurements (4)
- Building vibration (3)
- Damage localization (3)
- Hammer impact (3)
- Impact (3)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (82)
- 7.2 Ingenieurbau (82)
- 7.4 Baustofftechnologie (8)
- 8 Zerstörungsfreie Prüfung (7)
- 7.1 Baustoffe (4)
- 3 Gefahrgutumschließungen; Energiespeicher (2)
- 3.3 Sicherheit von Transportbehältern (2)
- 7.0 Abteilungsleitung und andere (2)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 8.5 Röntgenbildgebung (2)
Die Bemessung von tragendem Lehmmauerwerk erfolgt in Deutschland auf Basis der Lehmbau Regeln. Das dort verankerte Nachweisverfahren beruht auf einem globalen Sicherheitskonzept, welches aus zuverlässigkeitstheoretischer Sicht nicht mehr dem Stand der Technik entspricht. Auf Grund dessen wird das Bemessungskonzept für Lehmmauerwerk vom Deutschen Institut für Bautechnik (DIBt) voraussichtlich 2023 außer Kraft gesetzt. Ein statischer Nachweis von tragenden Lehmbauten wäre in Deutschland dann ausschließlich mit einer Zustimmung im Einzelfall (ZiE) oder vorhabenbezogener Bauartgenehmigung (vBg) möglich. Beides ist mit erheblichem Mehraufwand und höheren Kosten verbunden, was für den Lehmmauerwerksbau einen entscheidenden Nachteil im Vergleich zum konventionellen Mauerwerksbau darstellt. Um eine unkomplizierte Praxisanwendung von Lehmmauerwerk zu ermöglichen, werden innerhalb eines Forschungsvorhabens, welches von der Bundesanstalt für Materialforschung und -prüfung (BAM), dem Institut für Massivbau der Technischen Universität Darmstadt sowie dem Ingenieurbüro ZRS durchgeführt wird, auf Basis der Produktnormen für Lehmsteine und Lehmmauermörtel Grundlagen für ein aktualisiertes Bemessungskonzept entwickelt. Im Rahmen des Projekts wird ebenfalls untersucht, inwiefern die Bemessungsregeln nach den vereinfachten Berechnungsmethoden für unbewehrtes Mauerwerk gemäß DIN EN 1996-3 / NA auf den Lehmmauerwerksbau übertragbar sind. Falls eine Anwendung des normativen Nachweisverfahrens bei Lehmmauerwerk möglich ist, wäre zukünftig eine Aufnahme von Lehmsteinen und Lehmmauermörtel in den nationalen Anhang des Eurocode 6 denkbar, was eine bedeutsame Erweiterung des Anwendungsbereichs von Lehmmauerwerk zur Folge hätte.
Diverse wissenschaftliche Untersuchungen konnten zeigen, dass bemessungsrelevante Festigkeits- und Verformungseigenschaften von Lehmmauerwerksbaustoffen stark von der vorherrschenden Materialfeuchte abhängen, welche im hygroskopischen Wassergehaltsbereich im Wesentlichen von der relativen Luftfeuchte (RLF) bestimmt wird. Auch die Zwischenergebnisse des laufenden Forschungsvorhabens zur Entwicklung eines Bemessungskonzepts für Lehmmauerwerk ergaben eine deutlich erkennbare Abhängigkeit zwischen der Materialfeuchte und den relevanten Festigkeits- und Verformungseigenschaften. Eine detaillierte Kenntnis des feuchteabhängigen Materialverhaltens von Lehmsteinen, -mörtel und -mauerwerk ist zwingend erforderlich, um ein konsistentes und zuverlässiges Bemessungskonzept für Lehmmauerwerk zu entwickeln. Im Rahmen des laufenden Forschungsprojektes werden deshalb umfangreiche Versuche zum Drucktragverhalten von Lehmsteinen und -mörtel sowie Lehmmauerwerk nach Konditionierung bei unterschiedlichen RLF durchgeführt und analysiert. Weiterhin werden auf Basis der experimentellen Ergebnisse numerische Modelle kalibriert, welche die detaillierte Analyse der Biegedrucktragfähigkeit von Lehmmauerwerk ermöglichen.
In diesem Beitrag werden zunächst die bisherigen Zwischenergebnisse bezüglich der experimentell ermittelten feuchteabhängigen Materialkennwerte von Lehmsteinen, -mörtel und -mauerwerk dargelegt. Darauf aufbauend werden numerische Untersuchungen zur Bestimmung der Systemtragfähigkeit von Lehmmauerwerk unter Feuchteeinflusses durchgeführt und erläutert.
Der Beitrag berichtet von einer aufwändigen Messkampagne vor Ort, mit der die Emissionen direkt an einer Rohzementmühle, die Transmissionen im Baugrund und die Immissionen in benachbarten Bebauungen genauer untersucht wurden. Im Ergebnis der ausgewerteten Messungen sowie strukturdynamischer Berechnungen zeigte sich, dass der Baugrund zwar aus statischer Sicht sehr gut tragfähig, aber dynamisch als eher ungünstig zu beurteilen ist. Weiterhin wurde festgestellt, dass in dynamischer Hinsicht ein vorgenommener Bodenaustausch tendenziell eine Verschlechterung der Aufstellbedingungen darstellte. Für das betroffene Bürogebäude konnte nachgewiesen werden, dass durch den Betrieb der Zementmühle die Anregung der Deckeneigenfrequenzen zu deutlich spürbaren Resonanzschwingungen führte. Aufgrund der tieffrequenten Anregung durch den Mühlenbetrieb sind Maßnahmen zur Minderung der Schwingungsemissionen generell und insbesondere nach erfolgter Aufstellung der Mühle schwer bzw. gar nicht zu realisieren. Im Beitrag wird daher darauf eingegangen, auf welche Aspekte bei der Planung zur Aufstellung derart großer Mühlen zwingend zu achten ist.
A study on building vibrations has been performed by finite element calculations. Family houses, multi-storey residential buildings, office buildings and office towers have been modelled in detail. The frequency-dependent response due to a free-field excitation has been evaluated for walls, columns and floors. The ratio of building amplitudes to free-field amplitudes starts with uB/u0 = 1 at zero frequency and is usually lower than 1 at 50 Hz, the end of the frequency range considered here. In between, amplifications occur due to several reasons. There are „soil resonances“ where the whole building is vibrating on the compliant soil, “column resonances” where the upper storeys are vibrating on the compliant columns, and the “floor resonances” where the floors are vibrating excited by their supports. Results are presented for all building types, but a special focus is set on office buildings. A parameter study shows the influence of the stiffness of the soil, the number of storeys, and the width of the building. It has been found that the “soil resonance” is strongly modified by the low-frequency floor resonances for the normal office building. The main resonance of a twenty-storey office tower is determined equally by the “soil mode” and the “column mode”. It is an important observation for these office buildings that the resonances can differ for different parts of the building such as the centre, the edge, the corner, and the core of the building. This leads to non-uniform vibration modes across the building, which look like another type of “floor resonance” and which have been observed in several real building projects. Experimental results will be shown which can confirm the calculated phenomena.
In case one wants to predict or design the bearing capacity of a foundation pile and there are no possibilities to perform an in-situ test, such as a Cone Penetration Test, the pile bearing capacity is in most cases estimated with analytical formulas. The most known and used method is the Meyerhof method published some decades ago. There are also other design methods such as derived from a certain failure mechanism around the pile tip, which is, in most cases, wedge failure mechanism. This failure mechanism was originally developed for a shallow (infinite) strip foundation, though. Therefore, it represents a plane failure mechanism.
Numerical simulations on loaded foundation piles performed with the Plaxis software Show however, that the failure mechanism of a foundation pile represents a far more complex threedimensional failure mechanism around the pile tip.
In addition, the existing analytical methods for foundation piles are based on the vertical stresses in the soil, as if the failure mechanism is the same as of a shallow foundation. Numerical simulations, performed in Plaxis show that, not the vertical, but the horizontal stresses, play an important role on the pile bearing capacity. Plaxis represents the stresses in the soil by using the procedure. So, different horizontal soil stresses are obtained for different values of the lateral earth pressure coefficient. The results show that the pile tip bearing capacity depends strongly on the horizontal stresses in the soil, but only for. The same results were observed by using a Material Point Method (MPM). Consequently, the analytical methods should estimate the pile bearing.
Superplasticizer and Shrinkage Reducing Admixture Dosages for Microfine Cement in Grout Systems
(2019)
Grouts have numerous applications including crack repair as maintenance in construction industries. Microfine cements are intensively used for high strength mortar and grout products. They are ideal for injection grouting in structural repair. Such grouts should have suitable rheological properties to be injectable, especially those used in repair and rehabilitation. The use of superplasticizers (SP) in these products is thus becoming increasingly crucial to achieve favorable workability and viscosity properties. A difficulty in such grouts is the plastic shrinkage due to finer particles used. It is thus necessary to determine optimum SP and shrinkage reducing admixture (SRA) dosages for a microfine cement based grout. In this study, a saturation dosage was decided from two Polycarboxylate ether (PCE) based SPs in relation to neat cement using slump flow and rheological parameters. A range of grout mixtures was formulated containing micro silica (MS) and fly ash (FA), and tested for suitable rheological and mechanical parameters. Based on the results, a grout mixture with MS and FA was selected to determine optimum SRA content. According to the results, a SP dosage of 3% by weight of neat cement is sufficient to achieve saturation. The grout material including MS and FA can produce comparable properties to neat cement grout. MS is found to improve compressive strength within the range considered, whereas a higher FA content provides favourable rheological properties. Finally, a SRA dosage of 4%, which could reduce the shrinkage by about 43% after 28d days, is determined for the grout system.
Temperature variation can be a nuisance that perturbs vibration based structural health monitoring (SHM) approaches for civil engineering structures. In this paper, temperature affected vibration data is evaluated within a stochastic damage detection framework, which relies on a null space based residual. Besides two existing temperature rejection approaches – building a reference state from an averaging method or a piecewise method – a new approach is proposed, using model interpolation. In this approach, a general reference model is obtained from data in the reference state at several known reference temperatures. Then, for a particular tested temperature, a local reference model is derived from the general reference model. Thus, a well fitting reference null space for the formulation of a residual is available when new data is tested for damage detection at an arbitrary temperature. Particular attention is paid to the computation of the residual covariance, taking into account the uncertainty related to the null space matrix estimate. This improves the test performance, contrary to prior methods, for local and global damages, resulting in a higher probability of detection (PoD) for the new interpolation approach compared to previous approaches.
Die Grundidee einer Schwingungsminderung ist es eine tiefe Eigenfrequenz der Struktur zu erreichen, so dass höhere Frequenzen abgemindert werden. Das gilt für die Minderung an der Quelle, zum Beispiel einem Eisenbahngleis, und für die Minderung am Empfänger, dem Gebäude. Die Eigenfrequenz ermittelt man aus dem Verhältnis der Auflagersteifigkeit und der Masse. Wie ist die Masse bei einem Gebäude zu wählen? Und wie ist die Untergrundsteifigkeit zu berücksichtigen? Als Referenzsituation ohne Minderungsmaßnahme? Der Beitrag bringt Rechenergebnisse zu abgefederten Gebäuden mit einfachen und komplexen (FE-) Modellen, Mess- und Rechenergebnisse zur Schwingungsübertragung von unabgefederten Gebäuden. Es wird der Einfluss der Abstimmfrequenz, der Bodensteifigkeit und der „starren“ Gebäudemasse untersucht. Die komplexen Gebäudemodelle erlauben, neben der Berechnung einer elastischen Gebäudelagerung, auch die Variation von Gebäudeparametern zur Reduktion der Deckenschwingungen. Den Ergebnissen bei der Erschütterungs-übertragung in Gebäude werden zwei ähnliche Beispiele zur elastischen Maschinenlagerung und zur elastischen Gleislagerung gegenübergestellt.
Nach den bisherigen Regeln werden Bauwerksprüfungen von Brücken in starr definierten Intervallen durchgeführt. Diese starre, periodische, zustandsbasierte Instandhaltungsstrategie soll zukünftig durch eine flexible und prädiktive Instandhaltung ersetzt werden. Hierbei sollen Inspektionen und Instandhaltungsmaßnahmen unterstützt durch autonome Systeme auf der Grundlage von Monitoringdaten geplant und zusätzlich bei unvorhergesehenen Ereignissen ausgelöst werden. Im Rahmen des Verbundforschungsvorhabens AISTEC wird ein Vorgehen für Großbauwerke und kleinere Regelbauwerke zur Umsetzung eines kombinierten globalen, schwingungsbasierten und quasistatischen Monitorings entworfen. An der Maintalbrücke Gemünden – einer semiintegralen Rahmenbrücke aus Spannbeton auf der Schnellfahrstrecke Hannover–Würzburg – wurde als Demonstrator ein Dauermonitoring realisiert.
Structural health monitoring (SHM) of civil structures often is limited due to changing environmental conditions, as those changes affect the structural dynamical properties in a similar way like damages can do. In this article, an approach for damage detection under changing temperatures is presentedand applied to a beam structure. The used stochastic subspace-based algorithm relies on a reference null space estimate, which is confronted to data from the testing state in a residual function. For damage detection the residual is evaluated by means of statistical hypothesis tests. Changes of the system due to temperature effects are handled with a model interpolation approach from linear parameter varying system theory. From vibration data measured in the undamaged state at some few reference temperatures, a model of the dynamic system valid for the current testing temperature is interpolated. The reference null space and the covariance matrix for the hypothesis test is computed from this interpolated model. This approach has been developed recently and was validated in an academic test case on simulations of a mass-spring-damper. In this paper, the approach is validated experimentally on a beam structure under varying temperature conditions in a climate chamber. Compared to other approaches, the interpolation approach leads to significantly less false positive alarms in the reference state when the structure is exposed to different temperatures, while faults can still be detected reliably.
The subject of damage localization is an important issue for Structural Health Monitoring (SHM) particularly in mechanical or civil structures under ambient excitation. In this paper, the statistical subspacebased damage localization method has been applied on a benchmark application, namely a 1/200 scale model of the Saint-Nazaire Bridge, which is a cable-stayed bridge located on the Loire River near the river’s mouth. The employed damage localization method combines data-driven features with physical parameter information from a finite element model in statistical tests, avoiding typical ill-conditioning problems of FE model updating. Damage is introduced in the mockup for cable failures on some of the 72 cables. The purpose of the experiment is to assess the capability of damage assessment methods to find a cable failure.