7.2 Ingenieurbau
Filtern
Erscheinungsjahr
- 2018 (48) (entfernen)
Dokumenttyp
Referierte Publikation
- nein (48) (entfernen)
Schlagworte
- Monitoring (4)
- Repair (4)
- Fatigue (3)
- Interface (3)
- Acoustic emission testing (2)
- Amplitude-charge weight laws (2)
- Amplitude-distance laws (2)
- Analysis of variance (2)
- Big Data (2)
- Bitumen (2)
- Box-Behnken (2)
- Compressive cyclic loading (2)
- Compressive strength (2)
- Cracks (2)
- DUCON® (2)
- Datenmanagement (2)
- Ductility (2)
- E-modulus (2)
- Energy (2)
- Explosion-induced ground vibrations (2)
- Grouted Connection (2)
- Grouting (2)
- Hammer impact (2)
- High-strength concrete (2)
- Impact (2)
- Micro-reinforcement (2)
- Mobile elements (2)
- Non-destructive testing (2)
- Numerical model (2)
- Numerical modeling (2)
- Numerical modelling (2)
- Offshore (2)
- Offshore-Windenergieanlagen (2)
- Prediction of explosion induced ground and building vibration (2)
- Quasi-static and dynamic tests (2)
- Rehabilitation (2)
- SHM (2)
- Schadensdetektion (2)
- Schwingungsbasierte Verfahren (2)
- Size effect (2)
- Slab track (2)
- Slenderness effect (2)
- Soil properties (2)
- Soil-structure interaction (2)
- Stereo photogrammetry (2)
- Structural Health Monitoring (2)
- Supplementary cementitious materials (2)
- Track damage (2)
- UHPC (2)
- Ultrasonic testing (2)
- Unterraummethoden (2)
- Windenergie (2)
- 3D imaging (1)
- BIM (1)
- Ballast track (1)
- Bauwerk-Boden-Wechselwirkung (1)
- Bayes'sche Analyse (1)
- Beanspruchungszustand (1)
- Betonautobahn (1)
- Betonautobahnen (1)
- Boundary element method (1)
- Brücken (1)
- Cohesive soils (1)
- Compaction Grouting (1)
- Conductor (1)
- Crack (1)
- Crack detection (1)
- Crack repair (1)
- Cyclic axial shearing (1)
- DEM-LBM simulation (1)
- Deckenschwingungen (1)
- Design (1)
- Design methods (1)
- Design practice (1)
- Detection (1)
- Digital Image Correlation (1)
- Dispersionsmessung (1)
- Elastische Gebäudelagerung (1)
- Environmental (1)
- Ermüdungsschäden (1)
- Erosion (1)
- Erosion of cohesive soils (1)
- Erschütterungsprognose (1)
- Fatigue damage (1)
- Fault detection (1)
- Finite element model updating (1)
- Finite-Elemente-Modellkalibrierung (1)
- Freileitung (1)
- GPU parallelisation (1)
- Geomechanics (1)
- Geomechanics of offshore foundations (1)
- Ground vibration measurements (1)
- Grout (1)
- Grout Injection (1)
- HTLS (1)
- Innovative Messtechnik (1)
- Inspection planning (1)
- Interface model (1)
- Jet erosion test (1)
- LBM-DEM simulation (1)
- Laminography (1)
- Load bearing behaviour (1)
- Luminescence (1)
- Material Point Method (1)
- Material model (1)
- Messen im Bauwesen (1)
- Microfine cement (1)
- Micromechanical LBM-DEM simulation (1)
- Mix design (1)
- Offshore Pile Foundation (1)
- Offshore pile foundations (1)
- Offshore wind energy (1)
- Offshore wind farms (1)
- Offshore-Wind (1)
- Optimierungsmethoden (1)
- Optimization techniques (1)
- Physical phenomenology (1)
- Pile Capacity (1)
- Pile foundations (1)
- Probabilitische Ingenieurmodelle (1)
- Randelementmethode (1)
- Rechenmodelle (1)
- Reinforced concrete (1)
- Reliability (1)
- Residual evaluation (1)
- Risiko (1)
- Risikoanalyse (1)
- Risk (1)
- Risslumineszenz (1)
- Schwingungsmessungen (1)
- Shearing (1)
- Shrinkage (1)
- Soil erosion (1)
- Soil-pile interaction (1)
- State of stress (1)
- Statistical tests (1)
- Steel structures (1)
- TOP (1)
- Track vibration (1)
- Train configuration (1)
- Train passage (1)
- Train passages (1)
- Tran speed (1)
- Truss structures (1)
- Uncertainty in reference (1)
- Vibration measurement (1)
- Vibration measurements (1)
- Wave-Tower interaction (1)
- Wellenfeldberechnung (1)
- Windfarm wake analysis (1)
- Zivile Sicherheit (1)
- fachwerkartige Stahltragwerken (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (29)
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.
Grouting is a universal repair and strengthening technique, which is constantly used for structural remediation of concrete components, trenches, mine subsidence, dam joints, restoration of masonry structures, and geological stabilizations. Having an extremely small particle size of only few microns, ultrafine cements are ideal for grouting applications due to their superior permeability and compressive strength properties of the hardened cement paste compared to that of the less-expensive, but coarser ordinary Portland cements. Supplementary cementitious materials (SCMs) are often used to replace ultrafine cement in order to modify certain properties and to reduce costs. The aim of this experimental study is to investigate the effect of three supplementary materials: microsilica (MS), fly ash (FA), and metakaolin (MK) on the workability, and mechanical properties of an ultrafine cement based grout with a constant water-binder ratio and constant superplasticizer content. Maximum percentages of replacement with ultrafine cement were 6% by volume of cement for MS and 16% for FA, and MK. In general, results suggest that the workability is improved by addition of FA, whereas is reduced, when modified with MS and MK. The compressive strength of grout after cement replacement remains comparable to that of pure cement grout. However, there is a tendency of the MS to positively affect the compressive strength opposite to FA, whereas flexural strength is positively affected by FA. Based on the results, it is evident that grouts with Hägerman cone flow more than 500 mm and compressive strength of more than 90 MPa after 28 days can be produced.
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.
Superplasticizer and shrinkage reducing admixture dosages for microfine cement in grout systems
(2018)
Grouts have numerous applications including crack repair as maintenance in construction industries. Microfine cements are intensively used for high strength mortar and grout products. They are ideal for injection grouting in structural repair. Such grouts should have suitable rheological properties to be injectable, especially those used in repair and rehabilitation. The use of superplasticizers (SP) in these products is thus becoming increasingly crucial to achieve favorable workability and viscosity properties. A difficulty in such grouts is the plastic shrinkage due to finer particles used. It is thus necessary to determine optimum SP and shrinkage reducing admixture (SRA) dosages for a microfine cement based grout. In this study, a saturation dosage was decided from two Polycarboxylate ether (PCE) based SPs in relation to neat cement using slump flow and rheological parameters. A range of grout mixtures was formulated containing micro silica (MS) and fly ash (FA), and tested for suitable rheological and mechanical parameters. Based on the results, a grout mixture with MS and FA was selected to determine optimum SRA content. According to the results, a SP dosage of 3% by weight of neat cement is sufficient to achieve saturation. The grout material including MS and FA can produce comparable properties to neat cement grout. MS is found to improve compressive strength within the range considered, whereas a higher FA content provides favourable rheological properties. Finally, a SRA dosage of 4%, which could reduce the shrinkage by about 43% after 28d days, is determined for the grout system.
Grouting is a universal repair and strengthening technique, which is constantly used for structural remediation of concrete components, trenches, mine subsidence, dam joints, restoration of masonry structures, and geological stabilizations. Having an extremely small particle size of only few microns, ultrafine cements are ideal for grouting applications due to their superior permeability and compressive strength properties of the hardened cement paste compared to that of the less-expensive, but coarser ordinary Portland cements. Supplementary cementitious materials (SCMs) are often used to replace ultrafine cement in order to modify certain properties and to reduce costs. The aim of this experimental study is to investigate the effect of three supplementary materials: microsilica (MS), fly ash (FA), and metakaolin (MK) on the workability, and mechanical properties of an ultrafine cement based grout with a constant water-binder ratio and constant superplasticizer content. Maximum percentages of replacement with ultrafine cement were 6% by volume of cement for MS and 16% for FA, and MK. In general, results suggest that the workability is improved by addition of FA, whereas is reduced, when modified with MS and MK. The compressive strength of grout after cement replacement remains comparable to that of pure cement grout. However, there is a tendency of the MS to positively affect the compressive strength opposite to FA, whereas flexural strength is positively affected by FA. Based on the results, it is evident that grouts with Hägerman cone flow more than 500 mm and compressive strength of more than 90 MPa after 28 days can be produced.
Identifying optimal inspection and repair strategies for offshore jacket structures is a challenging task. We pre-sent an approach, which is based on recent developments in the field of risk-based operation and maintenance planning at the structural system level. The approach utilizes heuristics to define inspection and repair strate-gies at the system level and to reduce the search space of possible strategies. For each defined strategy, the expected service life cost of inspection, repair and failure is evaluated based on simulated inspection and re-pair histories. Subset simulation is applied to compute the conditional repair and failure probabilities required for this analysis. It also forms the basis for simulating inspection and repair histories. The strategy that mini-mizes the expected service life cost is the optimal one in the set of pre-selected strategies. The underlying condition and performance model accounts for the stochastic dependence among the deterioration states of the different structural elements and the structural redundancy. The approach is demonstrated in a case study considering a jacket-type frame. In this study, we essentially vary the inspection interval, the minimum num-ber of inspected components and the target reliability, and identify the combination that minimizes the ex-pected total service life cost.
Die Risikoanalyse ist ein formales Verfahren zur Unterstützung von Entscheidungen unter Unsicherheit und Risiko. Es ermöglicht eine Optimierung von Maßnahmen zur Verhinderung unerwünschter Konsequenzen. Der Vortrag stellt die aktuellen Aktivitäten an der BAM in dem Feld Risikoanalyse technischer System vor.