7.2 Ingenieurbau
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (19)
- Vortrag (6)
- Zeitschriftenartikel (3)
- Dissertation (1)
- Posterpräsentation (1)
Referierte Publikation
- nein (30) (entfernen)
Schlagworte
- Structural Health Monitoring (6)
- Impact (4)
- Damage characterization (3)
- Damage localization (3)
- Planar tomography (3)
- Structural health monitoring (3)
- Belastungsversuch (2)
- Cable failure (2)
- Cable-stayed bridge (2)
- Compressive strength (2)
- Crack detection (2)
- DUCON® (2)
- Ductility (2)
- E-modulus (2)
- Großer Fallturm Horstwalde (2)
- Load vector (2)
- Micro-reinforcement (2)
- Mobile elements (2)
- Modalanalyse (2)
- Model interpolation (2)
- Numeric simulation (2)
- Numerical modeling (2)
- Offshore-Windenergieanlagen (2)
- Quasi-static and dynamic tests (2)
- Reinforced concrete structure (2)
- SDDLV (2)
- Schadensdetektion (2)
- Schwingungsbasierte Verfahren (2)
- Schwingungsdynamik (2)
- Statistical evaluation (2)
- Stereo photogrammetry (2)
- Temperature rejection (2)
- Tomographic damage evaluation (2)
- UHPC (2)
- Unterraummethoden (2)
- 3D imaging (1)
- Ansys Autodyn (1)
- Artificial intelligence (1)
- Asymptotic local approach (1)
- BIM (1)
- Brücke (1)
- Changing process noise (1)
- Climate chamber (1)
- Crack (1)
- Damage detection (1)
- Detection (1)
- Digital Models (1)
- Drop Tests (1)
- Drop tower (1)
- Drucker-Prager (1)
- Ermüdungsschäden (1)
- Fallturm (1)
- Faseroptik (1)
- Fatigue (1)
- Fatigue damage (1)
- Fault detection (1)
- Finite Elemente Simulation (1)
- Global ambient vibrations (1)
- Hard impact (1)
- Harter Anprall an Stahlbetonstrukturen (1)
- Impact damage of reinforced concrete (1)
- Impact damage on reinforced concrete (1)
- Impakt (1)
- Laboratory beam structure (1)
- Laminography (1)
- Linear parameter varying systems (1)
- Luminescence (1)
- Monitoring (1)
- Multiple impact (1)
- Nelson’s method (1)
- Numerical damage simulation (1)
- Numerical simulation of impact damage (1)
- Offshore wind energy (1)
- Post-impact evaluation (1)
- Probability of detection (1)
- Prädiktive Instandhaltung (1)
- Radar (1)
- Reinforced concrete (1)
- Research data management (1)
- Risslumineszenz (1)
- Schadensüberwachung (1)
- Schwingungsmonitoring (1)
- Sensitivity vectors (1)
- Soft impact (1)
- Steel structures (1)
- Stress stiffening (1)
- Subspace methods (1)
- Subspace-based residual (1)
- System Identification (1)
- Temperature effects (1)
- Umwelteinflüsse (1)
- Vibration (1)
- building information modelling (1)
- structural health monitoring (1)
- structural integrity management (1)
- support structures (1)
Organisationseinheit der BAM
- 7.2 Ingenieurbau (30) (entfernen)
Eingeladener Vortrag
- nein (6)
Falltürme sind Bauwerke, die als Versuchsanlagen sehr speziellen, impulsartigen Belastungen ausgesetzt sind. Am Fallturm auf dem Testgelände Technische Sicherheit (TTS) der BAM wurde bei Routineinspektionen eine Abnahme der strukturellen Integrität in Form von Vorspannungsverlusten in den Bolzen der Stahlverbindungen festgestellt. Um ein Verständnis für die zugrundeliegenden Trag- und Schädigungsmechanismen zu erlangen, wurde ein umfassendes Structural Health Monitoring (SHM) System geplant und am Bauwerk installiert unter Nutzung von digitalen Bauwerksmodellen. Für die Auslegung des Überwachungssystems, insbesondere aber zur Unterstützung der Untersuchung des Schädigungsprozesses, wurden Finite-Elemente-Modelle erstellt. Um sicherzustellen, dass die FE-Modelle das reale Tragwerksverhalten mit ausreichender Genauigkeit abbilden, mussten sie jedoch in Bezug auf die gemessenen Antworten des Tragwerks kalibriert werden. Der vorliegende Beitrag beschreibt experimentelle und numerische Untersuchungen zur Identifizierung des strukturellen Systems des Stahlrohrgitterturms in Vorbereitung einer Überwachungskampagne. Die Auswertung von gemessenen Schwingungen unter ambienter Anregung ermöglichte die Identifizierung der Eigenfrequenzen mehrerer globaler Schwingungsmoden des Fallturms. Zur Modellvalidierung wurde zunächst eine Sensitivitätsanalyse durchgeführt, um die Parameter mit dem größten Einfluss zu ermitteln. Anschließend wurde ein evolutionärer Algorithmus (EA) zur Optimierung nach dem Prinzip der Minimierung der Differenzen zwischen gemessenen und simulierten charakteristischen Antworten eingesetzt. Das aktualisierte Modell wurde schließlich an der dynamischen Reaktion der Turmstruktur infolge einer realen Falltest-induzierten Stoßbelastung validiert. Die Ergebnisse zeigten eine gute Übereinstimmung zwischen numerischen und experimentellen Ergebnissen.
Structural health monitoring (SHM) of civil structures often is limited due to changing environmental conditions, as those changes affect the structural dynamical properties in a similar way like damages can do. In this article, an approach for damage detection under changing temperatures is presentedand applied to a beam structure. The used stochastic subspace-based algorithm relies on a reference null space estimate, which is confronted to data from the testing state in a residual function. For damage detection the residual is evaluated by means of statistical hypothesis tests. Changes of the system due to temperature effects are handled with a model interpolation approach from linear parameter varying system theory. From vibration data measured in the undamaged state at some few reference temperatures, a model of the dynamic system valid for the current testing temperature is interpolated. The reference null space and the covariance matrix for the hypothesis test is computed from this interpolated model. This approach has been developed recently and was validated in an academic test case on simulations of a mass-spring-damper. In this paper, the approach is validated experimentally on a beam structure under varying temperature conditions in a climate chamber. Compared to other approaches, the interpolation approach leads to significantly less false positive alarms in the reference state when the structure is exposed to different temperatures, while faults can still be detected reliably.
Nach den bisherigen Regeln werden Bauwerksprüfungen von Brücken in starr definierten Intervallen durchgeführt. Diese starre, periodische, zustandsbasierte Instandhaltungsstrategie soll zukünftig durch eine flexible und prädiktive Instandhaltung ersetzt werden. Hierbei sollen Inspektionen und Instandhaltungsmaßnahmen unterstützt durch autonome Systeme auf der Grundlage von Monitoringdaten geplant und zusätzlich bei unvorhergesehenen Ereignissen ausgelöst werden. Im Rahmen des Verbundforschungsvorhabens AISTEC wird ein Vorgehen für Großbauwerke und kleinere Regelbauwerke zur Umsetzung eines kombinierten globalen, schwingungsbasierten und quasistatischen Monitorings entworfen. An der Maintalbrücke Gemünden – einer semiintegralen Rahmenbrücke aus Spannbeton auf der Schnellfahrstrecke Hannover–Würzburg – wurde als Demonstrator ein Dauermonitoring realisiert.
Prediction of dynamic effects of reinforced concrete structures under impact loading is a technical challenge. This is a consequence of the great variability of the physical properties resulting from the wide adaptability of reinforced concrete and a consequence of the wide range of impact loading. Experiments and numerical investigations are normally used on a small scale to address the problem. In this paper, impact tests on reinforced conrete plates with the lateral dimensions of 1.5 m x 1.5 m and a thickness of 30 cm are presented. In bending reinforcement, besides the velocity two properties are varied, the diameter and the spatial distribution of the rebars. Experiments are performed at the Otto-Mohr-Laboratory of the Institute of Concrete Structures of the Technische Universit¨at Dresden. Due to the accelerated fall of the impactor the velocity ranges between 20 and 70 m/s. In addition to the measured quantities such as bearing forces, accelerations are also measured at 4 different positions on and under the plate, as well as the deflection at several positions. The measured data are used for the analysis of the damage form and the numerical examinations with the program Ansys Autodyn and the material model after Drucker-Prager.
Numerical investigations support the tests, with detailed analysis of individual effects. These numerical computations and the planar tomographic investigations were carried out at BAM in Berlin. With the help of planar tomographic evaluation, the damaged structure is
made visible and compared with the numerical results. Influences of the bending reinforcement are explained on the basis of damage evaluation in the local area and on selected measured values. In addition to the test evaluation, the tomographic and numerical methods are presented.
At the Bundesanstalt für Materialforschung und -prüfung (BAM) full scale specimens for nuclear transport and storage containers (casks) are tested for their structural integrity in a series of drop tests on the Test Site Technical Safety in Horstwalde, 50 km south of Berlin. These drop tests cause a major stress not only on the casks, but also on the steel tower structure of the test facility, itself. The load pattern makes the structure very interesting for detailed investigation. The focus of the monitoring lies on the bolted joints of the flange connections that are a typical connection for cylindrical elements if welding is technical or economical unfavorable. The definition of the monitoring takes was done by investigating the existing documents and inspection results accompanied by building an initial digital representation of the structure, consisting of two finite element (FE) models and a geometrical 3D point cloud representation. As a first step the structures behavior during static and dynamic loading was analyzed using measurement data and an updated numerical FE Model. The idea behind is to use models for a digital planning and operation/evaluation of the structural health monitoring. A static FE simulation and a dynamic FE simulation are generated, to investigate how the structure behaves under the load conditions.
Fault detection for linear parameter varying systems under changes in the process noise covariance
(2020)
Detecting changes in the eigenstructure of linear systems is a comprehensively investigated subject. In particular, change detection methods based on hypothesis testing using Gaussian residuals have been developed previously. In such residuals, a reference model is confronted to data from the current system. In this paper, linear output-only systems depending on a varying external physical parameter are considered. These systems are driven by process noise, whose covariance may also vary between measurements. To deal with the varying parameter, an interpolation approach is pursued, where a limited number of reference models -- each estimated from data measured in a reference state -- are interpolated to approximate an adequate reference model for the current parameter. The problem becomes more complex when the different points of interpolation correspond to different noise conditions. Then conflicts may arise between the detection of changes in the eigenstructure due to a fault and the detection of changes due to different noise conditions. For this case, a new change detection approach is developed based on the interpolation of the eigenstructure at the reference points. The resulting approach is capable of change detection when both the external physical parameter and the process noise conditions are varying. This approach is validated on a numerical simulation of a mechanical system.
Planar tomography and numerical analysis for damage characterization of impact loaded RC plates
(2020)
The damage analysis of reinforced concrete (RC) is of high interest for reasons of effective maintenance and structural safe-ty of buildings. The damage structures of RC plates loaded by an impact were investigated, applying X-ray planar tomogra-phy and finite element method (FEM). Planar tomography allows getting three-dimensional information of the RC elements and the damage including crack, spalling and scabbing. The FEM model validated on the tomography data justifies the appli-cation for further predictions of the damage description. In this study, we investigated concrete plates of three different thick-ness subjected to impacts at different low- and medium-velocity, whereby the used impactor had a flat tip, which resulted in small penetrations on the front side and scabbing on the rear side. In order to quantify the damage, the damage volume and its distribution through the plate were computed and the correlations between degree of damage and impact velocity were found out.
Reinforced concrete (RC) is used as structural material in most diverse civil engineering applications. For the variability of its physical properties it is still an engineering challenge to meet all necessary requirements for the prediction of dynamic effects under impact loading. In this paper, investigations are shown within the scope of quantifying and evaluating the damage caused by an impact. The experimental investigations are performed in the field of low- and medium-velocity impact. The chosen flat nose shape results in small penetrations on the top side and scabbing on the bottom side. The plate is scanned with an adapted planar tomographic examination after the impact, and the damage is analysed, afterwards. Cracks and spalling are made visible with a reconstruction. The numerical model validated on the tomographic results justifies the application for further predictions of the damage description.
At present, to produce renewable energy offshore wind farms play an important role. The available space combined with the more valuable wind conditions make offshore locations very attractive for wind powered energy production. In Europe a significant number of offshore wind farms already exist, especially in the North and Baltic Sea. In future this trend will continue, and further offshore wind farms will be built. The majority of offshore wind turbines are mounted on steel foundation structures. Due to the high-cyclic loading by wind and waves fatigue stress plays a substantial role regarding structural safety.
Besides the consideration of fatigue within the design process, to monitor existing steel structures for potential fatigue cracks during their life time is a major topic and a challenge.
For the structures of the offshore wind turbines are large and partially under water effective reliable methods for the detection of fatigue cracks are required.
This contribution presents investigations on different crack detection methods applied at high-cycle fatigue tests on small-scale welded steel samples as well as on large-scale welded steel components. The tests were conducted at the BAM laboratories. For crack detection mainly three different methods were used and compared. The first method regards to the measurement of strain by conventionally strain gauges. Secondly, the crack luminescence was used as a new and effective optical method for surface monitoring. And finally, crack detection by pressure differentials of the inner and outer section of tubular steel elements was investigated. A comparison study will emphasize the advantages and disadvantages of the different methods and show which of the described methods is potentially more suitable for an application on real offshore wind structures.
We examine the behavior of reinforced concrete components subjected to impact induced loading conditions which might be caused by vessels collisions such as aircraft fuel tanks The concrete plates were impact damaged at TU Dresden and shipped to BAM At BAM laminar tomography as the imaging method is used to determine and quantify the damage state An automatic crack detection method based on template matching is applied to find the cracks and we aim to develop a new method using machine learning Algorithms In addition numerical models are developed to understand the experiment and to predict the damage structures based on failure mechanisms.