7.2 Ingenieurbau
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (52) (entfernen)
Sprache
- Englisch (52) (entfernen)
Referierte Publikation
- nein (52) (entfernen)
Schlagworte
- Ground vibration (5)
- Structural health monitoring (5)
- Fatigue (4)
- Building vibration (3)
- Damage localization (3)
- Hammer impact (3)
- Impact (3)
- Layered soil (3)
- Vibration measurements (3)
- Bayesian updating (2)
- Cable failure (2)
- Cable-stayed bridge (2)
- Container loading (2)
- Damage characterization (2)
- Drop test (2)
- Foundation load (2)
- High-strength concrete (2)
- Load vector (2)
- Model interpolation (2)
- Offshore (2)
- Planar tomography (2)
- Repair (2)
- SDDLV (2)
- Soil-wall-floor model (2)
- Statistical evaluation (2)
- Structural Health Monitoring (2)
- Temperature rejection (2)
- Train passage (2)
- Train-induced ground vibration (2)
- Ultrasonic testing (2)
- Vehicle-track interaction (2)
- 2-span bridge (1)
- Acoustic emission testing (1)
- Amplitude-charge weight laws (1)
- Amplitude-distance laws (1)
- Analysis of variance (1)
- Analytical Design Methods (1)
- Ansys Autodyn (1)
- Apartment building (1)
- Artificial intelligence (1)
- Attenuation (1)
- Axle loads (1)
- Axle-sequence spectrum (1)
- BIM (1)
- Bayesian System Identification (1)
- Bayesian methods (1)
- Box-Behnken (1)
- Bridges (1)
- Changing process noise (1)
- Chemisoprtion (1)
- Climate chamber (1)
- Column/wall resonance (1)
- Compaction Grouting (1)
- Compressive Cyclic loading (1)
- Compressive cyclic loading (1)
- Compressive strength (1)
- Conductor (1)
- Coupler systems (1)
- Crack detection (1)
- Crack formation (1)
- Crack growth (1)
- Crack pattern (1)
- Cracks (1)
- Cyclic load (1)
- DEM (1)
- DUCON® (1)
- Damage detection (1)
- Deterioration (1)
- Digital Models (1)
- Digital twin (1)
- Displacements (1)
- Drone (1)
- Drop Tests (1)
- Drop tower (1)
- Drucker-Prager (1)
- Ductility (1)
- E-modulus (1)
- Earth masonry (1)
- Energy (1)
- Environmental effects (1)
- Evaluation (1)
- Excitation forces (1)
- Explosion-induced ground vibrations (1)
- Fault detection (1)
- Filter effects (1)
- Finite element models (1)
- Floor resonance (1)
- Foundation Pile (1)
- Foundation reliability analysis (1)
- Freight train (1)
- Freileitung (1)
- Granular Cohesive Materials (1)
- Ground vibration measurements (1)
- Grout (1)
- Grouted Connection (1)
- Grouted connection (1)
- Grouting (1)
- HTLS (1)
- Hard impact (1)
- High-Rise Building (1)
- High-speed (1)
- High-speed train (1)
- Horizontal stress (1)
- Impact damage on reinforced concrete (1)
- Inertial Interaction (1)
- Injection Sequence (1)
- Inspection (1)
- Inspection planning (1)
- Interface (1)
- Irregularities (1)
- Kinematic Interaction (1)
- Knudsen effect (1)
- Laboratory beam structure (1)
- Layered soils (1)
- Linear parameter varying systems (1)
- Long-span bridge (1)
- Macromechanical Sample Strength (1)
- Material moisture (1)
- Material tests (1)
- Measurement (1)
- Measurements (1)
- Micro-reinforcement (1)
- Micromechanical Tensile Failure (1)
- Mobile elements (1)
- Modal Analysis (1)
- Modal force spectrum (1)
- Modes (1)
- Molecular diffusion (1)
- Monitoring (1)
- Monopile installation risks (1)
- Multiple impact (1)
- NDT (1)
- Non destructive testing (1)
- Non-destructive testing (1)
- Numeric simulation (1)
- Numerical damage simulation (1)
- Numerical modeling (1)
- Numerical modelling (1)
- Office building (1)
- Office tower (1)
- Offshore Pile Foundation (1)
- Offshore Wind Energy (1)
- Offshore foundations (1)
- Offshore wind turbines (1)
- Optimal Sensor Placement (1)
- Passenger train (1)
- Physisorption (1)
- Pile Foundation (1)
- Post-impact evaluation (1)
- Prediction of explosion induced ground and building vibration (1)
- Probabilistic modelling (1)
- Propagation from a tunnel (1)
- Quasi-static and dynamic tests (1)
- Railway bridge (1)
- Railway tunnel (1)
- Randomly heterogeneous soil (1)
- Rehabilitation (1)
- Reinforced concrete structure (1)
- Reinforcement (1)
- Reliability (1)
- Research data management (1)
- Residential building (1)
- Risk (1)
- Scattering (1)
- Shearing (1)
- Shell Buckling (1)
- Simple prediction (1)
- Size effect (1)
- Slab track (1)
- Slenderness effect (1)
- Soft impact (1)
- Soil properties (1)
- Soil-Structure-Interaction (1)
- Soil-building interaction (1)
- Soil-building resonance (1)
- Soil-pile interaction (1)
- Soil-structure interaction (1)
- Spatially varying ground conditions (1)
- Static load (1)
- Steel structures (1)
- Stereo photogrammetry (1)
- Structural systems (1)
- Subspace methods (1)
- Subspace-based residual (1)
- Supplementary cementitious materials (1)
- Surface Foundation (1)
- Surface-tunnel reduction (1)
- System Identification (1)
- Temperature effects (1)
- Tensile Capacity (1)
- Time-variant reliability (1)
- Tomographic damage evaluation (1)
- Train speed (1)
- Transfer function (1)
- Tunnel-pile transfer (1)
- UHPC (1)
- Value of Information (1)
- Varying stiffness (1)
- Vehicle-track-soil interaction (1)
- Vibration (1)
- Vibration measurement (1)
- Waves (1)
- Welded (1)
- Wind (1)
- Wind Energy (1)
- Wind Turbines (1)
Organisationseinheit der BAM
- 7.2 Ingenieurbau (52) (entfernen)
Explosion-induced ground vibrations have been measured at several places. Results about the wave propagation are shown in this contribution. The particle velocities of the soil have been measured at up to 1000 m distance from the explosion and are presented as time records (seismograms) and one-third octave band spectra (transfer functions). The results are compared with the results of hammer impacts. The seismograms clearly show different wave types, compressional waves of the air, the water and the soil, and the Rayleigh wave. The hammer impacts yield good results up to 100 m and incorporate higher frequencies at about 50 Hz, whereas the explosion results in a ground vibration with frequencies around 10 Hz and a longer range of influence. Explosion and hammer excitations are evaluated for the wave velocities of the soil by using the wavenumber and the spatial auto-correlation method. The attenuation of the ground vibration amplitudes A with distance r can well be presented by a power law A ~ r -q. This type of amplitude-distance law and the corresponding power q > 1 are substantiated in the contribution. The influence of the charge weight W is evaluated as an additional power law A ~ W -p for each measuring site. The power is found quite similarly around q 0.6 as all sites have a medium soft soil such as sand and clay. The obtained amplitude-charge-distance law can be used to predict the explosion-induced ground and building vibrations at other sites.
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.