7.2 Ingenieurbau
Filtern
Dokumenttyp
- Vortrag (169)
- Beitrag zu einem Tagungsband (67)
- Zeitschriftenartikel (19)
- Posterpräsentation (10)
- Dissertation (4)
- Beitrag zu einem Sammelband (3)
- Buchkapitel (2)
- Sonstiges (2)
- Tagungsband (Herausgeberschaft für den kompletten Band) (1)
Sprache
- Englisch (199)
- Deutsch (77)
- Mehrsprachig (1)
Referierte Publikation
- nein (277) (entfernen)
Schlagworte
- Structural Health Monitoring (22)
- Ground vibration (18)
- Fatigue (11)
- Offshore wind energy (11)
- Structural health monitoring (11)
- Monitoring (10)
- Brücken (9)
- Offshore (9)
- Impact (8)
- Building vibration (7)
Organisationseinheit der BAM
- 7.2 Ingenieurbau (277) (entfernen)
Am Fallturm auf dem Testgelände Technische Sicherheit (TTS) der BAM wurden bei Inspektionen Vorspannungsverluste in den Bolzen der Stahlverbindungen festgestellt. Um ein Verständnis für die zugrundeliegenden Trag- und Schädigungsmechanismen zu erlangen und um den Zustand der vorgespannten Schraubverbindungen langzeitlich zu überwachen, wurde am Fallturm ein Structural Health Monitoring (SHM) System installiert. Für die Auslegung des Monitoringsystems sowie zur Unterstützung der Untersuchung des Schädigungsprozesses wurde ein numerisches Modell erstellt und in Bezug auf die gemessenen Antworten des Tragwerks kalibriert.
Im Vortrag werden die experimentellen und numerischen Untersuchungen zur Systemidentifikation des Stahlrohrgitterturms als auch die Überwachungskampagne mit dem eingesetzten Monitoringsystem sowie die Messergebnisse und deren Bewertung vorgestellt.
Right from the beginning of applying SHM to bridge structures it was obvious that environmental based perturbations on the measurement significantly influence the ability to identify structural damage. Strategies are needed to classify such effects and consider them appropriately in SHM. Various methods have been developed and analyzed to separate environmental based effects from damage induced changes in the measures. Generally, two main approaches have emerged from research activity in this fields: (a) statistics based tools analyzing patterns in the data or in computed parameters and (b) methods, utilizing the structural model of the bridge taking into account environmental as well as damage based changes of stiffness values.
With the back-ground of increasing affordability of sensing and computing technology, effort should be made to increase sensitivity, reliability and robustness of procedures, separating environmental from damage caused changes in SHM measures. The contribution describes both general strategies and points out their Advantages and drawbacks. As basis, a review on relevant methods was conducted. The aim of the study is to classify approaches for separating damage describing information from environmental based perturbations in dependency of the SHM objective. And such, it is intended to describe a best practice in designing concepts for Monitoring infrastructure, naturally effected by environmental influences.
Structural health monitoring (SHM) of civil structures often is limited due to changing environmental conditions, as those changes affect the structural dynamical properties in a similar way like damages can do. In this article, an approach for damage detection under changing temperatures is presentedand applied to a beam structure. The used stochastic subspace-based algorithm relies on a reference null space estimate, which is confronted to data from the testing state in a residual function. For damage detection the residual is evaluated by means of statistical hypothesis tests. Changes of the system due to temperature effects are handled with a model interpolation approach from linear parameter varying system theory. From vibration data measured in the undamaged state at some few reference temperatures, a model of the dynamic system valid for the current testing temperature is interpolated. The reference null space and the covariance matrix for the hypothesis test is computed from this interpolated model. This approach has been developed recently and was validated in an academic test case on simulations of a mass-spring-damper. In this paper, the approach is validated experimentally on a beam structure under varying temperature conditions in a climate chamber. Compared to other approaches, the interpolation approach leads to significantly less false positive alarms in the reference state when the structure is exposed to different temperatures, while faults can still be detected reliably
Structural health monitoring (SHM) of civil structures often is limited due to changing environmental conditions, as those changes affect the structural dynamical properties in a similar way like damages can do. In this article, an approach for damage detection under changing temperatures is presentedand applied to a beam structure. The used stochastic subspace-based algorithm relies on a reference null space estimate, which is confronted to data from the testing state in a residual function. For damage detection the residual is evaluated by means of statistical hypothesis tests. Changes of the system due to temperature effects are handled with a model interpolation approach from linear parameter varying system theory. From vibration data measured in the undamaged state at some few reference temperatures, a model of the dynamic system valid for the current testing temperature is interpolated. The reference null space and the covariance matrix for the hypothesis test is computed from this interpolated model. This approach has been developed recently and was validated in an academic test case on simulations of a mass-spring-damper. In this paper, the approach is validated experimentally on a beam structure under varying temperature conditions in a climate chamber. Compared to other approaches, the interpolation approach leads to significantly less false positive alarms in the reference state when the structure is exposed to different temperatures, while faults can still be detected reliably.
The subject of damage localization is an important issue for Structural Health Monitoring (SHM) particularly in mechanical or civil structures under ambient excitation. In this paper, the statistical subspacebased damage localization method has been applied on a benchmark application, namely a 1/200 scale model of the Saint-Nazaire Bridge, which is a cable-stayed bridge located on the Loire River near the river’s mouth. The employed damage localization method combines data-driven features with physical parameter information from a finite element model in statistical tests, avoiding typical ill-conditioning problems of FE model updating. Damage is introduced in the mockup for cable failures on some of the 72 cables. The purpose of the experiment is to assess the capability of damage assessment methods to find a cable failure.
The subject of damage localization is an important issue for Structural Health Monitoring (SHM) particularly in mechanical or civil structures under ambient excitation. In this paper, the statistical subspacebased damage localization method has been applied on a benchmark application, namely a 1/200 scale model of the Saint-Nazaire Bridge, which is a cable-stayed bridge located on the Loire River near the river’s mouth. The employed damage localization method combines data-driven features with physical parameter information from a finite element model in statistical tests, avoiding typical ill-conditioning problems of FE model updating. Damage is introduced in the mockup for cable failures on some of the 72 cables. The purpose of the experiment is to assess the capability of damage assessment methods to find a cable failure.
State of the art and development perspectives of deep foundations for offshore wind converters
(2020)
This presentation provides an overview of the main geotechnical aspects associated with deep foundations in the context of offshore wind generation. The most common deep foundation typologies (large diameter monopiles and multipile typologies) as well as new trends under development (e.g. suction buckets) and their current limits will be briefly described. The talk concludes with a brief review of advanced topics not covered in classical pile design, such as hydromechanical coupling effects (pore pressure generation), cyclic accumulation of deformations, cyclic degradation of axial capacity or pile-setup gains.
This document presents the specification for the execution and evaluation of high-speed tensile tests on reinforcement bar coupler systems. This specification was developed at BAM - Bundesanstalt für Materialforschung und -prüfung (Federal Institute for Materials Research and Testing, Germany) - following test principles from related international standards.
The present document represents the latest status of the test specification. It is noted that until 2010 the test procedure was characterised on a test velocity based on L0. In an improved test conception and after intensive investigations in cooperation with industry partners, this procedure has been updated to consider instead a test velocity based on Lr, since this warrants more comparable and meaningful results.