7.2 Ingenieurbau
Filtern
Dokumenttyp
- Vortrag (163)
- Beitrag zu einem Tagungsband (67)
- Zeitschriftenartikel (16)
- Posterpräsentation (10)
- Dissertation (4)
- Beitrag zu einem Sammelband (3)
- Buchkapitel (2)
- Tagungsband (Herausgeberschaft für den kompletten Band) (1)
- Sonstiges (1)
Sprache
- Englisch (192)
- Deutsch (74)
- Mehrsprachig (1)
Referierte Publikation
- nein (267) (entfernen)
Schlagworte
- Structural Health Monitoring (22)
- Ground vibration (18)
- Fatigue (12)
- Offshore wind energy (11)
- Structural health monitoring (11)
- Monitoring (10)
- Brücken (9)
- Offshore (9)
- Impact (8)
- Building vibration (7)
Organisationseinheit der BAM
- 7.2 Ingenieurbau (267) (entfernen)
Fatigue is one of the main deterioration processes affecting the performance of welded steel support structures of wind turbines in offshore wind farms. In this contribution, we present a probabilistic physics-based fatigue deterioration model of a wind farm that accounts for the stochastic dependence among the fatigue behavior of different hotspots at turbine and wind farm level. The dependence exists because of uncertain common influencing factors such as similar material properties, fabrication qualities and load conditions. These system effects signify that an inspection of one hotspot provides indirect information of the condition of the remaining hotspots and thus enable an optimization of the inspection effort for a wind farm.
The wind farm model consists of two levels: A turbine support structure (level 1 system model) is represented by its fatigue hotspots and their stochastic dependence. The fatigue performance of a hotspot is described by a probabilistic fracture mechanics (FM) fatigue model. The probabilistic model of the parameters of the FM fatigue model is calibrated based on design data and is thus directly linked to the design of the turbine support structures. Dependence among the fatigue performances of different hotspots in a turbine support structure is modeled by introducing correlations between the stochastic parameters of the FM fatigue models. A wind farm (level 2 system model) consists of different turbine support structures (level 1 system models). Additional correlations are introduced at wind farm level to account for the dependence among the fatigue behavior of hotspots belonging to different turbine support structures. The wind farm model enables the computation of (marginal) hotspot fatigue reliabilities, system fatigue reliabilities of individual turbine support structures and the system fatigue reliability of an entire wind farm. The probabilistic model of the parameters of the two-level system model can be consistently updated with inspection outcomes using Bayesian methods. The updated probabilistic model of the model parameters then forms the basis for updating the estimates of the fatigue reliabilities.
We implement the wind farm model in a software tool named SysPark. The tool provides the means for planning inspections at wind farm level using an adaptive reliability-based threshold approach. In this approach, the first inspection campaign is planned in the year before the fatigue failure rates of the hotspots with the lowest fatigue reliabilities exceed a threshold failure rate. Once inspection results become available, the probabilistic model of the parameters of the wind farm model is updated. If repairs are performed, the wind farm model is additionally modified to describe the behavior of the repaired hotspots. The updated and modified model then enables the planning of the next inspection campaign and so on. The software tool is demonstrated in a case study considering a generic wind farm consisting of turbines with jacket support structures.
Superplasticizer and shrinkage reducing admixture dosages for microfine cement in grout systems
(2018)
Grouts have numerous applications including crack repair as maintenance in construction industries. Microfine cements are intensively used for high strength mortar and grout products. They are ideal for injection grouting in structural repair. Such grouts should have suitable rheological properties to be injectable, especially those used in repair and rehabilitation. The use of superplasticizers (SP) in these products is thus becoming increasingly crucial to achieve favorable workability and viscosity properties. A difficulty in such grouts is the plastic shrinkage due to finer particles used. It is thus necessary to determine optimum SP and shrinkage reducing admixture (SRA) dosages for a microfine cement based grout. In this study, a saturation dosage was decided from two Polycarboxylate ether (PCE) based SPs in relation to neat cement using slump flow and rheological parameters. A range of grout mixtures was formulated containing micro silica (MS) and fly ash (FA), and tested for suitable rheological and mechanical parameters. Based on the results, a grout mixture with MS and FA was selected to determine optimum SRA content. According to the results, a SP dosage of 3% by weight of neat cement is sufficient to achieve saturation. The grout material including MS and FA can produce comparable properties to neat cement grout. MS is found to improve compressive strength within the range considered, whereas a higher FA content provides favourable rheological properties. Finally, a SRA dosage of 4%, which could reduce the shrinkage by about 43% after 28d days, is determined for the grout system.
Temperature variation can be a nuisance that perturbs vibration based structural health monitoring (SHM) approaches for civil engineering structures. In this paper, temperature affected vibration data is evaluated within a stochastic damage detection framework, which relies on a null space based residual. Besides two existing temperature rejection approaches – building a reference state from an averaging method or a piecewise method – a new approach is proposed, using model interpolation. In this approach, a General reference model is obtained from data in the reference state at several known reference temperatures.
Then, for a particular tested temperature, a local reference model is derived from the general reference model. Thus, a well fitting reference null space for the formulation of a residual is available when new data is tested for damage detection at an arbitrary temperature. Particular attention is paid to the computation of the residual covariance, taking into account the uncertainty related to the null space Matrix estimate. This improves the test performance, contrary to prior methods, for local and global damages, resulting in a higher probability of detection (PoD) for the new interpolation approach compared to previous approaches.
Automated vibration-based damage detection is of increasing interest for structural health monitoring of engineering structures. In this context, stochastic subspace-based damage detection (SSDD) compares measurements from a testing state to a data-driven reference model in a statistical framework. In this thesis theoretical developments have been proposed to improve the robustness of SSDD for realistic applications conditions. First, a statistical test has been proposed considering the statistical uncertainties about the model obtained from the reference data. This leads to a precise description of the test’s distribution properties and damage detection thresholds. Second, an approach has been developed to account for environmental effects in SSDD. Based on reference measurements at few different environmental conditions, a test is derived with respect to an adequate interpolated reference.
The proposed methods are validated in numerical simulations and applied to experimental data from the laboratory and outdoor structures.
Subspace-based damage detection handling temperature effects and uncertainty in the reference
(2019)
Temperature variation can be a nuisance that perturbs vibration based structural health monitoring (SHM)approaches for civil engineering structures. In this paper, temperature affected vibration data is evaluated within a stochastic damage detection framework, which relies on a null space based residual. Besides two existing temperature rejection approaches – building a reference state from an averaging method or a piecewise method – a new approach is proposed, using model interpolation. In this approach, a general reference model is obtained from data in the reference state at several known reference temperatures. Then, for a particular tested temperature, a local reference model is derived from the general reference model. Thus, a well fitting reference null space for the formulation of a residual is available when new data is tested for damage detection at an arbitrary temperature. Particular attention is paid to the computation of the residual covariance, taking into account the uncertainty related to the null space matrix estimate. This improves the test performance, contrary to prior methods, for local and global damages, resulting in a higher probability of detection (PoD) for the new interpolation approach compared to previous approaches.
Die Grundidee einer Schwingungsminderung ist es eine tiefe Eigenfrequenz der Struktur zu erreichen, so dass höhere Frequenzen abgemindert werden. Das gilt für die Minderung an der Quelle, zum Beispiel einem Eisenbahngleis, und für die Minderung am Empfänger, dem Gebäude. Die Eigenfrequenz ermittelt man aus dem Verhältnis der Auflagersteifigkeit und der Masse. Wie ist die Masse bei einem Gebäude zu wählen? Und wie ist die Untergrund-steifigkeit zu berücksichtigen? Als Referenzsituation ohne Minderungsma߬nahme? Der Beitrag bringt Rechenergebnisse zu abgefederten Gebäuden mit einfachen und komplexen (FE-) Modellen, Mess- und Rechenergebnisse zur Schwingungsübertragung von unabge-federten Gebäuden. Es wird der Einfluss der Abstimmfrequenz, der Bodensteifigkeit und der „starren“ Gebäudemasse untersucht. Die komplexen Gebäudemodelle erlauben, neben der Berechnung einer elastischen Gebäudelagerung, auch die Variation von Gebäudepara¬metern zur Reduktion der Deckenschwingungen. Den Ergebnissen bei der Erschütterungs-übertragung in Gebäude werden zwei ähnliche Beispiele zur elastischen Maschinenlagerung und zur elastischen Gleislagerung gegenübergestellt.
Nach den bisherigen Regeln werden Bauwerksprüfungen von Brücken in starr definierten Intervallen durchgeführt. Diese starre, periodische, zustandsbasierte Instandhaltungsstrategie soll zukünftig durch eine flexible und prädiktive Instandhaltung ersetzt werden. Hierbei sollen Inspektionen und Instandhaltungsmaßnahmen unterstützt durch autonome Systeme auf der Grundlage von Monitoringdaten geplant und zusätzlich bei unvorhergesehenen Ereignissen ausgelöst werden. Im Rahmen des Verbundforschungsvorhabens AISTEC wird ein Vorgehen für Großbauwerke und kleinere Regelbauwerke zur Umsetzung eines kombinierten globalen, schwingungsbasierten und quasistatischen Monitorings entworfen. An der Maintalbrücke Gemünden – einer semiintegralen Rahmenbrücke aus Spannbeton auf der Schnellfahrstrecke Hannover–Würzburg – wurde als Demonstrator ein Dauermonitoring realisiert.
Am Fallturm auf dem Testgelände Technische Sicherheit (TTS) der BAM wurden bei Inspektionen Vorspannungsverluste in den Bolzen der Stahlverbindungen festgestellt. Um ein Verständnis für die zugrundeliegenden Trag- und Schädigungsmechanismen zu erlangen und um den Zustand der vorgespannten Schraubverbindungen langzeitlich zu überwachen, wurde am Fallturm ein Structural Health Monitoring (SHM) System installiert. Für die Auslegung des Monitoringsystems sowie zur Unterstützung der Untersuchung des Schädigungsprozesses wurde ein numerisches Modell erstellt und in Bezug auf die gemessenen Antworten des Tragwerks kalibriert.
Im Vortrag werden die experimentellen und numerischen Untersuchungen zur Systemidentifikation des Stahlrohrgitterturms als auch die Überwachungskampagne mit dem eingesetzten Monitoringsystem sowie die Messergebnisse und deren Bewertung vorgestellt.