Driven steel piles are commonly used as deep foundations for a wide range of engineering structures, particularly in the offshore branch. They are also an interesting example among the broad spectrum of geotechnical applications where the fluid-solid interaction at the pore-scale can play a major role for the macromechanical behaviour of the whole system.
In the context of the geotechnical practice for offshore wind-farm structures, both the industrial design and the actual dimensions of the large piles used as foundations in the seabed are often driven by factors such as the soil resistance to driving (SRD), which are still not well understood and often estimated based on mere empirical correlations or overly simplified one-dimensional models. In particular, the role of the micromechanical effects during the installation process (e.g. local dilatancy or contractancy) and their consequences on the pore pressure levels at the pile-tip and on the effective resistance to driving, are generally either disregarded or at most assumed to be covered by the simplified engineering “black-box” solutions.
Here, we propose a general framework to address such local aspects of a geotechnical application involving fluid-saturated soils while retaining the focus on the micro-scale phenomena. We advocate for an approach that combines the relative simplicity of the Discrete Element Method (DEM) for the solid mechanics with the capabilities of the Lattice Boltzmann Method (LBM) for the fluid dynamics. In this sense, we aim to compile some useful techniques and practical recommendations for an efficient GPU-based implementation of a micromechanical LBM-DEM simulation tool.
The identification of the dynamic behavior of structures, like bridges and towers, is relevant to address multiple issues. In many cases the dynamic parameters should be acquired only once or at a frequency that doesn’t justify the installation of distinct vibration sensors for a long-term monitoring. To identify modal frequencies of a structure, a drone based mobile sensing platform has been implemented. This sensing platform measures the relative displacement be-tween the structure and the drone, which also shows a strong dynamic behavior under wind tur-bulences. By regarding the dynamic model of the drone and additional measurements at the dis-tance sensor the absolute movement of the structure can be estimated based on the measured relative distance. This time domain data is a suitable input for various operational modal analysis algorithms. The system has been used to identify the dynamic properties of test and real structure, like a 1.5 MW wind turbine tower.
Subspace-based damage detection handling temperature effects and uncertainty in the reference
(2019)
Temperature variation can be a nuisance that perturbs vibration based structural health monitoring (SHM)approaches for civil engineering structures. In this paper, temperature affected vibration data is evaluated within a stochastic damage detection framework, which relies on a null space based residual. Besides two existing temperature rejection approaches – building a reference state from an averaging method or a piecewise method – a new approach is proposed, using model interpolation. In this approach, a general reference model is obtained from data in the reference state at several known reference temperatures. Then, for a particular tested temperature, a local reference model is derived from the general reference model. Thus, a well fitting reference null space for the formulation of a residual is available when new data is tested for damage detection at an arbitrary temperature. Particular attention is paid to the computation of the residual covariance, taking into account the uncertainty related to the null space matrix estimate. This improves the test performance, contrary to prior methods, for local and global damages, resulting in a higher probability of detection (PoD) for the new interpolation approach compared to previous approaches.
The shaft bearing capacity often plays a dominant role for the overall structural behaviour of axially loaded piles in offshore deep foundations. Under cyclic loading, a narrow zone of soil at the pile-soil interface is subject to cyclic shearing solicitations. Thereby, the soil may densify and lead to a decrease of confining stress around the pile due to microphenomena such as particle crushing, migration and rearrangement. This reduction of radial stress has a direct impact on the shaft capacity, potentially leading in extreme cases to pile failure. An adequate interface model is needed in order to model this behaviour numerically. Different authors have proposed models that take typical Interface phenomena in account such as densification, grain breakage, normal pressure effect and roughness. However, as the models become more complex, a great number of material parameters need to be defined and calibrated. This paper proposes the adoption and transformation of an existing soil bulk model (Pastor- Zienkiewicz) into an interface model. To calibrate the new interface model, the results of an experimental campaign with the ring shear device under cyclic loading conditions are here presented. The constitutive model shows a good capability to reproduce typical features of sand behaviour such as cyclic compaction and dilatancy, which in saturated partially-drained conditions may lead to liquefaction and cyclic mobility phenomena.
The structural performance of many geotechnical systems (e.g. axially-loaded pile foundations), depends on the shearing resistance at the soil interface, which may govern the load bearing capacity of the foundation. Experimental investigations have shown that this interaction is mainly localised within a narrow shear band next to the structure. Under cyclic loading, a contraction of the soil at the interface may arise (net volume loss), possibly leading to a stress relaxation and thus to a reduction of the load bearing capacity (the so-called friction fatigue). Based on the constitutive similarities between soil continua and interfaces, we propose here the adaption of a Generalized Plasticity model for sandy soils for the numerical analysis of interface problems. In this contribution, the results of an experimental campaign for the parameter calibration of the constitutive model are presented. The tests have been conducted with a ring shear device involving different normal stresses, roughness of the steel plates as well as cyclic loading. The new modelling approach shows promising results and has the additional practical advantage that the interface zone and the soil continuum can both be described with the same constitutive model in general boundary value problems.
Measured train passages and hammer impacts in combination with track-soil calculation have been successfully used for the detection of damaged slab tracks. This approach is now extended to intact slab and ballast tracks. The vibrations of many tracks have been measured at several levels from rail, sleeper, track plate, base plate, base layer to the subsoil by velocity or acceleration sensors. The time histories have to be integrated once or twice to get the displacements. The displacement signals include an arbitrary time-dependent shift which must be eliminated or respected in the interpretation. On the other hand, the calculation of slab and ballast tracks have been done in frequency-wavenumber domain. The displacements along the track and the frequency-dependent compliance transfer functions can be calculated. The latter can be compared with the results of the hammer impacts on the track. The deformation of the track can be transformed to time histories for a whole train and compared to the measured train passages. Many slab (and ballast) tracks have been measured at different sites. The displacements of the tracks are presented, and the following parameters have been analysed in the measurement results: slab track vs. ballast track, different types of slab tracks, damaged slab tracks, different trains, switches at different measuring points, an elastic layer, the mortar layer, different soils at different places. The soil should have the dominant influence on the track-plate displacements. Slab and ballast track yield also big differences in maximum displacement and width of deformation. Some of the preceding aspects will be analysed in comparison of measurement and theory.
The increasing use of renewable energies leads to a constant search for optimised foundation concepts aiming to reduce the costs for offshore wind turbines. In an ongoing research project, we are developing a design approach for typical offshore driven piles based on the application of injections by compaction grouting directly at the pile shaft. Compaction grouting as a ground improvement technique has been used widely as a countermeasure against liquefaction, settlement and low bearing capacity of soil under new or already existing structures. It is performed by forcing highly viscous grout into the soil to displace and compact the surrounding soil without fracturing or penetrating it. Regarding this injection method, this paper gives a brief overview about general aspects such as appropriate soil characteristics and grouting parameters, grouting equipment and fields of application particularly in the offshore sector. This indicates the ability of our optimisation concept to provide an economic alternative to larger pile dimensions and a retrofitting technique, which is available during the entire lifetime of the foundation and can be deployed only in case of necessity (e.g. excessive deformations or insufficient structural stiffness after an extreme load event).
Besides the material feasibility and the constructive realisation of this improvement measure, the development of a corresponding verification concept is crucial in order to ensure the safety and durability of the retrofitted offshore piles. Here we will examine various verification concepts with their respective limitations in the framework of the limit state design. Furthermore, we will present the experimental findings from field tests in sand indicating the advantages of several local injections by compaction grouting for the enhancement of the load bearing behaviour of pile foundations. The test results were also used to validate a numerical model, developed with the finite element program PLAXIS, aiming to predict the expected bearing capacity for different injection scenarios (e.g. grout volume, location of injection points) along a pile shaft.