7.2 Ingenieurbau
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (9)
- Vortrag (9)
- Zeitschriftenartikel (3)
Referierte Publikation
- nein (21) (entfernen)
Schlagworte
- Structural Health Monitoring (8)
- Datenmanagement (3)
- BIM (2)
- Belastungsversuch (2)
- Big Data (2)
- Bridges (2)
- Drone (2)
- Großer Fallturm Horstwalde (2)
- Modal Analysis (2)
- Modalanalyse (2)
- Schwingungsdynamik (2)
- Structural health monitoring (2)
- System Identification (2)
- Vibration (2)
- Wind Turbines (2)
- Windenergie (2)
- AISTEC (1)
- Acceleration sensors (1)
- Artificial intelligence (1)
- Automatic modal parameters identification (1)
- Bauwerksüberwachung (1)
- Bayesian methods (1)
- Belastungszug (1)
- Bridge monitoring (1)
- Brücken (1)
- Climate chamber (1)
- Damage Detection (1)
- Damage detection (1)
- Digital Models (1)
- Digital Twin (1)
- Drop Test (1)
- Drop Tests (1)
- EERA Joint Program (1)
- Einflusslinie (1)
- Environmental effects (1)
- Environmental influence (1)
- FEM analysis (1)
- Finite Elemente Simulation (1)
- IEPE (1)
- Laboratory beam structure (1)
- Load Test (1)
- Low-frequency shaker (1)
- MEMS (1)
- Maintal Bridge Gemuenden (1)
- Maintalbrücke Gemünden (1)
- Messen im Bauwesen (1)
- Messfahrt (1)
- Model interpolation (1)
- Monitoring (1)
- Offshore (1)
- Offshore wind energy (1)
- Point Cloud (1)
- Prädiktive Instandhaltung (1)
- Railway (1)
- Research data management (1)
- SHM (1)
- Subspace methods (1)
- Tagung (1)
- Temperature effects (1)
- Umwelteinflüsse (1)
- Vibration analysis (1)
- Wind energy (1)
- Zivile Sicherheit (1)
- building information modelling (1)
- structural health monitoring (1)
- structural integrity management (1)
- support structures (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (9)
Falltürme sind Bauwerke, die als Versuchsanlagen sehr speziellen, impulsartigen Belastungen ausgesetzt sind. Am Fallturm auf dem Testgelände Technische Sicherheit (TTS) der BAM wurde bei Routineinspektionen eine Abnahme der strukturellen Integrität in Form von Vorspannungsverlusten in den Bolzen der Stahlverbindungen festgestellt. Um ein Verständnis für die zugrundeliegenden Trag- und Schädigungsmechanismen zu erlangen, wurde ein umfassendes Structural Health Monitoring (SHM) System geplant und am Bauwerk installiert unter Nutzung von digitalen Bauwerksmodellen. Für die Auslegung des Überwachungssystems, insbesondere aber zur Unterstützung der Untersuchung des Schädigungsprozesses, wurden Finite-Elemente-Modelle erstellt. Um sicherzustellen, dass die FE-Modelle das reale Tragwerksverhalten mit ausreichender Genauigkeit abbilden, mussten sie jedoch in Bezug auf die gemessenen Antworten des Tragwerks kalibriert werden. Der vorliegende Beitrag beschreibt experimentelle und numerische Untersuchungen zur Identifizierung des strukturellen Systems des Stahlrohrgitterturms in Vorbereitung einer Überwachungskampagne. Die Auswertung von gemessenen Schwingungen unter ambienter Anregung ermöglichte die Identifizierung der Eigenfrequenzen mehrerer globaler Schwingungsmoden des Fallturms. Zur Modellvalidierung wurde zunächst eine Sensitivitätsanalyse durchgeführt, um die Parameter mit dem größten Einfluss zu ermitteln. Anschließend wurde ein evolutionärer Algorithmus (EA) zur Optimierung nach dem Prinzip der Minimierung der Differenzen zwischen gemessenen und simulierten charakteristischen Antworten eingesetzt. Das aktualisierte Modell wurde schließlich an der dynamischen Reaktion der Turmstruktur infolge einer realen Falltest-induzierten Stoßbelastung validiert. Die Ergebnisse zeigten eine gute Übereinstimmung zwischen numerischen und experimentellen Ergebnissen.
Acceleration sensors are vital for assessing engineering structures by measuring properties like natural frequencies. In practice, engineering structures often have low natural frequencies and face harsh environmental conditions. Understanding sensor behavior on such structures is crucial for reliable masurements. The research focus is on understanding the behavior of acceleration sensors in harsh environmental conditions within the low-frequency acceleration range. The main question is how to distinguish sensor behavior from structural influences to minimize errors in assessing engineering structure conditions. To investigate this, the sensors are tested using a long-stroke calibration unit under varying temperature and humidity conditions. Additionally, a mini-monitoring system configured with four IEPE sensors is applied to a small-scale support structure within a climate chamber. For the evaluation, a signal-energy approach is employed to distinguish sensor behavior from structural behavior. The findings show that IEPE sensors display temperature-dependent nonlinear transmission behavior within the low-frequency acceleration range, with humidity having negligible impact. To ensure accurate engineering structure assessment, it is crucial to separate sensor behavior from structural influences using signal energy in the time domain. This study underscores the need to compensate for systematic effects, preventing the underestimation of vibration energy at low temperatures and overestimation at higher temperatures when using IEPE sensors for engineering structure monitoring.
Support structures of wind turbines in German offshore wind farms are regularly inspected. Currently, inspection outcomes are generally not systematically recorded. This prevents their consistent handling and processing, which is a key requirement to enable an efficient structural integrity management. As part of the DiMoWind-Inspect project, a data model and reference designation system for such inspection results is developed to facilitate their identification, localization, quantification, tracing and linking throughout the lifetime of a wind farm and beyond. The inspection results together with structural health monitoring results and information on repairs form the basis for assessing and predicting the structural condition, estimating the remaining lifetime, and planning of future inspections, structural health monitoring, and repairs. As a basis for developing a digital structural integrity management, a generic framework is proposed in this paper, which describes the stakeholders, data, models, processes and workflows of the integrity management of support structures in offshore wind farms and their interrelations. The framework adopts a building information modelling approach to describe the information relevant to the structural integrity management. The central digital space of the framework is a common data environment. An implementation of the framework will enable a digital structural integrity management in which inspection, structural health monitoring, repair, assessment and planning outcomes generated throughout the life cycle of a wind farm can be consistently collected, managed, shared and processed by the relevant shareholders.
The identification of the dynamic behavior of structures, like bridges and towers, is relevant to address multiple issues. In many cases the dynamic parameters should be acquired only once or at a frequency that doesn’t justify the installation of distinct vibration sensors for a long-term monitoring. To identify modal frequencies of a structure, a drone based mobile sensing platform has been implemented. This sensing platform measures the relative displacement be-tween the structure and the drone, which also shows a strong dynamic behavior under wind tur-bulences. By regarding the dynamic model of the drone and additional measurements at the dis-tance sensor the absolute movement of the structure can be estimated based on the measured relative distance. This time domain data is a suitable input for various operational modal analysis algorithms. The system has been used to identify the dynamic properties of test and real structure, like a 1.5 MW wind turbine tower.
At the Bundesanstalt für Materialforschung und -prüfung (BAM) full scale specimens for nuclear transport and storage containers (casks) are tested for their structural integrity in a series of drop tests on the Test Site Technical Safety in Horstwalde, 50 km south of Berlin. These drop tests cause a major stress not only on the casks, but also on the steel tower structure of the test facility, itself. The load pattern makes the structure very interesting for detailed investigation. The focus of the monitoring lies on the bolted joints of the flange connections that are a typical connection for cylindrical elements if welding is technical or economical unfavorable. The definition of the monitoring takes was done by investigating the existing documents and inspection results accompanied by building an initial digital representation of the structure, consisting of two finite element (FE) models and a geometrical 3D point cloud representation. As a first step the structures behavior during static and dynamic loading was analyzed using measurement data and an updated numerical FE Model. The idea behind is to use models for a digital planning and operation/evaluation of the structural health monitoring. A static FE simulation and a dynamic FE simulation are generated, to investigate how the structure behaves under the load conditions.
Mit der Errichtung und der Inbetriebnahme des Windpark alpha ventus wurden umfangreiche Messungen an den Tragstrukturen und den Umgebungsparametern durchgeführt. Im Projekt Gigawind life wurde im TP1 ein Datenmanagementsystem zur kontinuierlichen und periodisch fortgeführten Datenauswertung für große Datenbestände (Big Data) entworfen und realisiert. Anhand von Performanceuntersuchungen konnte eine Verkürzung der Rechenzeit um den Faktor 10 in einem Rechencluster erreicht werden. Unter Anwendung einer Datenpipeline nach dem Publish/Subscribe Prinzip wird eine skalierbare Datenschnittstelle für Monitoringdaten vorgeschlagen.
The long-term preservation of our infrastructure requires not only intelligent sensor technology and highly developed monitoring procedures, but also innovative digital tools for analyzing, evaluating and utilizing the results. This includes mathematical and, in particular, probabilistic methods for damage detection and tracking as well as for calculating service life and maintenance cycles and data management. The example project Maintal Bridge Gemuenden as part of the AISTEC project shows the workflow for the implementation of structural health monitoring and experimental tests with a train of Deutsche Bahn. The influence lines, as one possible way for damage detection, were measured with a highly accurate GNSS System to locate the trains position when crossing the bridge. The results were compared to measurements from 1987 just before the bridge went in operation.
Der Vortrag stellt die Durchführung und die ersten Ergebnisse der Belastungsfahrten der BAM im Rahmen des AISTEC Projekts an der Maintalbrücke am 19.05. und 20.05.2021 vor. Es wurden Tragwerksreaktionen des Bauwerks mit dem installierten Dauermonitoringsystem und insbesondere dem Betongelenk mit zusätzlich installierter Sensorik aufgezeichnet. Für die Ermittlung der Lastposition wurden mehrere Verfahren eingesetzt und verglichen.