6.7 Materialsynthese und Design
Filtern
Dokumenttyp
- Vortrag (28)
- Beitrag zu einem Tagungsband (7)
- Zeitschriftenartikel (5)
- Forschungsbericht (5)
Schlagworte
Organisationseinheit der BAM
- 6 Materialchemie (45)
- 6.7 Materialsynthese und Design (45)
- 8 Zerstörungsfreie Prüfung (6)
- 8.6 Faseroptische Sensorik (6)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 6.2 Material- und Oberflächentechnologien (3)
- 6.1 Oberflächen- und Dünnschichtanalyse (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.5 Proteinanalytik (1)
Eingeladener Vortrag
- nein (28)
The paper addresses the “Functional coatings for mechanical applications: characterization and standardization” and the following points are discussed in more detail:
1. Mechanic alapplications (coatings for tools and components, system features vs. material parameters)
2. Mechanical characterization (instrumented indentation testing (IIT), centrifugal adhesion testing (CAT), state of standardization)
3. Topometric characterization (white light interference microscopy (WLIM, 3D), mechanical stylus (MS, 2D), state of standardization)
4. Optical characterization (spectroscopic ellipsometry (SE), inter-laboratory comparison, state of standardization)
Proposal for revision of en 15870 „Adhesives determination of tensile strength of butt joints”
(2021)
The paper addresses the PROPOSAL FOR REVISION OF EN 15870
„ADHESIVES -DETERMINATION OF TENSILE STRENGTH OF BUTT JOINTS” “ and the follow points are discussed in more detail: Adhesives-Determination of tensile strength of butt joints, Introduction of Centrifugal Adhesion Testing, Comparison of Testing Methods.
The lack of on-line validation procedures for structure-embedded fiber-optical strain sensors, in particular fiber-Bragg-gratings (FBG), resulted in limited applications in structural health monitoring (SHM). Degradation under service conditions and ageing as a result of climatic influences or delamination under load were unsolved Validation issues. This could be overcome by means of an auto-diagnosis procedure based on FBG-sensors coated by electrochemical deposition (ECD) with a magnetostrictive NiFe-coating on top of an adhesive Cu/Cr adhesive layer deposited by physical vapour deposition (PVD) around the FBG strain sensor. This allows at any time under Service a validation of sensor functionality, stability, and reliability. For this purpose, a magnetic strain-proportional reference field is introduced. The optical read-out is realized by the measurement of the Bragg-wavelength shift.
The ratio of resulting strain and exciting magnetic reference field should be constant given that the sensor is in proper function.
In principle, the magnetostrictive coating around the FBG should also work as on-line magnetic field sensor and other applications in material science. One of these applications is the in-situ monitoring of ECD processes as the deposition of the ECD NiFe-layer on the FBG revealed. Challenges are the monitoring of temperature, deposition
stages/thickness, and resulting mechanical stress under given plating conditions. Monitoring problems can be solved by applying a pre-coated FBG to the electrolytic process as the shift of the Bragg wavelength is affected by both the temperature of the electrolyte near the substrate and the stress formation in the growing layer. The experimental FBG set-up and the quantitative determination of temperature- and stress-related strain are described for a nickeliron
electrolyte. The in-situ measurement of Bragg wavelength shifts of a pre-coated FBG during electrochemical deposition allows a detailed analysis of stress states due to changes in the growth morphology of the layer. The separation of mechanical and thermal contributions to this shift provides information on the individual Deposition processes in terms of a process fingerprint.
Das Vorhaben ZENSUS beschäftigt sich mit der Erstellung eines Normenentwurfs bzw. einer normen-konformen Technischen Spezifikation für die Zentrifugen-basierte Prüfung der Klebfestigkeit von Stumpfklebungen. Das umfasst auch umfangreiche Validierungsversuche, um mögliche Unterschiede zwischen Kraft-gesteuerter (Zentrifuge) und Weg-gesteuerter (Zugprüfmaschine) bzw. ggf. dazu korrelierte Materialabhängigkeiten mit ihren Auswirkungen auf SOPs zu identifizieren. Die Zentri-fugen-basierte Mehr-Proben-Prüfung von bis zu 8 Klebverbunden wird im Weiteren mit CAT-Technologie („Centrifugal Adhesion Testing“) abgekürzt.
Im Vorhaben SNELLIUS wurden in enger Zusammenarbeit der BAM mit den Firmen Accurion und SENTECH Instruments aufbauend auf der Norm DIN 50989-1 „Ellipsometrie - Teil 1: Grundlagen; Ellipsometry – Part 1: Principles“ insgesamt fünf Normenentwürfe erarbeitet, die fünf Modell-basierten Anwendungsfällen der Ellipsometrie entsprechen. Unter Berücksichtigung des neuartigen Modell-basierten Normungskonzepts wurde in den Normenentwürfen erstmals eine GUM- und DIN EN ISO/IEC 17025:2018 konforme Bestimmung bzw. Abschätzung der Messunsicherheit umgesetzt. Dies erforderte neben der textlichen Erstellung auch umfangreiche experimentelle Arbeiten bei den Firmen, Vergleichsversuche und komplementäre Modell- und Datenevaluierungen, da sowohl die verwendete ellipsometrische Hardware (unterschiedliche ellipsometrische Funktionsprinzipien) als auch die ellipsometrische Software (Modell-Randbedingungen, Fitalgorithmus) firmenspezifisch zum Teil sehr unterschiedlich sind. Hierbei mussten in einem Konsensprozess Lösungen gefunden werden, die die beiden deutschen Ellipsometer-Anbieter Accurion (Imaging-Ellipsometrie) und SENTECH Instruments (Mapping Ellipsometrie) gleichermaßen akzeptieren konnten und die zudem einen Transfer auf die Internationale Ebene (ISO Norm) ermöglichen, also vom Grundsatz her auch auf weitere Ellipsometerhersteller wie (J. A. Woollam Co., USA; SEMILAB, Ungarn; HORIBA, Japan) mit wieder anderen ellipsometrischen Funktionsprinzipien, Hard- und Softwarelösungen anwendbar sind. Die weitgehende Unabhängigkeit von ellipsometrischen Funktionsprinzipien, Hard- und Softwarelösungen wurde dadurch erreicht, dass normativ festgelegt wurde, dass die ellipsometrischen Größen PSI und DELTA im Sinne von DIN ENISO/IEC 17025 als Rohdaten fungieren.
Single Femtosecond Laser-Pulse-Induced Superficial Amorphization and Re-Crystallization of Silicon
(2021)
Superficial amorphization and re-crystallization of silicon in <111> and <100> orientation after irradiation by femtosecond laser pulses (790 nm, 30 fs) are studied using optical imaging and transmission electron microscopy. Spectroscopic imaging ellipsometry (SIE) allows fast data acquisition at multiple wavelengths and provides experimental data for calculating nanometric amorphous layer thickness profiles with micrometric lateral resolution based on a thin-film layer model. For a radially Gaussian laser beam and at moderate peak fluences above the melting and below the ablation thresholds, laterally parabolic amorphous layer profiles with maximum thicknesses of several tens of nanometers were quantitatively attained. The accuracy of the calculations is verified experimentally by high-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (STEM-EDX). Along with topographic information obtained by atomic force microscopy (AFM), a comprehensive picture of the superficial re-solidification of silicon after local melting by femtosecond laser pulses is drawn.
MISTRAL-Müller-Matrix-basierte Identifizierung von Inhomogenitäten und strukturellen Anomalien
(2020)
Mit abbildender Ellipsometrie (imaging ellipsometry: IE) können Nanometer-Beschichtungen/ Degradationen visualisiert und bezüglich Brechungsindex n, Extinktionskoeffizient k und Schichtdicke d charakterisiert werden. Materialseitig werden lokal Homogenität und Isotropie innerhalb eines/mehrerer Bildpunkte (field of analysis: FOA) und messtechnisch global die Ebenheit der Proben bezüglich aller Bildpunkte des Messfeldes vorausgesetzt. Für die Müller-Matrix-basierte abbildende Ellipsometrie (MM-IE), die den optischen Response anisotroper Materialien in jedem Bildpunkt über die bis zu 16 Müller-Matrix-Elemente erfasst, ist dies von besonderer Relevanz. Reale Substrate sind aber oft nicht eben, können lokal Noppen/Mulden (im FOA) aufweisen oder sind global konvex/ konkav im möglichen Messfeld (field of view: FOV) gekrümmt. Diese lokalen/globalen strukturellen Anomalien des Substrats werden schon für die IE messtechnisch/modellseitig oft nicht beherrscht und sind für die MM-IE in der Wirkung auf die MM-Elemente unbekannt. Diese Defizite sollen messtechnisch bzw. modellmäßig behoben und somit die Messung lokal/global gekrümmter Oberflächen ermöglicht werden (MM-CSIE, CS curved surface).
Sufficient adhesion/tensile strength are basic requirements for any coating/composite material. For coatings, adhesive strength in N/mm2 is of Major interest for various applications such as decorative and water-repellent coatings on wood (paints and varnishes), optical coatings on glass and polymers (reflectors and filters), electrical coatings on semiconductors, glass and polymers (conducting and bondable layers), mechanical coatings on metals and polymers (wear-reduction, scratch-resistance) and adhesion-promoting layers. For composite materials, tensile strength in N/mm2 is also a key quantity for carbon fiber reinforced composites (CFC), laminates and adhesive-bonded joints. Centrifugal adhesion testing (CAT) transfers the single-sample tensile test from a tensile or universal testing machine into an analytical centrifuge as multiple-sample test of up to eight test pieces. The one-sided sample support instead of a two-sided sample clamping and the absence of mounting- and testing-correlated shear forces provides fast and reliable results both for adhesive strength and bonding strength by means of bonded test stamps. For bonding strength, the evaluation of failure pattern from microscopic inspection is required in order to determine the failure pattern according to ISO 10365 such as adhesive failure (AF), delamination failure (DF) and cohesive failure (CF). Hence, one test run by CAT-technology provides either statistics or ranking of up to eight samples at once. For adhesive strength of coatings, a variety of examples is discussed such as ALD-Al203 layers as adhesion promoters, evaporated Ag-layers on N-BK7 glass, sputtered Cr- and Al-layers on Borofloat 33 glass, evaporated Au-films on N-BK7 glass and sputtered SiO2 -layers on CR39 Polymer. Provided adhesive or bonding strength are high enough, the substrate or the joining part may also fail.
The quantitative determination of adhesion and cohesion properties is a key requirement for adhesive-bonded joints and coated components in both R&D and Quality assurance. Because of the huge variety of layer/substrate Systems in terms of materials and large thickness range, adhesion tests display the same diversity as layer/substrate systems. There are only two tensile testing procedures available, that determine adhesive strength in terms of force per area (N/mm²), the single-sample pull-off test in a tensile testing machine and the multiple-sample-test using the Centrifugal Adhesion Testing (CAT) Technology.
The CAT Technology is a testing method which uses centrifugal force as tensile testing force in a multiple-sample arrangement within a drum rotor of a Desktop centrifuge. Hence, the adhesive/bonding strength A/B can be determined on a statistical basis under identical testing conditions for up to eight samples.
A variety of examples for bonding strength of adhesives, adhesive strength of coatings and compound strength of composite materials is discussed such as metalto-metal and glass-to-metal bonding, sputtered SiO2-layers on CR39 Polymer and carbon fiber reinforced polymer.
Phage display biopanning with Illumina next-generation sequencing (NGS) is applied to reveal insights into peptide-based adhesion domains for polypropylene (PP). One biopanning round followed by NGS selects robust PP-binding peptides that are not evident by Sanger sequencing. NGS provides a significant statistical base that enables motif analysis, statistics on positional residue depletion/enrichment, and data analysis to suppress false-positive sequences from amplification bias. The selected sequences are employed as water-based primers for PP-metal adhesion to condition PP surfaces and increase adhesive strength by 100% relative to nonprimed PP.
Der Vortrag widmet sich der „Zentrifugentechnologie zur statistischen Untersuchung von Stumpfklebungen“ und beschreibt drei wesentlich verschiedene Realsysteme (Fügefläche 1/Klebstoff/ Fügefläche 2), um die Statistik ZPM (wiederholte Ein-Proben-Prüfung) vs. CAT (Mehr-Proben-Prüfung) zu vergleichen. Dazu wurden drei unterschiedliche Klebstoff-klassen mit typischen Fügeteilmaterialkombinationen ausgewählt und in einem Vorversuch mit jeweils 3 unterschiedlichen Prüfgeschwindigkeiten sowohl im Weg-geregelten als auch Kraft-geregelten Mode beansprucht. Die Ergebnisse ZPM vs. CAT und Kraft- vs. Weg-Regelung des Vorversuches zeigten keinerlei Unterschiede auf. Im Ergebnis wurde ein Ringversuch im Kraft-geregelten Mode (6xZPM vs. 8xCAT) für ein Referenzsystem durchgeführt, der nachwies, dass die CAT-Technologie statistisch relevante Prüfergebnisse zur Klebfestigkeit bereitstellt. Es zeigte sich, dass für zwei ZPM-Teilnehmer im Vertrauensbereich 99% statistisch signifikant etwas kleinere Werte der Klebfestigkeit bestimmt wurden, was auf geringfügige Abweichungen von der axialen Ausrichtung des eingespannten Prüflings bei der Ein-Proben-ZPM-Zugprüfung zurückgeführt wird.
Der Mangel an Anwendungsrichtlinien und Validierungsverfahren für struktur-eingebettete faseroptische Dehnungssensoren, insbesondere auf Faser-Bragg-Gitter (FBG)-Basis, führte bislang dazu, dass diese Sensoren trotz ihrer hervorragenden Eigenschaften im Bereich der kommerziellen Material- und Strukturüberwachung nur in geringem Umfange eingesetzt wurden. Fragen zur Degradation der Sensoren unter Beanspruchung, Alterung durch klimatische Einflüsse und Enthaftung infolge Belastung der Struktur konnten bisher nur theoretisch simuliert oder anhand exemplarischer Proben für einzelne einflussnehmende Parameter im Labor untersucht werden. Die Erfassung des Sensorverhaltens im Bauteil unter komplexen Umwelteinflüssen während des Bauteilbetriebes, um damit eine Aussage zur Zuverlässigkeit der Sensormessdaten zu gewinnen, war bisher nicht möglich.
Im Forschungsprojekt FAMOS² wurde deshalb von 2014 bis 2018 die Realisierung eines Autodiagnoseverfahrens für faseroptische Dehnungssensoren erarbeitet, um die Funktionszuverlässigkeit und Langzeitstabilität der Sensoren während des Bauteilbetriebes innerhalb einer Bauteilstruktur bewerten zu können. Im Rahmen des Forschungsprojektes wurde gezeigt, dass ein FBG-Sensor mit einer speziell angepassten magnetostriktiven Schicht magnetisch so angeregt werden kann, dass mit einer zugeschnittenen Messmethodik zu jedem Zeitpunkt eine Bewertung der Sensorzuverlässigkeit unter Betriebsbedingungen möglich ist. Die auf den Sensor aufgebrachte magnetostriktive Schicht erzeugt bei Anregung mit einem passenden Magnetfeld eine gepulste, synthetische Dehnung. Diese Dehnung steht in einem definierten Verhältnis zum anregenden Magnetfeld und wird optisch über die Verschiebung der Bragg-Wellenlänge ausgelesen. Die Konstanz dieses Verhältnisses stellt dann ein Maß für die korrekte Funktionsfähigkeit des Sensors dar. Das Beschichtungs-verfahren, das magnetische Anregungs- und optische Ausleseverfahren, wie auch die Validierung des Sensors unter Berücksichtigung faseroptischer Effekte wurden während des Projekts konzeptionell entwickelt, aufgebaut und charakterisiert. Qualitativ kann mit diesem Verfahren zunächst eine Gut-/Schlecht-Beurteilung des Sensors vorgenommen werden. Perspektivisch bietet das Verfahren jedoch auch die Möglichkeit, verschiedene Versagensmechanismen bestimmen und klassifizieren zu können. Es zeichnete sich schon während des Projektverlaufs ab, dass sich aus den erzielten Ergebnissen über das Autodiagnoseverfahren hinaus weitere Anwendungsmöglichkeiten für den Einsatz des kombinierten magnetostriktiv-faseroptischen Sensorprinzips, beispielsweise als reiner Magnetfeldsensor, ergeben.
Nach Abschluss dieses Forschungsprojekts besteht nun die Möglichkeit, den Funktionszustand faseroptischer Dehnungssensoren jederzeit unabhängig von Alter, Belastung oder Kenntnis eines Referenzzustands zu einem bestimmten Zeitpunkt bestimmen zu können. Aufbauend auf diesen Ergebnissen können weiterführende Forschungen die Messmethodik vertiefend charakterisieren und weitere Anwendungsfälle erschließen.
Im Fokus des Vorhabens steht das mit dem Innovationspreis Berlin-Brandenburg 2012 ausgezeichnete Mehr-Proben-Prüfverfahren zur Festigkeitsprüfung unter Verwendung einer analytischen Zentrifuge mit dem Ziel des Einsatzes in der Qualitätssicherung. Nachdem im MNPQ-Projekt QUO VADIS die grundsätzliche Anwendbarkeit der Zentrifugentechnologie auf Beanspruchungen auf Zug (Kleb-, Haft- und Verbundfestigkeit) nachgewiesen worden war, wurden im Vorhaben QUO VADIS PLUS folgende erweiterte Prüfszenarien und technische Weiterentwicklungen etabliert: 1. Beanspruchung auf Druck (Härte von Materialien, Kompressibilität von Schäumen, Kompaktierbarkeit von Pulvern), 2. Erweiterung der Beanspruchung auf Zug (Kombination von Normal- und Lateralkräften), 3. Erweiterung auf die Bewertung plasto-elastischenn Materialverhaltens, 4. Vermeidung von Schockwellen im Hochlastbereich
Das Fügeverfahren Kleben bietet viele Vorteile wie z.B. das Verbinden schwieriger Materialklassen, geringe thermische Belastung (Strukturveränderung/-schwächung) der Fügepartner und eine Lastverteilung über den gesamten Fügebereich. Die Auswahl an verfügbaren Klebstoffen und Vorbehandlungsoptionen ist dabei ebenfalls vielfältig. Einige Polymere weisen darüber hinaus Eigenschaften auf, die eine Herstellung von festen und dauerhaft beanspruchbaren Klebverbindungen erschweren. Mittels Oberflächenbehandlung, z.B. durch Plasmafeinreinigung bzw. –aktivierung, können die Grenzflächern solcher Polymere - bezogen auf die Eignung als Fügeteilpartner – optimiert werden. Schnelle Prüfverfahren zur Ermittlung von Verbundeigenschaften sind somit erforderlich.
Das Messprinzip Centrifugal Adhesion Testing Technologie verwendet die radial gerichtete Zentrifugalkraft als Belastungsgröße des zu testenden Verbunds, die durch Variation der Drehzahl gesteuert wird. Bei Erreichen der kritischen Beanspruchung trennt sich ein aufgeklebter Prüfstempel vom Substrat. Zeitgleich wird ein positionsbezogenes IR-Signal aus dem drehenden Rotor an das Basisgerät gesendet und zusammen mit der Drehzahl an die PC-Software übertragen. Für jede Probe wird die Bruchkraft berechnet und in Echtzeit angezeigt. Der Adhesion Analyser LUMiFrac® untersucht bis zu acht Prüfkörper unter identischen Bedingungen. Das neue Messprinzip erfüllt die Anforderungen von DIN EN 15870, DIN EN 14869-2, ISO 4624 sowie DIN EN 13144.
Die Multiprobentestung ermöglicht schnelle Charakterisierungen von Klebverbindungen. So kann der Effekt einer Plasmabehandlung von Bauteilen auf die Verbundfestigkeit zeitsparend bestimmt werden. Die gezielte Veränderung unterschiedlicher Plasma-Parameter, wie beispielsweise, die Plasmazusammensetzung, der Abstand vom Plasmabrenner zur Oberfläche oder die Verweildauer unter dem Brenner, beeinflußt die Festigkeit des Klebsystems und ist dem LUMiFrac direkt quantifizierbar.
Neben der Festigkeitsbestimmung von Klebverbindungen ist die Haftung von Schichtsystemen ein wichtiger Anwendungsbereich. Ergebnisse für Zug- und Scherbeanspruchung, realisiert mit unterschiedlichen Prüfkörper-Geometrien, werden vorgestellt. Ferner werden verschiedene festigkeitsbeeinflussende Faktoren, wie Prüfgeschwindigkeit oder Substratverformung bei Beanspruchung untersucht
For the vast majority of ellipsometric measurements, the application of planar substrates is mandatory and requires a proper sample alignment prior to the measurement. Here, the authors present a generalized approach of how to extract the isotropic ellipsometric sample parameters from an imaging Mueller-matrix measurement even if the sample is significantly misaligned. They validate the method by layer-thickness calculations based on imaging Mueller-matrix measurements of flat crystalline silicon samples that were misaligned on purpose. Furthermore, they also exploit this method’s capabilities to perform spatially resolved layer-thickness measurements of a single-layer indium-tin-oxide coating on a fused-silica microlens without the need of realignment or repositioning of the sample during the measurement.
The authors describe and interpret curvature-related changes to the ellipsometric readout. As model system for a concave curvature, a set of three spherical microscopic indents in silicon (100) of different sizes was prepared by instrumented indentation testing using a spherical indenter. For reference, these samples were characterized by AFM to reveal the topography of each structure. The concavelike indents were analyzed by Mueller-Matrix imaging ellipsometry to extract lateral intensity images of 12 elements of the Mueller-Matrix. As a result of the detailed analysis of the image elements m22, m23, and m14, it was possible to correlate intensity changes and symmetry properties to depolarization and cross polarization induced by the edge threshold and the curved surface of the indent.