6.1 Oberflächen- und Dünnschichtanalyse
Filtern
Dokumenttyp
- Vortrag (202)
- Zeitschriftenartikel (196)
- Posterpräsentation (87)
- Forschungsdatensatz (26)
- Sonstiges (16)
- Beitrag zu einem Sammelband (10)
- Beitrag zu einem Tagungsband (7)
- Forschungsbericht (7)
- Handbuch (4)
- Sammelband (Herausgeberschaft für den kompletten Band) (2)
Sprache
- Englisch (562) (entfernen)
Schlagworte
- Nanoparticles (126)
- XPS (91)
- Electron microscopy (57)
- SEM (48)
- VAMAS (39)
- X-ray photoelectron spectroscopy (32)
- HAXPES (31)
- Particle size distribution (30)
- ToF-SIMS (27)
- NAP-XPS (23)
- Standardisation (20)
- Nanomaterials (19)
- Thin films (18)
- Biofilms (17)
- EDS (17)
- Inter-laboratory comparison (17)
- Graphene (15)
- Spectroscopic ellipsometry (15)
- Core-shell nanoparticles (14)
- EPMA (14)
- Reference materials (14)
- NanoSolveIT (13)
- Sample preparation (13)
- AFM (12)
- Interlaboratory comparison (12)
- Nanomaterial (12)
- SAXS (12)
- TiO2 (12)
- Traceability (12)
- E. coli (11)
- EBSD (11)
- Ellipsometry (11)
- Functionalized graphene (10)
- NEXAFS (10)
- Reference material (10)
- Standardization (10)
- Laser-induced periodic surface structures (LIPSS) (9)
- Size (9)
- Electron probe microanalysis (EPMA) (8)
- Imaging (8)
- Metrology (8)
- Oxygen evolution reaction (8)
- Roughness (8)
- Base damage (7)
- Base loss (7)
- Boehmite (7)
- Core-shell particles (7)
- DNA (7)
- Geant4 (7)
- LEE (7)
- Polymers (7)
- ROS (7)
- Reactive oxygen species (7)
- SIMS (7)
- Surface chemistry (7)
- TOPAS (7)
- Titanium dioxide (7)
- Alginate (6)
- Core-shell (6)
- DNA radiation damage (6)
- Dissociative electron attachment (DEA) (6)
- Dosimetry (6)
- Electrochemistry (6)
- Fluorescence (6)
- Geant4-DNA (6)
- Hydrated DNA (6)
- Hydration shell (6)
- Hydrogen (6)
- Hydroxyl radical (6)
- Ionization (6)
- Low energy electrons (6)
- Microdosimetry (6)
- Nanocomposite (6)
- Near ambient pressure xray photo electron spectroscopy (6)
- OH radical (6)
- PES (6)
- Polydopamine (6)
- Prehydrated electron (6)
- Quantum dots (6)
- Radiation damage (6)
- Risk assessment (6)
- Shape (6)
- Single-strand break (SSB) (6)
- Surface chemical analysis (6)
- TOPAS-nbio (6)
- Test material (6)
- Titania nanoparticles (6)
- Titanium oxide (6)
- White light interference microscopy (6)
- X-ray spectroscopy (6)
- Xray photo electron spectrocopy (6)
- Bacteria (5)
- Data (5)
- Direct damage (5)
- Dissociative electron transfer (DET) (5)
- ESCA (5)
- Elemental composition (5)
- FIB (5)
- Fe-Ni (5)
- Hydrated electron (5)
- ISO (5)
- ISO/TC 202 (5)
- Image analysis (5)
- Image processing (5)
- Imaging ellipsometry (5)
- Indirect damage (5)
- Iridium oxide (5)
- Mesoporous iridium oxide films (5)
- Microbeam analysis (5)
- Micropatterning (5)
- Microplastic (5)
- Microplastics (5)
- Net-ionization reaction (5)
- PS (5)
- PTFE (5)
- Quantification (5)
- Quasi-direct damage (5)
- Radiation therapy (5)
- Radical (5)
- Regulation (5)
- SEM/EDS (5)
- STXM (5)
- Si-Ge (5)
- SiO2 (5)
- Surface analysis (5)
- Surface functionalization (5)
- TEM (5)
- Thin film analysis (5)
- VSSA (5)
- X-ray Photoelectron Spectroscopy (5)
- X-ray Photoelectron Spectroscopy (XPS) (5)
- nPSize (5)
- AISI 304L (4)
- Advanced materials (4)
- Cancer treatment (4)
- Catalysis (4)
- Cycloalyphatic epoxy oligosiloxane (4)
- Deuterium (4)
- Double-strand break (DSB) (4)
- EC4SafeNano (4)
- Electron probe microanalysis (4)
- FeNi (4)
- ILC (4)
- ISO/TC 229 (4)
- Image segmentation (4)
- Imaging XPS (4)
- Ionic liquid (4)
- Knowledge Readiness Level (4)
- Microbeam Analysis (4)
- Multi-sample analysis (4)
- Nano (4)
- Nano@BAM (4)
- NanoDefine (4)
- Nanomaterial classification (4)
- Nanoparticle (4)
- Nanoparticle concentration (4)
- Nanotechnology (4)
- Non-destructive operando analysis (4)
- Oxidation (4)
- Particle size (4)
- Performance check (4)
- Protein (4)
- Quality assurance (4)
- Reproducibility (4)
- SEM/EDX (4)
- Scanning electron microscopy (4)
- SiGe (4)
- Single-stranded DNA-binding proteins (4)
- Standards (4)
- Synchrotron radiation (4)
- Thickness (4)
- Transmission function (4)
- Amperometry (3)
- Auger Electron Spectroscopy (3)
- Austenitic stainless steel (3)
- BAM reference data (3)
- Coating (3)
- Correlative imaging (3)
- Corrosion (3)
- DEA (3)
- DET (3)
- Data-fusion (3)
- EDX (3)
- Electro catalyst (3)
- Electrocatalysis (3)
- Energy deposit (3)
- Energy dispersive X-ray spectroscopy (3)
- Epoxy (3)
- European Centre (3)
- Femtosecond laser (3)
- Fluoride (3)
- G5P (3)
- Gold (3)
- Graphene oxide (3)
- HKUST-1 (3)
- Hard X-ray photoelectron spectroscopy (HAXPES) (3)
- Hard-energy X-ray photoelectron spectroscopy (3)
- Hybrid metrology (3)
- ISO/TC 229 Nanotechnologies (3)
- Immunoassay (3)
- Interlaboratory Comparisons (3)
- Iodine (3)
- Ionisation (3)
- Iridium oxide films (3)
- Iron oxide nanoparticles (3)
- Laser ablation in liquid (3)
- MCS (3)
- MamaLoCA (3)
- Mesoporous materials (3)
- Method (3)
- Microanalysis (3)
- Nanoelectronics (3)
- Nanoplastics (3)
- Nanosafety (3)
- Non-spherical shape (3)
- OER (3)
- PCA (3)
- Particle (3)
- Particle scattering (3)
- Photocatalysis (3)
- Polymer 3R (3)
- Preparation (3)
- Presolvated electron (3)
- Quantum yield (3)
- Radiolysis (3)
- Radiotherapy (3)
- Reference data (3)
- Simulation (3)
- Spectroscopy (3)
- Stability (3)
- Steel (3)
- Surfaces (3)
- Synthesis (3)
- TED-GC/MS (3)
- Thin Films (3)
- Thin film metrology (3)
- Titania (3)
- Transmission Kikuchi Diffraction (TKD) (3)
- Transmission electron microscopy (3)
- Two-photon polymerisation (3)
- Uncertainties (3)
- X-ray spectrometer (3)
- XRF (3)
- Xray (3)
- Zirconium (3)
- µ-XRF (3)
- 2D Materials (2)
- 2D materials (2)
- 3D (2)
- 3D nano SIMS (2)
- ACEnano (2)
- AES (2)
- ATR-FTIR spectroscopy (2)
- Agarose (2)
- Aging (2)
- Anatase (2)
- Atomic force microscopy (2)
- Atomic layer deposition (2)
- Auger Electron Spectroscopy (AES) (2)
- Automated image analysis (2)
- Automatisation (2)
- Biosensors (2)
- Bisphenol A (2)
- CEN/TC 352 Nanotechnologies (2)
- Cancer therapy (2)
- Case studies (2)
- Catalysts (2)
- Characterisation (2)
- Characterization (2)
- Chemical analysis (2)
- Chemical composition (2)
- Concentration (2)
- Convolutional neural networks (2)
- Copper (2)
- Correlative analysis (2)
- Cylic Voltammetry (2)
- DSB (2)
- Decision support (2)
- Defects (2)
- Definition of nanomaterial (2)
- Depth profiling (2)
- Dry DNA (2)
- Duplex stainless steel (2)
- EDS-TM002 (2)
- EU FP7 project NanoValid (2)
- Ectrocatalysis (2)
- Electron Microscopy (2)
- Electron Probe Microanalysis (2)
- Electron spectroscopy (2)
- Epitaxially grown 4H-SiC layers (2)
- Fe3O4 (2)
- FeNi-Oxide NPs (2)
- Ferrihydrite (2)
- Field of View (2)
- Film thickness (2)
- Fullerene (2)
- Graphene oxide flakes (2)
- Graphene powder (2)
- Graphene related 2D materials (2)
- Hard x-ray photoelectron spectroscopy (2)
- Hydrated electrons (2)
- Hydrothermal synthesis (2)
- ICP-OES (2)
- Inter-laboratory comparisons (2)
- Iridium-titanium mixed oxides (2)
- Iron oxide (2)
- LDX (2)
- Lanthanide (2)
- Lateral resolution (2)
- Layer-by-layer deposition (2)
- Lifetime (2)
- MOF (2)
- Machine learning (2)
- Mass spectrometry (2)
- Mesoporous thin films (2)
- Metal organic frameworks (2)
- Micro- and nanoplastics (2)
- Microprinting (2)
- Microscopy (2)
- Microstructure (2)
- Modelling (2)
- Molecular sieves (2)
- Multiphoton lithography (2)
- Mussel-inspired adhesives (2)
- Nano-safety (2)
- NanoSIMS (2)
- Nanoparticle characterization (2)
- Nanoparticle size distribution (2)
- Nanorisk (2)
- Nanostructures (2)
- Neural networks (2)
- Non-classical crystallization theory (2)
- Particle characterisation (2)
- Particle morphology (2)
- Particle number concentration (2)
- Particle size and shape distribution (2)
- Passive film (2)
- Phosphates (2)
- Photocuring (2)
- Photooxidation (2)
- Plasma (2)
- Polyethylene (2)
- Polyethylene Terephtalate (2)
- Polyethylene glycol (2)
- Polyglycerol (2)
- Porosity (2)
- Porous thin films (2)
- Pre-standardisation (2)
- Proteins (2)
- Quantum dot (2)
- Raman spectroscopy (2)
- Raman-spectroscopy (2)
- Reference Material (2)
- SSB (2)
- Safe-by-design (2)
- Secondary ion mass spectrometry (2)
- Shape-controlled (2)
- Silica nanoparticles (2)
- Size distribution (2)
- Small Area XPS (2)
- Small-angle X-ray scattering (2)
- Small-area XPS (2)
- Small-spot XPS (2)
- Spectroscopic Ellipsometry (2)
- Spectroscopic and imaging ellipsometry (2)
- Stainless steel (2)
- Stratagem (2)
- Surface Analysis (2)
- Surface analytics (2)
- Surface charge (2)
- Surface morphology (2)
- Surface science (2)
- TKD (2)
- Ti6Al4V alloy (2)
- Time-of-flight secondary ion mass spectrometry (ToF-SIMS) (2)
- Transition metals (2)
- Transparent Conductive Oxides (2)
- Tribology (2)
- Tungsten (2)
- Ultrafast laser processing (2)
- Ultrashort laser pulses (2)
- Upconversion (2)
- Virus inhibition (2)
- Water (2)
- X-ray production efficiency (2)
- X-rays (2)
- thin film analysis (2)
- (Quantitative) Structure-Active Relationships (1)
- (ter-)pyridineterminated self-assembled monolayer (1)
- 1-propyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl)imide (1)
- 2D (1)
- 2D flakes (1)
- 2D nanomaterial (1)
- 3D image analysis (1)
- 3D printing (1)
- 4H–SiC (1)
- AEROSIL® OX50 (1)
- AI tool (1)
- Absorption spectrometry (1)
- Abwasser (1)
- Acidic oxygen evolution reaction (1)
- Adsorbed Layer (1)
- Advanced Materials (1)
- Advanced material (1)
- Advanced optics (1)
- AgInS (1)
- AgInS2 (1)
- Aged particles (1)
- Ageing (1)
- Al2O3 thin films (1)
- AlOOH (1)
- Alkali-silica reaction (1)
- Alloy 31 (1)
- Amorphous phases (1)
- Amphiphilicity (1)
- Analysis area measurements (1)
- Analytical methods (1)
- Analytical services (1)
- Anomalous Small Angle X-ray Scattering (1)
- Antibacterial (1)
- Antibacterial surface coatings (1)
- Antibiotic delivery (1)
- Antibiotic release (1)
- Antibiotics (1)
- Antifouling (1)
- Antifouling surface coatings (1)
- Antigen testing (1)
- Antimicrobial titanium coating (1)
- Antiviral activity (1)
- Aqueous synthesis (1)
- Argon gas cluster ion sputtering (1)
- Artefact (1)
- Article concentration (1)
- Artificial Intelligence (1)
- Artificial intelligence (1)
- Atmospheric conditions (1)
- Atomic Force Microscopy (1)
- Atomic fraction (1)
- Au Nanoparticles (1)
- Au-nanocubes (1)
- Auger electron spectroscopy (1)
- Auger-electron spectroscopy (AES) (1)
- Austenitic steel (1)
- Automated Image Analysis (1)
- Automation (1)
- B10 exposure (1)
- BADGER film (1)
- BET (1)
- BNP (1)
- BSA (1)
- Bacteria repellent surfaces (1)
- Bacterial adhesion tests (1)
- Bacterial attachment (1)
- Bacterial lipopolysaccharides (1)
- BadgerFilm (1)
- Batch analysis (1)
- Bead-based assay (1)
- Benchmarking (1)
- Bimodal (1)
- Bimodal size distribution (1)
- Binary zinc alloys (1)
- Bio sensing device (1)
- Bio-orthogonal chemistry (1)
- Bio-weathering (1)
- Biochip (1)
- Biofilm (1)
- Biofuels (1)
- Biointerfaces (1)
- Biomaterials (1)
- Biomimicry (1)
- Biopolymers (1)
- Bipyramid (1)
- Bismuth titanates (1)
- Black fungi (1)
- Black phosphorus (1)
- Boehmite nanoparticles (1)
- Bone (1)
- Boronic acid (1)
- Boronic acid-functionalized 2D MoS2 (1)
- Bovine serum albumin (1)
- Brunauer-Emmett-Teller (1)
- Bulk metallic glasses (1)
- C7H15N2O4P (1)
- CCQM (Consultative Committee for Amount of Substance) (1)
- CEN (1)
- CEO (1)
- CIGS (1)
- CO2 (1)
- CUSP (1)
- Calcium monofluoride (1)
- Calcium silicate hydrate (1)
- Calibration (1)
- Cancer (1)
- Cancer therapy (1)
- Carbon Nanotubes (1)
- Carbon dioxide (1)
- Carbon nanoparticles (1)
- Carbon nanotubes (1)
- Carbon storage (1)
- Catalogue of Services (CoS) (1)
- Catalogue of services (1)
- Categorisation scheme (1)
- Cationic photocuring (1)
- Ce0.1Zr0.9O2 nanoparticles (1)
- Ce0.5Zr0.5O2 nanoparticles (1)
- Ce0.75Zr0.25O2 nanoparticles (1)
- Ce0.9Zr0.1O2 (1)
- CeO2 nanoparticles (1)
- CeO2/Co3O4 (1)
- Cell sheet fabrication (1)
- Cell-envelope (1)
- Cement hydration (1)
- Ceramic (1)
- Cerium oxide (1)
- Certified Referencematerial (1)
- Certified reference materials (1)
- Certified reference nanomaterials (1)
- Change in tensile properties (1)
- Characterization method (1)
- Characterization methods (1)
- Charge (1)
- Chemical analyses (1)
- Chemistry (1)
- Chemometric analysis (1)
- Chemotherapy (1)
- Classification (1)
- Cleaning (1)
- Click chemistry (1)
- Co0.75Fe2.25O4 nanoparticles (1)
- Co2.25Fe0.75O4 nanoparticles (1)
- Co3O4 nanoparticles (1)
- Coatings (1)
- Coherent Fourier scatterometry (1)
- Comparability (1)
- Comparability of Measurement Results (1)
- Comparison (1)
- Complementary methodology and metrology (1)
- Complementary methods (1)
- Complex-shape (1)
- Composites (1)
- Composition (1)
- Compound semiconductors (1)
- Computed tomography (1)
- Conditioning films (1)
- Controlled morphology (1)
- Controlled periodic illumination (1)
- Controlled-shape (1)
- Copper alloy (1)
- Coprecipitation (1)
- Core-shell nanoparticle (1)
- Core-shell nanoparticle (CSNP) (1)
- Core-shell structures (1)
- Core/shell nanoparticle (1)
- Core–shell particles (1)
- Core−shell particles (1)
- Correlative Imaging (1)
- Correlative ex-situ ellipsometric analysis (1)
- Corrosion testing (1)
- Covalend functionalization (1)
- Covalent functionalization (1)
- Covalent interactions (1)
- Cross-sectioning (1)
- Crosslinking density (1)
- Cryo XPS (1)
- Cryo milling (1)
- CuNPs (1)
- CuO nanoparticles (1)
- Cubical Iron Oxide (1)
- Cubical shape (1)
- Curing (1)
- Cyclic voltammetry (1)
- Cycloaliphatic epoxy oligosiloxane (1)
- Cyclometalated iridium (III) complexes (1)
- Cytotoxicity (1)
- DFT (1)
- DSC (1)
- DSM 5009 (1)
- DSS (1)
- Damage (1)
- Data Management (1)
- Data correlation (1)
- Data fusion (1)
- Data readiness level (1)
- Definition (1)
- Dendritic polyglycerol (1)
- Depth Profiles and Images (1)
- Depth information (1)
- Depth-profiling (1)
- Dielectric Spectroscopy (1)
- Diffraction (1)
- Diffusion/diffusivity (1)
- Dispersion of nano materials (1)
- Dodecanethiol (1)
- Doping (1)
- Double-strand break (1)
- Drywood termite (1)
- Duplex stainless steels (1)
- Dynamic behavior (1)
- EC definition of a nanomaterial (1)
- EC definition of nanomaterial (1)
- EC nanomaterial definition (1)
- EDS Spectrometer Test (1)
- EDS X-ray spectrometer (1)
- EDS performance check (1)
- EDS-TM001 (1)
- EMPIR (1)
- EMPIR nPSize (1)
- EPMA (Electron Probe Microanalysis) (1)
- ER-XPS (1)
- ESCA/XPS (1)
- ESMA (1)
- ESR (1)
- EU (1)
- EU definition (1)
- EU definition of nanomaterial (1)
- Electrical Properties (1)
- Electrical properties (1)
- Electrical thin layers (1)
- Electro catalytic water splitting (1)
- Electrocatalytic Water Splitting (1)
- Electrochemical Degradation (1)
- Electrochemical catalysts (1)
- Electrochemical immunosensor (1)
- Electrochemical sensing (1)
- Electrolysis (1)
- Electron Probe Microanalysis (EPMA) (1)
- Electron probe X-ray microanalysis (EPMA) (1)
- Electron probe microanallysis (EPMA) (1)
- Electrospray (1)
- Electrospray deposition (1)
- Electrospun nanocomposite fiber (1)
- Elektronenmikroskopie (1)
- Elementzusammensetzung (1)
- Ellipsometric operando investigation (1)
- Ellipsometric porosimetry (1)
- Endocrine disruptor (1)
- Energy dependent XPS (1)
- Energy materials (1)
- Epoxy conversion degree (1)
- Epoxy nanocomposites (1)
- Escherichia coli (1)
- Estrogenic activity of plastic nanoparticles (1)
- Expert system (1)
- Extracellular polymeric substances (1)
- F- doping (1)
- FAIRification (1)
- FKM polymer (1)
- FTIR (1)
- Fast Fourier Transform (1)
- Fe-Ni oxides (1)
- FeNi nanoparticles (1)
- FeNi thin film (1)
- Femtosecond (1)
- Fenton (1)
- Ferroelectricity/ferroelectric materials (1)
- Few-layered titanium carbide nanosheets (1)
- Field of Analysis (1)
- Field of view (1)
- Flow cytometry (1)
- Fluorescence correction (1)
- Fluorouracil (1)
- Foaming (1)
- Form factor (1)
- Formaldehyde (1)
- Forsterite (1)
- Fourier transform infrared spectroscopy (1)
- Fourier-Transform Infrared Spectroscopy (1)
- Framework (1)
- Fullerene-Polyglycerol Sulfates (1)
- Functionalized nanographene (1)
- Fungus (1)
- GVP (1)
- Gel electrolytes (1)
- General Materials Science (1)
- Genotoxic and oxidative damage (1)
- Glass powder (1)
- Glass-ceramic (1)
- Glycan microarray (1)
- Goethite (1)
- Governance (1)
- Graphen Oxide (1)
- Graphene funcionalisation (1)
- Graphene functionalisation (1)
- Graphene functionalization (1)
- Graphene related materials (1)
- Graphene related two-dimensional materials (GR2M) (1)
- Graphene template (1)
- Graphene-based polyglycerol sulfates (1)
- Graphene–bacteria interaction (1)
- Graphhene (1)
- Graphite furnace (1)
- Grating method (1)
- Green rust (1)
- Grouping (1)
- H-terminated Si3N4 films (1)
- HR-CS-MAS (1)
- Hard X-ray photoelectron spectroscopy (1)
- Hazard assessment (1)
- Hematite (1)
- Heterogeneous catalysis (1)
- Hierarchical micro-nanostructures (1)
- High entropy alloy (1)
- High pressure (1)
- High temperature corrosion (1)
- High-resolution transmission electron microscopy (1)
- High-throughput screening (1)
- Homogeneity (1)
- Homogeneous deposition (1)
- Human umbilical cell adhesion (1)
- Hybrid metrology measurement (1)
- Hydrogen Generation (1)
- Hydrogen assisted cracking (1)
- Hydrogen economy (1)
- Hydrogen evolution reaction (1)
- Hydrogen generation (1)
- Hydrogen photoproduction (1)
- Hydrogenated nanostructures (1)
- Hyperbranched (1)
- Hyperspectral imaging (1)
- ILC on detection methods (1)
- IR spectroscopy (1)
- IR spectroscopy; conductometry (1)
- ISO 21363 (1)
- ISO 23173 (1)
- ISO/TC 201 (1)
- ISO/TC 202 Microbeam Analysis (1)
- ISO/TC229 (1)
- ISOGScope (1)
- Identification (1)
- Iinter-laboratory comparison (1)
- Iionic liquid (1)
- Image Segmentation (1)
- Imaging AES (1)
- Imaging Ellipsometry (1)
- Imaging SIMS (1)
- Imaging surface chemical analysis (1)
- Imaging techniques (1)
- In situ (1)
- In-situ SAXS/WAXS (1)
- Indenter area function (1)
- Indium (1)
- Indium Tin Oxide (1)
- Inelastic background (1)
- Influenza A virus (1)
- Infrared nano AFM (1)
- Instrument compliance (1)
- Intensity scale calibration (1)
- Inter-lab comparison (1)
- Inter-laborator comparison (1)
- Interaction with atmospheres (1)
- Interlaboratory Comparison (1)
- Interlaboratory comparisons (1)
- Intermediate phases (1)
- Intermodulation (1)
- Intermodulation AFM (1)
- International Meter Convention (1)
- Interphase (1)
- Intrinsic OER activity (1)
- Iron (1)
- Iron nanophases (1)
- K-rich Birnessite (K0.45MnO2) (1)
- Katalysator (1)
- Knock-out mutant (1)
- Knowledge (1)
- Kraft Lignin (1)
- LEVASIL 50/50 (1)
- LIPSS (1)
- Label-free detection (1)
- Laboratory experiments (1)
- Lanthanide(III) (1)
- Laser processing (1)
- Laser-induced amorphization (1)
- Laser-induced pariodic surface structures (1)
- Laser-induced periodic surface structures (1)
- Laser-induced periodic surface structures, LIPSS (1)
- Lead-free ceramics (1)
- Lifetime analysis (1)
- Ligand exchange (1)
- Light elements (1)
- Linear polyglycerol (1)
- Lipids (1)
- Lonic liquid (1)
- Low-density polyethylene (1)
- Low-density polyethylene (LDPE) (1)
- Luminescent lifetime (1)
- Luminescent materials (1)
- MALDI (1)
- MXenes (1)
- Magic-sized cluster (1)
- Magnetic nanocatalyst (1)
- Magnetpartikel (1)
- Magnetron Sputtering (1)
- MamaLoCa (1)
- Marble sculptures (1)
- Martensite (1)
- Martin Seah (1)
- Mass spectrometry imaging (1)
- Material defects (1)
- Me-TiO2 (1)
- Measurement uncertainty (1)
- Mechanical properties (1)
- Mechanical stress (1)
- Mechanochemical oxidation (1)
- Mechanochemistry (1)
- Medium entropy alloy (1)
- Melanin Adhesion (1)
- Mesoporosity (1)
- Mesoporous (1)
- Mesoporous Materials (1)
- Mesoporous films (1)
- Mesoporous iridium oxides films (1)
- Mesoporous iridium-titanium mixed oxides (1)
- Mesoporous mixed metal oxide films (1)
- Mesoporous oxide materials (1)
- Mesoporous oxides (1)
- Metal fluorides (1)
- Metal-organic frameworks (1)
- Metal-organic-frameworks (1)
- Metal-semiconductor (1)
- Methane (1)
- Methane removal (1)
- Methane total oxidation (1)
- Method development (1)
- Method validation (1)
- Metrology in Chemistry and Biology (1)
- Micro- and Nanoplastics (1)
- Microarray printing (1)
- Microbeads (1)
- Microbially influenced corrosion (MIC) (1)
- Microdroplet (1)
- Microplastic reference materials (1)
- Microplastics detection (1)
- Microplastics standardisation (1)
- Microwave-assisted synthesis (1)
- Milling (1)
- Mineral tranformation (1)
- Miscible polymer films (1)
- Mixed metal oxide (1)
- Molybdenum (1)
- Morpho-chemical characterization (1)
- Morphogenesis (1)
- Morphology (1)
- Multi-method analysis (1)
- Multi-resistant bacteria (1)
- Multilayers (1)
- Multiplex (1)
- Multivalency (1)
- Mussel-inspired coating (1)
- Mussel-inspired dendritic polyglycerol (MI-dPG) (1)
- Mutual calibration (1)
- Mycotoxins (1)
- Nano CRM (1)
- Nano Characterisation (1)
- Nano characterization (1)
- Nano graphene (1)
- Nano particle (1)
- Nano screening (1)
- Nano structure (1)
- Nano-characterisation (1)
- Nano-object (1)
- Nano-powder characterization (1)
- Nano-related data (1)
- Nano-risk assessment (1)
- NanoValid (1)
- Nanoanalysis (1)
- Nanobiointerfaces (1)
- Nanocarrier (1)
- Nanocomposites (1)
- Nanocrystals (1)
- Nanocubes (1)
- Nanodefine (1)
- Nanoindentation (1)
- Nanoinformatics (1)
- Nanomaterial Properties (1)
- Nanomaterial analysis (1)
- Nanomaterial categorisation (1)
- Nanomaterial definition (1)
- Nanomaterial legislation (1)
- Nanomaterial properties (1)
- Nanomaterial regulation (1)
- Nanomaterial screening (1)
- Nanomechanical charecteisation (1)
- Nanomechanical properties (1)
- Nanometrology (1)
- Nanoparticle Characterization (1)
- Nanoparticle size (1)
- Nanoparticle size measurement (1)
- Nanoparticle structure (1)
- Nanoparticular TiO2 (Anatase) (1)
- Nanoplastic (1)
- Nanoplatform (1)
- Nanoplattform (1)
- Nanopowder (1)
- Nanorisk Governance (1)
- Nanosafety services (1)
- Nanoscale (1)
- Nanoscale measurements (1)
- Nanosheets (1)
- Nanostructured FeOx films (1)
- Nanostructured material (1)
- Nanotechnologies (1)
- Nano‐object characterization (1)
- Narrow line method (1)
- Native oxide layer (1)
- Near ambient pressure XPS (1)
- Near ambient x-ray photoelectron spectroscopy (1)
- Near edge X-ray absorption fine structure (1)
- Near-ambient pressure (1)
- Near-ambient pressure X-ray photoelectron spectroscopy (1)
- Neural Networks (1)
- Nitrene [2+1] cycloaddition (1)
- Nitrene[2+1]cycloaddition (1)
- Nm film thickness (1)
- NoStep Standards (1)
- Nobel-metal free electrocatalysis (1)
- Noise in image (1)
- Non-destructive ambient analysis (1)
- Non-spherical (1)
- OECD (1)
- OECD TG 125 (1)
- Ochratoxin A (1)
- Olivine (1)
- One-pot synthesis (1)
- Operando (1)
- Optical analysis (1)
- Optical assay (1)
- Optical constants (1)
- Optical measurement technology (1)
- Optical measurements (1)
- Optical porosimetry (1)
- Optical spectroscopy (1)
- Optically active surfaces (1)
- Organic phosphates (1)
- Orientation (1)
- Osteogenesis (1)
- Osteoporosis (1)
- Oxygen Evolution Reaction (1)
- Oxygen evolution reaction (OER) (1)
- P. Fluorescens (1)
- P25 (1)
- PC characterisation (1)
- Participatory Approach (1)
- Particle Characterization (1)
- Particle architecture (1)
- Particle characterization (1)
- Particle shape (1)
- Partikelgrößenverteilung (1)
- Passivation (1)
- Pelletization (1)
- Perfluorooctanoic Acid (PFOA) (1)
- Phase analysis (1)
- Photodegradation (1)
- Photoelectrochemistry (1)
- Photoemission (1)
- Photoluminescence (1)
- Photophysics (1)
- Photoreforming (1)
- Photoswitchable monolayers (1)
- Physicochemical characterization (1)
- Pigments (1)
- Plasma deposition (1)
- Plastic reference materials (1)
- Platinum (1)
- Polarimetry (1)
- Polycarbonate (1)
- Polyethylene glycol (PEG)-grafting antifouling surface (1)
- Polymer (1)
- Polymer foils (1)
- Polymerization (1)
- Polypropylene (1)
- Polystyrene microparticles (1)
- Porous layers (1)
- Porous materials (1)
- Post-modification by L-cysteine (1)
- Powder (1)
- Powder X-ray diffraction (1)
- Power electronics (1)
- Pphosphates (1)
- Predictive modelling (1)
- Principal Component Analysis (1)
- Principal component analysis (PCA) (1)
- Prodrug antibiotic (1)
- Protein structure (1)
- Provenance information (1)
- Pseudomonas aeruginosa (1)
- Pseudomonas fluorescens (1)
- Py-GC/MS (1)
- QUASES (1)
- Quality control (1)
- Quantitative XPS (1)
- Quantitative surface chemical analysis (1)
- Quartzite rock (1)
- REM (1)
- REM/EDX (1)
- Rainfall simulator (1)
- Raman (1)
- Real-time infrared spectroscopy (1)
- Reference Nanomaterials (1)
- Reference nanomaterials (1)
- Reference nanoparticles (1)
- Reference procedures (1)
- Reference products (1)
- Reference spectra (1)
- Reference standards (1)
- Regional workshop (1)
- Regulatory identification of nanomaterials (1)
- Regulatory risk assesment (1)
- Release kinetics (1)
- Reliabiilty (1)
- Reliability (1)
- Reliable characterization (1)
- Repelling surface coatings (1)
- Reproducibility crisis (1)
- Reproducible Spectra (1)
- Resolution criterion (1)
- Risk Governance (1)
- Risk asessment (1)
- Rotaxanes (1)
- Runoff (1)
- SAM (1)
- SARS-CoV 2 (1)
- SARS-CoV-2 nucleocapsid protein (1)
- SARS-CoV2 inhibitor (1)
- SEC (1)
- SEM micrography (1)
- SEM tilting (1)
- SEM/EDS/STRATAGem (1)
- SKPFM (1)
- SOP (1)
- STEM-in-SEM (1)
- STEM-in-SEM (TSEM) (1)
- Sabatier (1)
- Sample peparation (1)
- Scanning Auger Spectroscopy (1)
- Scanning Electron Microscopy (1)
- Scanning Probe Microscopy (1)
- Scanning Probe methods (1)
- Scanning probe measurements (1)
- Scanning probe microscopy (1)
- Scanning transmission X-ray microscopy (STXM) (1)
- Scattering (1)
- Sealing materials (1)
- Secondary Ion Mass Spectrometry (1)
- Secondary fluorescence (1)
- Secondary fluorescence correction (1)
- Selected Area XPS (1)
- Selected area XPS (1)
- Self-assembled monolayers (1)
- Self-degrading (1)
- Semiconductor (1)
- Semiconductor nanocrystals (1)
- Sensing (1)
- Shape control (1)
- Shape-controlled nanoparticles (1)
- Shape-engineered (1)
- Shell (1)
- Sialic acid (1)
- Siderite (1)
- Silica (1)
- Silicon carbide (1)
- Silver (1)
- Silver nanoparticles (1)
- Single particle (1)
- Single-source-precursor (1)
- Single-strand break (1)
- Singulettsauerstoff (1)
- Sintering (1)
- Size and size distribution (1)
- Size measurement (1)
- Size measurements (1)
- Small Spot XPS (1)
- Small angle x-ray scattering (1)
- Small-Angle X-ray Scattering (1)
- Soft X-ray (1)
- Soft-templated mesoporous films (1)
- Software (1)
- Software UNIFIT 2022 (1)
- Sol-gel synthesis (1)
- Solar Cell (1)
- Solar cells (1)
- Solar concentrator (1)
- Solar energy (1)
- Solarpur (1)
- Sonochemical synthesis (1)
- Specific Surface Area (BET) (1)
- Spectrometer check (1)
- Spectroscopic ellipsometry (SE) (1)
- Spectroscopic imaging ellipsometry (1)
- Spectroscopy / Instrumentation (1)
- Spectroscopy / Theory (1)
- Spectrum imaging (1)
- Stabilization (1)
- Stakeholder (1)
- Standard Operation Procedures (1)
- Standard operation procedures (1)
- Standardized check (1)
- Straight edge method (1)
- Streptavidin binding (1)
- Strontium titanate (1)
- Structural characterisation (1)
- Structure activity relationships (1)
- Structure-properties relationships (1)
- Struvite (1)
- Sulfated materials (1)
- Sulphidation (1)
- Surface (1)
- Surface Analysis Working Group (1)
- Surface Analytics (1)
- Surface Chemical Transformation (1)
- Surface Chemistry (1)
- Surface analyses (1)
- Surface analysis, (1)
- Surface analytic (1)
- Surface characterization (1)
- Surface chemical analysis of biofilms (1)
- Surface chemisttry (1)
- Surface morphology and chemistry (1)
- Surface plasmon resonance (1)
- Surface regeneration (1)
- Surface-initated grafting (1)
- Sustainability (1)
- Swell-capture (1)
- Synchrotron (1)
- Synchrotron-XPS (1)
- T-SEM (1)
- TGA (1)
- TMB (1)
- TRL (1)
- TSEM (1)
- Ternary zinc alloys (1)
- Themal Transitions (1)
- Thermal annealing (1)
- Thermoplastics (1)
- Thermoresponsive poly(glycidyl ether) coatings (1)
- Thermosets (1)
- Thickness measurements (1)
- Thin Polymer Layers (1)
- Thin mesoporous films (1)
- Thiols (1)
- Threshold (1)
- Thumor therapy (1)
- Ti-6Al-4V alloy (1)
- TiO2 D540 nanoparticles (1)
- TiO2 PVP (1)
- TiO2 nanoparticle (1)
- TiO2 nanoparticles (1)
- Tilting (1)
- Time of Flight - Secondary ion mass spectrometry (1)
- Time-of-Flight Secondary Ion Mass Spectrometry (1)
- Time-of-Flight secondary ion mass spectrometry (1)
- Time-of-flight secondary ion mass spectrometry (1)
- Time-offlight secondary ion mass spectrometry (ToF-SIMS) (1)
- Titanium (1)
- Titanium Carbide Nanosheets (1)
- Titanium Dioxide (1)
- Titanium alloy (1)
- ToF SIMS (1)
- Tools (1)
- TopasMC (1)
- Toxicology (1)
- Traceable nanoparticle size measurements; (1)
- Traceable size (1)
- Transition metal (1)
- Transmission electron microsocpy (1)
- Transmission function IERF (1)
- Trends (1)
- Triazine (1)
- Two-dimensional hexagonal boron nitride(h-BN) (1)
- UV Weathering (1)
- UV-curing (1)
- Ultra thin polymer films (1)
- Ultrashort laser processing (1)
- Uncertainty budget (1)
- VMAAS (1)
- VOx catalyst (1)
- Variable excitation (1)
- Virucidality (1)
- Volcano plot (1)
- Volume specific surface area (1)
- Wastewater (1)
- Wastewater treatment (1)
- Water atmosphere (1)
- Water dispersibility (1)
- Water electrolysis (1)
- Water splitting (1)
- Weathering (1)
- White light interferometric microscopy (1)
- White-light Interference Microscopy (1)
- Wide bandgap compound semiconductor (1)
- Wide bandgap compound semiconductors (1)
- Wide bandgap semiconductors (1)
- Wide-bandgap semiconductors (1)
- X-Ray Reflectometry (1)
- X-Ray Spectroscopy (1)
- X-ray Fluorescence (1)
- X-ray absorption Fine Spectroscopy (1)
- X-ray absorption spectroscopy (1)
- X-ray detectors (1)
- X-ray fluorescence (XRF) (1)
- X-ray photoelectron spectroscopy (XPS) (1)
- X-ray refraction (1)
- X-ray scattering (1)
- X-ray spectrometry (1)
- X-ray tomographic (1)
- XANES (1)
- XAS (1)
- XPS background analysis (1)
- XRD (1)
- Xerogel (1)
- Zeta potential (1)
- Zinc oxide (1)
- ZnO (1)
- ZnO nanoparticles (1)
- ZnSe (1)
- ZrO2 nanoparticles (1)
- [MMIM]+[DMP]− (1)
- analytical service (1)
- electron microscopy (1)
- graphene related 2D materials (1)
- k-values (1)
- layered system (1)
- nm films (1)
- shape control (1)
- transmission mode (1)
- wrapping (1)
- µ-FTIR (1)
- µ-Raman (1)
Organisationseinheit der BAM
- 6 Materialchemie (562)
- 6.1 Oberflächen- und Dünnschichtanalyse (562)
- 1 Analytische Chemie; Referenzmaterialien (50)
- 6.6 Physik und chemische Analytik der Polymere (43)
- 4 Material und Umwelt (32)
- 5 Werkstofftechnik (27)
- 1.2 Biophotonik (25)
- 6.3 Strukturanalytik (23)
- 6.7 Materialsynthese und Design (23)
- 6.2 Material- und Oberflächentechnologien (21)
Paper des Monats
- ja (7)
Ionizing radiation damage to DNA plays a fundamental role in cancer therapy. X-ray photoelectron-spectroscopy (XPS) allows simultaneous irradiation and damage monitoring. Although water radiolysis is essential for radiation damage, all previous XPS studies were performed in vacuum. Here we present near-ambient-pressure XPS experiments to directly measure DNA damage under water atmosphere. They permit in-situ monitoring of the effects of radicals on fully hydrated double-stranded DNA. The results allow us to distinguish direct damage, by photons and secondary low-energy electrons (LEE), from damage by hydroxyl radicals or hydration induced modifications of damage pathways. The exposure of dry DNA to x-rays leads to strand-breaks at the sugar-phosphate backbone, while deoxyribose and nucleobases are less affected. In contrast, a strong increase of DNA damage is observed in water, where OH-radicals are produced. In consequence, base damage and base release become predominant, even though the number of strand-breaks increases further.
Elemental composition and thickness determination of thin films by electron probe microanalysis
(2023)
Electron probe microanalysis (EPMA) applies to solid samples of homogenous (bulk) chemical composition and can usually not be applied to structures which are inhomogeneous in the micrometer range such as thin film systems down to a few nm. However, in combination with the established thin film software Stratagem, the thickness as well as the elemental composition of thin films on a substrate can be determined. This has been recently successfully demonstrated for Fe-Ni on Si and Si-Ge on Al2O3 thin film systems. For both systems five samples of different elemental composition and a reference were produced and characterised by inductively coupled plasma mass spectrometry (ICP-MS), Rutherford backscattering (RBS), and transmission electron microscopy (TEM) as reference values. Last year, a new and open-source thin film evaluation programme called BadgerFilm has been released. It can also be used to determine thin film composition and thickness from intensity ratios of the unknown sample and standards (k-ratios). In this contribution, we reevaluated the data acquired for the Fe-Ni and Si-Ge systems using the BadgerFilm software package and compared the obtained elemental compositions and thickness values with the results of the Stratagem software and the reference methods. The conclusion is that the BadgerFilm software shows good agreement with the elemental composition and thickness calculated by Stratagem (mostly <2% for both composition and thickness) and with the reference values for two representative thin film systems (<1%–2% for composition and <10%–20% for thickness).
The obvious benefits derived from the increasing use of engineered nano-, new, and advanced materials and associated products have to be weighed out by a governance process against their possible risks. Differences in risk perception (beliefs about potential harm) among stakeholders, in particular nonscientists, and low transparency of the underlying decision processes can lead to a lack of support and acceptance of nano-, new, and other advanced material enabled products. To integrate scientific outcomes with stakeholders needs, this work develops a new approach comprising a nine-level, stepwise categorization and guidance system entitled “Knowledge, Information, and Data Readiness Levels” (KaRLs), analogous to the NASA Technology Readiness Levels. The KaRL system assesses the type, extent, and usability of the available data, information, and knowledge and integrates the participation of relevant and interested stakeholders in a cocreation/codesign process to improve current risk assessment, communication, and governance. The novelty of the new system is to communicate and share all available and relevant elements on material related risks in a user/stakeholder-friendly, transparent, flexible, and holistic way and so stimulate reflection, awareness, communication, and a deeper understanding that ultimately enables the discursive process that is needed for the sustainable risk governance of new materials.
In the present paper we show an approach of measuring large numbers of nanoparticles in a single scan TKD. TiO2 anatase nanoparticles (NP) of bipyramidal shape were deposited on standard carbon grid used for TEM. The procedure used promoted formation of NP ‘monolayer’ islands with uniform distribution of NPs on the carbon surface which allowed mapping of large number of nanoparticles in the single island.
Collection of whole map covering ~2800 nanoparticles took nearly 20 minutes. Inverse pole figure color coded map indicates that the NPs are either lying on a {101} facet (within 10° range around perfect {101} parallel to the carbon surface orientation) on the carbon film or are lying on a {100} facet (within 10° range around the perfect {100} parallel to the carbon surface orientation). Very unlikely was the NP orientation standing on a {001} face. The NPs size distribution described as equivalent circle diameter (ECD) has been also evaluated and the mean NP ECD was 59 nm with standard deviation of 15 nm, i.e. in good agreement with electron microscopy or AFM results.
This study shows high potential of the technique for crystalline NPs analysis with respect to geometrical orientation of the particles on the substrate. With known orientation, the 3D dimensional characterisation of such non-spherical NPs becomes possible from 2D projection electron micrographs. Moreover, the NP size distribution can be easily extracted. Superior accuracies down to 1-2 nm are achievable. The approach is applicable also on thin lamellae extracted from particulate (or mesoporous) layers.
Following points are presented and discussed: i) nPSize as an EMPIR project on the nanoparticle size and shape distribution of (more) complex particles including sample preparation and machine learning approaches; ii) parallel development of ISO 21363 (PSSD by TEM), ISO 19749 (PSSD by SEM), ISO 22292 (3D TEM), ISO 52408 (NP Prep for AFM and EM), iii) VAMAS and pre-standardisation, TWA 34 „Nanoparticle Populations“ with two nPSize ILC projects P15 & P16 – results to be published and integrated in ISO 21363 (PSSD by TEM); iv) Remaining challenges: platelets, 2D materials (TiO2 and GR2M); v) Reference data sets as part of a complete Characterisation Workflow.
Electron probe microanalysis (EPMA)is a non-destructive technique which assumes a sample of homogenous (bulk) chemical composition and can, therefore, not be used for thin film samples. However, in combination with one of the possible thin film software packages, STRATAGEM, the thickness as well as the composition of such films on a substrate can be determined.
This has been demonstrated for FeNi on Si and SiGe on Al2O3 film systems. For both systems five samples with different elemental composition and a reference were produced and characterised by the Korean research institute KRISS using inductively coupled plasma mass spectrometry (ICP-MS), Rutherford backscattering (RBS), and transmission electron microscopy (TEM).
In 2021, a new and open source thin film evaluation programme called BADGERFILM has been released. It can also be used to determine thin film composition and thickness from intensity ratios of the unknown sample and standards (k-ratios).
In this contribution, we re-evaluated the data acquired for the FeNi and SiGe systems using the BADGERFILM software package and compared the resulting composition and thickness with the results of the established STRATAGEM software and other reference methods. With the current evaluation, the BADGERFILM software shows good agreement with the composition and thickness calculated by STRATAGEM and provided by the KRISS.
These results between two well-known layered material systems analysed with available conventional EMPA approaches (STRATAGEM and direct thickness measurement by TEM) and a new one (BADGERFILM) proves that reliable non-destructive thin film analysis is possible. In this way, we validate the performance of the new software, which is not at all self-explanatory for such
complex quantification algorithms lying behind the final quantified results.
(Pre)Standardisation and Metrology in Microbeam Analysis – Ongoing Activities and Opportunities
(2023)
The presentation addresses the current ongoing projects as well as the gaps and opportunities in microbeam analysis within ISO/TC 202 Microbeam Analysis standardisation body and in-liaison Technical Working Areas (TWAs) at the pre-standardization platform of VAMAS (Versailles Project on Advanced Materials and Standards).
The glass transition behavior of thin films of poly(bisphenol A carbonate) (PBAC) was studied employing ellipsometry. The glass transition temperature increases with the reduction of the film thickness. This result is attributed to the formation of an adsorbed layer with a reduced mobility compared to bulk PBAC. Therefore, for the first time, the growth kinetics of the adsorbed layer of PBAC was investigated, prepared by leaching samples from a 200 nm thin film which were annealed for several times at three different temperatures. The thickness of each prepared adsorbed layer was measured by multiple scans using atomic force microscopy (AFM). Additionally, an unannealed sample was measured. Comparison of the measurements of the unannealed and the annealed samples provides proof of a pre-growth regime for all annealing temperatures which was not observed for other polymers. For the lowest annealing temperature after the pre-growth stage only a growth regime with a linear time dependence is observed. For higher annealing temperatures the growth kinetics changes from a linear to a logarithmic growth regime at a critical time. At the longest annealing times the films showed signs of dewetting where segments of the adsorbed film were removed from the substrate (dewetting by desorption). The dependence of the surface roughness of the PBAC surface on annealing time also confirmed that the films annealed at highest temperatures for the longest times desorbed from the substrate.
The microstructure of an apatite-wollastonite (code name AP40) glass-ceramic is analyzed in this study by combining 2D microscopy, phase analysis, X-ray absorption and synchrotron X-ray refraction computed tomography (XCT and SXRCT, respectively). It is shown that this combination provides a useful toolbox to characterize the global microstructure in a wide scale range, from sub-micrometer to millimeter. The material displays a complex microstructure comprising a glassy matrix with embedded fluorapatite and wollastonite small crystals. In this matrix, large (up to 200 μm) spike-shaped structures are distributed. Such microstructural features are oriented around a central sphere, thereby forming a structure resembling a sea urchin. A unique feature of SXRCT, in contrast to XCT, is that internal interfaces are visualized; this allows one to show the 3D distribution of these urchins with exceptionally good contrast. Furthermore, it is revealed that the spike-shaped structures are not single crystals, but rather composed of sub-micrometric crystals, which are identified as fluorapatite and diopside phases by SEM-EDX analysis.
Critical defects, also known as device killers, in wide bandgap semiconductors significantly affect the performance of power electronic devices. We used the methods imaging ellipsometry (IE) and white light interference microscopy (WLIM) in a hybrid optical metrology study for fast and non-destructive detection, classification, and characterisation of defects in 4H–SiC homoepitaxial layers on 4H–SiC substrates. Ellipsometry measurement results are confirmed by WLIM. They can be successfully applied for wafer characterisation already during production of SiC epilayers and for subsequent industrial quality control.
An overview on the VAMAS technical working areas (TWA) and projects where Germany is active has been given. The role of VAMAS as an international pre-standardisation platform, including its intense collaboration with international bodies ISO, CEN, OECD and CCQM and national organizations like DIN has been highlighted.
The progress of the VAMAS Project 16 "Measurement of (relative) number concentration of bimodal silica nanoparticles including deposition from liquid suspension" in TWA 34 Nanoparticle Populations is presented. Follwowing points are discusssed:
- Validate the performance of imaging methods to measure the relative number concentration
• electron microscopy (SEM, TEM) and atomic force microscopy (AFM)
• two modes of bimodal (30 and 60 nm) silica nanoparticles
- Validate the performance of small angle X-ray scattering (SAXS) for the traceable measurement of the number concentration of the two modes.
The progress in the VAMAS Project #15" Measurement of particle size and shape distribution of bipyramidal titania including deposition from liquid suspension" within TWA 34 Nanoparticle Populations is presented with highlight of the following points:
- Determine and compare particle size and shape distribution by means of:
• electron microscopy (SEM, TEM, STEM-in-SEM)
• atomic force microscopy (AFM)
• small angle X-ray scattering (SAXS)
- Determine uncertainty induced by deposition protocol from liquid suspension with comparison to known values from a prior ILC with already deposited nanoparticles on TEM grids.
- Provide comparative validation of protocols for the techniques other than TEM.
Die Bestimmung der Nanopartikelgrößen- und -formverteilung nach OECD TG 125 mit der Transmission and Scanning Electron Microscopy (SEM/TEM) wird punktuell vorgestellt:
- Generelles Messprinzip
- Beispiele
- Korrelative Mikroskopie
- Welchen Durchmesser misst die Methode?
- Welche Partikel kann diese Methode messen?
- Welche Informationen kann diese Methode liefern?
- Wo stößt die Methode an ihre Grenzen?
- Implementierung und Datenauswertung,
- Reporting.
Anschließend wurde eine Q&A-Session für die Imaging-Methoden organisiert.
The study described in this paper was conducted in the framework of the European nPSize project (EMPIR program) with the main objective of proposing new reference certified nanomaterials for the market in order to improve the reliability and traceability of nanoparticle size measurements. For this purpose, bimodal populations as well as complexly shaped nanoparticles (bipyramids, cubes, and rods) were synthesized. An inter-laboratory comparison was organized for comparing the size measurements of the selected nanoparticle samples performed with electron microscopy (TEM, SEM, and TSEM), scanning probe microscopy (AFM), or small-angle X-ray scattering (SAXS). The results demonstrate good consistency of the measured size by the different techniques in cases where special care was taken for sample preparation, instrument calibration, and the clear definition of the measurand. For each characterization method, the calibration process is described and a semi-quantitative table grouping the main error sources is proposed for estimating the uncertainties associated with the measurements. Regarding microscopy-based techniques applied to complexly shaped nanoparticles, data dispersion can be observed when the size measurements are affected by the orientation of the nanoparticles on the substrate. For the most complex materials, hybrid approaches combining several complementary techniques were tested, with the outcome being that the reliability of the size results was improved.
The new recommended definition of a nanomaterial, 2022/C 229/01, adopted by the European Commission in 2022, will have a considerable impact on European Union legislation addressing chemicals, and therefore tools to implement this new definition are urgently needed. The updated NanoDefiner framework and its e-tool implementation presented here are such instruments, which help stakeholders to find out in a straightforward way whether a material is a nanomaterial or not. They are two major outcomes of the NanoDefine project, which is explicitly referred to in the new definition. This work revisits the framework and e-tool, and elaborates necessary adjustments to make these outcomes applicable for the updated recommendation. A broad set of case studies on representative materials confirms the validity of these adjustments. To further foster the sustainability and applicability of the framework and e-tool, measures for the FAIRification of expert knowledge within the e-tool’s knowledge base are elaborated as well. The updated framework and e-tool are now ready to be used in line with the updated recommendation. The presented approach may serve as an example for reviewing existing guidance and tools developed for the previous definition 2011/696/EU, particularly those adopting NanoDefine project outcomes.
The ionic liquid 1,3-dimethyl-imidazolium-dimethylphosphate ([MMIM]+[DMP]−) was analyzed using (hard) x-ray photoelectron spectroscopy.
Here, XPS and HAXPES spectra are shown in comparison. For the acquisition of the XPS spectra, monochromatic Al Kα radiation at 1486.6 eV was used, while for the acquisition of the HAXPES spectra, monochromatic Cr Kα radiation at 5414.8 eV was applied. Here, survey scans and high-resolution spectra of P 2p, P 2s, C 1s, O 1s, and N 1s for both methods and P 1s, P KL2,3L2,3, and P KL1L2,3 for HAXPES are shown.
In this workpackage of the ELENA project, we develop a way to express the measurement uncertainty of nanoscale determination of electrical propserties. The method developed aims to be usable for industrial contexts and described in technical documents and standards drafts. Standards and reference samples are used to make traceable measurements available for the end user.
Due to their unique physico-chemical properties, nanoparticles are well established in research and industrial applications. A reliable characterization of their size, shape, and size distribution is not only mandatory to fully understand and exploit their potential and develop reproducible syntheses, but also to manage environmental and health risks related to their exposure and for regulatory requirements. To validate and standardize methods for the accurate and reliable particle size determination nanoscale reference materials (nanoRMs) are necessary. However, there is only a very small number of nanoRMs for particle size offered by key distributors such as the National Institute of Standards and Technology (NIST) and the Joint Research Centre (JRC) and, moreover, few provide certified values. In addition, these materials are currently restricted to polymers, silica, titanium dioxide, gold and silver, which have a spherical shape except for titania nanorods. To expand this list with other relevant nanomaterials of different shapes and elemental composition, that can be used for more than one sizing technique, we are currently building up a platform of novel nanoRMs relying on iron oxide nanoparticles of different shape, size and surface chemistry. Iron oxide was chosen as a core material because of its relevance for the material and life sciences.
We present how mesoporosity can be engineered in transition metal phosphate (TMPs) materials in a template-free manner. The method involves a transformation of a precursor metal phosphate phase, called M-struvite (NH4MPO4·6H2O, M = Mg2+, Ni2+, Co2+, NixCo1-x2+). It relies on the thermal decomposition of crystalline M-struvite precursors to an amorphous and simultaneously mesoporous phase, which forms while degassing of NH3 and H2O. The temporal evolution of mesoporous frameworks and the response of the metal coordination environment were followed with in-situ and ex-situ scattering and diffraction, as well as X -ray spectroscopy. Despite sharing the same precursor struvite structure, different amorphous and mesoporous structures were obtained depending on the involved transition metal. We highlight the systematic differences in absolute surface area, pore shape, pore size, and phase transitions depending on a metal cation present in the analogous M-struvites. The amorphous structures of thermally decomposed Mg-, Ni- and NixCo1-x-struvites exhibit high surface areas and pore volumes (240 m²g-1 and 0.32 cm-3 g-1 for Mg and 90 m²g-1 and 0.13 cm-3 g-1 for Ni). We propose that the low-cost, environmentally friendly M-struvites could be obtained as recycling products from industrial and agricultural wastewaters. These waste products could be then upcycled into mesoporous TMPs through a simple thermal treatment for further applications, for instance, in (electro)catalysis.
Functionalized Ti3C2Tx nanosheets based biosensor for point-of-care detection of SARS-CoV‑2 antigen
(2023)
MXenes are considered a promising class of two-dimensional materials with extraordinary physical and electrochemical properties. Distinguished features like high specific surface area and outstanding electrical conductivity make them suitable for electrochemical biosensing applications. Here, we report the development of a biosensor involving the functionalized MXene−titanium carbide nanosheets (Ti3C2Tx-NS) and monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SARS-CoV-2 mAb) to design a point-of-care device for detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 NP) antigen. Few-layered titanium carbide nanosheets (denoted as FL-Ti3C2Tx-NS) have been synthesized using a single-step etching and delamination method and characterized using optical and electron microscopy techniques revealing the suitability for immunosensing applications. Binding studies revealed the excellent affinity between the biosensor and the SARS-CoV-2 NP. Electrochemical detection of SARS-CoV-2 NP is performed using differential pulse voltammetry and read by a smartphone-based user interface. The proposed FL-Ti3C2Tx-NS based biosensor offers the detection of SARS-CoV-2 NP with a limit of detection of 0.91 nM in a wide detection range in spiked saliva samples. Additionally, there is no cross-reactivity in the presence of potential interferants like SARS-CoV-2 spike glycoprotein and bovine serum albumin. These findings demonstrate the potential of MXenes in developing a rapid and reliable tool for SARS-CoV-2 NP detection. While we report the biosensing of SARS-CoV-2 NP, our system also paves the way for the detection of other SARS-CoV-2 antigens like spike protein or other biomolecules based on antigen−antibody interactions.
One-pot covalent functionalization of 2D black phosphorus by anionic ring opening polymerization
(2022)
In this work, a one-pot approach for the covalent functionalization of few-layer black phosphorus (BP) by anionic ring opening polymerization of glycidol to obtain multifunctional BP-polyglycerol (BP-PG) with high amphiphilicity for near-infrared-responsive drug delivery and biocompatibility is reported. Straightforward synthesis in combination with exceptional biological and physicochemical properties designates functionalized BP-PG as a promising candidate for a broad range of biomedical applications.
As virus outbreaks continue to pose a challenge, a nonspecific viral inhibitor can provide significant benefits, especially against respiratory viruses. Polyglycerol sulfates recently emerge as promising agents that mediate interactions between cells and viruses through electrostatics, leading to virus inhibition.
Similarly, hydrophobic C60 fullerene can prevent virus infection via interactions with hydrophobic cavities of surface proteins. Here, two strategies are combined to inhibit infection of SARS-CoV-2 variants in vitro. Effective inhibitory concentrations in the millimolar range highlight the significance of bare fullerene’s hydrophobic moiety and electrostatic interactions of polysulfates with surface proteins of SARS-CoV-2. Furthermore, microscale thermophoresis measurements support that fullerene linear polyglycerol sulfates interact with the SARS-CoV-2 virus via its spike protein, and highlight importance of electrostatic interactions within it. All-atom molecular dynamics simulations reveal that the fullerene binding site is situated close to the receptor binding domain, within 4 nm of polyglycerol sulfate binding sites, feasibly allowing both portions of the material to interact simultaneously.
Reliable and straightforward characterization and analysis of carbon-based nanomaterials on the atomic level is essential to exploring their potential for application. Here we use a combination of highly surface sensitive x-ray photoelectron (XP) spectroscopy and near edge x-ray absorption fine structure spectroscopy (NEXAFS) to study and quantify the covalent functionalization of nanographene and single-walled carbon nanotubes with nitrene [2 + 1]-cycloaddition. With this comprehensive analytical approach, we demonstrate that the π-conjugated system of functionalized carbon-based nanomaterials is preserved according to NEXAFS analysis, which is challenging to prove with XP spectroscopy investigation alone. Using this combination of analytical approaches, we show significant similarities after functionalization for various carbon-based nanomaterials. Both analytical methods are strongly suited to study possible post-modification reactions of functionalized carbon-based nanomaterials.
Nanoparticles (NPs) have become important materials for a variety of chemical technologies, including catalysis. One of the main challenges is the reduction of green house gases, such as CO2. One opportunity besides the capturing is the conversion to synthesis gas via the reverse water-gas shift reaction.
A facile and efficient method is described for the solvothermal synthesis of size-tunable, stable, and uniform NiCu core-shell NPs. The diameter of the NPs can be tuned in a range from 6 nm to 30 nm and the Ni:Cu ratio from 30:1 to 1:1. The NPs are structurally characterized with combination of transmission electron microscopy, anomalous small-angle X-ray scattering, X-ray photoelectron spectroscopy, and X-ray absorption fine structure. Using these analytical methods, a core-shell-shell structure their chemical composition is elucidated. A depletion from the core to the shell is observed, with the core consisting of NiCu alloy, surrounded by an inner Ni-rich shell and an outer NiO shell. The SiO2-supported NiCu core-shell NPs show pronounced selectivity of >99% for CO in the catalytic reduction of CO2 to CO using hydrogen as reactant (reverse water–gas shift reaction).
Since its discovery, graphene has got growing attention in the industrial and application research due to its unique properties . However, graphene has not been yet implemented into the industrial market, in particularly due to the difficulty of properly characterizing this challenging material. As most of other nanomaterials, graphene’s properties are closely linked to its chemical and structural properties, such as number of layers, flake thickness, degree of functionalisation and C/O ratio. For the commercialization, suitable procedures for the measurement and characterization of the ultrathin flakes, of lateral dimensions in the range from µm to tens of µm, are essential.Surface chemical methods, especially XPS, have an outstanding role of providing chemical information on the composition. Thereby, one well-known problem for surface analytical methods is the influence of contamination on the composition as in the case of adventitious carbon. The differentiation between carbon originated from the contamination or from the graphene sample itself is often not obvious, which can lead to altered results in the determination of the composition. To overcome this problem, Hard Energy X-ray Photoelectron Spectroscopy (HAXPES) offers new possibilities due to its higher information depth. Therefore, XPS measurement obtained with Al Kα radiation (E = 1486. 6 eV) were compared with analyses performed with a Cr Kα (E = 5414. 8 eV) excitation on functionalized graphene samples. Differences are discussed in terms of potential carbon contamination, but also of oxygen on the composition of the samples. Measurements are performed on O-, N- and F-functionalized graphene. Different preparation procedures (powder, pellet, drop cast from liquid suspension) will be also discussed, correlation of the results with the flakes morphology as well as their validation with other independent methods are in progress.
The liaison report from the ISO Technical Committee ISO/TC 202 'Microbeam Analysis' for the November 2022 ISO/TC 229 Nanotechnologies Plenary Meeting Nanotechnologies Liaison Coordination Group (NLCG) is provided. Essential Information such as newly published standards and projects in develeopment relevant for ISO/TC 229 resulted from the progress within the last year and additional comments on behalf of ISO/TC 202 are included in the report.
Hybrid optical measurement technique for detection of defects in epitaxially grown 4H-SiC layers
(2022)
Recent developments in power electronics require the use of new wide bandgap compound semiconductors. Silicon carbide (SiC) is one of the most promising materials for power electronics due to its outstanding properties and commercial availability. Some types of defects in the SiC substrates or homoepitaxial SiC layers can affect the performance of electronic devices in a serious manner or make its operation even impossible. Optical methods such as imaging ellipsometry (IE) and white light interference microscopy (WLIM) were applied for fast and non-contact investigation of defects in the epitaxially grown 12 µm 4H-SiC layers on 4H- SiC substrates.
Ellipsometry enables the investigation of material properties over a broad spectral range. As a fast and non-destructive method, it is widely used in industry for quality assurance. Despite the wide application of ellipsometry and its high industrial relevance there are some material-specific standards and there have been no generally accepted standards dealing with model validation and measurement uncertainties. The first German standard DIN50989-1: 2018 Ellipsometry – Part1: Principles (currently international standard ISO 23131: 2021) marks the beginning of a 6-part standard series for ellipsometry, which was developed under consideration of GUM.
Luminescent semiconductor quantum dots (QDs) are frequently used in the life and material sciences as reporter for bioimaging studies and as active components in devices such as displays, light-emitting diodes, solar cells, and sensors. Increasing concerns regarding the use of toxic elements like cadmium and lead, and hazardous organic solvents during QD synthesis have meanwhile triggered the search for heavy-metal free QDs using green chemistry syntheses methods. Interesting candidates are ternary AgInS2 (AIS) QDs that exhibit broad photoluminescence (PL) bands, large effective Stokes shifts, high PL quantum yields (PL QYs), and long PL lifetimes, which are particularly beneficial for applications such as bioimaging, white light-emitting diodes, and solar concentrators. In addition, these nanomaterials can be prepared in high quality with a microwave-assisted (MW) synthesis in aqueous solution. The homogeneous heat diffusion and instant temperature rise of the MW synthesis enables a better control of QD nucleation and growth and thus increases the batch-to-batch reproducibility. In this study, we systematically explored the MW synthesis of AIS/ZnS QDs by varying parameters such as the order of reagent addition, precursor concentration, and type of stabilizing thiol ligand, and assessed their influence on the optical properties of the resulting AIS/ZnS QDs. Under optimized synthesis conditions, water-soluble AIS/ZnS QDs with a PL QY of 65% and excellent colloidal and long-term stability could be reproducible prepared.
Binary photoluminescent semiconductor nanocrystals (quantum dots, QDs) are one of the best studied fluorescent nanomaterials, and their unique optoelectronic properties paved the road to many applications in (bio)nanophotonics, optoelectronics, and photovoltaics. However, concerns related to their toxic constituents like cadmium or lead and the emerging interest in greener chemistry synthesis approaches hamper their future applicability. Interesting alternatives for some applications like biosensing or bioimaging are heavy-metal-free ternary QDs like AgInS2 (AIS), CuInS2 (CIS), and quaternary QDs such as AIS-ZnS (ZAIS). In this context, we explored the effect of ligand denticity on the organic-to-aqueous phase transfer of oleylamine-stabilized ZAIS QDs with the hydrophilic ligands mercaptopropionic acid (MPA), dihydrolipoic acid (DHLA), and 3-mercapto-2,2-bis(mercaptomethyl)propanoic acid (3MPA), bearing mono-, bi-, and trialkyl thiol groups. Spectroscopic studies of the resulting water-dispersible ZAIS QDs revealed a considerable influence of ligand denticity and ligand-to-QD ratio on the spectral position and width (FWHM; full width at half-maximum) of the photoluminescence (PL) bands, the PL quantum yields (PL QY), and the PL decay kinetics. Thiol capping and phase transfer resulted in a loss in PL by at least a factor of 2. The ligand-induced PL quenching observed particularly for ligands bearing two or three thiol groups was attributed to the facilitated formation of surface-bound disulfides. The best colloidal stability under high dilution conditions was observed for 3MPA.
Protein adsorption at the air–water interface is a serious problem in cryogenic electron microscopy (cryoEM) as it restricts particle orientations in the vitrified ice-film and promotes protein denaturation. To address this issue, the preparation of a graphene-based modified support film for coverage of conventional holey carbon transmission electron microscopy (TEM) grids is presented. The chemical modification of graphene sheets enables the universal covalent anchoring of unmodified proteins via inherent surface-exposed lysine or cysteine residues in a one-step reaction. Langmuir–Blodgett (LB) trough approach is applied for deposition of functionalized graphene sheets onto commercially available holey carbon TEM grids. The application of the modified TEM grids in single particle analysis (SPA) shows high protein binding to the surface of the graphene-based support film. Suitability for high resolution structure determination is confirmed by SPA of apoferritin. Prevention of protein denaturation at the air–water interface and improvement of particle orientations is shown using human 20S proteasome, demonstrating the potential of the support film for structural biology.
Gold films coated with a graphene sheet are being widely used as sensors for the detection of label-free binding interactions using surface plasmon resonance (SPR). During the preparation of such sensors, it is often essential to subject the sensor chips to a high-temperature treatment in order to ensure a clean graphene surface. However, sensor chips used currently, which often use chromium as an adhesion promoter, cannot be subjected to temperatures above 250 °C, because under such conditions, chromium is found to reorganize and diffuse to the surface, where it is easily oxidized, impairing the quality of SPR spectra. Here we present an optimized preparation strategy involving a three-cycle tempering coupled with chromium (oxide) etching, which allows the graphene-coated SPR chips to be annealed up to 500 °C with little deterioration of the surface morphology. In addition, the treatment delivers a surface that shows a clear enhancement in spectral response together with a good refractive index sensitivity. We demonstrate the applicability of our sensors by studying the kinetics of avidin–biotin binding at different pH repeatedly on the same chip. The possibility to anneal can be exploited to recover the original surface after sensing trials, which allowed us to reuse the sensor for at least six cycles of biomolecule adsorption.
XPS of GR2M
(2022)
Inspired by the chemistry of mussel adhesive proteins, polydopamine (PDA) is one of the simplest and most versatile approaches to confer new functionalities to nearly any material surface. Moreover, PDA exhibits high potential for surface modification and diversified secondary reactions that makes it extremely interesting for a wide range of application including biomedical field, e.g., drug delivery, adhesives, cell adhesion, biosensing. PDA has undergone significant expansion in its applications and is one of the most attractive areas within the materials field. Nevertheless, PDA integration in microdevices is still constrained by poor spatial and temporal control of excited deposition methods.
Herein, we demonstrate a novel maskless approach for PDA micropatterning based on Direct Laser Writing (DLW) that overcomes present limitations. The pattern is formed upon exposure of the dopamine solution by light produced by tightly-focused fs NIR laser that scans substrate surface accordingly to the selected pattern design. Neither strong oxidants, metal ions nor adjusting pH to alkaline is required by this technique. Our method achieves the PDA micropatterns with the spatial resolution of 0.8 µm, at least an order of magnitude smaller than what is possible with other PDA microplanning techniques. The here introduced PDA deposition technique will uniquely unravel applications of polydopamine and other catecholamine-based mussel-inspired materials in various multifunctional systems and microdevices (e.g., MEMS elements, microfluidics).
Adjustment of MPL parameters revealed that the morphology and thickness of resulted PDA microstructures can be controlled by altering the laser power and its scanning velocity. As a result, it also enables the production of micropatterns with structural gradient.
Apart from the glass substrate, we achieved PDA patterning at surfaces of different nature such as polychlorotrifluoroethylene, polydimethylsiloxane, polyethylene terephthalate, silicon wafers, and fluorinated glass coverslips.
The chemical nature of PDA was confirmed by locally recorded vibrational and x-ray photoelectron spectra. To ensure post-modification potential of MPL deposited PDA we demonstrated one-step deposition of micropatterns with trypsin. Obtained bio-functionalised surface can be further applied as a protein sensing active microelement.
Presented in this work DLW-based microfabrication technique and the possibilities for further PDA surface post-functionalization empowers advanced applications of this material in single-molecule bioassays, sensors and other complex microdevices.
The progress in the activities on Microbeam Analysis under VAMAS/TWA 37 is reviewed. Particularly the liaison with the new projects within the ISO technical committee TC 202 is presented and discussed with respect to the possibility of identifying and launching related VAMAS projects/inter-laboratory comparisons. The recently started project FIB sample processing for TEM is presented. Next projects in the pipeline involving EBSD and TKD are shortly announced. The need of more promotion for the engagement of more experts from industry and academia at national, European and international level is highlighted. Also, the competition with the other technical working areas (on 'nano' or materials-related) is critically discussed.
Polydopamine (PDA) is one of the simplest and most versatile approaches for forming an excellent binding exterior to confer new functionalities to nearly any material surface. Inspired by nature, it mimics the behavior of mussels and can be easily deposited on virtually all types of inorganic and organic substrates, including superhydrophobic surfaces. Moreover, PDA exhibits high potential for surface modification and diversified secondary reactions that makes it extremely interesting for a wide range of application including biomedical field, e.g., drug delivery, adhesives, cell adhesion, biosensing. PDA has undergone significant expansion in its applications and is one of the most attractive areas within the materials field. Nevertheless, PDA integration in microdevices is still constrained by poor spatial and temporal control of excited deposition methods.
Herein, we demonstrate a novel maskless approach for PDA micropatterning based on Direct Laser Writing that overcomes present limitations. The pattern is formed upon exposure of the dopamine solution by light produced by tightly-focused fs NIR laser that scans substrate surface accordingly to the selected pattern design. Neither strong oxidants, metal ions nor adjusting pH to alkaline is required by this technique to perform dopamine polymerization. Our method achieves the PDA micropatterns with the spatial resolution of 0.8 µm, at least an order of magnitude smaller than what is possible with other PDA microplanning techniques. Some examples of PDA patterns are shown in Figure 1. The here introduced PDA deposition technique will uniquely unravel applications of polydopamine and other catecholamine-based mussel-inspired materials in various multifunctional systems and microdevices (e.g., MEMS elements, microfluidics).
The chemical nature of PDA was confirmed by locally recorded vibrational and x-ray photoelectron spectra. Moreover, the morphology and thickness of PDA microstructure can be controlled by the laser power and scanning velocity revealing the possibility of fabricating the structures with gradient. In most of the applied conditions the increase of the laser intensity and decrease of the scanning velocity would lead to the thicker PDA pattern. Different morphologies from smooth and bulky-like to grain like has been obtained.
PDA was produced in the presence of tris buffer, phosphate buffer and DI water only. We also tested the effect of the solution pH applying pH 6.0, 7.0 and 8.5. Furthermore, the effect of antioxidants and purging of the solution with oxygen and nitrogen was investigated. Summarizing, we could see that the structures could be produced in all the given conditions, however their thickness and quality, morphology and roughness would differ. We did not observe negative impact of the antioxidants and nitrogen purging on the performance of PDA build up indicating that the PDA formation mechanism is different to common autooxidation. The current mechanism is based on the interaction of dopamine molecules with the photoinitiator added to solution as active to DLW laser light component.
Apart from the glass substrate, we achieved PDA patterning at surfaces of different nature such as polychlorotrifluoroethylene, polydimethylsiloxane, polyethylene terephthalate, silicon wafers, and fluorinated glass coverslips.
We also performed facile posts-modification of the PDA surface with protein enzymes like trypsin that was confirmed by XPS. Obtained bioactive pattern could be further integrated in the protein sensing devices.
Presented in this work DLW-based microfabrication technique and the possibilities for further PDA surface post-functionalization empowers advanced applications of this material in single-molecule bioassays, sensors and other complex microdevices.
In this presentation we demonstrate the importance of physico-chemical properties (pc) of micro- and nanoplastic particles (MNPs). These properties determine interaction between MNPs and cells or living organisms. To perform accurate experiments for acquiring pc information it is essential to develop well-characterized and understood plastic reference materials. Such reference materials can be used in interlaboratory comparisons (ILCs). BAM is organizing under VAMAS two ILCs, on micro- and nanoplastics to obtain reliable results and methodologies for pc characterization of MNPs. By gaining profound knowledge on pc properties it becomes possible to estimate the impact of MNPs on the humans and environment and therefore to translate the knowledge to the level of regulation.
Experience gained at BAM within the European project ISGScope on the accurate measureemnt of graphene oxide flakes by electron microscopy is presented. Particularly, factors such as the type of solvent, substrate temperature, but also proper, gentle measurement parameters and image analysis conditions towards automation are highlighted. The measurement procedures in develeopment are being prepared to launch an inter-laboratory comparison under VAMAS (TWA41) as preparatory guidance for future standardisation at ISO.
Nanoparticle Populations
(2022)
Two new projects P15 Measurement of particle size and shape distribution of bipyramidal titania including deposition from liquid suspension and P16 Measurement of (relative) number concentration of bimodal silica nanoparticles including deposition from liquid suspension have been started at VAMAS/TWA 34 under the lead of BAM. First results are presented and discussed.
The modern economy is dependent on catalysis, which is main efforts to create environmentally and energy-friendly technologies. The storage of excess electrical energy into chemical energy by splitting water into hydrogen and oxygen is a feasible solution to this energy demand. Due to their abundance on Earth and inherent stability in alkaline solution, transition-metal oxides have become one of several viable alternatives to noble-metal catalysts. Since NiFe oxide is one of the most active oxygen evolution reaction (OER) electrocatalysts for alkaline water electrolysis, it has been the subject of extensive research.
In this work, NiFe2O4 nanoparticles (NPs) of various sizes, specific stoichiometric and non-stoichiometric Fe:Ni surface ratios are synthesized. we will use a combination of ultra-high vacuum surface analysis techniques, such as time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS), to obtain the detailed characterization of the OER electrocatalysts top-surface layer, which is required to identify the rate-limiting step intermediates, and surface morphological changes at the electrolyte/catalyst.
Quantitative Microstructural Analysis - VAMAS TWA 37 & Liaison with ISO/TC 202 Microbeam Analysis
(2022)
The progress in activities on Microbeam Analysis under VAMAS/TWA 37 is reviewed. Particularly the liaison with the new projects within the ISO technical committee TC 202 is presented and discussed with respect to the possibility of identifying and launching related VAMAS projects. The recently started project FIB sample processing for TEM is highlighted. Need of more promotion for the engagement of more participants from industry and academia at national, European and international level is highlighted. Also, the competition with the other technical working areas (on 'nano' or materials-related) is critically discussed. Further, a short overview of the VAMAS areas of activities is given where Germany is involved. Planed regional VAMAS Workshops in Germany in 2023 are announced.
Luminescent lanthanides(III) offer exceptional optical properties that can overcome issues often encountered with other fluorophores (e.g. organic dyes). Their long lifetimes up to milliseconds, low photobleaching and sharp and characteristic emission peaks make the lanthanides extremely valuable for the development of advanced luminescent materials. Previous work on Ru(II) and Ir(III) gold surfaces further highlights the potential of employing the luminescence of metal complexes for the fabrication of sensing platforms and devices.
Here, we incorporate visible and NIR-emitting lanthanide(III) complexes Ln2L3 (Ln = Eu(III), Nd(III), Yb(III)) to gold and plasmonic surfaces, translating the unique optical properties of the lanthanides(III) to practical devices. The Ln2L3 complexes are deposited on the surfaces with different methods, ranging from polymer aided physisorption to the covalent attachment on the gold surface. Furthermore, we exploit the high sensitivity to the coordination environment of lanthanides(III) to design and prepare a sensing platform.
Hybrid optical measurement technique for detection of defects in epitaxially grown 4H-SiC layers
(2022)
Recent developments in power electronics require the use of new wide bandgap compound semiconductor. We demonstrate the use of the ellipsometry and white light interference microscopy to detect defects in epitaxially grown SiC layers on SiC substrates. Such hybrid optical metrology methods can be used to better understand the mechanism of the development of the defects as well as their effects on the material´s optoelectronic properties.
In the present talk the basics of the Raman spectroscopy and particularly of Raman microscopy are explained. Advantages and disadvantages of the method are highlighted through selected case studies. In the second part of the lecture examples of correlative imaging with electron, X-ray, ion and optical microscopies from micro- to the nanoscale are highlighted.
This work presents the determination of the corrosion characteristics of CrCoNi (medium entropy alloy) and CrMnFeCoNi (high entropy alloy) in 0.1 M NaCl and 0.1 M H2SO4. The morphology and chemical composition of the oxide layers formed on CrCoNi and CrMnFeCoNi were comparatively analyzed by scanning Kelvin probe microscopy (SKPFM) and scanning electron microscopy (SEM) and supported with chemical analysis by means of inductively coupled plasma mass spectrometry (ICP-MS) and X-Ray photoelectron spectroscopy (XPS). The analysis of the 3p core level peaks showed that the oxide layer (native and after anodic passivation) on CrCoNi consisted mainly of Cr oxides, while the oxide layer on CrMnFeCoNi was primarily composed of a mixture of Cr and Fe oxides. In addition, XPS was utilized to assess the oxide layer thicknesses. These results were compared to the thicknesses obtained by means of electrochemical impedance spectroscopy (EIS), with both approaches yielding values up to about 4 nm depending on the electrolyte and the alloy. Cyclic polarization measurements indicated superior corrosion resistance of CrCoNi in both aqueous environments compared to CrMnFeCoNi, as well as to AISI 304 stainless steel.
The initial attachment and subsequent biofilm formation of electroactive bac-teriaShewanella putrefaciensCN32 was investigated to clarify the influence oforganic conditioning layers. A selection of macromolecules and self-assembledmonolayers (SAMs) of different chain lengths and functional groups were pre-pared and characterized by means of infrared spectroscopy in terms of theirchemistry. Surface energy and Zeta (ζ-) potential of the conditioning layers wasdetermined with contact angle and streaming current measurements. Amongthe studied surface parameters, a high polar component and a high ratio ofpolar-to-disperse components of the surface energy has emerged as a successfulindicator for the inhibition of the initial settlement ofS. putrefacienson stainlesssteel AISI 304 surfaces. Considering the negative surface charge of planktonicS. putrefacienscells, and the strong inhibition of cell attachment by positivelycharged polyethylenimine (PEI) conditioning layers, our results indicate thatelectrostatic interactions do play a subordinate role in controlling the attach-ment of this microorganism on stainless steel AISI 304 surfaces. For the biofilmformation, the organization of the SAMs affected the local distribution of thebiofilms. The formation of three-dimensional and patchy biofilm networks waspromoted with increasing disorder of the SAMs.
A comparative analysis is performed by XPS, HAXPES and SEM of industrial functionalised graphene powder of different morphology. The chemical analysis carried out by XPS, which probing depth is around 10nm, and HAXPES, which can reach up to 30nm probing depth. By combining these two techniques is possible to get a rough, non-destructive depth profiling of the sample's surface. The results show a higher concentration of the functionlisation elements on the surface of the sample and the influence of the morphology on the functionalisation process and the C/O ratio.
Steps Forward in the Application of 3,3’,5,5’- Tetramethylbenzidine (TMB) in Amperometric Assays
(2022)
Electrochemical methods make great promise to meet the demand for user-friendly on-site devices for monitoring important parameters. Food industry often runs own lab procedures, e.g. for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with miniaturized technologies. Enzyme-linked immunosorbent assays, with photometric detection of the horseradish peroxidase (HRP) substrate, 3,3’,5,5’-tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straight-forward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material.
It was found that screen-printed gold electrodes and a highly acidic pH value (pH 1) are well-suited to perform the electrochemical detection of TMB, due to the reversible character of the redox reaction under these conditions. This set-up provides a good signal stability over several measuring cycles, providing the basis for analysing multiple samples. In contrast to this, for carbon screen-printed electrodes, it was found that the signal response has changed after the electrochemical reaction with TMB at pH 1. At a weakly acidic pH value (pH 4), neither with carbon nor with gold electrodes a reproducible electrochemical detection of TMB could be achieved [1].
Based on these findings we created a smartphone-based, electrochemical, immunomagnetic assay for the detection of ochratoxin A and ergometrine in real samples. Therefore, a competitive assay was performed on magnetic beads using HRP and TMB/H2O2 to generate the signal. Enzymatically oxidized TMB was quantified after addition of H2SO4 by amperometry with screen-printed gold electrodes in a custom-made wall-jet flow cell. The results are in good correlation with the established photometric detection method, providing a solid basis for sensing of further analytes in HRP-based assays using the newly developed miniaturized smartphone-based, electrochemical, immunomagnetic assay.
MXenes are a new family of two-dimensional (2D) transition metal carbides, carbonitrides, and nitrides discovered in 2011. Among many reported family members, titanium carbide is the most widely studied and explored due to the optimized synthesis conditions and promising characteristics like good mechanical strength, solution processability, and excellent conductivity. Here, we report the development of an electrochemical biosensor involving the amine-functionalized Few-Layered-Titanium Carbide Nanosheets and monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SARS-CoV-2 mAb) to design a point-of-care device for detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 NP) antigen.
The accuracy and comparability of nanoindentation results depend significantly on the calibration of area function and instrument compliance. The area function results should not depend on the reference material used or on the calibration method (direct or indirect). This has been investigated for 18 different Berkovich tips. A novel calibration method is proposed that confirms the material independence of the area function and gives a force-dependent instrument compliance function. An agreement between direct and indirect calibration could only be achieved by considering a radial displacement correction. Further, it is shown that the transition range from a spherical cap to the correct face angle of the pyramid can extend to a depth of more than 250 nm. A better parameter for the indenter than the tip radius is the offset of the contact radius to the radius of an ideal tip at a depth where the correct face angle is reached.
Electrochemical methods make great promise to meet the demand for user-friendly on-site devices for monitoring important parameters. Food industry often runs own lab procedures, e.g., for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with miniaturized technologies. Enzyme-linked immunosorbent assays, with photometric detection of the horseradish peroxidase (HRP) substrate 3,3’,5,5’-tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straight-forward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry, it could be shown that TMB electrochemistry is strongly dependent on the pH and the electrode material.
It was found that screen-printed gold electrodes and a very low pH value (pH 1) are well-suited to perform the electrochemical detection of TMB, due to the reversible character of the redox reaction under these conditions. Under these conditions, a good signal stability over several measuring cycles is achieved, providing the basis for analyzing multiple samples. In contrast to this, for carbon screen-printed electrodes, it was found that the signal response has changed after the electrochemical reaction with TMB at pH 1. At moderately acidic conditions (pH 4), neither with carbon nor with gold electrodes a reproducible electrochemical detection of TMB could be achieved.
Based on these findings, we created a smartphone-based, electrochemical, immunomagnetic assay for the detection of ochratoxin A (OTA) and ergometrine in food samples. A competitive assay is performed on magnetic beads using HRP and TMB/H2O2 to generate the signal. Enzymatically oxidized TMB is quantified after addition of H2SO4 by amperometry with screen-printed gold electrodes in a custom-made wall-jet flow cell. The results are in good correlation with the established photometric detection method, providing a solid basis for sensing of further analytes in HRP-based assays using the newly developed miniaturized smartphone-based, electrochemical, immunomagnetic assay.
Measurement and calculation of x-ray production efficiencies for copper, zirconium, and tungsten
(2022)
Electron probe microanalysis (EPMA) is based on physical relations between measured X-ray intensities of characteristic lines and their Xray production efficiency, which depends on the specimen composition. The quality of the analysis results relies on how realistically the physical relations describe the generation and emission of X-rays. Special experiments are necessary to measure X-ray production efficiencies. A challenge in these experiments is the determination of the detection efficiency of the spectrometer as a function of the photon energy. An energy-dispersive spectrometer was used in this work, for which the efficiency was determined at metrological synchrotron beamlines with an accuracy of ±2%. X-ray production efficiencies for the L series and the Kα series of copper and zirconium and for the M and L series of tungsten were determined at energies up to 30 keV in a scanning electron microscope. These experimental values were compared with calculated X-ray production efficiencies using physical relations and material constants applied in EPMA. The objective of the comparison is the further improvement of EPMA algorithms as well as extending the available database for X-ray production efficiencies. Experimental data for the X-ray production efficiency are also useful for the assessment of spectrum simulation software.
Data for the publication "The role of extracellular polymeric substances of fungal biofilms in mineral attachment and weathering" (https://doi.org/10.1038/s41529-022-00253-1). It includes:
- The Summary of the EPS concentration, EPS sugar components and EPS linkages.
- The Summary of the XPS analysis of freeze-dried biofilm samples of all strains.
- The Summary of the pH, Mg, SI and Fe concentration, biomass and olivine dissolution rate for each time point of all dissolution experiments.
The composition of thin films of polymer blends in vertical direction is still under discussion. For explaining the thickness dependence of some properties like the thermal glass transition temperature, a three-layer model has been introduced consisting of an adsorbed layer with a reduced segmental mobility at the substrate, a bulk-like layer in the middle of the film and an outermost surface layer with a higher molecular mobility. X-ray photoelectron spectroscopy (ER-XPS) measurements with a varying excitation energy from 400 eV to 1486.6 eV and, herewith, an information depth from 1.5 nm to 10 nm were performed at PVME/PS films with compositions of 25/75 wt% and 50/50 wt% and thicknesses between 15 nm and 190 nm. As expected, it was found that the PVME concentration decreases with increasing information depth. Secondly, a complex correlation between the PVME concentration at the surface and the film thickness was found. The PVME concentration increases with decreasing film thickness until a maximum at 30 nm. For thinner films, the PVME concentration decreases. These data agree with previous investigations obtained with specific heat spectroscopy.
We thank BESSY II (HZB) for the allocation of beamtime at the HE-SGM beamline and for technical support. DFG (Project number 124846229) is acknowledged for financial support.
One aim of the EMPIR nPSize project 17NRM04 was to develop and validate three classes of candidate reference (test) materials (RTMs), with i) well-defined non-spherical shape, ii) relatively high polydispersity index, and iii) accurate particle concentrations.
To fulfil the requirements of the project, 11 different types of materials were prepared. Following the initial assessment of the materials suitability, nPSize5_PT_UNITO, nPSize6_AC_UNITO and nPSize7_GN_CEA materials were found unsuitable for the project, due to various reasons. PT material was deemed unsuitable due to its predominantly agglomerated nature. AC material contained relatively high amount of impurities (other particle forms). GN material was found too heterogeneous in both the length and width for the purpose of the project. The remaining 8 candidate RTMs were assessed for their homogeneity and stability and used for successful delivery of the associated activities within the nPSize project.
BAM is currently building up a platform of novel nanoRMs relying on iron oxide nanoparticles of different shape, size and surface chemistry. Iron oxide was chosen as a core material because of its relevance to the material and life sciences.
As a first candidate of this series, we present cubic iron oxide nanoparticles with a nominal edge length of 8 nm. These particles were synthesized by thermal decomposition of iron oleate in high boiling organic solvents adapting well-known literature procedures. After dilution to a concentration suitable for electron microscopy (TEM and SEM) as well as for small-angle X-ray scattering (SAXS) measurements, the candidate nanoRM was bottled and assessed for homogeneity and stability by both methods following the guidelines of ISO 17034 and ISO Guide 35.
The particle sizes obtained by both STEM-in-SEM and TEM are in excellent agreement with a minimum Feret of 8.3 nm ± 0.7 nm. The aspect ratio (AR) of the iron oxide cubes were extracted from the images as the ratio of minimum Feret to Feret resulting in an AR of 1.18 for TEM to 1.25 for SEM. Alternatively, a rectangular bounding box was fitted originating from the minimum Feret and the longest distance through the particle in perpendicular direction. This led to AR values of 1.05 for TEM and 1.12 for SEM, respectively. The results confirm the almost ideal cubic shape.
Water splitting using semiconductor photo-catalysts is considered a sustainable method to produce clean hydrogen fuel. Nevertheless, H2 photo-production efficiency remains still low, although extensive research works to understand better the mechanisms of the Hydrogen Evolution Reaction (HER) and the Oxygen Evolution Reaction (OER) are being carried out. In this respect, TiO2 is a key photoactive material, usually employed with a co-catalyst deposited onto the surface to enhance charge carriers’ separation and catalyze surface charge transfer reactions. The deposition of a co-catalyst on the TiO2 nanoparticle surface represents one successful way to enhance the activity of the photocatalyst through a modification of its surface and redox properties. In this context, high-resolution scanning electron microscopy (SEM) coupled with elemental analysis by energy-dispersive X-ray spectroscopy (EDS) is fundamental for studying and understanding the effect of the nanoparticle morphology on the functional properties of shape-controlled TiO2 crystals (bipyramides, platelets, and elongated particles). Different types of metal-semiconductor combinations, TiO2 shapes and dopant metals (Ag, Pt, Au, Rh, Pd) and metal concentrations are discussed.
Electron Probe Microanalysis (EPMA) provides a non-destructive approach in the dedicated thin film analysis mode with the commercial StrataGem software. Recently, the open-source programme BadgerFilm by Moy and Fournelle became available. Similarly to StrataGem, it is based on the algorithm of Pouchou and Pichoir and needs intensity ratios of the unknown sample and standards (k-values). We have evaluated the k-values measured for the FeNi and SiGe film systems using the BadgerFilm software package and compared the thickness and composition with the results obtained with the established StrataGem software and other reference methods. The thicknesses of the SiGe films obtained by the BadgerFilm software agree within 20% with the StrataGem and TEM results; the elemental compositions BadgerFilm-StrataGEM agree within 2% with one exception (9%).
In order to bridge the gap between lab-scale and industrial-scale production of graphene it is necessary to develop processes, equipment and measurement procedures to control the material features. One of the crucial reasons of graphene’s limited commercialization is the lack of standard procedures to properly characterize and define the material chemical and structural properties down to the nanometer level. This leads to many issues regarding material synthesis repeatability, inappropriateness choice of measurands and measurement reproducibility which heavily affect the consistency of the material performance.
In our study, a comparative analysis is performed on two different series (G5 and G6) of industrial graphene powders, each series produced with four types of functionalization: raw graphene, oxygen-functionalized, nitrogen-functionalized and fluorine-functionalized. All the 8 sample variants were analyzed from a chemical and morphological point of view in the form of powders prepared as slightly pressed in metallic sample holders.
The results of the comparative chemical analyses XPS and EDS show a good agreement in the concentration values for all the elements present in the samples, despite the different analysis volumes addressed by the two techniques. For this reason, the samples can be considered homogeneous in both lateral and vertical direction.
A clear influence of the morphology on the composition is evident. Therefore, such correlative measurements of morphology and composition are necessary for a comprehensive characterization of industrial graphene flakes.
Topical issue: Ellipsometry
(2022)
Ellipsometry is a matured experimental method, whose roots reach back into the early phase of modern optics itself. It is often attributed to be invented by Paul Drude in the last decade of the 19th century, but similar techniques had already been applied for years before Drude started his work. With this Special Issue about ellipsometry and related techniques, we hope to bring more attention to this method and advance and propagate it to be used by a broader community.
Ellipsometry is a matured experimental method, whose roots reach back into the early phase of modern optics itself. It is often attributed to be invented by Paul Drude in the last decade of the 19th century, but similar techniques had already been applied for years before Drude started his work. With this Special Issue about ellipsometry and related techniques, we hope to bring more attention to this method and advance and propagate it to be used by a broader community. We have collected a good mixture of articles: some texts are more in the line of users’ tutorial and best practice guides; others are intended to show recent developments of the method. With this collection, we also hope to show the generally rapidly expanding possibilities of ellipsometry and polarimetry to draw attention of new users and previously unrelated communities to this valuable tool.
Before industrial grade graphene could reach comparable quality to the controlled laboratory scale material, many challenges must be overcome. In order to bridge the gap between lab-scale and industrial-scale production is necessary to develop processes, equipment and measurement procedures to control the material features. One of the most crucial reasons of graphene’s limited commercialization is the lack of standard procedures to properly characterize and define the material chemical and structural properties down to the nanometer level. This leads to many issues regarding material synthesis repeatability, inappropriateness choice of measurands and measurement reproducibility which heavily affect the consistency of the material performance. For example, among all the different industrially produced real-world graphene, it is crucial to determine how many layers of graphene build the material. Products that are built by more than 10 layers should be more correctly referred as nanosized graphite, a problem that is often regarded as the “fake graphene” issue.
In our study, a comparative analysis is performed on two different series (G5 and G6) of industrial graphene powders, each series produced with four types of functionalization: raw graphene, oxygen-functionalized, nitrogen-functionalized and fluorine-functionalized. All the 8 sample variants were analyzed from a chemical and morphological point of view in the form of powders prepared as slightly pressed in metallic sample holders.
The results of the comparative chemical analyses XPS and EDS show a good agreement in the concentration values for all the elements present in the samples, despite the different analysis volumes addressed by the two techniques. For this reason, the samples can be considered homogeneous in both lateral and vertical direction.
A clear influence of the morphology on the composition is evident. Therefore, such correlative measurements of morphology and composition are necessary for a comprehensive characterization of industrial graphene flakes. Protocols for reliable characterization of industrial graphene flakes are in progress.
A competitive advantage in the semiconductors industry is gained through the exploitation of new materials and processes, translating into improved components’ performances. This requires a metrological infrastructure allowing reliable nanoscale characterisation of new materials and devices, particularly in terms of their electrical parameters and properties. Traceability and reliability of nanoscale measurements stand as a major challenge for electrical properties (i.e. resistance, impedance) using conductive atomic force microscopy (C-AFM) and scanning microwave microscopy (SMM) techniques. The non-destructive analysis nature of these two methods is of paramount importance for the characterization of devices and components. However, the state of the art still lacks established measurement protocols, easy to use reference standards, well-defined best practice guides and easy to use 3D models to assess environmental and external stimulation effects. Moreover, costly instrumentation, particularly for high-frequency measurements, still hinders efficient advancements in these directions.
ELENA is a 3-years European project that aims at bringing solutions to the aforementioned difficulties. To achieve this goal, the project uses a combination of nanoscale electrodynamic scanning probe methods in combination with optical tools such as spectroscopic ellipsometry on several lateral length scales to determine the electrical properties of layers and small structures.
For test laboratories operating under accreditation schemes like ISO/IEC 17025 (ISO/IEC 17025), as the international reference for testing and calibration laboratories wanting to demonstrate their capacity to deliver reliable results, a periodical control of the critical instrumental parameters of an Energy-Dispersive X-ray Spectrometer (EDS) is required.
This periodical check of an EDS is specified with exact procedures and materials in the ISO 15632:2021 ”Microbeam Analysis – Selected instrumental performance parameters for the specification and checking of energy-dispersive X-ray spectrometers for use in electron probe microanalysis” (ISO 15632). The EDS check can be simplified to the acquisition of only one 10 kV spectrum from a dedicated test material, EDS-TM002, which is made available by BAM since 2009 (https://webshop.bam.de/webshop_en/). The optional BAM software “EDX spectrometer check” is destined to automatically evaluate this spectrum and determine the performance of the EDS in terms of energy resolution and calibration, as well as possible alteration of low-energy efficiency due to detector contamination. Nearly 200 laboratories have the EDS-TM and associated software package in use.
Practical examples based on various types of artifacts occurred in the EDS spectra and a long-term (>10 years) meticulous observation of the own spectrometers will be discussed. Different types of EDS spectrometers are considered, e.g. Si(Li) and SDD, of various window types (AP, the recent one Si3N4 or even windowless), and with different front contact layers (Au and Ni) (Hodoroaba and Procop, 2014). Evaluation of other parameters or effects such as the deadtime at different count rates or pileup effects is also explained with examples.
This study presents a practical procedure to give access to more information by tilting the sample holder and hence allowing images of a single particle to be recorded at different orientations under the same view angle. From the analysis of these images, extended information on surface roughness of the particle can be extracted. Thus, instead of obtaining 2D information from a single SEM image, three-dimensional (3D) information is obtained from 2D projections recorded at different particle orientations.
The thickness of thin films can be measured by various methods, e.g., profilometry, ellipsometry, atomic force microscopy (AFM), or X-ray reflectometry. For the additional determination of thin film composition, techniques like X-ray photoelectron spectroscopy (XPS) or mass spectrometry-based techniques can be used. An alternative non-destructive technique is electron probe microanalysis (EPMA). This method assumes a sample of homogenous (bulk) chemical composition, so that it cannot be usually applied to thin film samples. However, in combination with the thin film software StrataGEM, the thickness as well as the composition of such films on a substrate can be determined.
This has been demonstrated for FeNi on Si and SiGe on Al2O3 film systems. For both systems five samples with different elemental composition and a reference were produced and characterised by Korean research institute KRISS using inductively coupled plasma mass spectrometry (ICP-MS), Rutherford backscattering (RBS), and transmission electron microscopy (TEM). These samples were used for an international round robin test.
In 2021, a new and open-source thin film evaluation programme called BadgerFilm has been released. It can also be used to determine thin film composition and thickness from intensity ratios of the unknown sample and standards (k-ratios).
In this contribution, we re-evaluated the data acquired for the FeNi and SiGe systems using the BadgerFilm software package and compared the resulting composition and thickness with the results of the established StrataGEM software and other reference methods. With the current evaluation, the BadgerFilm software shows good agreement with the composition and thickness calculated by StrataGEM and as the reference values provided by the KRISS.
The conversion of solar energy into electricity and solar fuels is of crucial importance for a green and sustainable future. Water splitting using semiconductor photo-catalysts is considered a sustainable method to produce clean hydrogen (H2) fuel. Nevertheless, H2 photo-production efficiency remains still low, although extensive research works to understand better the mechanisms of the Hydrogen Evolution Reaction (HER) and the Oxygen Evolution Reaction (OER) are being carried out. In this respect, TiO2 is a key photoactive material, usually employed with a co-catalyst deposited onto the surface to enhance charge carriers’ separation and catalyze surface charge transfer reactions. The deposition of a co-catalyst on the TiO2 nanoparticle surface represents one successful way to enhance the activity of the photocatalyst through a modification of its surface and redox properties. In this context, high-resolution scanning electron microscopy coupled with elemental analysis by energy-dispersive X-ray spectroscopy (EDS) is fundamental for studying and understanding the effect of the nanoparticle morphology on the functional properties of shape-controlled TiO2 crystals (bipyramides, platelets, and elongated particles). Different types of metal-semiconductor combinations, TiO2 shapes and dopant metals (Ag, Pt, etc) and metal concentrations will be discussed.
CS particles show unique properties by merging individual characteristics of the core and the shell materials. An alteration particularly in their surface roughness affects the final performance of the particles in the targeted application. Quantitative evaluation of the roughness of CS microparticles is, however, a challenging task employing microscopic techniques being scarce and showing large differences in terms of methodology and results.
In our previous work, we have reported a systematic study with a reliable analysis tool, which evaluates profile roughness quantitatively, for individual core-shell microparticles using electron microscopy (EM) images of both types, Scanning Electron Microscopy (SEM) and transmission mode SEM (or TSEM). The SEM images contain two-dimensional (2D) information, therefore, provide profile roughness data only from the projection in the horizontal plane (in other words, from the “belly”) of a spherical particle. The present study offers a practical procedure to give access to more information by tilting the sample holder and hence allowing images of a single particle to be recorded at different orientations under the same view angle. From the analysis of these images, extended information on surface roughness of the particle can be extracted. Thus, instead of obtaining 2D information from a single SEM image, three-dimensional (3D) information is obtained from 2D projections recorded at different particle orientations.
Nanosafety is becoming increasingly important as nanomaterials are widely used in industrial processes and consumer products. For nanotoxicity measurements prior sterilization of the samples is necessary, but as structure activity relationships are made with properties of pristine particles, the question arises, if the sterilization process has an impact on the physico-chemical properties of nanoparticles and thus on the biological behavior.
This question will be addressed in this talk. For this purpose, results from SEM and EDS measurements are combined with those of a novel lab-based HAXPES spectrometer in order to obtain a more complete picture. At the end, an influence of sterilization will be evident, which indicates a restructuring of the nanoparticles owing to sterilization.
Nanosafety is becoming increasingly important as nanomaterials are widely used in industrial processes and consumer products. For nanotoxicity measurements prior sterilization of the samples is necessary, but as structure activity relationships are made with properties of pristine particles, the question arises, if the sterilization process has an impact on the physico-chemical properties of nanoparticles and thus on the biological behavior.
This question will be addressed in this talk. For this purpose, results from SEM and EDS measurements are combined with those of a novel lab-based HAXPES spectrometer in order to obtain a more complete picture. At the end, an influence of sterilization will be evident, which indicates a restructuring of the nanoparticles owing to sterilization.
Electron microscopy (EM) is the gold standard for the characterisation of the morphology (size and shape) of nanoparticles. Visual observation of objects under examination is always a necessary first step in the characterisation process. Several questions arise when undertaking to identify and count particles to measure their size and shape distribution. In addition to challenges with the dispersion and identification of the particles, more than one protocol for counting particles is in use. This paper focuses on precise rules for the counting of particles in EM micrographs, as this influences the measurement accuracy of the number of particles, thus implicitly affecting the size values of the counted particles. We review and compare four different, commonly used methods for counting, which we then apply in case studies. The impact of the selected counting rule on the obtained final particle size distribution is highlighted. One main aim of this analysis is to support the application of a specific, well-defined counting approach in accordance with regulatory
requirements to contribute to achieving more reliable and reproducible results. It is also useful for the new harmonised measurement procedures for determining the particle size and particle size distribution of nanomaterials.
Recent developments of X-ray photoelectron spectroscopy using excitation energies different from the usual lab-sources Mg Kα and Al Kα, thus covering larger and different kinetic energy ranges, require more flexible approaches for determining the transmission function than the well-established ones using reference spectra. Therefore, the approach using quantified peak areas (QPA) was refined allowing a more precise estimation of the transmission function. This refinement was tested by comparing the results obtained with the new version with former calculations. Furthermore, the obtained transmission function was validated by comparing the results with a transmission function using the reference spectrum of polyethylene. Additionally, an ionic liquid was used as reference for estimating the transmission function at the energy resolved HE-SGM beamline at BESSY II. Comparison between the measured and stoichiometric composition shows that a transmission function was determined, which allows a reasonable quantification.
Catalysts are important components in chemical processes because they lower the activation energy and thus determine the rate, efficiency and selectivity of a chemical reaction. This property plays an important role in many of today’s processes, including the electrochemical splitting of water. Due to the continuous development of catalyst materials, they are becoming more complex, which makes a reliable evaluation of physicochemical properties challenging even for modern analytical measurement techniques and industrial manufacturing.
We present a fast, vacuum-free and non-destructive analytical approach using multi-sample spectroscopic ellipsometry to determine relevant material parameters such as film thickness, porosity and composition of mesoporous IrOx–TiOy films. Mesoporous IrOx–TiOy films were deposited on Si wafers by sol–gel synthesis, varying the composition of the mixed oxide films between 0 and 100 wt%Ir. The ellipsometric modeling is based on an anisotropic Bruggeman effective medium approximation (a-BEMA) to determine the film thickness and volume fraction of the material and pores. The volume fraction of the material was again modeled using a Bruggeman EMA to determine the chemical composition of the materials. The ellipsometric fitting results were compared with complementary methods, such as scanning electron microscopy (SEM), electron probe microanalysis (EPMA) as well as environmental ellipsometric porosimetry (EEP).
To obtain reliable data on micro- and nanoplastics (MPs, NPs) BAM (Federal Institute for Materials Research and Testing) is organizing interlaboratory comparisons (ILCs). Main focus is detection and physico-chemical characterisation. The accuracy and precision of the results of different laboratories and comparability of the results among the participants are addressed. The ILCs will be performed in the following order: i) ILC #1: Detection and Characterisation of MPs (1-1000 µm) and ii) ILC #2: Detection and Characterisation of NPs (< 1 µm).
For the ILC #1 the parameters to be analysed are: particle size distribution, shape, mass content, particle concentration, with thermoanalytic (Py-GC/MS, TED-GC/MS) and spectroscopy (µ-Raman, µ-FTIR) methods. For the ILC #2 the parameters are: particle size distribution, shape, particle concentration, with methods such as spectroscopical (Raman), Electron Microscopies (SEM, AFM), etc. Exact measurands and methods are still under discussion. BAM will provide test materials of well-known stability and homogeneity. ILC participants will include partners of the CUSP (the European research cluster to understand the health impacts of micro- and nanoplastics), and any other institutions over the world. The ILCs will take place under the international pre-standardisation platform VAMAS, new Technical Working Area 35 “Micro and Nano Plastics in the Environment” (http://www.vamas.org/twa45/).
Inspired by the chemistry of mussel adhesive proteins, polydopamine (PDA) exhibits strong adhesion to nearly any kind of organic or inorganic surface and shows high ability for surface post-modification and secondary reactions. As a result, PDA has been widely used as a base adlayer to enable versatile surface chemistry and functionalization. It has shown great potential in wide range of applications including biomedical field (e.g., drug delivery, adhesives, photothermal therapy, bone and tissue engineering, cell adhesion, biosensing). However, implementation of PDA in microdevices is still hindered by insufficient spatial and temporal control of excited deposition methods.
In this work we present a novel approach to fabricate tunable micropatterned substrates where mussel-inspired chemistry provides base for various surface modification [2]. Current approach applies Multiphoton Lithography (MPL) to initiate local PDA formation, and, therefore, does not require use of microstamp or photomask. As a result, the microstructures of complex designs can be produced with the spatial resolution down to 0.8 μm (Figure 1). The desired design can be easily altered by adjusting the stl model or the fabrication code. Unlike the conventional deposition of PDA based on dopamine auto-oxidation, our method does not require presence of strong oxidants, metal ions or alkaline pH. Herein-demonstrated deposition approach will significantly facilitate applications of polydopamine and other mussel-inspired materials in microdevices and high-resolution active microcomponents (e.g., in MEMS and microfluidics).
Adjustment of MPL parameters revealed that the morphology and thickness of resulted PDA microstructures can be controlled by altering the laser power and its scanning velocity. As a result, it also enables the production of micropatterns with structural gradient. Apart from the glass substrate, we performed PDA patterning at surfaces of different nature such as polychlorotrifluoroethylene, polydimethylsiloxane, polyethylene terephthalate, silicon wafers, and fluorinated glass coverslips. We tested different composition of dopamine solution for its ability of PDA buildup. Solutions containing Tris buffer, phosphate buffer or DI water only as well as different pH (6.0, 7.0 and 8.5) could be successfully applied for high-precision PDA micropatterning. Moreover, the effect of antioxidants and purging of the solution with oxygen and nitrogen was investigated. In all cases, no decrease of deposition efficiency was observed. The chemical nature of PDA was confirmed by locally recorded vibrational and x-ray photoelectron spectra. To ensure post-modification potential of MPL deposited PDA we demonstrated one-step deposition of micropatterns with trypsin. Obtained bio-functionalised surface can be further applied as a protein sensing active microelement.
The fabrication of laser-generated surface structures on titanium and titanium alloys has recently gained remarkable interests, being technologically relevant for applications in optics, medicine, fluid transport, tribology, and wetting of surfaces. The morphology of these structures, and so their chemistry, is influenced by the different laser processing parameters such as the laser fluence, wavelength, pulse repetition rate, the effective number of laser pulses per beam spot area, etc. A simple way to characterize laser-generated surface structures is by means of optical microscopy (OM) or white light interference microscopy (WLIM). The latter can address the surface topography, while having a lateral resolution limit of ~(lambda)/2 (lambda = illumination wavelength). To resolve morphologies with spatial periods significantly smaller than (lambda)/2, scanning electron microscopy (SEM) is often used, taking benefit of the reduced de Broglie wavelength associated to the electrons of several keV energy. However, all the above-mentioned techniques lack the necessary depth-resolution to reveal and quantify sub-surface material modifications of these laser-generated structures. Time-of-Flight secondary ion mass spectrometry (ToF-SIMS) represents a promising surface analytical technique for studying laser-induced chemical surface alterations since the method combines a high surface sensitivity with the capability to perform a depth-profiling of the laser-affected surface zone. In this study we combine WLIM and high-resolution SEM with ToF-SIMS to fully characterize the evolution of various types of laser-generated micro- and nanostructures formed on Ti-6Al-4V alloys upon irradiation by near infrared ultrashort laser pulses (1030 nm, 925 fs) at different laser fluence levels, effective number of pulses, and at different pulse repetition rates (1 – 400 kHz). We show how this combined surface analytical approach allows to evaluate alterations in the surface chemistry and topography of the laser-generated surface structures depending on the laser processing parameters
Even though we often do not knowingly recognize them, nanoparticles are present these days in most areas of our daily life, including food and its packaging, medicine, pharmaceuticals, cosmetics, pigments as well as electronic products, such as computer screens. The majority of these particles exhibits a core-shell morphology either intendedly or unintendedly. For the purpose of practicability, this core-shell nanoparticle (CSNP) morphology is often assumed to be ideal, namely a spherical core fully encapsulated by a shell of homogeneous thickness with a sharp interface between core and shell material. It is furthermore widely presumed that all nanoparticles in the sample possess the same shell thickness. As a matter of fact, most real CSNPs deviate in several ways from this ideal model with quite often severe impact on how efficiently they perform in a specific application.
The topic of this cumulative PhD thesis is the accurate characterization of the actual morphology of CSNPs by advanced X-ray analytical techniques, namely X-ray photoelectron spectroscopy (XPS) and scanning transmission X-ray microscopy (STXM). A special focus is on CSNPs which deviate from an ideal core-shell morphology. In the paper from 2019 nanoparticle shell thicknesses are extracted from the elastic-peak intensities in an XPS spectrum based on an ideal particle morphology. This happens for a series of CSNP samples comprising a poly(tetrafluoroethylene) (PTFE) core and either a poly(methyl methacrylate) (PMMA) or polystyrene (PS) shell. The same paper as well as the paper from 2020 demonstrate for the first time, that the analysis of the inelastic background in an XPS spectrum of CSNPs can identify and quantify the heterogeneity of the shell and the incomplete encapsulation of the core.
The result from an XPS experiment is always an average across a large nanoparticle ensemble. Deviations from an ideal morphology within a single particle of the sample cannot be assessed separately. As opposed to that, a spatial resolution of 35 nm enables STXM to visualize the interior of single CSNPs which exhibit a sufficient X-ray absorption contrast between core and shell material. In the paper from 2018 a STXM analysis is demonstrated based on the example of the PTFE-PS CSNP samples already mentioned in the previous paragraph.
In the publication from 2021 (Ca/Sr)F₂ core-shell like nanoparticle ensembles for the practical use in, among others, antireflective coatings are investigated. These nanoparticles do not possess a sharp interface between core and shell material, which is why a shell thickness determination as described in the second paragraph is inappropriate. Instead, in-depth profiles of the chemical composition are obtained by XPS experiments based on synchrotron radiation with variable X-ray photon energy to elucidate the internal morphology of the particles. Additionally, theoretical in-depth profiles of Ca and Sr XPS peak intensities are simulated, in order to facilitate the interpretation of the experiments. Thus, an enrichment of CaF₂ at the particle surface was determined, which could hardly have been assessed by any other analytical technique. Because this kind of non-destructive depth profiling by XPS is very demanding, more than usual effort is spent on gapless documentation of the experiments to ensure full reproducibility.
Due to the vast diversity of nanoparticles differing in material, composition and shape, a measurement procedure cannot unalteredly be transferred from one sample to another. Nevertheless, because the papers in this thesis present a greater depth of reporting on the experiments than comparable publications, they constitute an important guidance for other scientists on how to obtain meaningful information about CSNPs from surface analysis.
Here, we present a study on agarose thin-film samples that represent a model system for the exopolysaccharide matrix of biofilms. Povidone-iodide (PVP-I) was selected as an antibacterial agent to evaluate our x-ray photoelectron spectroscopy (XPS)-based methodology to trace specific marker elements, here iodine, commonly found in organic matrices of antibiotics. The in-depth distribution of iodine was determined by XPS analyses with variable excitation energies and in combination with argon gas cluster ion beam sputter cycles. On mixed agarose/PVP-I nanometer-thin films, both methods were found to solve the analytical task and deliver independently comparable results. In the mixed agarose/PVP-I thin film, we found the outermost surface layer depleted in iodine, whereas the iodine is homogeneously distributed in the depth region between this outermost surface layer and the interface between the thin film and the substrate. Depletion of iodine from the uppermost surface in the thin-film samples is assumed to be caused by ultrahigh vacuum exposure resulting in a loss of molecular iodine (I2) as reported earlier for other iodine-doped polymers.
Morpho-Chemical Characterisation of Me-TiO2 Nanoparticles for Enhanced Photocatalytical Activity
(2022)
The conversion of solar energy into electricity and solar fuels is of crucial importance for a green and sustainable future. Water splitting using semiconductor photo-catalysts is considered a sustainable method to produce clean hydrogen (H2) fuel. Nevertheless, H2 photo-production efficiency remains still low, although extensive research works to understand better the mechanisms of the Hydrogen Evolution Reaction (HER) and the Oxygen Evolution Reaction (OER) are being carried out. In this respect, TiO2 is a key photoactive material, usually employed with a co-catalyst deposited onto the surface to enhance charge carriers’ separation and catalyze surface charge transfer reactions. The deposition of a co-catalyst on the TiO2 nanoparticle surface represents one successful way to enhance the activity of the photocatalyst through a modification of its surface and redox properties. In this context, high-resolution scanning electron microscopy coupled with elemental analysis by energy-dispersive X-ray spectroscopy (EDS) is fundamental for studying and understanding the effect of the nanoparticle morphology on the functional properties of shape-controlled TiO2 crystals (bipyramides, platelets, and elongated particles). Different types of metal-semiconductor combinations, TiO2 shapes and dopant metals (Ag, Pt, etc) and metal concentrations will be discussed.
Iron-based catalysts are employed in CO2-FTS due to their ability to convert CO2 into CO in a first step and their selectivity towards higher hydrocarbons in a second CO hydrogenation step. According to the literature, iron carbides represent the active phase for hydrocarbon formation and are claimed to emerge in the presence of CO. We propose nanostructured FeOx films as model systems to assess information about the complex phase transformations during CO2-FTS. Mesoporous hematite, ferrihydrite, maghemite, maghemite/magnetite films were exposed to CO2-FTS atmospheres at 20 bar and 300°C. Up to three distinct phases were observed depending on the timeon-stream (TOS): a sintered maghemite/magnetite phase, a carbidic core-shell structure, and a low-crystalline, needle-type oxide phase. Our findings indicate that the formation of an intermediary maghemite/magnetite phase, predominant after short TOS (30 h), precedes the evolution of the carbide phase.
Yet, even after prolonged TOS (185 h), no full conversion into a bulk carbide is observed.
The novel lab-based HAXPES spectrometer (ULVAC-PHI Quantes) gives us the possibility to measure XPS at 1486.6 eV (monochromatic Al Kα source) and HAXPES at 5414.9 eV (monochromatic Cr Kα source) on a sample at the same position. The surface analysis with this spectrometer leads to an information depth of about 10 nm for XPS and in comparison, to an analysis of deeper regions of about 30 nm for HAXPES measurements. This method provides a nondestructive way to distinguish between the near-surface region of the nanoparticles and the whole nanoparticle. Additionally, HAXPES gives access to deeper core levels at higher energy.
An application of this technique is presented using nanoparticles. The results shown were obtained with nanoparticles, that were treated differently by means of sterilization for nanosafety (i.e., before studying their toxicity it is important to establish whether nanomaterials are sterile and, if not, to be treated either via microwave or autoclave sterilisation). As a complementary method, the data is compared with SEM and EDX measurements. All methods demonstrate the influence of sterilization. More specifically, these results show that the sterilization step must be considered in the physical-chemical description of the particles for establishing reliable (quantitative structure-activity) relationships.
microscopy (AFM), or X-ray reflectometry. For the additional determination of thin film composition, techniques like X-ray photoelectron spectroscopy (XPS) or mass spectrometry-based techniques can be used. An alternative non-destructive technique is electron probe microanalysis (EPMA). This method assumes a sample of homogenous (bulk) chemical composition, so that it cannot be usually applied to thin film samples. However, in combination with the thin film software StrataGEM, the thickness as well as the composition of such films on a substrate can be determined.
This has been demonstrated for FeNi on Si and SiGe on Al2O3 film systems. For both systems five samples with different elemental composition and a reference were produced and characterised by Korean research institute KRISS using inductively coupled plasma mass spectrometry (ICP-MS), Rutherford backscattering (RBS), and transmission electron microscopy (TEM). These samples were used for an international round robin test.
In 2021, a new and open-source thin film evaluation programme called BadgerFilm has been released. It can also be used to determine thin film composition and thickness from intensity ratios of the unknown sample and standards (k-ratios).
In this contribution, we re-evaluated the data acquired for the FeNi and SiGe systems using the BadgerFilm software package and compared the resulting composition and thickness with the results of the established StrataGEM software and other reference methods. With the current evaluation, the BadgerFilm software shows good agreement with the composition and thickness calculated by StrataGEM and as the reference values provided by the KRISS.
The recent development of x-ray photoelectron spectroscopy using excitation sources different from the usual lab-source Mg Kα and Al Kα and spectrometers with more sophisticated lens systems requires flexible approaches for determining the transmission function. Therefore, the approach using quantified peak areas (QPA) was refined.1 A new algorithm allows a more precise estimation of the transmission function which could be shown by comparing the results obtained with the new version with former calculations. Furthermore, next to the established reference materials Cu, Ag and Au, ionic liquids can be used for estimating the transmission function at beamlines with variable excitation energies. Comparison between the measured and stoichiometric composition shows that a transmission function was determined which allows a reasonable quantification.
Nanoforms with at least one dimension below 100 nm have an important part to play in more and more areas of our daily life. Therefore, risk assessment of these materials is becoming increasingly important. In this context, the European Chemical Agency (ECHA) considered eleven physico-chemical properties as relevant, of which the following six are essential for the registration: chemical composition, crystallinity, particle size, particle shape, surface chemistry and specific surface area. Four of these priority properties can be obtained with electron microscopy and surface analytics like XPS and ToF-SIMS. The reliability of this data must be ensured, especially for their use for grouping and read across approaches. On the other hand, the “reproducibility” crisis has revealed major shortcomings in the reliability of published data.
In a case study, we show how the quality of the data can be ensured by using existing standards and protocols of each step in the workflow of sample characterization. As exemplary samples, two Al-coated TiO2 samples as nanopowders were selected from the JRC repository, capped either with a hydrophilic or a hydrophobic organic ultrathin shell. SEM results provided the size and shape of the nanoparticles, a first overview about the composition was obtained with EDS. XPS and ToF-SIMS supplied the surface chemistry, especially information about the shell and the coating of the particles. Standards and protocols of all steps of the analytical workflow including preparation and data reduction are discussed regarding reliable and reproducible data. Additionally, uncertainties for the different steps are specified.
Only such a detailed description of all these factors allows a comprehensive physico-chemical characterization of the nanoparticles with understanding of their potential risk assessment.
VAMAS-Enabling international standardisation for increasing the take up of Emerging Materials
(2022)
VAMAS (Versailles Project on Advanced Materials and Standards) supports world trade in products dependent on advanced materials technologies by providing technical basis for harmonized measurements, testing, specification, reference materials and standards. The major tools for fulfilling this task are interlaboratory comparisons (ILC). The organisation structure of VAMAS is presented. It is discussed, how a new technical activity can initiate.
Due to its large strength-to-weight ratio and excellent biocompatibility, titanium materials are of paramount importance for medical applications, e.g. as implant material for protheses. In this work, the evolution of various types of laser-induced micro- and nanostructures emerging on titanium or titanium alloys upon irradiation by near-infrared ultrashort laser pulses (925 fs, 1030 nm) in air environment is studied for various laser fluence levels, effective number of pulses and at different pulse repetition rates (1 – 400 kHz). The morphologies of the processed surfaces were systematically characterized by optical and scanning electron microscopy (OM, SEM). Complementary white-light interference microscopy (WLIM) revealed the corresponding surface topographies. Chemical and structural changes were analysed through depth-profiling time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray diffraction (XRD) analyses. The results point towards a remarkable influence of the laser processing parameters on the surface topography, while simultaneously altering the near-surface chemistry via laser-induced oxidation effects. Consequences for medical applications are outlined.
Using nanofiber-like cell appendages, secreted proteins and sugars, bacteria can establish initial surface contact followed by irreversible adhesion and the formation of multicellular biofilms. Here, the stabilizing extracellular biofilm matrix together with physiological changes on the single cell level leads to an increased resilience towards harsh environmental conditions, antimicrobials, the host immune response and established cleaning procedures. Persistent microbial adhesion on e.g., medical implants, in water supply networks or food-processing industry is often associated with chronic inflammation, nosocomial and foodborne infections, enhanced biofouling and product contamination. To prevent persistent microbial colonization, antibacterial surface strategies often target the initial steps of biofilm formation and impede adhesion of single cells before a mature biofilm is being formed. While chemical coatings have been widely used, their restricted biocompatibility for eukaryotic cells and attenuated antibacterial-effects due to compound release limit their areas of application and alternative strategies focus on modified surfaces topographies to impede bacterial adhesion. In this work, we used ns-UV laser treatment (wavelength 248 nm and a pulse duration of 20 ns) to generate laser-induced periodic surface structures (LIPSS) with different submicrometric periods ranging from ~210 to ~610 nm on commercial poly(ethylene terephthalate) (PET) foils. Following structurally and chemically analyses, PET samples were subjected to bacterial colonization studies with Escherichia coli TG1, a bacterial test strain with a strong biofilm formation capacity due to the formation of nanofiber-like cell-appendages (pili). Bacterial adhesion tests revealed that E. coli repellence decisively depends on the spatial periods of the LIPSS with the strongest reduction (~91%) in cell adhesion observed for LIPSS periods of 214 nm. Scanning electron microscopy and additional biofilm studies using a pili-deficient E. coli TG1 strain revealed the importance of extracellular appendages in the bacterial repellence observed here, thus, pointing out new antibiotics-free strategies for antibacterial surfaces by impeding nanofiber-mediated bacterial adhesion.
In the face of rising energy demand and the impending climate change the development of a sustainable, fossil-free fuel and chemical production is of global importance. One possible goal is the development of electrochemical conversion processes using catalysts. Porous materials play an important role in such energy applications. The activity and stability of each catalyst is highly dependent on the properties of the coating, i.e., phase composition, crystallinity, accessible surface area, and many other factors. The key to the development of improved catalysts is a better understanding of the relations between their performance, stability and physico-chemical properties. However, the complex morphology of such catalysts constitutes a challenge even for modern analytical techniques. Spectroscopic ellipsometry (SE) is a versatile method for studying material properties by using appropriate models (e.g., film thickness, optical and electronic properties). Ellipsometric models need to be validated in order to produce accurate results. In a first step, the model for the ellipsometric fit studies of a calcination series of mesoporous iridium oxide films (300 – 600 °C) was investigated and validated with respect to their material properties.[4] The information on electronic structure of the catalysts shows a direct correlation with electrochemical activities. The development of an environmental electrochemical cell offers the possibility of investigations under operando conditions. Thus, changes in optical and electronic properties can be induced and monitored during the electrocatalytic oxygen evolution reaction.
The roles extracellular polymeric substances (EPS) play in mineral attachment and weathering were studied using genetically modified biofilms of the rock-inhabiting fungus Knufia petricola strain A95. Mutants deficient in melanin and/or carotenoid synthesis were grown as air-exposed biofilms. Extracted EPS were quantified and characterised using a combination of analytical techniques. The absence of melanin affected the quantity and composition of the produced EPS: mutants no longer able to form melanin synthesised more EPS containing fewer pullulan-related glycosidic linkages. Moreover, the melanin-producing strains attached more strongly to the mineral olivine and dissolved it at a higher rate. We hypothesise that the pullulan-related linkages, with their known adhesion functionality, enable fungal attachment and weathering. The released phenolic intermediates of melanin synthesis in the Δsdh1 mutant might play a role similar to Fe-chelating siderophores, driving olivine dissolution even further. These data demonstrate the need for careful compositional and quantitative analyses of biofilm-created microenvironments.
Core–shell nanoparticles have attracted much attention in recent years due to their unique properties and their increasing importance in many technological and consumer products. However, the chemistry of nanoparticles is still rarely investigated in comparison to their size and morphology. In this review, the possibilities, limits, and challenges of X-ray photoelectron spectroscopy (XPS) for obtaining more insights into the composition, thickness, and homogeneity of nanoparticle coatings are discussed with four examples: CdSe/CdS quantum dots with a thick coating and a small core; NaYF4-based upconverting nanoparticles with a large Yb-doped core and a thin Er-doped coating; and two types of polymer nanoparticles with a poly(tetrafluoroethylene) core with either a poly(methyl methacrylate) or polystyrene coating. Different approaches for calculating the thickness of the coating are presented, like a simple numerical modelling or a more complex simulation of the photoelectron peaks. Additionally, modelling of the XPS background for the investigation of coating is discussed. Furthermore, the new possibilities to measure with varying excitation energies or with hard-energy X-ray sources (hard-energy X-ray photoelectron spectroscopy) are described. A discussion about the sources of uncertainty for the determination of the thickness of the coating completes this review.
Both essential aspects of the surface of solid matter, its morphology and chemistry, are studied traditionally at BAM starting in the 60’s with different cyclical research focus areas, mostly related either to applicative research or method development. In the recent years, the focus has shifted almost exclusively to the nano-analytics of advanced materials such as complex nanoparticles, (ultra)thin films/coatings, nanocomposites, 2D materials, energy materials, etc. This is also the reason why BAM has established recently the new Competence Center nano@BAM (www.bam.de/Navigation/DE/Themen/Material/Nanotechnologie/sichere-nanomaterialien.html) with the five sub-fields nanoCharacterisation, nanoMaterial, nanoSafety, nanoData and nanoTechnology. The link to the BAM central guidelines to the safety in technology and chemistry is given by the development of reference products such as reference measurement procedures, reference (nano)materials, and newly reference data sets. Thus, an internationally well-networked group in surface analysis has been established @BAM, with regular contributions to integral analytical characterization with metrological and standardization background.
Examples of newly developed methodical approaches will be given with an emphasis on correlative nano-analysis of morphology and chemistry of nanomaterials. Correlative imaging by STEM-in-SEM with high-resolution SEM and EDX, and further with AFM or the new technique TKD (Transmission Kikuchi Diffraction) will be explained on various examples of nanostructures, both as starting materials and embedded/functionalized nanoparticles in products. The unique analytical benefits of the Auger electron probe as a veritable nano-tool for surface chemistry will be highlighted. The panoply of advanced surface characterization methods @BAM is completed by discussing examples of hybrid analysis of the bulk of nanomaterials by X-ray Spectroscopy with the highest surface-sensitive methods X-ray Photoelectron Spectroscopy (XPS) and Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS). Particularly for the analysis of the surface chemistry of nanostructures, such as the completeness of the shells of core-shell nanoparticles or in-depth and lateral gradients of chemistry within mesoporous thin layers, the latter methods are inherent.
Other special developments like approaches for the quantitative determination of the roughness of particle surface by electron microscopy or for the quantitative determination of the porosity of thin mesoporous layers by electron probe microanalysis (EPMA) with SEM will be presented.
The main outcomes of the EMPIR project nPSize are presented and the suitability of the new capabilities, e.g. reference materials, sample preparation protocols, measurement procedures, and data analysis, to be standardized and implemented in accredited analytical laboratories is discussed. Complementation and/or filling gaps of published and ongoing standardisation projects on size, shape and number concentration measurements under ISO/TC 229/JWG 2 are offered.
The two VAMAS inter-laboratory comparisons resulted from the nSPize project and just started under TWA 34 Nanoparticle Populations (Projects #15 and #16) of bipyramidal TiO2 anatase and bimodal SiO2 nanoparticles are presented in detail.
Core-shell (CS) particles have been increasingly used for a wide range of applications due to their unique properties by merging individual characteristics of the core and the shell materials. The functionality of the designed particles is strongly influenced by their surface roughness. Quantitative evaluation of the roughness of CS microparticles is, however, a challenging task for Scanning Electron Microscopy (SEM).
The SEM images contain two-dimensional (2D) information providing contour roughness data only from the projection of the particle in the horizontal plane. This study presents a practical procedure to achieve more information by tilting the sample holder, hence allowing images of different areas of a single particle to be recorded at different orientations under the same view angle. From the analysis of these images, quasi three-dimensional (3D) information is obtained.
Three types of home-made particles were investigated: i) bare polystyrene (PS) particles, ii) PS particles decorated with a first magnetic iron oxide (Fe3O4) nanoparticle shell forming CS microbeads, iii) PS/Fe3O4 particles closed with a second silica (SiO2) shell forming core-shell-shell (CSS) microbeads. A series images of a single particle were taken with stepwise tilted sample holder up to 10° by an SEM with high-resolution and surface sensitive SE-InLens® mode.
A reliable analysis tool has been developed by a script in Python to analyze SEM images automatically and to evaluate profile roughness quantitatively, for individual core-shell microparticles. Image analysis consists of segmentation of the images, identifying contour and the centre of the particle, and extracting the root mean squared roughness value (RMS-RQ) of the contour profile from the particle projection within a few seconds.
The variation in roughness from batch-to-batch was determined with the purpose to set the method as a routine quality check procedure. Flow cytometry measurements provided complementary data. Measurement uncertainties associated to various particle orientations were also estimated.