6 Materialchemie
Filtern
Erscheinungsjahr
- 2020 (10) (entfernen)
Dokumenttyp
- Vortrag (8)
- Zeitschriftenartikel (2)
Schlagworte
- BAMline (10) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (10)
- 6.3 Strukturanalytik (10)
Eingeladener Vortrag
- nein (8)
Polymer electrolyte membranes (PEM) are polymers which act as separator in an electrochemical cell and allow ionic charge flow to close the circuit. Widely used membranes are perfluorinated sulfonic-acid (PFSA) ionomers (e.g. Nafion™), a class of ion-conducting polymers with remarkable ion conductivity and chemical-mechanical stability. A nanoscopic water system around the sulfonic acid capped side-chains of the otherwise hydrophobic polymer allows the ion transport. Only approx. 14 molecules of water per sulfonic group are present in the fully hydrated state. In vanadium redox flow batteries (VRFB) ideally only protons are transported. The weak ion selectivity of Nafion™ is the main cause for the transportation of vanadium, briefly vanadium crossover, in VRFBs a system we have investigated more closely, lately. The consequences of crossover are a concentration imbalance and a self-discharge of the battery, which leads to a decrease of the capacity. The development of efficient energy storage systems is crucial for the transformation towards a renewable energy based economy. The VRFB has a great potential as a commercial electrochemical energy storage system due to properties including, but not limited to, no cross-contamination, a long cycle-life and a theoretically unlimited capacity. VRFB consists of two half-cells, which are linked to electrolyte tanks and separated by a membrane. The membrane plays a major role in overall cell performance. So far, vanadium transportation models, which include diffusion, migration, electroosmotic convection and pressure gradients, are inconsistent. There is no agreement in the literature on the diffusion coefficients of vanadium species (e.g. published diffusion coefficients of V2+ are located between 3.13·10-12 m²s-1 and 9.44·10-12 m²s-1) indicate that thevanadium crossover is not well understood and there is a lack on a more fundamental level. Since the membrane transport is the rate-determining step of the crossover as well as of the proton exchange it is extremely important to understand these phenomena on a fundamental level. This will eventually allow us to design better membranes. Alternative materials need to show equivalent performance compared with Nafion™ and ideally be more selective regarding ion cross-membrane transport.There are several options to approach the chemistry i.e. the interaction of dissolved and bound ions inside the confined water body of ionomeric membranes. Vanadium ions are a versatile model as UV/VIS data can be used to distinguish between the 5 species V2+, V3+, VO2+, VO2+ and V2O33+ of the electrolyte. Infrared spectroscopy has been applied to study the interaction of sulfonic groups and the ions. Molecular dynamic modeling is another approach to study the distribution and distances of ions. We now introduce X-ray absorption near edge structure spectroscopy (XANES) to study species and species changes inside Nafion™ and a novel membrane based on poly(1,1-difluoroethylene) (PVDF). We evaluated the methods and investigated the influence of irradiation, temperature and hydration on the measurements.
Vanadium redoxflow batteries (VRFB)are currently one of the most promising candidates for stationary energys torage.For large scale applications the ion conducting membranes currently in use need to be improved. Ideally,they need to become more cost efficient and selective regarding the vanadium crossover.For a better understanding of the vanadium crossover, the development of reliable analytical methods and procedures, that elucidate uptake and transport of vanadium ions in the membrane, is necessary. First, we present the uptake of V2+,V3+,VO2+, VO2+ and V2O33+ in Nafion™ and in a novel membrane based onpoly(1,1-difluoroethylene)(PVDF). In preliminary discharge/charge experiments the ETFE-based membrane, the precursor of PVDF-based membrane, performed comparable to Nafion™. The methods of choice for speciation are UV/Vis and X-ray absorption near edge structure spectroscopy (XANES). According to the results, V2O33+, formed from VO2+ and VO2+, diffuses also into the membrane. In present models, the diffusion of V2O33+ is neglected. In addition,we study whether reactions could take place inside the membranes’ nanoscopic water body using XANES. Exposing Nafion™ from one site with V3+a nd from the other site with VO2+ realized the experiment. The results verified that VO2+ was formed inside the membrane. However,in present models reactions inside the membrane are neglected, too.
Various applications for artificial intelligence in the context of spectroscopy will be presented. in particular, examples from BAMline will be presented. After a short introduction to synchrotron radiation, artificial intelligence algorithms for the quantification of X-ray fluorescence measurement are discussed. In the second example, information retrieval by natural language processing is discussed.
Synchrotron radiation sources with their unique properties in terms of intensity, polarization and adjustability offer a wide range of possibilities in materials research. A basic introduction about the creation and special properties of synchrotron radiation will be given. Examples of current work at BAMline, the high-energy measuring facility of the Federal Institute for Materials Research and Testing at the synchrotron BESSY, are used to illustrate the possibilities and limitations of existing measuring methods.
In this talk, the features of X-ray fluorescence analysis with synchrotron radiation will be presented. First, the basics of the origin of synchrotron radiation and X-ray fluorescence analysis and the experimental setup will be discussed. Then, examples of trace element detection, micrometer resolution, and application of the X-ray color camera will be shown.
Gold ist eines der sieben schon im Altertum bekannten Metalle und wurde wg. seines Glanzes und seiner Seltenheit von alters her als Tauschmittel und zur Herstellung von Schmuck benutzt. Außerdem ist es einfach bearbeitbar und weitestgehend gegen chemische Einflüsse resistent. Die Untersuchungen von Gold mit synchrotronstrahlungsangeregter Röntgenfluoreszenzanalyse sind zerstörungsfrei und geben Auskunft über die in der untersuchten Probe vorhandenen chemischen Elemente. Bei den hier vorgestellten Untersuchungen an der BAMline stehen Fragestellungen wie Herkunft, Herstellungsverfahren und Zusammengehörigkeit von Goldfunden im Vordergrund. Die verschiedenen Fragestellungen werden an einer Reihe von Beispielen erläutert die vom Wikingerschatz aus Hiddensee über die Himmelsscheibe von Nebra bis hin zu Funden aus Ägypten langen. Der Fund von Bernstorf wird ausführlich diskutiert.
Various applications for artificial intelligence in the context of spectroscopy will be presented. in particular, examples from bamline will be featured. After a short introduction to synchrotron radiation, artificial intelligence algorithms for the quantification of X-ray fluorescence measurement are discussed. In the second example, information retrieval by natural language processing is reviewed. As a last example the reconstruction of measurements with the X-ray color camera and coded apertures is presented.
Trace elements are chemical elements whose concentration in a material is very low. The exact definition depends on the application and varies for example between 100 micrograms per gram in analytical chemistry and 1000 micrograms per gram in geology. The ability to detect trace elements fast and quantitatively is of great importance in many areas of science and technology. With its high brilliance and flexibility in the excitation conditions, synchrotron radiation is an ideal tool for detecting traces even in small sample quantities. In this contribution I will report about the use of X-ray fluorescence(XRF)for qualitative and quantitative element sensitiveanalysis. In addition to the fundamentals of XRF and its quantification methods, the advantages and problems of different geometries like e.g. microXRF, Total Reflection X-ray Fluorescence (TXRF)or Double Dispersive XRF (D²XRF) will be discussed. Practical examples from BAMline from the research fields of medicine, geology and archaeometry will complete the lecture.
In this work, we describe the use of artificial neural networks for the quantification of X-ray fluorescence measurements. The training data were generated using Monte Carlo simulation, which avoided the use of adapted reference materials. The extension of the available data set by means of an ANN to generate additional data was demonstrated. Particular emphasis was put on the comparability of simulated and experimental data and how the influence of deviations can be reduced. The search for the optimal hyperparameter, manual and automatic, is also described. For the presented case, we were able to train a network with a mean absolute error of 0.1 weight percent for the synthetic data and 0.7 weight percent for a set of experimental data obtained with certified reference materials.
To better study the impact of nanoparticles on both in vitro and in vivo models, tissue distribution and cellular doses need to be described more closely. Here silver nanoparticles were visualized in alveolar macrophages by means of synchrotron radiation micro X-ray fluorescence spectroscopy (SR-μXRF) with high spatial resolution of 3 × 3 μm2. For the spatial allocation of silver signals to cells and tissue structures, additional elemental labeling was carried out by staining with eosin, which binds to protein and can be detected as bromine signal with SR-μXRF. The method was compatible with immunostaining of macrophage antigens. We found that the silver distribution obtained with SR-μXRF was largely congruent with distribution maps from a subsequent laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) of the same tissue sites. The study shows a predominant, though not exclusive uptake of silver into alveolar macrophages in the rat lung, which can be modeled by a similar uptake in cultured alveolar macrophages. Advantages and limitations of the different strategies for measuring nanoparticle uptake at the single cell level are discussed.