6 Materialchemie
Filtern
Erscheinungsjahr
- 2020 (134) (entfernen)
Dokumenttyp
Referierte Publikation
- nein (134) (entfernen)
Schlagworte
- Nanoparticles (27)
- Electron microscopy (12)
- Particle size distribution (10)
- BAMline (9)
- Small angle scattering (8)
- Synchrotron (8)
- Applications (7)
- Geant4 (6)
- Laser-induced periodic surface structures (LIPSS) (6)
- MCS (6)
Organisationseinheit der BAM
- 6 Materialchemie (134)
- 6.1 Oberflächen- und Dünnschichtanalyse (40)
- 6.3 Strukturanalytik (27)
- 6.6 Physik und chemische Analytik der Polymere (27)
- 6.2 Material- und Oberflächentechnologien (20)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (17)
- 1 Analytische Chemie; Referenzmaterialien (8)
- 6.7 Materialsynthese und Design (7)
- 5 Werkstofftechnik (6)
- 9 Komponentensicherheit (6)
Eingeladener Vortrag
- nein (73)
The main outcomes of the EMPIR project nPSize are presented and the suitability of the new capabilities (e.g. reference materials, measurement procedures, VAMAS inter-laboratory comparisons) to be standardized and implemented in accredited analytical laboratories is discussed. Complementation and/or filling gaps of published and ongoing standardisation projects on size, shape and number concentration measurements under ISO/TC 229/JWG 2 are offered.
It is a well-known story that copolymers beside their molar mass distribution (MMD) can exhibit a functionality type distribution (FTD), a copolymer composition distribution (CCD), a monomer sequence distribution (MSD) and additionally different topologies within one sample. Small, often isobaric heterogeneities in topology or microstructure can usually not be simply separated chromatographically or distinguished by any common detector. Nowadays a wide range of different analytical separation techniques and multi-detection possibilities are available. The challenge consists in a clever combination of these techniques with a specific approach of data analysis. In this presentation different liquid chromatographic separation modes were combined with Electrospray Time-of-Flight mass spectrometry.
The online coupling allows the analysis of reconstructed ion chromatograms (RIC) of each degree of polymerization. While a complete separation often cannot be achieved, the derived retention times and peak widths lead to information on the existence and dispersity of heterogeneities in microstructure or topology, that are otherwise inaccessible This method is suitable to detect small differences in e. g. branching, topology, monomer sequence or tacticity and could potentially be used in production control of oligomeric products or other routinely done analyses to quickly indicate deviations from set parameters. Based on a variety of examples e.g. the topology elucidation of branched EO-PO copolymers, the possibilities and limitations of this approach were demonstrated.
The increasing enrichment of water bodies and soils with plastic waste leads to the accumulation of microscopic plastic particles, so-called microplastics (MP). There is an urgent need for analytical methods that help to identify and quantify MP. At present, mainly thermo-analytical and microscopic methods such as micro-infrared spectroscopy or micro-Raman are used for this purpose. The latter are usually tied to time-consuming sample enrichment and preparation, only small sample quantities (micrograms) can be examined and the evaluation of the obtained spectra can be demanding. In the context of this presentation, two approaches are presented which, via the multi-variate analysis of spectroscopic data, allow i) a new methodological approach to screening MP in contaminated soils and ii) an alternative evaluation of large (micro)-spectroscopic data sets.
First, a NIR spectroscopic method is presented which allows MP consisting of polyethylene, polyethylene terephthalate, polypropylene and polystyrene to be detected in the range of up to 0.5 mass percent. Due to short measurement times and robust technology, this approach has the potential, in contrast to thermo-analytical and micro-spectroscopic methods, to examine larger sample quantities with minimal pre-treatment.
The second approach deals with the evaluation of large data sets, as typically obtained as a result of micro-FTIR using modern FPA detectors. The micro-FTIR technique is based on the spectral recording, imaging and subsequent identification of vibration bands typical of synthetic polymers. The image data sets are large and contain spectra of numerous particles of natural and synthetic origin. Exploratory multivariate data analysis has been tested to complement existing approaches based on e.g. spectrum library searches. The core concept used was dimensionality reduction. The results not only represent an orthogonal method for checking the results obtained by an automated library search, but also revealed a group of spectra that were not recorded in the existing spectrum libraries.
The aim of the work presented was the evaluation of corrosion resistance
of various materials in geothermal Waters as a base to create a catalogue of suitable materials for applications in (not only) German geothermal power plants.
Users shall be enabled to have a basis for designing such facilities. High alloyed corrosion resistant alloys are suitable and do not cause copper or lead deposition. They shall be chosen for future design of the piping system, either in massive or in cladded form, if crevices formation with non-metallic materials can be prevented!
A detailed calorimetric and dielectric study on two epoxy-based nanocomposite system was performed employing bisphenol A diglycidyl ether (DGEBA) cured with diethylenetriamine (DETA) and methyl tetrahydrophtalic acid anhydride (MTHPA) aas the polymer matrix and taurine-modified MgAL layered double hydroxide (T-LDH) and boehmite as nanofiller. The molecular dynamics investigation revealed an intrinsic structural heterogeneity of the epoxy materials. Moreover the polymer/particle interphase was qualitatively and quantitavely investigated.
This presentation is structured in two parts: i) Hybrid metrology by combining SEM with AFM (N. Feltin) and ii) hybridization and corelative microscopy by SEM, STEM-in-SEM, TEM, EDS, Auger Electron Microscopy, TKD and more (D. Hodoroaba).
The first part is focused on the metrological part of the hybrid measurement SEM-AFM, the second part offers some further possibilities of correlative microscopy of nanoparticles based on practical examples.
To simulate the movement of the macroscopic magnetic moment in ferromagnetic systems under the influence of elevated temperatures, the stochastic version of the Landau-Lifshitz (LL) or the Landau-Lifshitz-Gilbert equation with a spin density of one per unit cell has to be used.
To apply the stochastic LL to micromagnetic simulations, where the spin density per unit cell is generally higher, a conversion has to be performed. OOMMF sample files MIF) are provided which can be used to determine the Curie temperature for the classical bulk magnets, iron, nickel and cobalt.
These files contain cell models for TOPAS/Geant4 and the inclusion of nano particles in particle scattering simulations. A simple spherical cell with nanoparticles can be generated in a fast manner. The user has the option to include the following organelles: nucleus, mitochondria, cell membrane. Additionally nanoparticles can be included in the cytosol and at the surface of the nucleus and/or the mitochondria.
The C++ classes in this repository extend the functionality of the TOPAS (http://www.topasmc.org/) Monte-Carlo program, which is itself a wrapper of the Geant4 MCS Toolkit (http://geant4.org). The sourcecode together with examples and scorers are provided.
"If you use this extension please cite the following literature:
Hahn, M.B., Zutta Villate, J.M. "Combined cell and nanoparticle models for TOPAS to study radiation dose enhancement in cell organelles." Sci Rep 11, 6721 (2021).
https://doi.org/10.1038/s41598-021-85964-2 "
Fluorides are well-known as wood preservatives. One of the limitations of fluoride-based wood preservatives is their high leachability. Alternative to current fluoride salts such as NaF used in wood protection are low water-soluble fluorides. However, impregnation of low water-soluble fluorides into wood poses a challenge. To address this challenge, low water-soluble fluorides like calcium fluoride (CaF2) and magnesium fluoride (MgF2) were synthesized as nanoparticles via the fluorolytic sol−gel synthesis and then impregnated into wood specimens. In this study, the toxicity of nano metal fluorides was assessed by termite mortality, mass loss and visual analysis of treated specimens after eight weeks of exposure to termites, Coptotermes formosanus. Nano metal fluorides with sol concentrations of 0.5 M and higher were found to be effective against termites resulting in 100% termite mortality and significantly inhibited termite feeding. Among the formulations tested, the least damage was found for specimens treated with combinations of CaF2 and MgF2 with an average mass loss less than 1% and visual rating of “1”. These results demonstrate the efficacy of low water-soluble nano metal fluorides to protect wood from termite attack.
Eine umfangreich ausgestaltete Trinkwasseraufbereitung als Multibarrieren-System ist notwendig, wenn das Rohwasser direkt aus Fließgewässern entnommen wird (z. B. für das Mülheimer Verfahren). Eine der Barrieren wird, als gezielte Behandlungs- oder Sicherheitsstufe, oft als Filter mit granulierter Aktivkohle (GAK-Filter) realisiert. Ihre Standzeit kann bei geringer Wasserbelastung (DOC < 2 mg/L), z. B. bei der Landeswasserversorgung Langenau, bis zu 5 Jahre betragen. Bei Rohwasser mit höherem Organikgehalt (DOC > 7 mg/L), wie bei der Nordwasser in Rostock, wird hingegen mindestens alle drei Jahre die GAK in den Filterkolonnen ausgetauscht.
Die Rest-Adsorptionskapazität der GAK kann durch verschiedene Verfahren abgeschätzt werden, ist aber nach wie vor Gegenstand aktueller Forschung. Die weitergehende Charakterisierung der beladenen GAK kann hierbei helfen.
Auf dem Poster sollen erste Ergebnisse zu den in Langenau und Rostock eingesetzten Aktivkohlen präsentiert werden. Hierzu wurden die frischen und nach unterschiedlichen Laufzeiten beladenen GAK untersucht. Die Zusammensetzung der Anorganik und der adsorbierten Organik, welche mittels Zersetzungs¬gasanalyse charakterisiert wurde, zeigt deutliche Unterschiede. Bspw. nimmt der Calcium-Gehalt der GAK in Langenau kontinuierlich zu, wohingegen dieser in den Proben aus Rostock mit zunehmender Laufzeit zurückgeht. Umgekehrt verhält es sich mit der Organik: Die GAK aus Rostock zeigen Hinweise auf biologische Besiedelung, während diese in Langenau trotz längerer Filterlaufzeit auszubleiben scheint.
In this work the flexural rigidity of individual large diameter multi-walled carbon nanotubes (MWCNTs) was investigated. The bending modulus were obtained by detecting the resonance frequencies of mechanically excited cantilevered carbon nanotubes using the so-called dynamic scanning electron microscopy technique, and applying the Euler–Bernoulli beam theory. For the nanotubes studied, we determined a modulus of up to 160 GPa. This agrees with values reported by other authors for MWCNTs produced by catalytic chemical vapor deposition, however, it is 6-8 times smaller than values reported for single and multi-walled carbon nanotubes produced by arc-discharge synthesis. Toxicological studies with carbon nanotubes have been showing that inhaled airborne nanofibers that reach the deep airways of the respiratory system may lead to serious, asbestos-like lung diseases. These studies suggested that their toxicity critically depends on the fiber flexural rigidity, with high rigidity causing cell lesions. To complement the correlation between observed toxicological effects and fiber rigidities, reliable and routinely applicable measurement techniques for the flexural rigidity of nanofibers are required.
Small-area/spot photoelectron spectroscopy (SAXPS) is a powerful tool for the investigation of small surface features like microstructures of electronic devices, sensors or other functional surfaces. For evaluating the quality of such microstructures, it is crucial to know whether a small signal in a spectrum is an unwanted contamination of the field of view (FoV), defined by the instrument settings, or it originated from outside. The aperture has a major influence on the signal-contribution from the outside. For the evaluation of the FoV, we determined the Au4f intensities measured with the center of the FoV aligned with the center of the spot and normalized to the Au4f intensity determined on the Au-film. With this test specimen, it was possible to characterize the FoV: The signal-contribution from the outside is reduceable down to lower than 50 %, when the aperture is 30 % of the structure dimension for our Kratos AXIS Ultra DLD system.
Small-area/spot photoelectron spectroscopy (SAXPS) is a powerful tool for the investigation of small surface features like microstructures of electronic devices, sensors or other functional surfaces. For evaluating the quality of such microstructures, it is crucial to know whether a small signal in a spectrum is an unwanted contamination of the field of view (FoV), defined by the instrument settings, or it originated from outside. The aperture has a major influence on the signal-contribution from the outside. For the evaluation of the FoV, we determined the Au4f intensities measured with the center of the FoV aligned with the center of the spot and normalized to the Au4f intensity determined on the Au-film. With this test specimen, it was possible to characterize the FoV: The signal-contribution from the outside is reduceable down to lower than 50 %, when the aperture is 30 % of the structure dimension for our Kratos AXIS Ultra DLD system.
The progress in activities on Microbeam Analysis under VAMAS/TWA 37 is reviewed. Particularly the liaison with the new projects within the ISO technical committee TC 202 is presented and discussed with respect to the possibility of identifying and launching related VAMAS projects. Need of more promotion for the engagement of more participants from industry and academia at national, European and international level is highlighted. Also, the competition with the other technical working areas (on 'nano' or materials-related) is critically discussed.
Gold nanocubes with a monodispersed size distribution (edge = 55 nm) deposited on a silicon wafer. These tiny uniform cubes were produced as reference nanoparticles within the EMPIR project nPSize - Improved traceability chain of nanoparticle size measurements. SEM image acquired at 10 kV with an in-lens secondary electron detector. Image colored in ImageJ using LUT “Orange hot.” Published in Microscopy and Microanalysis 25(S2) (2019) 2328.
Gold nanocubes with a monodispersed size distribution (edge = 55 nm) deposited on a silicon wafer. These tiny uniform cubes were produced as reference nanoparticles in the frame of the European project nPSize - Improved traceability chain of nanoparticle size measurements. SEM Image acquired at 10 kV with an in-lens secondary electron detector. Image colored in ImageJ using LUT “Orange hot.” Published in Microscopy and Microanalysis 25(S2) (2019) 2328.
Laser-induced periodic surface structures (LIPSS) are a universal phenomenon and can be generated on almost any material by irradiation with linearly polarized radiation. This chapter reviews the current state in the field of LIPSS, which are formed in a “self-ordered” way and are often accompanying materials processing applications. LIPSS can be produced in a single-stage process and enable surface nanostructuring and, in turn, adaption of optical, mechanical, and chemical surface properties. Typically, they feature a structural size ranging from several micrometers down to less than 100 nm and show a clear correlation with the polarization direction of the light used for their generation. Various types of LIPSS are classified, relevant control parameters are identified, and their material-specific formation mechanisms are analyzed for different types of inorganic solids, i.e., metals, semiconductors, and dielectrics. Finally, technological applications featuring surface functionalization in the fields of optics, fluidics, medicine, and tribology are discussed.