6 Materialchemie
Filtern
Dokumenttyp
- Vortrag (17)
- Sonstiges (2)
- Posterpräsentation (2)
- Forschungsbericht (1)
Referierte Publikation
- nein (22) (entfernen)
Schlagworte
- Reference materials (22) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (22)
- 6.1 Oberflächen- und Dünnschichtanalyse (14)
- 6.6 Physik und chemische Analytik der Polymere (10)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.0 Abteilungsleitung und andere (1)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 6.3 Strukturanalytik (1)
- 6.7 Materialsynthese und Design (1)
Since microplastics (MPs) can be found everywhere and are becoming a problem of high concern, it is necessary to understand their physico-chemical properties. To obtain reliable analytical data a set of validated methods for sampling, sample preparation, detection, and data evaluation are needed.
To meet these needs an interlaboratory comparison (ILC) with 84 participants worldwide has been organized under the international pre-standardisation platform VAMAS (www.vamas.org/twa45/) as Project 2 “Development of standardized methodologies for characterisation of microplastics with microscopy and spectroscopy methods” within the Technical Working Area TWA 45 “Micro and Nano Plastics in the Environment”. In this ILC thermo-analytical methods (Py-GC/MS and TED-GC/MS) and vibrational methods (µ-Raman and µ-FTIR) have been tested and compared by providing a set of microplastic representative test materials and measurement protocols developed at BAM. The defined measurands were: particle number concentration, particle size distribution (PSD), and polymer identity and mass content. To increase the statistical quality, 6 samples were shipped together with blank samples. Hence, the ILC provides information on precision and accuracy of the results obtained with different methods as well as strengths and limitations of the proposed protocols.
The talk summarizes challenges in microplastic analysis. It shows the preparation of microplastic reference materials as well as the testing on homogeneity and stability. The reference material is used in an international laboratory comparison to compare different detection methods used for microplastic analysis. The methods used were µ-IR (FTIR+LDIR) for number-based methods and TED-GC/MS and Py-GC/MS for mass-based methods. The ILC was done under the umbrella of VAMAS TWA 45. Results of the participants are presented.
Benchtop 1H-NMR and FTIR have both been successfully developed for size-exclusion chromatography (SEC) applications. The latest implementations of these methods by Wilhelm and collaborators[1-3] have taken advantage of commerically available low-cost equipment, and a provide a means to obtain slice-by-slice spectra for the monitoring of functional groups in polymer separations. Demonstrated applications include the detection of highly diluted chains in a polymer blend (e.g., PS/PMMA), copolymer content determination (e.g., styrene-methyl methacrylate), and butadiene isomer detection. To synthesize and characterize an end-labelled low molecular wt. poly(ethylene glycol) as a model polymer to aid in the development and validation of spectroscopic detection (FTIR and 1H-NMR) for SEC applications. A particular focus is to improve quantitation and/or detection of highly diluted funtional groups (e.g., polymer chain ends or sparsely functionalized chains) In the first approach, an isocyanate with IR- and NMR-active functional groups was reacted with PEG (4000 and 10000 g/mol) to form end-functionalized chains by means of an addition reaction. The functionalization of the 10000 g/mol PEG was found to be non-homogeneous (not discussed further). The 4000 g/mol PEG was successfully functionalized to 100%, found to be homogeneous across the molecular weight distribution and could therefore serve as a model polymer for analysis by the coupled methods.
The VAMAS/TWA 45 Project 2 “Development of standardized methodologies for characterisation of microplastics with microscopy and spectroscopy methods” involving 85 participants around the world is primarily discussed with respect to the results received and a first data evaluation. Status of the Project "Guidelines for defining reference materials for plastic degradation in marine environment" is reported and two new project proposals are presented: "Development of standardized methodologies for characterisation of nanoplastics (starting soon, BAM as leader?) and "Development of analytical protocols for the identification and quantification of microplastics of fibrous shape (still in negotiation)".
One aim of the EMPIR nPSize project 17NRM04 was to develop and validate three classes of candidate reference (test) materials (RTMs), with i) well-defined non-spherical shape, ii) relatively high polydispersity index, and iii) accurate particle concentrations.
To fulfil the requirements of the project, 11 different types of materials were prepared. Following the initial assessment of the materials suitability, nPSize5_PT_UNITO, nPSize6_AC_UNITO and nPSize7_GN_CEA materials were found unsuitable for the project, due to various reasons. PT material was deemed unsuitable due to its predominantly agglomerated nature. AC material contained relatively high amount of impurities (other particle forms). GN material was found too heterogeneous in both the length and width for the purpose of the project. The remaining 8 candidate RTMs were assessed for their homogeneity and stability and used for successful delivery of the associated activities within the nPSize project.
The unambiguous correlation of possible health and sustainability risks to nanoparticle size must be enabled by reliable measurement of nanoparticle size, to ensure comparability and compatibility between results measured under different methods. The NPSIZE project funded by European Metrology Program (EMPIR) develop methods, reference materials and modelling to improve the traceability chain, comparability and compatibility of nanoparticle size measurements. In this work, we present how spherical silica nanoparticles are synthetized with controlled monomodal or bimodal dispersion to be use as reference materials and international round-robin. Improving the fabrication requires a fine understanding of synthesis (1), coupled with an expertise of in-situ or ex-situ analysis methods. This is a new challenge for the analysis : determining not only average characteristics (size, chemical composition and shape ...) but also the concentration and the distribution over the population studied (2). Small-Angle X-ray Scattering (3) allows very precise measurements of the nanoparticles size and concentration that can be directly link to the metric system (4) (metrological traceability) . We developed a SAXS laboratory instrument dedicated to the in-situ characterization of nanoparticles, which enable fast measurements, and the monitoring of the synthesis parameters. Measurement protocols and software processing chain (5) (i.e. size distribution) are also combined & optimized.
Results from different methods applied to micro- and nanoplastics (MNPs) analysis show that there are large gaps in harmonisation with respect to terminology, size classes, sample preparation protocols and, finally, to the comparability of the measurands and descriptors.
Within the European research cluster to understand the health impacts of micro- and nanoplastics (CUSP) working group WG3-Inter-Laboratory Comparisons an overview of the existing detection methods revealing advantages and disadvantages regarding the analytical tasks is being compiled. There is a clear need to develop high class characterized reference materials for MNPs in the size ranges of 100-10 µm and smaller than 10 µm, so that these can be used to validate methods and to make results comparable. Inter-laboratory comparisons (ILCs) on model samples with complex matrices regarding mass, or water samples for number-based methods, will help us to advance the process of harmonization as well as to train users early in process of developing new methods.
We plan to keep all five CUSP projects well-connected also with the 'outside' MNP projects and ILCs and to extract the optimum of needs, capabilities, and efforts in order to launch new VAMAS ILCs which should expand already available ones.
Gold nanocubes with a monodispersed size distribution (edge = 55 nm) deposited on a silicon wafer. These tiny uniform cubes were produced as reference nanoparticles in the frame of the European project nPSize - Improved traceability chain of nanoparticle size measurements. SEM Image acquired at 10 kV with an in-lens secondary electron detector. Image colored in ImageJ using LUT “Orange hot.” Published in Microscopy and Microanalysis 25(S2) (2019) 2328.
Gold nanocubes with a monodispersed size distribution (edge = 55 nm) deposited on a silicon wafer. These tiny uniform cubes were produced as reference nanoparticles within the EMPIR project nPSize - Improved traceability chain of nanoparticle size measurements. SEM image acquired at 10 kV with an in-lens secondary electron detector. Image colored in ImageJ using LUT “Orange hot.” Published in Microscopy and Microanalysis 25(S2) (2019) 2328.
New reference material candidates for traceable size measurement of non-spherical nanoparticles
(2019)
New model nanoparticles with well-controlled shape were synthesized within the EMPIR project nPSize - Improved traceability chain of nanoparticle size measurements. Their systematic characterization takes place by the traceable methods scanning/transmission electron microscopy, atomic force microscopy and small angle X-ray scattering. Following reference nanoparticle candidates are under investigation with respect to their homogeneity and stability: titania nanoplatelets (10-15 nm x 50-100 nm), titania bipyramides (~60 nm x 40 nm), titania acicular particles (100 nm x 15-20 nm; aspect ratio 5.5/6), gold nanorods (~10 nm x 30 nm), and gold nanocubes (~55 nm x 55 nm x 55 nm).
Challenges in Traceable Size Measurement of Non-Spherical, Non-Monodisperse Nanoparticles - nPSize
(2019)
Size measurement of nanoparticles (NP) becomes a challenging analytical problem when non-spherical shapes must be traceably measured. However, most industrial NPs have irregular shapes and broad size distribution making it often more complex to follow European regulatory to identify a material as a nanomaterial according to which accurate measurement of the smallest dimension and its size Distribution is necessary.
The European research project nPSize - Improved traceability chain of nanoparticle size measurements aims to fill this gap by developing potential non-spherical reference nanoparticles, measurement procedures and physical modelling to improve the traceability chain, comparability and compatibility for NP size measurements between different methods. Therefore, new model NP with well-controlled shape has been synthesized and are supposed to be systematically characterized using the traceable methods scanning/transmission electron microscopy, atomic force microscopy and small angle X-ray scattering.
Following NP candidates are under investigation with respect to their homogeneity and stability: (i) titania nanoplatelets (10-15 nm thickness x 50-100 nm lateral), (ii) titania bipyramides (~60 nm length x 40 nm width), (iii) titania acicular particles (100 nm length x 15-20 nm width; aspect ratio 5.5/6), (iv) gold nanorods (~10 nm width x 30 nm length), and (v) gold nanocubes (~55 nm x 55 nm x 55 nm). In addition, sample preparation procedures as well as measurement analysis procedures with evaluation of appropriate measurands and descriptors for each material class and method are being developed to support standardization. To underpin the traceability of the size measurement of nonspherical NP, physical modelling of the signals in e.g. electron microscopy techniques will be used and in combination, the implementation of machine learning is aimed to facilitate measurement Analysis procedures, especially regarding the accurate thresholding/segmentation of the NPs.zeige mehr
Measurement of nanoparticle size (distribution) becomes a challenging analytical problem when non-spherical nanoparticles must be accurately measured. Most industrial nanoparticles have not only non-spherical shapes but also possess polydisperse size distributions, and due to their agglomeration/aggregation state are difficult (or even impossible) to be addressed individually. Moreover, driven by regulatory purposes related to the identification of a material as a nanomaterial, the accurate measurement of the smallest dimension of a (nano)particulate material makes the analysis even more complex.
In the first phase of the EU Project nPSize - Improved traceability chain of nanoparticle size measurements (https://www.bam.de/Content/DE/Projekte/laufend/nPSize/npsize.html), the efforts are focused on synthesis of nanoparticles of well-defined, non-spherical shape. Following candidates of reference materials (CRM) with certifiable particle size (distribution) are under characterization with respect to their homogeneity and stability: (i) titania nanoplatelets (10-15 nm thickness x 50-60 nm lateral), (ii) titania bipyramides (~60 nm length x 40 nm width), (iii) titania acicular particles (100 nm length x 15-20 nm width; aspect ratio 5.5/6), (iv) gold nanorods (~10 nm width x 30 nm length), and (v) gold nanocubes (~55 nm x 55 nm x 55 nm).
Das EMPIR-Förderprogramm wird kurz erläutert und laufende Projekte aus der Nanotechnologie werden vorgestellt. Der Schwerpunkt liegt auf Standardisierungsprojekten, die gemeinsam mit ISO/TC 229 'Nanotechnologies' und CEN/TC 352 'Nanotechnologies' zu neuen Normen führen sollten. Als Beispiel für laufende Nanotechnologie-Projekte mit Koordination aus Deutschland werden MagNaStand (PTB) und nPSize (BAM) gegeben.