6 Materialchemie
Filtern
Dokumenttyp
- Vortrag (45)
- Forschungsdatensatz (26)
- Video (5)
- Zeitschriftenartikel (4)
- Sonstiges (4)
- Posterpräsentation (3)
- Beitrag zu einem Tagungsband (2)
- Forschungsbericht (1)
Sprache
- Englisch (90)
Referierte Publikation
- nein (90) (entfernen)
Schlagworte
- X-ray scattering (43)
- MOUSE (28)
- SAXS (26)
- Small angle scattering (11)
- Methodology (10)
- Small-angle scattering (8)
- Data analysis (7)
- Nanomaterials (7)
- Software (7)
- Automation (6)
- Instrumentation (6)
- Lab automation (6)
- Analysis (5)
- Introduction (5)
- Nanostructure (5)
- Sample holder (5)
- Scattering (5)
- Simulation (5)
- XRD (5)
- Data stewardship (4)
- X-ray (4)
- Additive manufacturing (3)
- Data organization (3)
- Fourier transforms (3)
- Image manipulation (3)
- Laboratory management (3)
- PDF (3)
- Python (3)
- Round Robin (3)
- Round robin (3)
- Scicat (3)
- Scientific misconduct (3)
- Two-photon polymerization (3)
- WAXS (3)
- 3D Fourier Transform (2)
- Automated synthesis (2)
- Data conversion (2)
- Data corrections (2)
- Data management (2)
- Data manipulation (2)
- FFT (2)
- Fourier Transform (2)
- Framework (2)
- HDF5 (2)
- High resolution (2)
- Holistic experimental procedures (2)
- Holistic science (2)
- Interlaboratory comparison (2)
- Measurement data conversion (2)
- Metal organic framework (2)
- Monte Carlo (2)
- NXsas (2)
- Nanocharacterisation (2)
- Nanocomposite (2)
- Nanomaterial (2)
- Nanoparticles (2)
- Nanostructure investigation (2)
- Nanostructure quantification (2)
- NeXus (2)
- Neutron (2)
- Neutron scattering (2)
- Paper mills (2)
- Particle size distribution (2)
- Robotics (2)
- SANS (2)
- Saxs (2)
- Scattering pattern analysis (2)
- Scientific method (2)
- Scientific rigor (2)
- USAXS (2)
- X-ray diffraction (2)
- 2PP (1)
- 3D (1)
- 3D FFT (1)
- 3D printing (1)
- 3D-printing (1)
- 3d structuring (1)
- 60-230V (1)
- AFM (1)
- ATZ (1)
- Academic fraud (1)
- Academic metrics (1)
- Alkyls (1)
- Alumina toughened zirconia (1)
- Analyses (1)
- Analysis approach (1)
- Anhydrite (1)
- Application (1)
- Arbitrary shapes (1)
- Automated analysis (1)
- Automated data tagging (1)
- BAM Academy (1)
- Bad science (1)
- Biofilm (1)
- Boehmite (1)
- Bonse Hart (1)
- Calcium sulfate (1)
- Calibration structure (1)
- Catalysis (1)
- Causes leading to scientific misconduct (1)
- Ceramic microprinting (1)
- Ceramic nano particles (1)
- Channel access (1)
- Columnar ionic liquid crystals (1)
- Command line (1)
- Command-line interface (1)
- Conference (1)
- Correlative analysis (1)
- Data (1)
- Data analysis round robin (1)
- Data catalog (1)
- Data correction (1)
- Data curation (1)
- Data fitting (1)
- Data interpretation (1)
- Data mining (1)
- Data pipelines (1)
- Data processing (1)
- Data provenance (1)
- Data stewartship (1)
- Data tagging (1)
- Databases (1)
- Dataset merging (1)
- Datasets (1)
- Demonstration (1)
- Digital laboratory (1)
- Digitalization (1)
- Direct Laser Writing (1)
- EPICS (1)
- Electric Safety Interlock (1)
- Electron density map (1)
- FAIR (1)
- Faked research (1)
- Flow-through (1)
- Gas sorption (1)
- Graphitization (1)
- Graphs (1)
- Guideline (1)
- Heated (1)
- High Resolution (1)
- High-resolution (1)
- High-throughput (1)
- High-throughput measurements (1)
- History (1)
- Holistic experiment approaches (1)
- Human factor (1)
- Human influence (1)
- Image averaging (1)
- Images (1)
- Instrument automation (1)
- Instrument control (1)
- Instrumentation utilization (1)
- Intercomparability (1)
- Iron nanoparticles (1)
- Laboratory (1)
- Laboratory automation (1)
- Laboratory methodology (1)
- Laboratory organization (1)
- Large number of participants (1)
- Laser writing (1)
- Liquid crystals (1)
- MAUS (1)
- MOF (1)
- MPI (1)
- MPLS (1)
- Machine learning (1)
- Magnetic nano-particles (1)
- Magnetic swimmers (1)
- Materials science (1)
- McSAS (1)
- McSAS3 (1)
- Measurement data (1)
- Measurement methodology (1)
- Measurement organization (1)
- Measurement science (1)
- Mechanical testing (1)
- Membrane polymers (1)
- Mesocrystal (1)
- Metadata (1)
- Metadata collection (1)
- Metadata structuring (1)
- Metal organic frameworks (1)
- Metal-organic frameworks (1)
- Metrics (1)
- Metrics-driven science (1)
- Metrology (1)
- Microporous polymers (1)
- Microprinting (1)
- Monte carlo (1)
- Motor controller (1)
- Multi photon lithography (1)
- Multi-photon light structuring (1)
- Multi-scale (1)
- Multi-scale measurements (1)
- Multiphoton laser structuring (1)
- NFDI (1)
- Nano-ceramic-additive-manufacturing photoresin (1)
- Nano-particles alignment (1)
- NanoCAM (1)
- Neutron diffraction (1)
- OECD (1)
- Open access (1)
- Open data (1)
- Open science (1)
- Pair distribution function (1)
- Photon counting detectors (1)
- Pitfalls (1)
- Polydispersity (1)
- Polymer nanocomposite (1)
- Polymer nanocomposites (1)
- Polymers (1)
- Porous carbons (1)
- Practical aspects (1)
- Practical examples (1)
- Publication pressure (1)
- Quality (1)
- Quality infrastructure (1)
- REACH (1)
- Reference structure (1)
- Reliability (1)
- Reproducibility (1)
- Reproducibility crisis (1)
- Research Data Management (1)
- Research fraud (1)
- Robotic synthesis (1)
- Robotic-supported synthesis (1)
- RunDeck (1)
- SAXS/WAXS (1)
- SEM (1)
- STL file input (1)
- Sall-angle scattering (1)
- Sample cell (1)
- Scattering pattern (1)
- Scattering pattern simulation (1)
- SchwarzP cells (1)
- Scientific communication (1)
- Scientific fraud (1)
- Scientific rigour (1)
- Silver nanoparticle (1)
- Silver nanoparticles (1)
- Size distribution (1)
- Slurry (1)
- Small-angle Scattering (1)
- Small-angle X-ray scattering (1)
- Standardisation (1)
- Starch (1)
- Starch nanoparticle (1)
- Synthesis (1)
- Synthesis library (1)
- Systems architecture (1)
- TEM (1)
- TSEM (1)
- Test artifact (1)
- Test structure (1)
- Theory (1)
- Tools to combat scientific misconduct (1)
- Total scattering (1)
- Traceability (1)
- Traceability derivation (1)
- Transparency (1)
- Two photon polymerization (1)
- Two-Photon Polymerization (1)
- Uncertainties (1)
- Vacuum compatible (1)
- Video (1)
- Waxs (1)
- X-ray generation (1)
- X-ray instrumentation (1)
- X-ray science (1)
- Yttria-stabilized zirconia (1)
- automation (1)
- extension (1)
- instrument utilization (1)
- laboratory automation (1)
- laboratory management (1)
- metadata collection (1)
- module (1)
- research efficiency (1)
- stl code (1)
- technical drawings (1)
- total scattering (1)
- ultra-small-angle X-ray scattering (1)
Organisationseinheit der BAM
- 6 Materialchemie (90)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (88)
- 6.6 Physik und chemische Analytik der Polymere (11)
- 5 Werkstofftechnik (4)
- 6.0 Abteilungsleitung und andere (4)
- VP Vizepräsident (4)
- VP.1 eScience (4)
- 5.1 Mikrostruktur Design und Degradation (3)
- 6.3 Strukturanalytik (3)
- 1 Analytische Chemie; Referenzmaterialien (1)
Eingeladener Vortrag
- nein (45)
By automatically recording as much information as possible in automated laboratory setups, reproducibility and traceability of experiments are vastly improved. This presentation shows what such an approach means for the quality of experiments in an X-ray scattering laboratory and an automated synthesis set-up.
This presentation highlights ongoing scientific misconduct as found in academic literature. This includes data- and image manipulation, and paper mills. Starting with an expose of examples, it delves deeper into the causes and metrics driving this phenomenon. Finally a range of possible tools is presented, that the young researcher can use to prevent themselves from sliding into the dark scientific methods.
Trinamic TMCL IOC is a Python package designed for controlling stepper motors connected to a Trinamic board using the TMCL language (all boards supported by PyTrinamic should now work, has been tested on the TMCM 6110 and the TMCM 6214). Since it is implementing the TMCL protocol, it should be easy to adapt to other Trinamic motor controller boards. This package assumes the motor controller is connected over a machine network via a network-to-serial converter, but the underlying PyTrinamic package allows for other connections too.
This allows the control of attached motors via the EPICS Channel-Access virtual communications bus. If EPICS is not desired, plain Pythonic control via motion_control should also be possible. An example for this will be provided in the example.ipynb Jupyter notebook.
This package leverages Caproto for EPICS IOCs and a modified PyTrinamic library for the motor board control, and interfaces between the two via an internal set of dataclasses. Configuration for the motors and boards are loaded from YAML files (see tests/testdata/example_config.yaml).
The modifications to PyTrinamic involved extending their library with a socket interface. This was a minor modification that should eventually find its way into the official package (a pull request has been submitted).
This is a set of use examples for the HDF5Translator framework. This framework lets you translate measurement files into a different (e.g. NeXus-compatible) structure, with some optional checks and conversions on the way. For an in-depth look at what it does, there is a blog post here.
The use examples provided herein are each accompanied by the measurement data necessary to test and replicate the conversion. The README.md files in each example show the steps necessary to do the conversion for each.
We encourage those who have used or adapted one or more of these exampes to create their own conversion, to get in touch with us so we may add your example to the set.
Simulates X-ray and Neutron scattering patterns from arbitrary shapes defined by STL files.
Features:
- Uses multithreading to compute a number of independent solutions, then uses the variance of the results to estimate an uncertainty on the output.
- Can be launched from the command line using an excel sheet to define settings, or from a jupyter notebook.
- Outputs scattering patterns in absolute units if the contrast is set.
- A Gaussian size distribution is available, where the relative scaling of objects for each repetion can be varied. Recommended to be used with limited width (max. 10%) to avoid artefacts.
- Writes results with settings to an archival HDF5 file.
Application examples:
This software has been used in several studies to date. For example, it has been used here to simulate a model scattering pattern for a cuboid shape, which was then fed forward into the McSAS3 analysis program for analyzing scattering patterns of polydisperse cuboids. A second use is here, where it was used for the modeling of flattened helices. In this paper, scattering pattern features could be matched with particular morphological changes in the structure. Lastly, this paper has an example where it was used to validate the analytical analysis model, and explore the realistic limits of application of the analytical model.
OpenSCAD, STL and technical drawings for the capillary flow-through cell designed primarily for use with The MOUSE instruments.
This flow-through cell can be used in conjunction with:
- Modular sample holder (10.5281/zenodo.7499416)
- Solid sample rack/plate (10.5281/zenodo.7499424)
- Laser-cut sample holder (10.5281/zenodo.7499437)
Technical drawings and documents for building a compact, heated, vacuum compatible flow-through sample holder. This holder is in use at the BAM MOUSE instrument as well as at the I22 beamline at the Diamond Light Source (see references for instrument details).
This holder has several features:
- The holder can be used in vacuum environments as well as in atmosphere
- It has two G 1/4" UNF fittings to attach HPLC tubing for (optionally) flowing a medium through the sample cell
- There are two additional (unflowed) sample positions for backgrounds and calibrants, held at the same temperature
- The low-mass design coupled with a 250W heating element can achieve heating rates of 1 degree C per second, when coupled (for example) with an Omron E5CC PID controller.
- The sample holder insert can be made from various materials depending on the application. Sealing the sample from the vacuum can be achieved using kapton, teflon or Magic tape, depending on the temperature requirements. The inlet and outlet holes will need to be punctured with a needle to enable flow.
- Large exit cones ensure a clear exit angle of at least 45 degrees two theta.
- It has been tested with temperatures up to 400 degrees C.
- Compression area has been raised and polished to ensure a good vacuum seal.
OpenSCAD, STL and technical drawings for the solid sample rack designed primarily for use with The MOUSE instruments.
This solid sample rack can be used in conjunction with:
- Laser-cut sample holder (10.5281/zenodo.7499437)
- Modular sample holder (10.5281/zenodo.7499416)
- Capillary flow-cell for liquid samples (10.5281/zenodo.7499421)
PDF file for the laser-cut sample holder designed primarily for use with The MOUSE instruments.
This sample holder can be used in conjunction with:
- Solid sample rack/plate (10.5281/zenodo.7499424)
- Modular sample holder (10.5281/zenodo.7499416)
- Capillary flow-cell for liquid samples (10.5281/zenodo.7499421)
2PP-TestArtifact
(2023)
This repository contains a test artifact (TA), also called test structure, designed for two-photon polymerization (also known as Direct Laser Writing (DLW) or Two/Multi-photon lithography (2PA/MPA)). Test artifacts can be used to compare structures, to check options used by the slicer, check the state of the 2PP machine itself or to get a construction guidelines for a certain combination of power, velocity and settings.
The associated paper can be found here: https://dx.doi.org/10.1088/1361-6501/acc47a
General ideas behind the test artifact:
1. optimized for 2PP-DLW
2. should be fast and easy to analyse with optical microscopy or 3. scanning electron microscopy without tilt.
3. short time to fabricate
4. include a reasonable amount of different features
5. bulk and small structures on the substrate
This dataset is a complete set of raw, processed and analyzed data, associated with the manuscript mentioned in the title.
All associated metadata and processing history has been added. Particle size distribution analyses using McSAS are included as well.
The samples consisted of a 4.2 mass% dispersion of yttria-stabilized zirconia nanoparticles in a cross-linked matrix. The measurements show a good dispersion with minimal agglomeration. The wide-angle region shows diffraction information consistent with zirconia.
OpenSCAD, STL and technical drawings for the Modular sample holder designed primarily for use with The MOUSE instruments.
This modular sample holder can be used in conjunction with the following:
- Capillary flow-cell for liquid samples (10.5281/zenodo.7499421)
- Solid sample rack/plate (10.5281/zenodo.7499424)
- Laser-cut sample holder (10.5281/zenodo.7499437)
X-ray scattering datasets for samples described in the 2020 publication "Molecular Dynamics of Janus Polynorbornenes: Glass Transitions and Nanophase Separation". This dataset includes both raw and processed X-ray scattering data for samples PTCHSiO-Pr, Bu, Hx, Oc and De, alongside background measurements files (BKG). This data was collected using the MOUSE project (instrument and methodology).
X-ray scattering datasets for samples described in the 2022 publication "Molecular Mobility of Polynorbornenes with Trimethylsiloxysilyl side groups: Influence of the Polymerization Mechanism". This dataset includes both raw and processed X-ray scattering data for samples APTCN and MPTCN, alongside background measurements files (BKG).
X-ray scattering datasets for samples described in the 2022 publication "Side chain length dependent dynamics and conductivity in self assembled ion channels". This dataset includes both raw and processed X-ray scattering data for samples ILC8, ILC10, ILC12, ILC14 and ILC16 alongside background measurement files (BKG).
This talk introduces the expanded view that comes from wide-range X-ray scattering investigations.
Compared to X-ray diffraction studies alone, the additional angular range of this technique provides information on the larger structural dimensions present in your samples. This allows for the extraction of information on the size and size distribution of nanostructural components, such as nanoparticles, nanovoids, and any other structure exhibiting an electron density contrast.
The talk introduces the technique, the MOUSE instrument used for these investigations, and provides several real-world examples of its uses. The audience is invited to choose which examples captures their interest from a range of options, in the latter segment of the talk.
McSAS3
(2023)
McSAS3 is a refactored version of the original McSAS (see DOI 10.1107/S1600576715007347). This software fits scattering patterns to obtain size distributions without assumptions on the size distribution form. The refactored version has some neat features:
- Multiprocessing is included, spread out over as many cores as number of repetitions!
- Full state of the optimization is stored in an organized HDF5 state file.
- Histogramming is separate from optimization and a result can be re-histogrammed as many times as desired.
- SasModels allow a wide range of models to be used
- If SasModels does not work (e.g. because of gcc compiler issues on Windows or Mac), an internal sphere model is supplied
- Simulated data of the scattering of a special shape can also be used as a McSAS fitting model. Your models are infinite!
- 2D fitting also works.