6 Materialchemie
Filtern
Erscheinungsjahr
- 2020 (73) (entfernen)
Dokumenttyp
- Vortrag (73)
Referierte Publikation
- nein (73)
Schlagworte
- Nanoparticles (9)
- BAMline (8)
- Small angle scattering (7)
- Synchrotron (7)
- Electron microscopy (5)
- Geant4 (5)
- Geant4-DNA (5)
- MCS (5)
- Particle size distribution (5)
- XRF (5)
Organisationseinheit der BAM
- 6 Materialchemie (73)
- 6.1 Oberflächen- und Dünnschichtanalyse (21)
- 6.3 Strukturanalytik (16)
- 6.6 Physik und chemische Analytik der Polymere (14)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (11)
- 6.2 Material- und Oberflächentechnologien (7)
- 6.7 Materialsynthese und Design (5)
- 1 Analytische Chemie; Referenzmaterialien (3)
- 7 Bauwerkssicherheit (3)
- 9 Komponentensicherheit (2)
Eingeladener Vortrag
- nein (73) (entfernen)
Data quality is a vast term, which comprises the completeness, relevance (adequacy), and reliability of data. So far, many attempts to assure data quality have been pursued, and evaluation criteria for data quality have been established. One relatively novel but already well-known aspect of data quality refers to the concept of data FAIRness, which states that data should be: findable, accessible, interoperable and re-usable. In order to find, use, and access data, a user has to be guided properly. Such guidelines already exist for regulators and the scientific community. However, a ‘simple’ non-academic user from general society is very unlikely to be able to access or understand such data. Our objective in the H2020 project NANORIGO is to help and guide all types of users (i.e., scientists, regulators, industry workers, citizens, etc.) to access and make use of high-quality data and information from available and suitable data repositories in order to increase the transparency of and trust in nanotechnology.
Blueprint for a sustainable new European Centre to support safe innovation for nanotechnology
(2020)
This paper presents the blueprint for the operation of a sustainable and permanent European Centre of collaborating reference laboratories and research centres, to establish a one-stop shop for a wide variety of nanosafety related services, and to provide a central contact point for questions about nanosafety in Europe. The Centre aims to harmonise service provision, and bring novel risk assessment and management approaches closer to practice.
A brief introduction to the efforts we have done in our lab towards AI/ML analysis of SAXS data. For this, we need to extend the data with an extensive, structured hierarchy of metadata and associated data. A practical look into the information stored in our files, and the organization of the files in a data catalog is presented.
In the face of rising energy demand and the impending climate change the development of a sustainable, fossil-free fuel and chemical production is of global importance. One possible goal is the development of electrochemical conversion processes using catalysts. Porous materials play an important role in such energy applications. The key to the development of improved catalysts is a better understanding of the relations between their performance, stability and physico-chemical properties. However, the complex morphology of such catalysts constitutes a challenge even for modern analytical techniques. Spectroscopic ellipsometry (SE) is a versatile method for studying material properties by using appropriate models (e.g. film thickness, optical and electronic properties). The fact that the material properties cannot be taken directly from the measured spectra, the developed models have to be validated. In a first step, the model for the ellipsometric fit studies of a calcination series of mesoporous iridium oxide films (300 – 600 °C) was investigated and validated with respect to their material properties. Moreover, the electronic structures of the catalysts reveal a direct correlation with electrochemical activities. The development of an environmental cell offers the possibility of investigations under real conditions. This will allow changes in the optical and electronic properties during the electrocatalytic oxygen evolution reaction.
The European legislation has responded to the wide use of nanomaterials in our daily life and defined the term “nanoform” in the Annexes to the REACH (Registration, Evaluation, Authorization of Chemicals) Regulation. Now specific information of the nanomaterials is required from the companies when registering the appropriate materials in a dossier.
In the context of REACH eleven physicochemical properties were considered as relevant, of which the following six are essential for registration of nanoforms (priority properties): chemical composition, crystallinity, particle size, particle shape, chemical nature of the surface (“surface chemistry”), and specific surface area (SSA). A key role is the reliable, reproduceable and traceable character of the data of these priority properties.
In this context, we want to discuss which ‘analytical’ information is exactly required to fulfill these conditions. Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) and X-ray Photoelectron Spectroscopy (XPS) were chosen as the most popular surface analytical methods. Both methods allow a detailed understanding of the surface chemistry with an information depth below ten nanometers. As a rather bulk method for the analysis of nanoforms, Electron Probe Microanalysis (EPMA) in the version with energy dispersive X-ray spectroscopy (EDS) is considered for the quick identification of the main chemical elements present in the sample. Furthermore, Scanning Electron Microscopy (SEM) results are discussed which provide results on particle size and shape. Thus, four of the six priority properties can be obtained with these methods.
The main outcomes of the EMPIR project nPSize are presented and the suitability of the new capabilities (e.g. reference materials, measurement procedures, VAMAS inter-laboratory comparisons) to be standardized and implemented in accredited analytical laboratories is discussed. Complementation and/or filling gaps of published and ongoing standardisation projects on size, shape and number concentration measurements under ISO/TC 229/JWG 2 are offered.
It is a well-known story that copolymers beside their molar mass distribution (MMD) can exhibit a functionality type distribution (FTD), a copolymer composition distribution (CCD), a monomer sequence distribution (MSD) and additionally different topologies within one sample. Small, often isobaric heterogeneities in topology or microstructure can usually not be simply separated chromatographically or distinguished by any common detector. Nowadays a wide range of different analytical separation techniques and multi-detection possibilities are available. The challenge consists in a clever combination of these techniques with a specific approach of data analysis. In this presentation different liquid chromatographic separation modes were combined with Electrospray Time-of-Flight mass spectrometry.
The online coupling allows the analysis of reconstructed ion chromatograms (RIC) of each degree of polymerization. While a complete separation often cannot be achieved, the derived retention times and peak widths lead to information on the existence and dispersity of heterogeneities in microstructure or topology, that are otherwise inaccessible This method is suitable to detect small differences in e. g. branching, topology, monomer sequence or tacticity and could potentially be used in production control of oligomeric products or other routinely done analyses to quickly indicate deviations from set parameters. Based on a variety of examples e.g. the topology elucidation of branched EO-PO copolymers, the possibilities and limitations of this approach were demonstrated.
The increasing enrichment of water bodies and soils with plastic waste leads to the accumulation of microscopic plastic particles, so-called microplastics (MP). There is an urgent need for analytical methods that help to identify and quantify MP. At present, mainly thermo-analytical and microscopic methods such as micro-infrared spectroscopy or micro-Raman are used for this purpose. The latter are usually tied to time-consuming sample enrichment and preparation, only small sample quantities (micrograms) can be examined and the evaluation of the obtained spectra can be demanding. In the context of this presentation, two approaches are presented which, via the multi-variate analysis of spectroscopic data, allow i) a new methodological approach to screening MP in contaminated soils and ii) an alternative evaluation of large (micro)-spectroscopic data sets.
First, a NIR spectroscopic method is presented which allows MP consisting of polyethylene, polyethylene terephthalate, polypropylene and polystyrene to be detected in the range of up to 0.5 mass percent. Due to short measurement times and robust technology, this approach has the potential, in contrast to thermo-analytical and micro-spectroscopic methods, to examine larger sample quantities with minimal pre-treatment.
The second approach deals with the evaluation of large data sets, as typically obtained as a result of micro-FTIR using modern FPA detectors. The micro-FTIR technique is based on the spectral recording, imaging and subsequent identification of vibration bands typical of synthetic polymers. The image data sets are large and contain spectra of numerous particles of natural and synthetic origin. Exploratory multivariate data analysis has been tested to complement existing approaches based on e.g. spectrum library searches. The core concept used was dimensionality reduction. The results not only represent an orthogonal method for checking the results obtained by an automated library search, but also revealed a group of spectra that were not recorded in the existing spectrum libraries.
The aim of the work presented was the evaluation of corrosion resistance
of various materials in geothermal Waters as a base to create a catalogue of suitable materials for applications in (not only) German geothermal power plants.
Users shall be enabled to have a basis for designing such facilities. High alloyed corrosion resistant alloys are suitable and do not cause copper or lead deposition. They shall be chosen for future design of the piping system, either in massive or in cladded form, if crevices formation with non-metallic materials can be prevented!