Despite abundant evidence of the occurrence of microplastics (MP) – these are particles smaller 5 mm – in aquatic environments, little is known about the accumulation of plastic in terrestrial environments, especially in soils.
Possible major input pathways could be the use of plastic mulching, the use of compost, sewage sludge or residues from biogas facilities as fertilizers, as well as littering in urban areas. To estimate the MP pollution, the development of reliable, fast methods for sampling, sample preparation, and detection is needed. The obtained data must be representative of the sampled environmental compartment and measurements from different environmental compartments must be comparable. A first breakthrough is an application of ThermoExtractionDesorption-Gas Chromatography-MassSpectrometry (TED-GC-MS) for the detection of MP, including tire abrasives. This method allows the determination of mass content within a few hours and only a minimum of sample preparation for samples from aquatic environments is needed.
However, in contrast to filtrate samples from aquatic environments, sediment or soil samples need an enrichment of MP. Whereas MP concentration from marine sediments can be obtained by floatation and density Separation techniques using NaCl solutions, the extraction or separation from soils proves to be more difficult, as plastic particles are often part of organo-mineral aggregates within the soil matrix.
The aim of this study is the development of a practicable processing guideline for representatively taken soil samples in order to concentrate microplastics, without complex and time-consuming treatment steps. Dispersants or detergents can be applied to decompose the soil matrix, but each preparation step carries the risk of crosscontamination of the sample and prolongs the preparation procedure.
For this reason, we choose ZnCl2-solution with a density of 1.7 g/cm3, which include the densities of relevant MP types (0.9-1.7 g/cm3). It was tested to achieve both, disaggregation and separation as it decomposes organic material and dissolves carbonates. Also, ZnCl2 is inert to the precipitation of undesirable salts and Carbonates during the process of density separation, as polytungstate solution does. ZnCl2 can be reused after stepwise filtering (7 µm, 1.5 µm, 0.7 µm). Thus, disposal costs can be reduced. Efficiency and reproducibility of the sample preparation as well as the degradation behavior of MP under the present conditions were demonstrated with model samples.
Real sampling campaigns were conducted at several agricultural sites and floodplains in south-west Germany. The sampling was performed according to practice for soil sampling, using adequate sampling strategies (pattern of sampling, number of field samples, homogenization, etc). The lab sample was fractioned into three size classes (5-100 µm, 100-1000 µm, and 1-5 mm). The identification and determination of mass fraction were done using TED-GC-MS.
The ubiquitous presence of unwanted plastics in the environment, especially microscale particles, has been an issue in scientific studies and public debate in the last years. It is well known that oxidative degradation and subsequent fragmentation, caused by UV-radiation, oxidative aging and abrasion lead to the decomposition of larger plastic products into microplastics (MP). Possible effects of these MP on ecosystems are still unclear. Recent studies on MP findings are focused mainly on aquatic systems, while little is known about MP in terrestrial ecosystems.
A possible source of MP input into the soil is compost from domestic bio-waste. Inappropriate waste separation causes plastic fragments in the bio-waste, some of which end up in the compost. In Germany compost is used as fertilizer in agriculture, hence MP could enter the soil by this pathway. So far, there have been only a few studies on this object. For this reason, analysis of compost as a sink and source of MP in ecosystems is of high interest.
To estimate and monitor the MP content in compost and soil, fast and harmonised analytical methods are essential, which not only measure the polymer type and number of particles, but also the mass content. The most common spectroscopic methods are very time-consuming, often require complex sample preparation steps and cannot determine mass contents. Therefore, we used ThermoExtractionDesorption-GasChromatography-MassSpectrometry (TED-GC-MS) as a fast, integral analytical technique. The sample is pyrolyzed to 600°C in a nitrogen atmosphere and an excerpt of the pyrolysis gases is collected on a solid phase adsorber. Afterwards, the decomposition gases are desorbed and measured in a GC-MS system. Characteristic pyrolysis products can be used to identify the polymer type and determine the mass contents. This method is well established for the analysis of MP in water filtrate samples.
In the present work we optimized the TED-GC-MS method for compost and compost/soil matrix and very common polymers, such as polyethylene, polypropylene, polyethylene-terephthalate and polystyrene (sample mass, detection limits, interfering signals, etc.). Additionally, specific pyrolysis products of polymers used for bio-waste bags, such as polylactide (PLA) and polybutylenadipat-terephthalat (PBAT) had to be identified and evaluated.
First measurements were carried out on model and real samples from prepared mixtures and composting plant. The samples were sterilized, fractionated, filtered and dried. In addition, half of the sample material was treated with hydrogen peroxide to investigate a possible effect on detection.
Working towards a comprehensive understanding of introduction pathways, number, and fate of micro¬plastics in the environment, suitable analytical methods are a precondition. Micro-spectroscopic methods are probably the most widely used techniques. Besides their ability to measure single spectra of a particle or fiber, most modern FTIR- and Raman microscopes are also capable of two-dimensional imaging. This is very appealing to microplastics research because it allows to simultaneously characterize the analytes chemically as well as their size (distribution) and shape.
Two-dimensional imaging on extensive sample areas with FTIR-micros¬copes is facilitated by focal plane array (FPA) detectors resulting in large data sets comprised of up to several million spectra. With numbers too large for manual inspection of each individual spectrum, automated data evaluation is inevitable. Identifying different polymers based on the comparison with known reference spectra (library search) has proven to be a suitable approach. For that purpose, FTIR-spectra of common plastics can be collected to create an individual reference library.
To Supplement this ‘targeted analysis’, looking for known substances via library search, an exploratory approach was tested. Principal component analysis (PCA) proved to be a helpful tool to drastically reduce the size of the data set while maintaining the significant information. Subsequently, cluster analysis was used to find groups of similar spectra. Spectra found in different clusters could be assigned to different polymer types. The variation observed within clusters gives a hint on chemical variability of microplastics of the same polymer found in the sample. Spectra labeled according to the respective cluster/polymer type were used to build a classification model which allowed to quickly predict the polymer type based on the FTIR spectrum. Classification was tested on a second, independent data set and results were compared to the spectral library search procedure.
Due to the favorable properties of polymers, their production and thus their input into the environment has increased significantly in recent decades. Currently, FTIR or Raman spectroscopy are mainly applied for the analysis of microplastic particles (MP) in environmental samples. However, these methods have great difficulties in determining metrologically traceable MP values, especially with regard to the limiting values, as preferred in regulation. Therefore, we developed a systematic and fast thermoanalytical method called TED-GC-MS (thermal extraction desorption gas chromatography mass spectrometry), which determines mass contents. Now the current goal is the determination of its process parameters.
This poster illustrates the theoretical requirements for MP analysis (left side) and contrast them with the current state of research (right side).Unexpected practical problems are presented and the relatively new method is discussed concerning the quality requirements of well-established methods such as LC-or GC-MS.