6 Materialchemie
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (44) (entfernen)
Schlagworte
- Laser-induced periodic surface structures (LIPSS) (4)
- Cement (3)
- Femtosecond laser ablation (3)
- Haftfestigkeit (3)
- Laser-induced X-ray emission (3)
- Luftgekoppelte Ultraschallprüfung (3)
- Phased Array (3)
- Surface functionalization (3)
- Aktivkohle (2)
- Applications (2)
- Atomic force microscopy (2)
- Early hydration (2)
- Ferroelektret (2)
- Hydrogen (2)
- Imaging ellipsometry (2)
- Klebfestigkeit (2)
- Polycarboxylate ether (PCE) (2)
- Radiation protection (2)
- Thermoakustik (2)
- Thermogravimetrie (2)
- Ultraschallwandler (2)
- AISI 304L (1)
- ALD-Hybridprozesse (1)
- Abwasserinfrastruktur (1)
- Adhäsion (1)
- Adsorption (1)
- Al2O3-Schichten (1)
- Alkali-activated materials (1)
- Alkaliaktivierte Bindemittel (1)
- Analytische Zentrifuge (1)
- Anatase (1)
- Atomic Layer Deposition (1)
- Austenitic stainless steel (1)
- Bacteria (1)
- Bauteilmonitoring (1)
- Beanspruchung auf Zug und Druck (1)
- Biofilm (1)
- Biofilms (1)
- Biofuels (1)
- Biogene Schwefelsäurekorrosion (1)
- Brechungsindex (1)
- C3A (1)
- C3A hydration (1)
- Carbamazepin (1)
- Cement hydration (1)
- Chalcopyrite (1)
- Change in tensile properties (1)
- Cladding-doped fibers (1)
- Coherent Fourier scatterometry (1)
- Corrosion (1)
- Cu(In,Ga)Se2 (1)
- DEA (1)
- DET (1)
- DNA (1)
- Defects (1)
- Definition of nanomaterial (1)
- Delayed addition (1)
- Diffusion (1)
- Dosimetry (1)
- Dye (1)
- Electron irradiation (1)
- Electron irradiation of DNA (1)
- Electron microscopy (1)
- Ellipsometrie (1)
- Epitaxially grown 4H-SiC layers (1)
- Ettringen tuff (1)
- Faser-Bragg Gitter (1)
- Finite-difference time-domain calculations (1)
- Fließmittel (1)
- Fluorescent optical fibers (1)
- Force distance curve (1)
- Fs-laser patterning (1)
- Geant4 (1)
- Generische Kenngrößen (1)
- Haftvermittler (1)
- High-entropy alloy (1)
- High-temperature resistance (1)
- Hydration (1)
- Hydrothermal synthesis (1)
- Hydroxyl radicals (1)
- Härteprüfung (1)
- Imaging modifizierter Oberflächen (1)
- Kleb- und Haftfestigkeit (1)
- LET (1)
- Laser processing (1)
- Laser-induced forward transfer (1)
- Linear energy transfer (1)
- Low energy electrons (1)
- MPI (1)
- MPLS (1)
- Magnetic swimmers (1)
- Magneto-optischer Sensor (1)
- Magnetostriktive Beschichtung (1)
- Mapping modifizierter Oberflächen (1)
- Mechanical stress (1)
- Mehr-Proben-Prüfung (1)
- Mehrprobenprüfung (1)
- Messtechnik (1)
- Messunsicherheit (1)
- Micro solar cell (1)
- Microdosimetry (1)
- Microplastics (1)
- Mikroskaliert (1)
- Müller-Matrix-Ellipsometrie (1)
- Nanoparticles (1)
- Nanoskaliert (1)
- Nitric acid (1)
- Oberflächenenergie (1)
- Oberflächengeometrie (1)
- Oberflächentechnik (1)
- One-part geopolymers (1)
- Optical Spectroscopy (1)
- Oxidation (1)
- PMMA (1)
- Plastic optical fibers (1)
- Polycarboxylate ether (1)
- Polycarboxylatether (1)
- Polydopamine (1)
- Polzmethyl methacrylate (1)
- Pore structure (1)
- Ppolyethylene (1)
- Proximatanalyse (1)
- Prüftechnik (1)
- Qualitätssicherung (1)
- Radiation damage (1)
- Regulation (1)
- Reparatursysteme (1)
- Rheologie (1)
- Rhodamine B (1)
- Scanning kelvin probe force microscopy (1)
- Sealing materials (1)
- Secondary hazard (1)
- Selbstkalibrierung (1)
- Shape-controlled (1)
- Silicon carbide (1)
- Silver nanoparticle (1)
- Solution doping (1)
- Spectroscopic Ellipsometry (1)
- Starch (1)
- Starch nanoparticle (1)
- Sulfuric acid resistance (1)
- Surface oxidation (1)
- Thin Solid Layers (1)
- Titanium dioxide (1)
- ToF-SIMS (1)
- Tribology (1)
- Two-Photon Polymerization (1)
- UV exposure (1)
- Ultra-short pulse laser processing (1)
- Ultrashort laser material interaction (1)
- Ultrashort pulse laser processing (1)
- Water samples (1)
- Weathering (1)
- Weibern tuff (1)
- Wetting (1)
- White light interference microscopy (1)
- Wide bandgap compound semiconductor (1)
- X-ray optics (1)
- Zementleim (1)
- Zentrifugentechnologie (1)
- Zersetzungsgasanalyse (1)
- shape control (1)
Organisationseinheit der BAM
- 6 Materialchemie (44)
- 6.1 Oberflächen- und Dünnschichtanalyse (11)
- 6.6 Physik und chemische Analytik der Polymere (11)
- 6.2 Material- und Oberflächentechnologien (10)
- 7 Bauwerkssicherheit (9)
- 7.4 Baustofftechnologie (8)
- 6.7 Materialsynthese und Design (7)
- 6.3 Strukturanalytik (5)
- 8 Zerstörungsfreie Prüfung (5)
- 9 Komponentensicherheit (4)
In Glasfasern eingeschriebene Bragg-Gitter (FBG: fibre-based Bragg gratings) sind über die Verschiebung der Bragg-Wellenlänge in der Lage, Stauchungen und Dehnungen von Glasfasern hochgenau zu erfassen. In Kompositwerkstoffe eingebettete faseroptische Sensoren können Bauteile bezüglich ihrer mechanischen Integrität überwachen und früh-zeitig Informationen über Materialveränderungen gewinnen.
Um die Zuverlässigkeit eines solchen Sensors zu gewährleisten, ist es wichtig, die korrekte Funktion des Sensors im Verbund mit der Werkstoff-Matrix on-line und in-situ sicherzu-stellen. Im Rahmen des DFG-Projekts FAMOS² (FAser-basierter Magneto-Optischer SchichtSensor) wurde ein selbstdiagnosefähiger Schichtsensor entwickelt, der mit Hilfe von magnetostriktiven Aktorschichten aus Nickel bzw. Eisen-Nickel validiert werden kann.
Der FAMOS²-Schichtsensor wird durch ein PVD (physical vapour deposition)/ECD (electro-chemical deposition) Hybridschichtsystem realisiert, das auf dem Fasermantel im Bereich des FBG haftfest, homogen und langzeitfunktional abzuscheiden ist. Dabei wird in einem ersten Schritt ein etwa 100 Nanometer dünnes PVD-Schichtsystem aus Chrom und Kupfer als Haftvermittler auf der Glasfaser bzw. als leitfähige Startschicht für den nachfolgenden ECD-Prozess abgeschieden. Um eine rotationssymmetrische Schich-tabscheidung zu gewährleisten, erfolgt während der PVD-Beschichtung eine Rotation der Glasfasern. In einem zweiten Schritt wird dann unter Verwendung eines klassischen Watts-Elektrolyten in einer speziell entwickelten ebenfalls rotationssymmetrisch aufgebau-ten ECD-Durchströmungszelle dann die etwa 30 Mikrometer dicke, magnetostriktive Ak-torschicht auf dem PVD-Schichtsystem abgeschieden, im Vergleich sowohl reine Nickel-Schichten als auch Nickel-Eisen-Schichten.
Ein äußeres Magnetfeld dehnt die magnetostriktive Aktorschicht und damit auch die Faser reversibel. Diese Dehnung führt zu einer Verschiebung der Bragg-Wellenlänge, welche direkt mit der Stärke eines zu messenden oder zu Validierungszwecken vorgegebenen Magnetfeldes korreliert. Die Anpassung der Beschichtungsverfahren an die Fasergeome-trie und die mechanischen Eigenschaften der Hybridschichten werden hinsichtlich der me-chanischen Integrität des faseroptischen Sensors diskutiert und der Nachweis der Selbst-diagnosefähigkeit erbracht.
Solution doping of off-the-shelf plastic optical fibers (POFs) represents rather simple and cheap way for preparing custom cladding-doped POFs (CD-POFs) with short to medium lengths. CD-POFs are especially attractive for environmental sensing applications, but might be of interest for illumination task as well. In this work, the proposed doping technique is tested with three different commercial low-cost polymethyl methacrylate (PMMA) POFs; Eska CK-40 and Eska GK-40 from Mitsubishi Rayon and Raytela PGU-FB1000 from Toray. The aim of the work is to aid the selection of the most suitable fiber yielding highest optical quality of prepared CD-POFs. Firstly, the optimal doping times are determined for the individual fiber types using short fiber samples. Secondly, longer 10 m CD-POFs are prepared from all tested fibersusing the optimized doping procedure. Finally, attenuation of pristine POFs and prepared CD-POFs is measured using optical time domain reflectometry in order to characterize the impacts of the doping on fiber optical properties. In addition, the importance of post-doping drying procedure for CD-POF optical performance is investigated as well. The results suggest that, although doping of all tested fibers is generally feasible, Eska CK-40 is the most suitable candidate with regard to the Doping efficiency and fiber post-doping performance.
The damage caused by ionizing radiation to DNA and proteins is the reason to treat cancer by radiation therapy. A better understanding of the molecular processes and quantification of the different damaging mechanisms is the prerequisite to develop more efficient therapies. Hereby the understanding of the processes involved in the damage to DNA are of key interest due to its central role in reproduction and mutation.
For radiation with low linear energy transfer (LET), most of the damage is caused by the secondary particles produced by scattering of the ionizing radiation with water. Thereby a multitude of species are produced, whereby especially kinetic low energy electrons, prehydrated electrons, OH-radicals and ions are of importance. With higher LET the relative amount of the direct damaging effects increases. This is especially important considering the increased usage of high LET nucleons in radiation therapy. Therefore, the quantification of the contribution to DNA damage of direct and indirect effects and the different secondary species is of high interest due to the increase of radio biological efficiency when applying high LET radiation.
Here we present an approach to investigate the relative contributions to DNA strand break yield for radiation of different LET within a single electron microscope in combination with electron scattering simulations.
During the energy transformation from fossil fuels to renewable energy sources, the use of hydrogen as fuel and energy storage can play a key role. This presents new challenges to industry and the scientific community alike. The storage and transport of hydrogen, which is nowadays mainly realized by austenitic stainless steels, remains problematic, which is due to the degradation of mechanical properties and the possibility of phase transformation by hydrogen diffusion and accumulation. The development of materials and technologies requires a fundamental understanding of these degradation processes. Therefore, studying the behavior of hydrogen in austenitic steel contributes to an understanding of the damage processes, which is crucial for both life assessment and safe use of components in industry and transportation. As one of the few tools that is capable of depicting the distribution of hydrogen in steels, time-of-flight secondary ion mass spectrometry was conducted after electrochemical charging. To obtain further information about the structural composition and cracking behavior, electron-backscattered diffraction and scanning electron microscopy were performed. Gathered data of chemical composition and topography were treated employing data fusion, thus creating a comprehensive portrait of hydrogen-induced effects in the austenite grade AISI 304L. Specimens were electrochemically charged with deuterium instead of hydrogen. This arises from the difficulties to distinguish between artificially charged hydrogen and traces existing in the material or the rest gas in the analysis chamber. Similar diffusion and permeation behavior, as well as solubility, allow nonetheless to draw conclusions from the experiments.
Mit der Zentrifugentechnologie ist seit einigen Jahren ein neuartiges Mehr-Proben-Prüf-verfahren auf dem Markt etabliert, welches die klassische Zugprüfung in den Trommelrotor einer Tischzentrifuge überträgt. In der Beanspruchung auf Zug ist die Prüfung der Verbundfestigkeit seit 2017 nach DIN EN ISO/IEC 17025 akkreditiert, wobei die Verbundfestigkeit von Klebungen direkt bestimmt wird und in Abhängigkeit von den Versagensformen Rückschlüsse auf die Klebfestigkeit von Klebstoffen/Klebebändern oder die Haftfestigkeit von Beschichtungen gezogen werden können.
Bei der zerstörenden Beanspruchung auf Zug ist zu beachten, dass es sich bei der Verbundfestigkeit um eine Systemeigenschaft handelt, d.h. nicht nur die chemischen und topografischen Oberflächeneigenschaften, sondern auch die plasto-elastischen Volumeneigenschaften des Klebstoffes und der Fügeteile haben Einfluss auf die ermittelten Kennwerte. Dabei ist eine qualitative Bestimmung der Versagensformen und Bruchbilder nach DIN EN ISO 10365 zwingend erforderlich, um eine Aussage über die Art des Versagens treffen zu können.
Mit der Erweiterung der Zentrifugentechnologie um Beanspruchungen auf Druck wurde dann der Nachweis erbracht, dass auch die klassische Härteprüfung in einer Zentrifuge als Mehr-Proben-Prüfung durchgeführt werden kann. Im Verbundvorhaben QUO VADIS PLUS werden derzeit invasive Beanspruchungen auf Druck zur Bestimmung der Härte von Materialien, der Kompressibilität von Metallschäumen sowie der Kompaktierbarkeit von Pulvern untersucht, was das Anwendungspotential der Zentrifugentechnologie nochmals erweitert. Dazu gehören auch kombinierte Beanspruchungen wie Zug-Scher- und Druck-Scher-Prüfungen.
Die Verbundfestigkeit von CFK-Platten in Abhängigkeit der Beanspruchungsart (Zug vs. Zug-Scher) bzw. der Faserorientierung (0°, 45°, 90°), die Klebfestigkeit von Klebstoffen bzw. Klebebändern auf unterschiedlichen Fügeteilwerkstoffen in Abhängigkeit von der Vorbehandlung, die Haftfestigkeit optischer Schichten auf Kunststoffen, die Bestimmung der Vickers-, Brinell- bzw. Kugeldruck-Härte sowie die Kompressibilität von metallischen Schäumen und Federn werden als ausgewählte Beispiele diskutiert.
Light concentration opens up the path to enhanced material efficiency of solar cells via increased conversion efficiency and decreased material requirement. For true material saving, a fabrication method allowing local growth of high quality absorber material is essential. We present two scalable fs-laser based approaches for bottom-up growth of Cu(In,Ga)Se2 micro islands utilizing either site-controlled assembly of In(,Ga) droplets on laser-patterned substrates during physical vapor deposition, or laser-induced forward transfer of (Cu,In,Ga) layers for local precursor arrangement. The Cu(In,Ga)Se2 absorbers formed after selenization can deliver working solar devices showing efficiency enhancement under light concentration.
Die Rheologie von fließfähigen zementären Systemen mit Fließmitteln wird durch eine Vielzahl parallel stattfindender Effekte beeinflusst. Zu diesen Effekten zählen Wechselwirkungen zwischen den Polymeren und Ionen in der Porenlösung, frühe Phasenbildung, zeitabhängige und kompetitive Adsorption zwischen anionischen Polymeren und Sulfationen, Bildung von Phasen in der Porenlösung sowie Morphologieänderungen an Partikeloberflächen. Die frühe Hydratation von Zement, die durch Lösungs- und Fällungsprozesse angetrieben wird, beeinflusst diese Effekte erheblich. Das permanente Ungleichgewicht der Porenlösung führt zu Veränderungen der Partikeloberflächen, welches widerum zur Folge hat, dass rheometrische Messungen dieser Zementleime anfällig für Streuungen sind. Um die Einflüsse aus der Zementhydratation zu minimieren, wurden die rheometrischen Untersuchungen mit Zement in Porenlösung durchgeführt. Die Experimente wurden mit verschiedenen Feststoffvolumenfraktionen durchgeführt und mit den Ergebnissen identischer Systeme mit Wasser anstelle von Porenlösung verglichen. Zusätzlich wurden die gleichen Systeme mit Zugabe von Polycarboxylatethern untersucht.
Die Ergebnisse zeigen, dass die Leime mit Wasser niedrigere Werte für Fließgrenze und plastische Viskosität aufweisen, als die Systeme mit Porenlösung. Während die Polymere eine Verminderung der Fließgrenze zur Folge hatte, war die Wirkung von Polymeren auf die plastische Viskosität vernachlässigbar. Zusätzlich wurde die frühe Hydratation unter Verwendung von Wärmeflusskalorimetrie, Rasterelektronenmikroskopie und Nadeleindringtiefe beobachtet.
The presence of polycarboxylate ether (PCE) based superplasticizers (SPs) has an enormous influence on the early hydration of cement. The hydration is retarded and the timing of formation and the morphology of hydrates is affected. This short paper presents experimental results about the influence of delayed Addition time of PCE SPs on hydration of cement and tricalcium aluminate (C3A) pastes, investigated by isothermal heat flow calorimetry. For cement pastes the hydration is retarded with SP, whereby the high charge PCE has a stronger retarding effect than the low charge PCE. With delayed PCE addition the cement shows a less retarded setting than with simultaneous addition. The alteration caused by PCE is much more pronounced for C3A and gypsum mixes than for cement. If the SP is added simultaneous, the exothermic peak of C3A is retarded. However, with delayed addition of SP the hydration is shortened, the gypsum depletion is fastened and the exothermic peak occurs less retarded or even accelerated compared to simultaneous addition. It is obvious that for C3A pastes there is less retardation the later the Addition of SP. Furthermore, the PCE alter the hydration of C3A when added delayed and exhibit changes in kinetics and hydration rates. The rate of reaction in the second stage is lower, discernible in decreased slopes and broader peaks. Besides this, a distinct ramp in the C3A heat flow curves within the first stage of C3A hydration occurs for all pastes with delayed addition of SP, which suggests an accelerated ettringite formation.
In this contribution the mechanisms of formation and current applications of LIPSS are reviewed, including the colorization of technical surfaces, the control of surface wetting properties, the mimicry of the natural texture of animal integuments, the tailoring of surface colonization by bacterial biofilms, and the improvement of the tribological performance of nanostructured metal surfaces.
Organic/inorganic mixtures were prepared from ordinary Portland cement (OPC), water (w/c 0.22), a fluorescent dye in aqueous solution (stable at alkaline pH; BAM-I), and two different comb shape polycarboxylates (PCEs), i.e., high charge (PCE-HC) and low charge (PCE-LC), respectively. Rheological and calorimetric measurements were performed prior to optical studies in order to select PCE concentrations. Absorption and fluorescence spectroscopy of the system OPC + BAM-I (CBAM-I) revealed maxima of dye BAM-I located at 645 nm and 663 nm, respectively. In presence of PCE-HC and PCE-LC, these mixtures displayed a small red shift in reflectance and a faster decrease in intensity compared to studies with CBAM-I; however, only slight differences were observed between the different PCEs. With time, all systems exhibited a decrease in intensity of BAM-I in absorption/reflectance and emission. This could be caused by dye adsorption and possibly decomposition when in contact with cement particles or hydration products.