6 Materialchemie
Filtern
Dokumenttyp
- Vortrag (809)
- Posterpräsentation (333)
- Zeitschriftenartikel (95)
- Forschungsdatensatz (82)
- Beitrag zu einem Tagungsband (35)
- Sonstiges (27)
- Forschungsbericht (15)
- Buchkapitel (12)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (7)
- Video (6)
Sprache
- Englisch (1255)
- Deutsch (179)
- Mehrsprachig (2)
- Spanisch (2)
Referierte Publikation
- nein (1438) (entfernen)
Schlagworte
- Nanoparticles (122)
- XPS (71)
- SAXS (66)
- Mechanochemistry (56)
- Mikroplastik (56)
- X-ray scattering (52)
- SEM (48)
- Automation (46)
- Electron microscopy (46)
- Laser-induced periodic surface structures (LIPSS) (46)
Organisationseinheit der BAM
- 6 Materialchemie (1438)
- 6.1 Oberflächen- und Dünnschichtanalyse (402)
- 6.6 Physik und chemische Analytik der Polymere (367)
- 6.3 Strukturanalytik (293)
- 6.2 Material- und Oberflächentechnologien (163)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (140)
- 6.0 Abteilungsleitung und andere (120)
- 6.7 Materialsynthese und Design (92)
- 1 Analytische Chemie; Referenzmaterialien (74)
- 4 Material und Umwelt (61)
- 5 Werkstofftechnik (44)
- 7 Bauwerkssicherheit (42)
- 4.1 Biologische Materialschädigung und Referenzorganismen (41)
- 9 Komponentensicherheit (30)
- 8 Zerstörungsfreie Prüfung (29)
- 1.2 Biophotonik (24)
- 7.4 Baustofftechnologie (20)
- 5.1 Mikrostruktur Design und Degradation (19)
- 5.4 Multimateriale Fertigungsprozesse (19)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (19)
- 6.4 Materialinformatik (18)
- VP Vizepräsident (17)
- VP.1 eScience (17)
- 1.9 Chemische und optische Sensorik (16)
- 9.5 Tribologie und Verschleißschutz (16)
- 4.2 Material-Mikrobiom Wechselwirkungen (15)
- 1.4 Prozessanalytik (13)
- 9.0 Abteilungsleitung und andere (13)
- 8.5 Röntgenbildgebung (10)
- 1.8 Umweltanalytik (9)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (8)
- 1.3 Instrumentelle Analytik (7)
- 8.6 Faseroptische Sensorik (7)
- 1.1 Anorganische Spurenanalytik (6)
- 8.4 Akustische und elektromagnetische Verfahren (6)
- 1.7 Organische Spuren- und Lebensmittelanalytik (5)
- 3 Gefahrgutumschließungen; Energiespeicher (5)
- 4.3 Schadstofftransfer und Umwelttechnologien (5)
- 1.5 Proteinanalytik (4)
- MP Mitglied des Präsidiums (4)
- PST Präsidiale Stabsstelle (4)
- 3.2 Gefahrguttanks und Unfallmechanik (3)
- 7.6 Korrosion und Korrosionsschutz (3)
- 8.0 Abteilungsleitung und andere (3)
- 9.2 Versuchsanlagen und Prüftechnik (3)
- 1.0 Abteilungsleitung und andere (2)
- 4.0 Abteilungsleitung und andere (2)
- 5.2 Metallische Hochtemperaturwerkstoffe (2)
- 5.3 Polymere Verbundwerkstoffe (2)
- 5.6 Glas (2)
- P Präsident (2)
- P.0 Präsident und andere (2)
- 2 Prozess- und Anlagensicherheit (1)
- 2.1 Sicherheit von Energieträgern (1)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (1)
- 3.6 Elektrochemische Energiematerialien (1)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (1)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 5.0 Abteilungsleitung und andere (1)
- 5.5 Materialmodellierung (1)
- 7.1 Baustoffe (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- MP.0 Mitglied des Präsidiums und andere (1)
Laser-induced periodic surface structures (LIPSS) enable a large variety of different surface functionalizations for applications in the fields of optics, fluidics, tribology, or medicine. Moreover, high spatial frequency LIPSS (HSFL) provide an appealing and straightforward way for the generation of surface nanostructures featuring spatial periods even below 100 nm – far beyond the optical diffraction limit. However, the imposed surface functionalities are usually caused by both, topographic and chemical surface alterations. For exploring these effects in detail, multi-method characterization was performed here for HSFL processed on Ti-6Al-4V alloy upon irradiation with near-infrared ps-laser pulses (1030 nm wavelength, ~1 ps pulse duration, 1 – 400 kHz pulse repetition rate) under different scan processing conditions. The subsequent sample characterization involved morphological and topographical investigations by scanning electron microscopy (SEM), atomic force microscopy (AFM), stylus profilometry (SP), as well as near-surface chemical analyses by X-ray photoelectron spectroscopy (XPS), hard X-ray photoelectron spectroscopy (HAXPES) and depth-profiling time-of-flight secondary ion mass spectrometry (TOF-SIMS). The results allow to qualify the laser ablation depth, the geometrical HSFL characteristics and provide detailed insights into the depth extent and the nature of the ps-laser-induced near-surface oxidation arising from the laser-processing in ambient air and into the relevance of heat-accumulation effects at high pulse repetition rates. Moreover, the direct comparison of the HAXPES and XPS data reveals the role of surface-covering organic contaminants adsorbed from the ambient atmosphere without ion-sputter depth profiling. Furthermore, reduction of the oxides by sputtering can be avoided.
Advances in ultrafast laser manufacturing: nanostructures, thin films, and scaling perspectives
(2024)
Advanced ultrafast laser technology is a rapidly growing field that currently enables many new industrial and scientific applications. During the last decades, this has been significantly driven by the availability of high-repetition-rate laser sources and novel beam delivery concepts. At the laser side, Moore’s law equally manifests for ultrafast laser technologies, since the average output power of such lasers doubles approximately every two years. This development is mainly driven by the increase of the pulse repetition rates of energetic laser pulses, currently enforcing the development of smart beam control and novel scanning strategies for preventing heat-accumulation and plasma-shielding effects during laser-based materials processing. This keynote presentation addresses the advantages, recent developments, and perspectives of laser processing with ultrashort laser pulses. A special focus is laid on the tailored structuring of thin films as well as the manufacturing and probing of sub-diffraction surface nanostructures – an ongoing race to extreme scales. Current limitations are identified and an outlook to future scaling perspectives will be provided.
Solvent-free sample preparation offers some advantages over solvent-based techniques, such as improved accuracy, reproducibility and sensitivity, for matrix-assisted laser desorption/ionization (MALDI) analysis. However, little or no information is available on the application of solvent-free techniques for the MALDI analysis of polymer blends. Solvent-free sample preparation by ball milling was applied with varying sample-to-matrix ratios for MALDI time-of-flight mass spectrometry analysis of various polymers, including polystyrenes, poly(methyl methacrylate)s and poly(ethylene glycol)s. The peak intensity ratios were compared with those obtained after using the conventional dried droplet sample preparation method. In addition, solvent-assisted milling was also applied to improve sample homogeneities.
Depending on the sample preparation method used, different peak intensity ratios were found, showing varying degrees of suppression of the signal intensities of higher mass polymers. Ball milling for up to 30 min was required to achieve constant intensity ratios indicating homogeneous mixtures. The use of wet-assisted grinding to improve the homogeneity of the blends was found to be disadvantageous as it caused partial degradation and mass-dependent segregation of the polymers in the vials.The results clearly show that solvent-free sample preparation must be carefully considered when applied to synthetic polymer blends, as it may cause additional problems with regard to homogeneity and stability of the blends.
The presentation demonstrates an application of multi-scale optical imaging methods such as spectroscopic imaging ellipsometry and white light interference microscopy for the investigation of wide-bandgap semiconductors for power electronics. The capabilities of these methods for the development of new reference calibration samples for scanning microwave microscopes (SMM) and conductive atomic force microscopes (C AFM) are discussed.
Interactions between a polymer and a substrate interface play a vital role in understanding the improvement in thin film material properties as well as serving as a model for nanocomposites. For any non-repulsive polymer-substrate interactions, polymer segments form an irreversibly adsorbed layer and show a slowdown in the glassy dynamics and thus an increase in the thermal glass transition temperature compared to the bulk-like values. The growth kinetics of the adsorbed layer showed a deviation for both poly (bisphenol-A carbonate) (PBAC) and polysulfone (PSU), two bulky polymers containing a functional group (phenyl ring) in the backbone, compared to conventional polymers previously studied like poly-2-vinyl pyridine (P2VP). This deviation was attributed to the bulkiness of the phenyl rings. . Further investigations into the influence of the adsorbed layer on glassy dynamics were conducted. The molecular mobility and glass transition for thin films of PBAC and PSU were compared to bulk samples of each polymer. Broadband dielectric spectroscopy, atomic force microscopy, and ellipsometry were primarily used and additionally supported by sum frequency generation spectroscopy.
This is a set of use examples for the HDF5Translator framework. This framework lets you translate measurement files into a different (e.g. NeXus-compatible) structure, with some optional checks and conversions on the way. For an in-depth look at what it does, there is a blog post here.
The use examples provided herein are each accompanied by the measurement data necessary to test and replicate the conversion. The README.md files in each example show the steps necessary to do the conversion for each.
We encourage those who have used or adapted one or more of these exampes to create their own conversion, to get in touch with us so we may add your example to the set.
Glycolide was polymerized in bulk by means of four different ROPPOC catalysts: tin(II) 2-ethylhexanoate (SnOct2), dibutyltin bis(pentafluoro-phenoxide) (BuSnOPF),zinc biscaproate (ZnCap), and zinc bis(pentafluoro-phenyl sulfide) (ZnSPF). The temperature was varied between 110 and 180°C and the time between 3 h and 7 days. For the few polyglycolides (PGAs) that were soluble extremely high molecular masses were obtained. The MALDI TOF mass spectra had all a low signal-to-noise ration and displayed the peaks of cyclic PGAs with a“saw-tooth pattern ”indicating formation of extended-ring crystallites in the mass range below m/z 2500. The shape of DSC curves varied considerably with catalyst and reaction conditions, whereas the long-distance values measured by SAXS were small and varied little with the polymeriza-tion conditions.
A corrosion study is performed on six variations of titanium grade 5 (Ti6Al4V) samples. Samples are prepared in different conditions by variation of preanodization, postanodization, and picosecond-laser (ps-laser) surface treatment, while polished and anodized samples serve as reference. Microcones and nanosized periodic surface features are successfully produced on Ti6Al4V samples. The morphology and topography of the structures are visualized by scanning electron microscopy and white light interference microscopy. Furthermore, the relative electrochemically active surface area (ECSA) is determined for the ps-laser-treated samples. It is determined that the preanodized and laser-treated sample has 3.5 times larger ECSA than a polished sample, and that the laser-treated sample has 4.1 times larger area. Moreover, Tafel analysis is performed to determine the corrosion properties of the samples. It is shown that the corrosion resistance improves for both laser-structured samples after the anodization. To further study the surface of the samples, electrochemical impedance spectroscopy measurements are conducted. The study indicates that the ps-laser-treated and anodized Ti6Al4V is suitable to be used for the fabrication of bone screws and plates due to its improved corrosion resistance as compared to nonanodized samples.