5 Werkstofftechnik
Filtern
Erscheinungsjahr
- 2018 (70) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (70) (entfernen)
Sprache
- Englisch (70) (entfernen)
Schlagworte
- Residual stress (6)
- Additive manufacturing (4)
- 3D-Printing (3)
- EBSD (3)
- High temperature corrosion (3)
- Microstructure (3)
- Additive Manufacturing (2)
- Aging (2)
- Bacteria (2)
- Calcination (2)
- Creep (2)
- Damage (2)
- Degradation (2)
- Glass (2)
- IN718 (2)
- Laser ablation in liquid (2)
- Nanoparticles (2)
- Neutron diffraction (2)
- Particle morphology (2)
- Plastic deformation (2)
- Reaction-sintering (2)
- Selective laser melting (2)
- Steel (2)
- TEM (2)
- Titanium oxide (2)
- 3D printing (1)
- 3D-finite element modeling (1)
- Accelerated temporal integration (1)
- Advanced wastewater treatment (1)
- Ageing (1)
- Al-Cu-Li-alloy (1)
- Alloys (1)
- Alumina coatings (1)
- Aluminium alloys (1)
- Aluminum alloy (1)
- Aluminum alloys (1)
- Amorphization (1)
- Amorphous silica (1)
- Annealing (1)
- Aquifer (1)
- BTEX (1)
- Biaxial strength (1)
- Bimodal distribution (1)
- Binder jetting (1)
- Bio Ceramic (1)
- Biogeochemistry (1)
- Bitter technique (1)
- Bone regeneration (1)
- Borosilicate glass (1)
- Bravais lattice (1)
- Brown-rot fungi (1)
- CCS (1)
- CCUS, supercritical/dense phase CO2, carbon steels, martensitic steel, superaustenite steel, droplet corrosion (1)
- Calcium Cobaltite (1)
- Calcium cobaltite (1)
- Carbon steel (1)
- Carbon storage (1)
- Ccs (1)
- Ceramic (1)
- Chemometrics (1)
- Co2-Storage (1)
- Coating (1)
- Cobald based alloy (1)
- Coniophora puteana (1)
- Coordinate measurement machine (1)
- Corrosion (1)
- Corrosion Fatigue (1)
- CrN/NbN (1)
- Crack healing (1)
- Crack propagation (1)
- Creep mechanisms (1)
- Critical energy release rate (1)
- Crystallographic texture (1)
- Cupriavidus metallidurans (1)
- Deformation (1)
- Dentine (1)
- Destabilization (1)
- Diffraction contrast (1)
- Diffusion (1)
- Digital image correlation (1)
- Dislocation (1)
- Dynamic recrystallization (1)
- EFTEM (1)
- Early stages (1)
- Efficiency (1)
- Electric conductivity (1)
- Electrical resistance (1)
- Electron back-scattered diffraction (1)
- Electron microscopy (1)
- Enamel (1)
- End of life (1)
- Environmental stress cracking (ESC) (1)
- Environmentally assisted cracking (1)
- Epoxy resin (1)
- Expanding cavity model (1)
- FIB Tomography (1)
- Failure rate (1)
- Femtosecond laser (1)
- Fiber-matrix interface (1)
- Filters (1)
- Finland (1)
- Fluoride nanoparticles (1)
- Fluorolytic sol−gel (1)
- Fourier series (1)
- Fourier transform infrared spectroscopy (1)
- Fracture mechanics (1)
- Friction (1)
- Friction stir processing (1)
- Full notch creep test (FNCT) (1)
- Fungi (1)
- GMR (1)
- GMR sensors (1)
- Geometrical factors (1)
- Glass capillaries (1)
- Glass crystallization stress (1)
- Glass transition (1)
- Glass-ceramics definition (1)
- Gold (1)
- Grade S960QL steel (1)
- Gradient-enhanced fatigue model (1)
- Grain Boundary Corrosion (1)
- Graphite (1)
- Heat treatment (1)
- High Cycle Fatigue (1)
- High interstitial austenitic steel (1)
- High-temperature corrosion (1)
- Hipims (1)
- Hot isostatic pressing (HIP) (1)
- Hydrogen storage (1)
- Impact wear (1)
- In situ diffraction (1)
- In-situ SEM micro shear deformation (1)
- Inconel 625 (1)
- Indentation (1)
- Indentation hardness (1)
- Interdiffusion (1)
- Interface (1)
- Interfacial shear strength (1)
- Internal Sulfidation (1)
- Internal friction (1)
- Kikuchi pattern (1)
- Laboratory X-ray diffraction (1)
- Laser scanning microscopy (LSM) (1)
- Lattice parameters (1)
- Lifetime prediction (1)
- Light curing (1)
- Log-normal distribution (1)
- Long-term calculation (1)
- Low carbon steel (1)
- Magnetic domain distribution (1)
- Magnetic stray field (1)
- Magnetic stray fields (1)
- Magnetomechanical effect (1)
- Mars (1)
- Martensite (1)
- Martensitic transformation (1)
- Mass transport (1)
- Master curve (1)
- Material modeling (1)
- Metal Magnetic Memory (1)
- Metal magnetic memory (1)
- Microplastics (1)
- Microsegregation (1)
- Microstructur (1)
- Microstructure and texture (1)
- Microstructure evolution (1)
- Microwave technology (1)
- Misorientation (1)
- Mobility (1)
- Modeling (1)
- Molecular dynamics (1)
- Multiaxial deformation (1)
- Multilayer (1)
- NGS (1)
- Nano-scratch test (1)
- Nanoparticle structure (1)
- Nanoscale multilayers (1)
- Natural silver wires (1)
- Near Infrared Spectroscopy (1)
- NiTi (1)
- Notch (1)
- Number density (1)
- Optical centrifugation (1)
- Orientation (1)
- Orientation refinement (1)
- Oxidation (1)
- Oxide coatings (1)
- Oxyfuel (1)
- PLS-DA (1)
- PV modules (1)
- Passive components and circuits (1)
- Permeability (1)
- Phase-field (1)
- Photocleavable organosilanes (1)
- Photopolymer composites (1)
- Phototrophs (1)
- Photovoltaic modules (1)
- Phytolith (1)
- Polymer (1)
- Polymer matrix composites (1)
- Polymeric Materials (1)
- Polypropylene (1)
- Polystyrene (1)
- Porcelain (1)
- Porosity (1)
- Powdered activated carbon (1)
- Power factor (1)
- Preceramic polymer (1)
- Precipitation (1)
- Pressure-assisted sintering (1)
- Production scatter (1)
- Pull-out composite materials (1)
- Raman spectroscopy (1)
- Real-time qPCR (1)
- Relaxation (1)
- Resistance stress (1)
- Rhodonia placenta (1)
- Roughness (1)
- S-Phase (1)
- SEM (1)
- SEM wood characterization (1)
- SLM (1)
- Safety assessment (1)
- Sand blasting (1)
- Scanning acoustic microscopy (SAM) (1)
- Scanning electron microscopy (1)
- Scanning transmission electron microscopy (STEM) (1)
- Segregation (1)
- Self-Assembly (1)
- Sewage treatment plant (1)
- Shape memory alloys (1)
- Shear load (1)
- Shear testing (1)
- Single crystal superalloys (1)
- Single fiber pull-out test (1)
- Sliding simulation (1)
- Slow crack growth (SCG) (1)
- Slurry optimization (1)
- Soil (1)
- Solar panels (1)
- Solid-State-Synthesis (1)
- Solid-state-synthesis (1)
- Sorption (1)
- Spray drying (1)
- Steam oxidation resistance (1)
- Steel P92 (1)
- Stereoscopy (1)
- Strain difference (1)
- Stress-strain-behavior (1)
- Structural steel (1)
- Sulfidation (1)
- Sulphidation (1)
- Superalloy single crystals (1)
- Superconducting magnet (1)
- Support configurations (1)
- Support vector machines (1)
- Surface modification (1)
- Surface nucleation (1)
- Synchrotron X-ray diffraction (1)
- T1 precipitate (1)
- TIG-welding (1)
- Thermal expansion (1)
- Thermo-mechanical loading (1)
- Thermoanalysis (1)
- Thermoelectric oxide (1)
- Thermoelectric oxides (1)
- Thermoelectrics (1)
- Thermogravimetry (1)
- Thickening (1)
- Thin tribofilm (1)
- Titanium (1)
- Tooth wear (1)
- Topography (1)
- Transmission electron microscopy (1)
- Transmittance (1)
- Tricalcium Phosphate (1)
- Vacancies (1)
- Vickers indentation (1)
- Viscoplasticity (1)
- Visualization (1)
- Volume fraction (1)
- Water (1)
- Water droplet erosion resistance (1)
- Wood protection (1)
- X-ray computed tomography (CT) (1)
- Young`s modulus (1)
Organisationseinheit der BAM
- 5 Werkstofftechnik (70) (entfernen)
A wide range of solid-state synthesis routes for calcium manganate is reported in the literature, but there is no systematic study about the influence of the solid-state synthesis conditions on thermoelectric properties. Therefore, this study examined the influence of calcination temperature and calcination cycles on the Seebeck coefficient, electrical conductivity, and thermal conductivity. Higher calcination temperatures and repeated calcination cycles minimized the driving force for sintering of the synthesized powder, leading to smaller shrinkage and lower densities of the sintered specimens. As the electrical conductivity increased monotonously with increasing density, a higher energy input during calcination caused deterioration of electrical conductivity. Phase composition and Seebeck coefficient of sintered calcium manganate were not influenced by the calcination procedure. The highest thermoelectric properties with the highest power factors and figures of merit were obtained by means of reaction-sintering of uncalcined powder.
Effects of various geometrical and physical factors, as well as the method of data reduction (analysis of
experimental forceedisplacement curves) on the values of local interfacial strength parameters (local IFSS, td, and critical energy release rate, Gic) determined by means of a single fiber pull-out test are discussed. Experimental results of our pull-out tests on several fiberepolymer matrix systems showed that td and Gic weakly depended on geometrical factors. However, the pull-out test appeared to be sensitive to the conditions of specimen formation and testing, such as changing the nature of the contacting surfaces (fiber sizing) and the fiber pull-out rate. Of several methods of td and Gic Determination from a forceedisplacement curve, the most reliable and reproducible one is the approach based on the values of the maximum force recorded in a pull-out test and the interfacial frictional force immediately after fiber debonding.
Materials subjected to high-temperature service conditions will change their microstructure with time. Associated with this aging process is a change of mechanical properties as well as a change of damage mechanisms. Within the scope of the FVV project Aging and Lifetime, Fraunhofer IWM in Freiburg and BAM in Berlin (both Germany) experimentally characterized the widespread high-temperature aluminum alloy EN AW-2618A in different overaging states. Based on the experimental findings, models for numerical lifetime assessment with the finite-element method were implemented.
We invented the first non-metallic, self-adhesive and dry biosignalling electrode. The PEDOT polymer electrode changes its aggregate state and conductivity by a light curing procedure. The electrode can be applied as a gel underneath hair without shaving. With the aid of blue light, the electrode can be hardened within a few seconds at the desired location on the scalp. The cured polymer electrode is highly conductive and can be applied on a very small location. Unlike other EEG electrodes, our electrode does not lose conductivity upon drying. Furthermore, our electrode strongly bonds to Skin and does not require any additional adhesive. Short circuits due to an outflow of gel are prevented with this technique. Therefore, the PEDOT polymer electrode is extremely well suited for applications that, up to now, have been challenging, such as non-invasive EEG recordings from awake and freely moving animals, EEG recordings from preterm babies in the neonatal intensive care unit or long-term recordings in the case of sleep monitoring or epilepsy diagnostics. We addressed two technical questions in this work. First, is the EEG recorded with polymer electrodes comparable to a standard EEG? Second, is it possible to record full-band EEGs with our electrodes?
A femto-second pulsed laser ablation in liquid (PLAL) procedure for the generation of titanium oxide nanoparticles (NP) is reported with the purpose of understanding morphology and structure of the newly generated NPs. Ablation duration was varied for optimization of NP generation processes between 10 and 90 min. Surface morphology of NPs as well as their size and shape (distribution) were analysed by various complementary electron microscopy techniques, i.e. SEM, TSEM and TEM. The crystalline structure of titanium oxide particles was investigated by XRD(two instruments operated in different geometries) and HR-TEM. Concentration of generated titanium oxide NPs in liquid was analysed by ICP-MS. A mix of crystalline (mainly anatase), partly crystalline and amorphous spherical titanium oxide NPs can be reported having a mean size between 10 and 20 nm, which is rather independent of the laser ablation (LA) duration. A second component consisting of irregularly shaped, but crystalline titanium oxide nanostructures is co-generated in the LA water, with more pronounced occurrence at longer LA times. The provenance of this component is assigned to those spherical particles generated in suspension and passing through the converging laser beam, being hence subject to secondary irradiation effects, e. g. fragmentation.
This study examines the relationship between the magnetic mesostructure with the microstructure of low carbon steel tungsten inert gas welds. Optical microscopy revealed variation in the microstructure of the parent material, in the heat affected and fusion zones, correlating with distinctive changes in the local magnetic stray fields measured with high spatial resolution giant magneto resistance sensors. In the vicinity of the heat affected zone high residual stresses were found using neutron diffraction.
Notably, the gradients of von Mises stress and triaxial magnetic stray field modulus follow the same tendency transverse to the weld. In contrast, micro-X-ray fluorescence characterization indicated that local changes in element composition had no independent effect on magnetic stray fields.
It is widely accepted that the magnetic state of a ferromagnetic material may be irreversibly altered by mechanical loading due to magnetoelastic effects. A novel standardized nondestructive testing (NDT) technique uses weak magnetic stray fields, which are assumed to arise from inhomogeneous deformation, for structural health monitoring (i.e., for detection and assessment of damage). However, the mechanical and microstructural complexity of damage has hitherto only been insufficiently considered. The aim of this study is to discuss the phenomenon of inhomogeneous “self-magnetization” of a polycrystalline ferromagnetic material under inhomogeneous deformation experimentally and with stronger material-mechanical focus. To this end, notched specimens were elastically and plastically deformed. Surface magnetic states were measured by a three-axis giant magnetoresistant (GMR) sensor and were compared with strain field (digital image correlation) and optical topography measurements. It is demonstrated that the stray fields do not solely form due to magnetoelastic effects. Instead, inhomogeneous plastic deformation causes topography, which is one of the main origins for the magnetic stray field formation. Additionally, if not considered, topography may falsify the magnetic signals due to variable lift-off values. The correlation of magnetic vector components with mechanical tensors, particularly for multiaxial stress/strain states and inhomogeneous elastic-plastic deformations remains an issue.
Different imaging techniques were employed to monitor Full Notch Creep Test (FNCT) experiments addressing environmental stress cracking in more detail. The FNCT is a well-established test method to assess slow crack growth and environmental stress cracking of polymer materials, especially polyethylene. The standard test procedure, as specified in ISO 16770, provides a simple comparative measure of the resistance to crack growth of a certain material based on the overall time to failure when loaded with a well-defined mechanical stress and immersed in a liquid medium promoting crack propagation.
Destructive techniques which require a direct view on the free fracture surface, such as light microscopy and laser scanning microscopy, are compared to non-destructive techniques, i.e. scanning acoustic microscopy and xray micro computed tomography. All methods allow the determination of an effective crack length. Based on a series of FNCT specimens progressively damaged for varied Durations under standard test conditions, the estimation of crack propagation rates is also enabled. Despite systematic deviations related to the respective Imaging techniques, this nevertheless provides a valuable tool for the detailed evaluation of the FNCT and its further development.
Wollastonite (CaSiO 3 ) – diopside (CaMgSi 2 O 6 ) glass-ceramic scaffolds have been successfully fabricated using two different additive manufacturing techniques: powder-based 3D printing (3DP) and digital light processing (DLP), coupled with the sinter-crystallization of glass powders with two different compositions. The adopted manufacturing process depended on the balance between viscous flow sintering and crystallization of the glass particles, in turn in fluenced by the powder size and the sensitivity of CaO – MgO – SiO 2 glasses to surface nucleation. 3DP used coarser glass powders and was more appropriate for low temperature firing (800 – 900 °C), leading to samples with limited crystallization. On the contrary, DLP used finer glass powders, leading to highly crystallized glass-ceramic samples. Despite the differences in manufacturing technology and crystallization, all samples featured very good strength-to-density ratios, which bene fit theiruse for bone tissue engineering applications. The bioactivity of 3D-printed glass-ceramics after immersion in simulated body fluid and the similarities, in terms of ionic releases and hydroxyapatite formation with already validated bioactive glass-ceramics, were preliminarily assessed.
Tricalcium phosphate (b-TCP) can be used as bone graft, exhibiting suitable bioabsorption and osteoconduction properties. The presence of silica may induce the formation of a hydroxyapatite layer, enhancing the integration between implant and bone tissue. Preceramic polymers present silicon in their composition, being a source of SiO2 after thermal treatment. Using the versatility of 3D printing, b-TCP and a polysiloxane were combined to manufacture a bulkb-TCP with a silica coating. For the additive manufacturing process, PMMA powder was used as passive binder for the b-TCP particles, and polymethylsilsesquioxane (MK), dissolved in an organic solvent, was used both as a printing binder (ink) and as the source of SiO2 for the coating. Five distinct coating compositions were printed with increasing amounts of MK. The structures were then submitted to heat treatment at 1180 °C for 4 h. XRD and FTIR showed no chemical reaction between the calcium phosphate and silica. SEM allowed observation of a silicon-based ating on the structure surface. Mechanical strength of the sintered porous structures was within the range of that of trabecular bones.