5 Werkstofftechnik
Filtern
Dokumenttyp
- Posterpräsentation (99) (entfernen)
Sprache
- Englisch (99) (entfernen)
Referierte Publikation
- nein (99)
Schlagworte
- Glass (6)
- Additive manufacturing (5)
- Degradation (5)
- Microstructure (5)
- Additive Manufacturing (4)
- Coarsening (4)
- Corrosion (4)
- Crack growth (4)
- Creep (4)
- FAIR (4)
- Transmission electron microscopy (4)
- 316L (3)
- Ab-initio (3)
- Alloy 2618A (3)
- EBSD (3)
- Fatigue (3)
- Hydrogen (3)
- NTE (3)
- Nanoparticles (3)
- Soda-lime silicate glass (3)
- Sol-gel (3)
- Solid-state (3)
- TDEP (3)
- VSSA (3)
- Vickers (3)
- Crack Propagation (2)
- Crystal orientation (2)
- Crystallization (2)
- DCB (2)
- Dark-field transmission electron microscopy (DFTEM) (2)
- Depth-profiling (2)
- Deuterium (2)
- Electron beam induced modification (2)
- Electron microscopy (2)
- Environmental stress cracking (ESC) (2)
- FIB (2)
- GD-OES (2)
- Gold nanoparticles (2)
- High temperature corrosion (2)
- Imaging techniques (2)
- Inconel 686 (2)
- Iron oxide nanoparticles (2)
- Kikuchi (2)
- LTCC (2)
- Lattice parameters (2)
- Lithium Ion Batteries (2)
- Low Cycle Fatigue (2)
- Machine Learning (2)
- Metadata schema (2)
- NFDI (2)
- Ontology (2)
- Oxidation (2)
- Plattform MaterialDigital (2)
- Polymer (2)
- Ratio refinement (2)
- Reference data (2)
- Referenzdaten (2)
- Sample preparation (2)
- Sandwich (2)
- Selective laser melting (2)
- Semantic Interoperability (2)
- Semantic Web Technologies (2)
- Sintering (2)
- Syngle Crystal alloy (2)
- Ti-6Al-4V (2)
- ToF-SIMS (2)
- Water content (2)
- Water speciation (2)
- 3D imaging (1)
- 5G (1)
- AFM (1)
- AISI 304L (1)
- AM (1)
- Aggressive environement (1)
- Aggressive environment (1)
- Aging mechanisms (1)
- Al-Cu-Li alloys (1)
- Alkali ions (1)
- Aluminium (1)
- Analysis (1)
- Anhydrite (1)
- Anisotropy (1)
- Artefact (1)
- Atacama Desert (1)
- Atmospheric Plasma Spraying (1)
- Atomic packing factor (1)
- Atomization (1)
- Austenitic stainless steel (1)
- Austenitic steel (1)
- Automation (1)
- BTS (1)
- Bio Ceramics (1)
- Bioactive glass (1)
- Biofilm (1)
- Bioresorbable (1)
- Borate glasses (1)
- Brittle / ductile fracture behavior (1)
- Brittle fracture (1)
- CALPHAD (1)
- CALPHAD databases analysis (1)
- CCS (1)
- Calcium cobaltite (1)
- Carbon Fiber Reinforced Plastics (1)
- Carbon capture (1)
- Carbon dioxide (1)
- Ceramic (1)
- Chemically Complex Alloy (1)
- Chromium oxide (1)
- Co-axial monitoring (1)
- Complex concentrated alloy (CCA) (1)
- Composite (1)
- Computed Tomography (1)
- Corrosion resistance (1)
- Crack evolution (1)
- Crack healing (1)
- Crack propagation analysis (1)
- Crystal plasticity (1)
- DED-L (1)
- Dark-field transmission electron microscopy (1)
- Data Integration (1)
- Data Interoperability (1)
- Data fusion (1)
- Demonstrators (1)
- Density (1)
- Destabilization (1)
- Dielectric Spectroscopy (1)
- Diffraction Enhanced Imaging (1)
- Diffusion coefficient (1)
- Digital material representation (1)
- Digitalization (1)
- Digtial Representation (1)
- Diopside (1)
- Distributed fiber optic sensors (1)
- EDX (1)
- Electromicroscopy (1)
- Electron Backscatter Diffraction (1)
- Electronic Lab Notebook (1)
- Environmental stress cracking (1)
- FeCr- alloys (1)
- Film depositition (1)
- Focussed ion beam growth (1)
- Fracture Toughness (1)
- Fracture surface analysis (1)
- Fresnoit (1)
- Full Notch Creep Test (1)
- Full Notch Creep Test (FNCT) (1)
- Full-Notch Creep Test (FNCT) (1)
- Fused Filament Fabrication (1)
- GFRP (1)
- Glas (1)
- Glass ceramic (1)
- Glass composition (1)
- Glass fiber reinforced polymers (1)
- Glass matrix composite (1)
- Glass melt (1)
- Glass structure (1)
- Glass transformation temperature (1)
- Glass-ceramic (1)
- Gypsum (1)
- HV-Insulation (1)
- Hardness (1)
- Heat Treatment (1)
- High Cycle Fatigue (1)
- High Temperature Testing (1)
- High Voltage Insulation (1)
- High entropy alloy (1)
- High temperature (1)
- High-density polyethylene (1)
- High-entropy alloys (1)
- High-temperature corrosion (1)
- Hot stage microscopy (1)
- Hydrogen permeability (1)
- IR (1)
- In situ (1)
- In situ tensile test (1)
- In-situ tomography (1)
- In718 (1)
- Internal friction (1)
- Interoperability (1)
- Knowledge Representation (1)
- Knowledge graph and ontologies (1)
- LMD (1)
- LTCC multilayer (1)
- Laser Beam Melting (1)
- Laser Cladding (1)
- Laser Powder Bed Fusion (1)
- Laser ablation in liquid (1)
- Laser cladding (1)
- Lightweight materials (1)
- Lithium-ion batteries (1)
- Local landscape evolution (1)
- Long-term behavior (1)
- Low cycle fatigue (1)
- Manganese oxide (1)
- Material characterization (1)
- Material oxidation (1)
- Mechanical Behavior (1)
- Metal powder characterization (1)
- Metal seal (1)
- Metformin (1)
- Metrology (1)
- Micro computed tomography (1)
- Micromanipulation (1)
- Microplastics (1)
- Microstructure analysis (1)
- Modeling (1)
- NFDI-MatWerk (1)
- NMR (1)
- Nano-landscape (1)
- Nano-powder characterization (1)
- Nanomaterial screening (1)
- Optical criterion (1)
- Orientation (1)
- Orientation-dependent microstructure (1)
- Oxide Glasses (1)
- Oxidglas (1)
- PE-HD (1)
- PMD Core Ontology (1)
- PMDco (1)
- Particle size (1)
- Photocatalysis (1)
- Polyethylene, PE-HD (1)
- Polymer-Ceramic-Composite (1)
- Porosity (1)
- Precipitation (1)
- Process Monitoring (1)
- Property simulation (1)
- Reference Data (1)
- Reference Dataset (1)
- Reference material (1)
- Reference nanomaterials (1)
- Reliable characterization (1)
- Research Data Management (1)
- Residual stress (1)
- Risswachstum (1)
- Robot-assisted galss melting (1)
- Robotische Glasschmelzanlage (1)
- S-phase (1)
- SEM (1)
- SIMS (1)
- SLM (1)
- Salt melt (1)
- Scale-bridging (1)
- Scanning electron microscopy (SEM) (1)
- Scarf joint repairs (1)
- Semantic Data (1)
- Silver (1)
- Silver glass paste (1)
- Silver nanoparticle (1)
- Size and size distribution (1)
- Slurry (1)
- Small angle x-ray scattering (1)
- Sodium zinc borate glass (1)
- Sodiumborosilicate glasses (1)
- Soil sample (1)
- Starch (1)
- Starch nanoparticle (1)
- Sulfidation (1)
- Sulfiding (1)
- Surface Energy (1)
- Surface crystallization (1)
- Surface energy (1)
- Synchrotron Tomography (1)
- Synchrotron tomography (1)
- Synthetic air (1)
- TED-GC-MS (1)
- TEM (1)
- Tensile Properties (1)
- Thermal Spray (1)
- Thermodynamic analysis (1)
- Thermoelectric generator design (1)
- Thermoelectric oxides (1)
- Thermomechanics (1)
- Titanium (1)
- Titanium oxide (1)
- Transmission electron microscope (TEM) (1)
- Ultrasound (1)
- VM12 SHC (1)
- Vickers indentation (1)
- Virtual experiments (1)
- Viscosity (1)
- Wind turbine blade shells (1)
- Wind turbine blades (1)
- X-Ray Diffraction (1)
- X-ray refraction (1)
- XRD (1)
- Young´s Modulus (1)
Organisationseinheit der BAM
- 5 Werkstofftechnik (99)
- 5.1 Mikrostruktur Design und Degradation (29)
- 5.4 Multimateriale Fertigungsprozesse (21)
- 5.6 Glas (20)
- 5.2 Metallische Hochtemperaturwerkstoffe (18)
- 6 Materialchemie (15)
- 5.3 Polymere Verbundwerkstoffe (10)
- 6.1 Oberflächen- und Dünnschichtanalyse (9)
- 8 Zerstörungsfreie Prüfung (9)
- 8.5 Röntgenbildgebung (8)
Premature failure of glass under load is caused by sub-critical crack growth (SCCG) originate from microscopic flaws at the surface. While SCCG is related to the humidity of the ambient atmosphere, leading to stress corrosion phenomena at the crack tip, the detailed mechanism and the effect of different network formers are still not fully understood. For more clarity, various soda silicate glasses with a second network former were investigated by double cantilever beam technique: Na2O*Al2O3*SiO2 (NAS), Na2O*B2O3*SiO2 (NBS), Na2O*PbO*SiO2 (NPbS).
Three effects on the crack growth velocity, v, versus stress intensity, KI, curves were found out. The slope in region I, which is limited by corrosion, increases in the order NAS < NBS ≲ NPbS. The velocity range of region II reflecting the transition between corrosion effected and inert crack growth (region III), varies within one order of magnitude between the glasses. The KI region of inert crack growth strongly scatters between 0.4 and 0.9 MPam1/2. For comparison, crack growth at different humidity in commercial soda lime silicate glass (NCS) was measured.
The Ni-Cr-Mo-W alloy is characterized by the excellent high-temperature corrosion resistance, good strength and ability to work in aggressive environments. To protect the surface of the substrate 13CrMo4-5 steel against aggressive environments the Inconel 686 as clad layer was used. The corrosion process was performed in oxidizing mixture of gases like O2, COx, SOx. The second part of corrosion Experiment concerned the corrosion test of the coating in reducing atmosphere of the specified gases with ashes, which contained e.g. Na, Cl, Ca, Si, C, Fe, Al.
Sintered bioactive glass scaffolds of defined shape and porosity, e.g. made via additive manufacturing, must provide sufficient bioactivity and sinterability. As higher bioactivity is often linked to high corrosion and crystallization tendency, a certain compromise between sintering ability and bioactivity is therefore required. Groh et al. developed a fluoride-containing bioactive glass (F3), which allows fiber drawing and shows a bioactivity well comparable to that of Bioglass®45S5.
To study whether and to what extent the sinterability of F3 glass powder is controlled by particle size, coarse and fine F3 glass powders (300-310µm and 0-32µm) were prepared by crushing, sieving and milling. Sintering, degassing and phase transformation during heating were studied with heating microscopy, vacuum hot extraction (VHE), DTA, XRD, and SEM.
For the coarse glass powder, sintering proceeds slowly and is limited by surface crystallization of primary Na2CaSi2O6 crystals. Although the crystallization onset of Na2CaSi2O6 is shifted to lower temperature, full densification is attained for the fine powder. This finding indicate that certain porosity might be tuned via particle size variation. Above 900°C, intensive foaming is evident for the fine powder. VHE studies revealed that carbon species are the main foaming source.
The EC’s recommendation for a definition of nanomaterial (2011/696/EU) should allow the identification of a particulate nanomaterial based on the number-based metric criterion according to which at least 50% of the constituent particles have the smallest dimension between 1 and 100 nm. However, it has been recently demonstrated that the implementation of this definition for regulatory purposes is conditioned by the large deviations between the results obtained by different sizing methods or due to practical reasons such as high costs and time-consuming (SEM, TEM).
Within the European project NanoDefine (www.nanodefine.eu) a two-tier approach has been developed, whereby firstly a screening method is applied for the rough classification as a nano-/non-nanomaterial, and for borderline cases a confirmatory method (imaging methods or field flow fractionation) must be considered.
One of the measurement methods well suited to particulate powder is the determination of volume-specific surface area (VSSA) by means of gas adsorption as well as skeletal density. The value of 60 m2/cm3 corresponding to spherical, monodisperse particles with a diameter of 100 nm constitutes the threshold for decisioning if the material is a nano- or non-nanomaterial. The correct identification of a nanomaterial by VSSA method is accepted by the EU recommendation.
However, the application of the VSSA method is associated also by some limitations. The threshold of 60 m2/cm3 is dependent on the particle shape, so that it changes considerably with the number of nano-dimensions of the particles. For particles containing micro-pores or having a microporous coating false positive results will be produced. Furthermore, broad particle size distributions make necessary to adjust the threshold. Based on examples of commercially available ceramic powders, the applicability of the VSSA approach will be tested (in relation with SEM and TEM measurements) in order to expand the actual knowledge and to improve this good available and agglomeration tolerant method.
The EU recommendation for a definition of nanomaterial (2011/696/EU) should allow the identification of a particulate nanomaterial based on the number-based metric criterion according to which at least 50% of the constituent particles have the smallest dimension between 1 and 100 nm. Within the European Project NanoDefine (www.nanodefine.eu) a two-tier approach has been developed, whereby firstly a screening method is applied for the rough classification as a nanomaterial or non-nanomaterial, and for borderline cases a confirmatory method (imaging methods or field flow fractionation) must be considered.
One of the measurement methods well suited to particulate powder is the determination of volume-specific surface area (VSSA) by means of gas adsorption as well as skeletal density. The value of 60 m2/cm3 corresponding to spherical, monodisperse particles with a diameter of 100 nm constitutes the threshold for decisioning if the material is a nanomaterial or non-nanomaterial. The correct identification of a nanomaterial by VSSA method (positive test) is accepted by the EU recommendation.
However, the application of the VSSA method is associated also by some limitations. The threshold of 60 m2/cm3 is dependent on the particle shape. For particles containing micro-pores or having a microporous coating, false positive results will be produced.
Furthermore, broad particle size distributions – as typically for ceramic materials – as well as multi-modal size distributions make necessary to adjust the threshold.
Based on examples of commercially available ceramic powders, the applicability of the VSSA approach will be tested (in relation with SEM and TEM measurements) in order to expand the actual knowledge and
improve the method.
The reduction of harmful emissions to the environment is one of the most urgent challenges of our time. To achieve this goal, it is inevitable to shift from using fossil fuels to renewable energy sources. Within this transition, hydrogen can play a key role serving as fuel in transportation and as means for energy storage.
The storage and transport of hydrogen using austenitic stainless steels as the infrastructure, as well as the use of these grades in hydrogen containing aggressive environments, remains problematic. The degradation of the mechanical properties and the possibility of phase transformation by ingress and accumulation of hydrogen are the main drawbacks. Advanced studies of the behaviour of hydrogen in austenite is necessary to fully understand the occurring damage processes. This knowledge is crucial for the safe use of components in industry and transportation facilities of hydrogen.
A powerful tool for depicting the distribution of hydrogen in steels, with high accuracy and resolution, is time-of-flight secondary ion mass spectrometry (ToF-SIMS). We here present a comprehensive research on the hydrogen degradation processes in AISI 304L based on electrochemical charging and subsequent ToF-SIMS experiments. To obtain furthermore information about the structural composition and cracking behaviour, electron-backscattered diffraction (EBSD) and scanning electron microscopy (SEM) were performed afterwards. All the gathered data was treated employing data fusion, thus creating a thorough portrait of hydrogen diffusion and its damaging effects in AISI 304L.
Specimens were charged with deuterium instead of hydrogen. This necessity stems from the difficulty to separate between artificially charged hydrogen and traces existing in the material or adsorbed from the rest gas in the analysis chamber. Similar diffusion and permeation behaviour, as well as solubility, allow nonetheless to draw onclusions from the experiments.
The presence, fate and effects of microplastics (MP) in terrestrial systems are largely unknown. The few existing studies investigated either agricultural or industrial sites. Several techniques were used for analysis, primarly spectroscopic methods such as FTIR or Raman. Sample pretreatments like density separations are common to reduce matrix. A lack of harmonised and standardised sampling instructions for microplastic investigations in the terrestrial area was identified as particular critical, because different studies are barely comparable.
The aim of the project is to develop a proposal for a harmonized procedure for sampling, sample preparation and the detection of microplastics in terrestrial matrices for total content determination. By detecting specific degradation products the thermal extraction desorption gas chromatography mass spectrometry (TED-GC-MS) allows a direct determination of mass content of MP in environmental samples.
Influence of deposition hatch length on residual stress in selective laser melted Inconel 718
(2018)
The present study aims to evaluate the bulk residual stresses in SLM parts by using neutron diffraction measurements performed at E3 line -BER II neutron reactor- of Helmholtz-Zentrum für Materialien und Energie (HZB) Berlin. Together with microstructure characterization and distortion measurements, it is possible to describe the stress state throughout the whole sample. The sample was measured in as-build condition (on a build plate) and after releasing from the build plate. The used material is the nickel based superalloy 718. This alloy is widely used in aerospace and chemical industries due to its superior corrosion and heat resistant properties.
Obtained results indicated different residual stress states for each of the transversal, longitudinal and normal component. The normal and transversal component exhibits a rather compressive behavior while the longitudinal was tensile in the center part of the sample and became compressive towards the tip. As expected, the absolute values of all stress components decreased after releasing the sample from the building plate. A surface scan utilizing a coordinate-measuring machine (CMM) allowed us to present top surface distortion before and after releasing. The top surface showed a distortion around ±80µm after releasing. Microstructure evolution in the scanning-building cross-section is largely dominated by columnar grains. In addition, many small random orientated grains are prominent in the regions of a laser overlap during SLM.
In summary, for the sample of superalloy 718 manufactured by SLM, a small distortion occurred when removing the sample from the build plate whereby the residual stress state decreases. Moreover, the observed columnar grains in the building direction could give a reason for the lowest stress values in that normal direction. However, the most important parameter controlling the residual stresses is the temperature gradient. Hence, future investigations are planned for a different scan strategy to distribute the laser impact in a more homogenous manner.
As the well-known damage mechanisms slow crack growth (SCG) and environmental stress cracking (ESC) are the major causes for possible failure of polyolefin-based materials, especially for PE-HD, they are highly relevant and need to be considered thoroughly. Furthermore, due to slight but perceptible differences in damaging effect, a differentiation between SCG and ESC is expedient. SCG appears in “inert” or “neutral” media without a decisive influence of the surrounding medium whereas ESC occurs in “active” media, which influence the failure behavior and time to failure crucially.
To characterize the inherent resistance of the material against those damage mechanisms, the well-established Full-Notch Creep Test (FNCT) is used. In this study, the FNCT – usually applied according to ISO 16770 [3] using a few universal model liquid media and mainly for pipe materials – is extended by investigations with appropriate parameters of selected relevant PE-HD container materials also in real media, such as the topical fuels diesel and biodiesel. The investigations were performed using a novel FNCT-device with 12 individual sub-stations, each equipped with individual electronic stress and temperature control and continuous online monitoring of the specimen elongation.
Especially, mechanical stress and temperature were varied systematically during FNCT and time to failure values, time-dependent elongation data as well as detailed fracture surface analysis by laser scanning microscopy (LSM) were combined for the first time (Fig. 1). Particularly, the fracture surface analysis provides a sound basis to characterize failure behavior, mainly regarding the balance between brittle crack propagation and ductile deformation. Therefore, fracture surface analysis is an essential tool for a decent assessment of SCG and ESC by FNCT measurements.