5 Werkstofftechnik
Filtern
Erscheinungsjahr
- 2018 (1) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (1) (entfernen)
Sprache
- Englisch (1)
Referierte Publikation
- nein (1)
Schlagworte
- Adiabatic calorimeter (1) (entfernen)
Organisationseinheit der BAM
- 5 Werkstofftechnik (1) (entfernen)
The commercial usage of latent thermal energy storages primarily depends on the development of a suitable phase change material (PCM). For industrial high temperature applications above 400 °C multicomponent chloride eutectics are promising and therefore discussed seriously. The profound thermodynamic investigation of such eutectics requires a much greater amount of specimen material than conventional calorimeter can handle. Therefore, a special adiabatic calorimeter was developed and designed. With a specimen mass of > 100 g the typical thermodynamic measurements with a commercial calorimeter can be extended by cycle stability measurements, which are often decisive for practical application of PCM. Furthermore, by implementing corrosion specimens inside the calorimeter high temperature corrosion experiments according to ISO 21608 can be performed inside the calorimeter. Adiabatic measuring conditions can be provided by using two separate heating systems. Therefore, the outer “protective system” follows the temperature curve of the inner “measuring system” minimizing the temperature difference between the heating systems and simultaneously preventing heat losses from the measuring systems.