5 Werkstofftechnik
Filtern
Erscheinungsjahr
- 2019 (55) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (55) (entfernen)
Sprache
- Englisch (55)
Schlagworte
- Corrosion (7)
- Carbon steel (3)
- Crystallization (3)
- 3D printing (2)
- Additive Manufacturing (2)
- Additive manufacturing (2)
- Bioactive glass (2)
- Condensate (2)
- Corrosion Fatigue (2)
- Degradation (2)
- Ductile iron (2)
- Fatigue (2)
- High Alloyed Steel (2)
- Impurities (2)
- NMR spectroscopy (2)
- Niobium alloying (2)
- Oxidation (2)
- Pitting (2)
- AISI 304L (1)
- Abrasion (1)
- Alkali-activated materials (1)
- Alumina (1)
- Aluminosilicate glasses (1)
- Aquifer (1)
- Artificial weathering (1)
- Bioceramics (1)
- Biodiesel (1)
- Biogeochemical cycling (1)
- Biomineralisation (1)
- Biopolymer (1)
- Bubble formation (1)
- C. lap-shear (1)
- CCS (1)
- CCUS (1)
- CFRP (1)
- CO2 (1)
- CO2 separation membranes (1)
- Calcination (1)
- Calcium cobaltite (1)
- Carbidic austempered ductile iron (1)
- Carbon capture (1)
- Carbon capture, utilization and storage technology (1)
- Carbon fibres (1)
- Carbon storage (1)
- Cavitation (1)
- Cellulose (1)
- Ceramic (1)
- Ceramics (1)
- Chalcogenides (1)
- Characterisation (1)
- Coefficient of thermal expansion (1)
- Contact angle (1)
- Contact fatigue (1)
- Copper vacancies (1)
- Corrosion pits (1)
- Crack arrest (1)
- Crack propagation (1)
- Crosslinking (1)
- Crystal Texture (1)
- Cyclic softening (1)
- D. aging (1)
- D. creep D. viscoelasticity (1)
- Defects (1)
- Deuterium (1)
- Dielectric breakdown (1)
- Diesel (1)
- Diesel Fuel (1)
- Distributed fiber optic sensing (1)
- EBSD (1)
- Early oxidation (1)
- Early sulfidation (1)
- Elastic constants (1)
- Electrochemical characterisation (1)
- Electrochemical deposition (1)
- Electrochemical impedance spectroscopy (1)
- Electron energy (1)
- Electron microscopy (1)
- Endurance Limit (1)
- Energy distribution (1)
- Environment (1)
- Environmentally assisted cracking (1)
- Exposed metal sites (1)
- FSDC (1)
- Fabrication (1)
- Facilitated activation (1)
- Fatigue Testing (1)
- Fatigue crack propagation stages (1)
- Ferritic steels (1)
- Ferritic–martensitic steel (1)
- Finite element analysis (1)
- Four-point bending test (1)
- Fracture (1)
- Fracture mechanics (1)
- Freeze casting (1)
- Friction Stir Welding (1)
- Frozen state photopolymerization (1)
- GFRP (1)
- Geothermal (1)
- Glass (1)
- Glass-ceramic (1)
- Gold (1)
- Grain boundary (1)
- Heat treatment (1)
- Hierarchical porosities (1)
- High pressure (1)
- High temperature corrosion (1)
- High-temperature oxidation (1)
- High-temperature properties (1)
- High-voltage testing (1)
- Hydrogel (1)
- Hydrogen (1)
- Hydrogen diffusivity (1)
- Hygrothermal (1)
- Impact damage (1)
- In-situ Process Monitoring (1)
- Inclusion cluster (1)
- Inclusion size (1)
- Inconel 625 (1)
- Incremental lifetime models (1)
- Infrared nano AFM (1)
- Infrared spectroscopy (1)
- Intermodulation AFM (1)
- Internal Surfaces (1)
- Internal oxidation (1)
- Interphase (1)
- Ionic porosity (1)
- Iron meteorite (1)
- Kikuchi pattern (1)
- LSD print (1)
- Laser beam melting (1)
- Laser-induced slip casting (1)
- Layerwise slurry deposition (1)
- Long-term storage (1)
- Low cycle fatigue (1)
- MOF-74 (1)
- Magmatic and hydrothermal processes (1)
- Martensite (1)
- Mass transport (1)
- Material degradation (1)
- Micro-shrinkages (1)
- Microhardness (1)
- Mis-match (1)
- Mixed Ca-K-Na phosphates (1)
- Mixed-linkers (1)
- Moisture (1)
- Multiple cracks (1)
- Na and K rhenanites (1)
- Nanocomposites (1)
- Natural (1)
- Neutron diffraction (1)
- Nitride (1)
- Non-destructive Materials (1)
- Non-metallic inclusions (1)
- Orientation relationship (1)
- Oxidation protection (1)
- P92 (1)
- PE-HD Sorption (1)
- Parabolic flight (1)
- Permeability (1)
- Phase diagram (1)
- Phase transformations (1)
- Phase-field (1)
- Phosphate (1)
- Pitting corrosion (1)
- Plastic deformation (1)
- Platinum-group-metals (1)
- Polyaniline (1)
- Polymer (1)
- Polyurethane (1)
- Pores (1)
- Preceramic polymer (1)
- Pressure-assisted sintering (1)
- Process development (1)
- Processing window (1)
- Pultruded fiber rods (1)
- Relaxation fatigue (1)
- Resonance testing (1)
- Roughness (1)
- SDC (1)
- STEM (1)
- Safety (1)
- Samarium doped ceria (1)
- Sandwich (1)
- Scaffolds (1)
- Scavenging effect of iron (1)
- Scratches (1)
- Silicoborate glasses (1)
- Silicon Carbide (1)
- Simulation (1)
- Sintering (1)
- Slip-rolling (1)
- Soda-lime-silica (1)
- Soda-lime-silica glass (1)
- Sodium ion batteries (1)
- Sol-gel coating (1)
- Sorption (1)
- Spar cap design (1)
- Standardisation (1)
- Statistics (1)
- Steel (1)
- Stress intensity factor (1)
- Stress-strain behavior (1)
- Structural composites (1)
- Structural defects (1)
- Structural health monitoring (1)
- Subcritical crack growth (1)
- Sulfidation (1)
- Superconducting magnet (1)
- Surface (1)
- Surface treatments (1)
- Swept wavelength interferometry (1)
- Synthesis (1)
- Thermoelectric properties (1)
- Thiol-ene click chemistry (1)
- ToF-SIMS (1)
- Tungsten-Rhenium (1)
- Utilization, and storage (CCUS) technology (1)
- Vickers indentation (1)
- Viscoelastic model (1)
- Viscous sintering (1)
- WAXS (1)
- Water content (1)
- Water speciation (1)
- Wetting (1)
- X-ray absorption spectroscopy (1)
- X-ray refraction (1)
- Young´s modulus (1)
- ZnO (1)
- arbidic austempered ductile iron (1)
- bioactive (1)
- biomaterials (1)
- bone (1)
- high pressure (1)
- infrared spectroscopy (1)
- phosphate glasses (1)
- water speciation (1)
- µ-gravity (1)
Organisationseinheit der BAM
- 5 Werkstofftechnik (55)
- 5.1 Mikrostruktur Design und Degradation (22)
- 5.4 Multimateriale Fertigungsprozesse (12)
- 5.6 Glas (11)
- 7 Bauwerkssicherheit (9)
- 9 Komponentensicherheit (8)
- 5.3 Polymere Verbundwerkstoffe (7)
- 5.2 Metallische Hochtemperaturwerkstoffe (5)
- 6 Materialchemie (5)
- 5.0 Abteilungsleitung und andere (4)
The use of high niobium alloyed cast iron alloys is a relatively new approach in which the niobium addition intends to improve the properties of the material by the precipitation of hard niobium carbides during solidification. Steels can be replaced by ductile cast iron in some rolling applications, such as gears and cams, in order to reduce material costs. The aim of this work is to evaluate ductile iron alloyed with 1 weight percent (wt.%) niobium for the as cast specimens and with 1.8 wt.% and 2.4 wt.% niobium for the austempered specimens under lubricated slip-rolling tests using mixed/boundary conditions in an Amsler-type machine. Austempered ductile iron (ADI) alloyed with 1 wt.% chromium, or Carbidic ADI, was tested for comparison. For the as cast conditions, the niobium addition resulted in an increase of wear resistance owing to the low contact pressure of these tests. However, for the austempered specimens, the best performance was found for unalloyed ADI. The main factor acting in the initiation and propagation of cracks in ductile iron is the presence of the graphite nodules. The coarse carbides also contributed to the initiation of cracks and spalling of the material.
Carbidic Austempered Ductile Iron (CADI) microstructures containing eutectic carbides can be produced by the addition of carbide stabilizing elements, such as chromium. Carbides formed from the addition of Cr are eutectic of M3C type. The presence of such hard phases can enhance the abrasion wear resistance of ductile iron. A new CADI can be produced by the addition of Nb. Niobium carbide particles are formed in the beginning of solidification and remain stable once they are insoluble in solid iron matrix. The dry sand abrasive wear resistance of ductile irons alloyed with 1.0, 1.8, and 2.4 wt% Nb were tested in both “as-cast” and “heat treated” conditions using standard ASTM G65. Results were compared to abrasive wear data obtained on ductile iron alloyed with 1 wt% Cr, CADI (1 wt% Cr), and the basic composition of iron without carbide stabilizing elements. In the “ascast” condition, the addition of Nb did not lead to a reduction in wear, while CADI with Nb is a promising substitute for CADI with Cr addition, because both materials showed very similar values of abrasion resistance.
Micro-ploughing and micro-cutting mechanisms were observed on the worn surfaces of ductile irons. Abrasive wear resistance of these alloys was correlated with the volume fraction of carbides.
Due to the stochastic nature of crack nucleation by Vickers indentation, a statistical analysis of propagation rates of 185 radial cracks was performed. Crack growth was observed directly using a video camera with high Image acquisition rate. It is found that propagation rates are controlled by the environmental reactions at the crack-tip shortly after their initiation (< 1 s). Calibration of the stress intensity KI showed that the residual stress factor χ and the exponent n of the equation KI==χPc−n (with P==load and c==crack length) are broadly distributed among the 185 analyzed cracks, ranging from 10−16 to 104 and from 0.1 to 5, respectively. For the most frequent crack, the equation KI==0.052Pc−1.47 holds. The results show that correlations of indentation-induced crack length to stress intensity necessitate the use of statistical significant data that are calibrated by the environmental reactions at the crack-tip.
Hydrogen gas diffusivity of fourteen glasses of the Na2O-Al2O3-SiO2 system are studied along the joins quartzalbite-jadeite-nepheline (Qz-Ab-Jd-Np, fully polymerized) and albite-sodium disilicate (Ab-Ds, depolymerized).
Density measurements show that ionic porosity decreases from 54.4% (Qz) to 51.5% (Np) and from 52.4% (Ab) to 50.2% (Ds). Hydrogen diffusivity D follows similar trends but at another scale. D at 523 K decreases from 4×10−12 to 3×10−14m2 s−1 (Qz-Np) and from 4×10−13 to 3×10−15m2 s−1 (Ab-Ds). Charge compensating Na+ acting as a filling agent in fully polymerized network structures leads to up to one order of Magnitude higher diffusivities as depolymerized glass structures of the same SiO2 content where Na+ takes the role of a
modifier ion. Temperature dependence of the diffusivity indicates that both the activation energy involved with the moving H2 molecule as well as the accessible volume in the structure contribute to this compositional trend.
Coupons of X5CrNiCuNb16-4 with different surface roughness that may be utilized as injection pipe with 16% Chromium and 0.05% Carbon (1.4542, AISI 630) were exposed for 3000 h to CO2-saturated saline aquifer water simulating the conditions in the Northern German Basin at ambient pressure and 60 °C. Additionally, corrosion fatigue experiments (ambient pressure, technically clean CO2, saline aquifer water of Stuttgart Aquifer) were performed using specimen of X46Cr13 (1.4043, AISI 420C) with regard to the influence of the roughness of technical surfaces on the number of cycles to failure at different stress amplitudes. Specimen of Duplex stainless steel X2CrNiMoN22-3-2 (1.4462) for corrosion fatigue experiments were provided with technical surfaces after machining as well as polished surfaces. Results were obtained at load amplitudes ranging from 175 MPa to 325 MPa in the geothermal brine of the Northern German Basin at 98 °C. The main precipitation phases on the surface as well as within pits reveal carbonates or hydroxides such as siderite (FeCO3) and ferrous hydroxide goethite (FeOOH) independent of the original surface roughness. Corrosion rates for polished and technical surfaces were below 0.005 mm/year compared to corrosion rates of 0.035 mm/year after shot peening. Specimen with technical surfaces tested at high stress amplitudes (>275 MPa) lasted longer (cycles to failure: P50% at Sa 300 MPa=5x105) than specimen with polished surfaces (cycles to failure: P50% at Sa 300 MPa=1.5x105). This behavior is emphasized by the slope coefficient (technical surfaces k = 19.006, polished surfaces k=8.78) meaning earlier failure for polished at high stress amplitude Sa. Although rather low scatter ranges (technical surface: TN=1:1.35, polished surface: TN=1.1.95) indicate no change in failure mechanism it may be assumed that at low stress pitting is the initiating crack growth process whereas at high stress amplitudes the formation of micro cracks is reason for crack propagation and failure.
During capture and storage technology (CCS) as well as in geothermal energy production Steels need to withstand the corrosive environment such as: heat, pressure, salinity of the aquifer and CO2-partial pressure. 1.4542 shows unusual corrosion phenomena, but is still sufficiently resistant in corrosive environments. To better understand its behaviour differently heat treated coupons of 1.4542 and for comparison X20Cr13 and X46Cr13 were kept in the artificial brine of the Northern German Basin at T=60 °C. Ambient pressure as well as p=100 bar for 700 h - 8000 h in water saturated supercritical CO2 and CO2-saturated synthetic aquifer Environment was applied. Fatigue tests were performed via push-pull tests with a series of 30 specimens from 150 MPa to 500 MPa (sinusoidal dynamic test loads, R=-1; resonant frequency ~ 30 Hz). FeCO3 and FeOOH are corrosion products also after dynamic corrosion tests. Martensitic microstructure offers good corrosion resistance in geothermal environment. The S-N-curve showing no typical fatigue strength and very steep slopes of possible fatigue strength for finite life. Possible influencing artefacts, such as Al-inclusions could not be correlated to early rupture despite specimens containing inclusions at the fracture surface and cross section reached lower number of cycles. Applied potential proofed to enhance fatigue life tremendously.
Corrosion fatigue specimen with different surfaces (technical surfaces after machining and polished surfaces) of high alloyed martensitic stainless steel X46Cr13 (1.4043) and duplex stai nless steel X2CrNiMoN22 3 2 (1.4462) were compared at load amplitudes from 175 MPa to 325 MPa in the geothermal brine of the N orthern German Basin at 98 °C. Surface corrosion layers and pits reveal carbonate corrosion products on the surface such as FeCO 3 and FeOOH as the main precipitation phases with no dependence on the original surface roughness . At high stress amplitudes above 275 MPa technical surfaces (P50% at σa 300 MPa=5 × 10 5 ) resulted in more cycles to failure than polished (P50% at σa 300 MPa=1.5 × 10 5 ). The greater slope coefficient for technical surfaces k = 19.006 compared to polished surfaces k =8.78 demonstrate s earlier failure at given stress amplitude σa .
Roaldite – Fe4N – has been identified in the São Julião de Moreira iron meteorite using electron backscatter diffraction (EBSD) and simultaneously acquired energy-dispersive x-ray spectroscopy (EDS). Mean-periodic-number images derived from raw EBSD patterns confirm this phase by an even higher spatial resolution compared to EDS.
Roaldite appears in the form of systematically and repetitively aligned plates. Despite the locally heavy plastic deformation, it is shown that the origin of the oriented precipitation of roaldite is linked to the orientation of the kamacite matrix. Roaldite can be considered to be precipitated from kamacite using an inverse Kurdjumov-Sachs (K-S) or Nishiyama-Wassermann (N-W) orientation relationship. A more accurate discrimination is impossible due to the accumulated shock deformation, which blurs the local reference orientation of kamacite. The habit plane of roaldite is found to be {112}R, which is most likely parallel to {120}K of kamacite. Some of the roaldite plates contain two orientation variants which repeatedly alternate. Their misorientation angle is about 12°.
Spherical mesoporous bioactive glasses in the silicon dioxide (SiO2)-phosphorus pentoxide (P2O5)–calcium oxide (CaO) system with a high specific surface area of up to 300m2/g and a medium pore radius of 4 nm were synthesized by using a simple one-pot surfactant-assisted sol–gel synthesis method followed by calcination at 500–700°C. The authors were able to control the particle properties by varying synthesis parameters to achieve microscale powders with spherical morphology and a particle size of around 5–10 mm by employing one structure-directing agent. Due to a high Calcium oxide content of 33·6mol% and a phosphorus pentoxide content of 4·0mol%, the powder showed very good bioactivity up to 7 d of immersion in simulated Body fluid. The resulting microspheres are promising materials for a variety of life science applications, as further processing – for example, granulation – is unnecessary. Microspheres can be applied as materials for powder-based additive manufacturing or in stable suspensions for drug release, in bone cements or fillers.
An effective method for evaluating the fatigue strength of thick unidirectional composite laminates of wing spar caps has been presented here. A typical width-tapered bending specimen has been developed for a four-point loading set up. Static and fatigue loading was performed at a load ratio R = -1. The complex stress state has been investigated numerically by finite element analysis. Finally, the concept is proven experimentally on specimens made of pultruded fibre rods.
The fatigue behavior of the continuously tapered width by water Jet cutting has been compared to discrete tapering via rod-drop. The new method enables a screening of material fatigue behavior caused by normal and shear loading.