5 Werkstofftechnik
Filtern
Dokumenttyp
- Posterpräsentation (94) (entfernen)
Sprache
- Englisch (94) (entfernen)
Referierte Publikation
- nein (94)
Schlagworte
- Glass (6)
- Additive manufacturing (5)
- Degradation (5)
- Microstructure (5)
- Additive Manufacturing (4)
- Coarsening (4)
- Corrosion (4)
- Crack growth (4)
- Creep (4)
- FAIR (4)
- Transmission electron microscopy (4)
- 316L (3)
- Ab-initio (3)
- Alloy 2618A (3)
- Fatigue (3)
- Hydrogen (3)
- NTE (3)
- Nanoparticles (3)
- Soda-lime silicate glass (3)
- Sol-gel (3)
- Solid-state (3)
- TDEP (3)
- VSSA (3)
- Vickers (3)
- Crack Propagation (2)
- Crystal orientation (2)
- Crystallization (2)
- DCB (2)
- Dark-field transmission electron microscopy (DFTEM) (2)
- Depth-profiling (2)
- Deuterium (2)
- Electron beam induced modification (2)
- Electron microscopy (2)
- Environmental stress cracking (ESC) (2)
- FIB (2)
- GD-OES (2)
- Gold nanoparticles (2)
- High temperature corrosion (2)
- Imaging techniques (2)
- Inconel 686 (2)
- Iron oxide nanoparticles (2)
- LTCC (2)
- Lithium Ion Batteries (2)
- Low Cycle Fatigue (2)
- Machine Learning (2)
- Metadata schema (2)
- NFDI (2)
- Ontology (2)
- Oxidation (2)
- Polymer (2)
- Reference data (2)
- Referenzdaten (2)
- Sample preparation (2)
- Sandwich (2)
- Selective laser melting (2)
- Semantic Web Technologies (2)
- Sintering (2)
- Syngle Crystal alloy (2)
- Ti-6Al-4V (2)
- ToF-SIMS (2)
- Water content (2)
- Water speciation (2)
- 3D imaging (1)
- 5G (1)
- AFM (1)
- AISI 304L (1)
- AM (1)
- Aggressive environement (1)
- Aggressive environment (1)
- Aging mechanisms (1)
- Al-Cu-Li alloys (1)
- Alkali ions (1)
- Aluminium (1)
- Analysis (1)
- Anhydrite (1)
- Anisotropy (1)
- Artefact (1)
- Atacama Desert (1)
- Atmospheric Plasma Spraying (1)
- Atomic packing factor (1)
- Atomization (1)
- Austenitic stainless steel (1)
- Austenitic steel (1)
- Automation (1)
- BTS (1)
- Bio Ceramics (1)
- Bioactive glass (1)
- Biofilm (1)
- Bioresorbable (1)
- Borate glasses (1)
- Brittle / ductile fracture behavior (1)
- Brittle fracture (1)
- CALPHAD (1)
- CALPHAD databases analysis (1)
- CCS (1)
- Calcium cobaltite (1)
- Carbon Fiber Reinforced Plastics (1)
- Carbon capture (1)
- Carbon dioxide (1)
- Ceramic (1)
- Chemically Complex Alloy (1)
- Chromium oxide (1)
- Co-axial monitoring (1)
- Complex concentrated alloy (CCA) (1)
- Composite (1)
- Computed Tomography (1)
- Corrosion resistance (1)
- Crack evolution (1)
- Crack healing (1)
- Crack propagation analysis (1)
- Crystal plasticity (1)
- DED-L (1)
- Dark-field transmission electron microscopy (1)
- Data Interoperability (1)
- Data fusion (1)
- Density (1)
- Destabilization (1)
- Dielectric Spectroscopy (1)
- Diffraction Enhanced Imaging (1)
- Diffusion coefficient (1)
- Digital material representation (1)
- Digitalization (1)
- Diopside (1)
- Distributed fiber optic sensors (1)
- EBSD (1)
- EDX (1)
- Electromicroscopy (1)
- Electron Backscatter Diffraction (1)
- Environmental stress cracking (1)
- FeCr- alloys (1)
- Film depositition (1)
- Focussed ion beam growth (1)
- Fracture Toughness (1)
- Fracture surface analysis (1)
- Fresnoit (1)
- Full Notch Creep Test (1)
- Full Notch Creep Test (FNCT) (1)
- Full-Notch Creep Test (FNCT) (1)
- GFRP (1)
- Glas (1)
- Glass ceramic (1)
- Glass composition (1)
- Glass fiber reinforced polymers (1)
- Glass matrix composite (1)
- Glass melt (1)
- Glass structure (1)
- Glass transformation temperature (1)
- Glass-ceramic (1)
- Gypsum (1)
- HV-Insulation (1)
- Hardness (1)
- Heat Treatment (1)
- High Cycle Fatigue (1)
- High Temperature Testing (1)
- High Voltage Insulation (1)
- High entropy alloy (1)
- High temperature (1)
- High-density polyethylene (1)
- High-entropy alloys (1)
- High-temperature corrosion (1)
- Hot stage microscopy (1)
- Hydrogen permeability (1)
- IR (1)
- In situ (1)
- In situ tensile test (1)
- In-situ tomography (1)
- In718 (1)
- Internal friction (1)
- Knowledge Representation (1)
- LMD (1)
- LTCC multilayer (1)
- Laser Beam Melting (1)
- Laser Cladding (1)
- Laser Powder Bed Fusion (1)
- Laser ablation in liquid (1)
- Laser cladding (1)
- Lightweight materials (1)
- Lithium-ion batteries (1)
- Local landscape evolution (1)
- Long-term behavior (1)
- Low cycle fatigue (1)
- Manganese oxide (1)
- Material characterization (1)
- Material oxidation (1)
- Mechanical Behavior (1)
- Metal powder characterization (1)
- Metal seal (1)
- Metformin (1)
- Metrology (1)
- Micro computed tomography (1)
- Micromanipulation (1)
- Microplastics (1)
- Microstructure analysis (1)
- Modeling (1)
- NFDI-MatWerk (1)
- NMR (1)
- Nano-landscape (1)
- Nano-powder characterization (1)
- Nanomaterial screening (1)
- Optical criterion (1)
- Orientation (1)
- Orientation-dependent microstructure (1)
- Oxide Glasses (1)
- Oxidglas (1)
- PE-HD (1)
- PMD Core Ontology (1)
- PMDco (1)
- Particle size (1)
- Photocatalysis (1)
- Plattform MaterialDigital (1)
- Polyethylene, PE-HD (1)
- Polymer-Ceramic-Composite (1)
- Porosity (1)
- Precipitation (1)
- Process Monitoring (1)
- Property simulation (1)
- Reference Data (1)
- Reference Dataset (1)
- Reference material (1)
- Reference nanomaterials (1)
- Reliable characterization (1)
- Research Data Management (1)
- Residual stress (1)
- Risswachstum (1)
- Robot-assisted galss melting (1)
- Robotische Glasschmelzanlage (1)
- S-phase (1)
- SEM (1)
- SIMS (1)
- SLM (1)
- Salt melt (1)
- Scale-bridging (1)
- Scanning electron microscopy (SEM) (1)
- Scarf joint repairs (1)
- Semantic Interoperability (1)
- Silver (1)
- Silver glass paste (1)
- Silver nanoparticle (1)
- Size and size distribution (1)
- Slurry (1)
- Small angle x-ray scattering (1)
- Sodium zinc borate glass (1)
- Sodiumborosilicate glasses (1)
- Soil sample (1)
- Starch (1)
- Starch nanoparticle (1)
- Sulfidation (1)
- Sulfiding (1)
- Surface Energy (1)
- Surface crystallization (1)
- Surface energy (1)
- Synchrotron Tomography (1)
- Synchrotron tomography (1)
- Synthetic air (1)
- TED-GC-MS (1)
- TEM (1)
- Tensile Properties (1)
- Thermal Spray (1)
- Thermodynamic analysis (1)
- Thermoelectric generator design (1)
- Thermoelectric oxides (1)
- Thermomechanics (1)
- Titanium (1)
- Titanium oxide (1)
- Transmission electron microscope (TEM) (1)
- Ultrasound (1)
- VM12 SHC (1)
- Vickers indentation (1)
- Virtual experiments (1)
- Viscosity (1)
- Wind turbine blade shells (1)
- Wind turbine blades (1)
- X-Ray Diffraction (1)
- X-ray refraction (1)
- XRD (1)
- Young´s Modulus (1)
Organisationseinheit der BAM
- 5 Werkstofftechnik (94)
- 5.1 Mikrostruktur Design und Degradation (27)
- 5.4 Multimateriale Fertigungsprozesse (20)
- 5.6 Glas (20)
- 5.2 Metallische Hochtemperaturwerkstoffe (16)
- 6 Materialchemie (15)
- 5.3 Polymere Verbundwerkstoffe (10)
- 6.1 Oberflächen- und Dünnschichtanalyse (9)
- 8 Zerstörungsfreie Prüfung (9)
- 8.5 Röntgenbildgebung (8)
The presence of water in the surrounding atmosphere of a propagating crack has a major influence on the subcritical crack growth. While these external phenomena are well understood, there is still a lack of knowledge on the influence of structurally bound water on crack propagation. Thus, our recent study aims on the analysis of crack propagation in water bearing soda-lime silicate glasses with up to 8 wt.% water. The samples were synthesized in an internally heated pressure vessel at 0.5 GPa. Since this preparation route limits the sample sizes, standard test geometries allowing for the determination of stress intensity factors, such as double cantilever beam, are not feasible. Thus, radial cracks in the hydrous glasses were initiated by Vickers indentation and crack growth was simultaneously captured with a camera system. An automated image analysis algorithm was used for the analysis of the crack length of each single video frame. To minimize influences by atmospheric water, all experiments were conducted in a glovebox purged with dry N2. About 150 cracks per glass composition were analyzed to provide statistical significance of the Vickers-induced SCCG. The results show that structurally bound water has a major influence on SCCG by means of crack lengths, growth rates and time of crack initiation.
Glass strength and fatigue is limited by surface cracks. As subcritical crack growth (SCCG) is governed by ambient humidity, stress corrosion at the crack tip is widely accepted to be the underlying mechanism. However, as water is known to have decisive effect on glass properties and can rapidly enter the crack tip near glass region, SCCG could be affected by such water related phenomena. We tried to mimic these effects studying water dissolution and speciation, mechanical properties, and SCCG in water-bearing glasses. For this purpose, glasses up to 8 wt% water have been prepared by means of high-pressure melting of glass powder - water mixtures.
As part of this effort, SCCG in dry and hydrous commercial micros¬cope slide glass (CW = 6 wt%) was studied in double cantilever beam (DCB) geometry and sub-Tg relaxation was measured by Dynamic Mechanical Analysis (DMA).
For SCCG in ambient air (24% r.h.), SCCG was promoted by the presence of 6wt% bulk water with respect to the dry glass. On the other hand, stress intensity values, KI, required to cause slow crack growth (v < 10-6 ms-1) resemble literature findings for float glass of similar composition in liquid water, which might represent the maximum possible promoting effect of ambient water on SCCG.
For SCCG in vacuum (10-3 mbar), dissolved bulk water causes even more pronounced effects. Most strikingly, it strongly decreases the slope of the log v(KI)-curve, which is a measure of dissipated energy during fracture. A strong increase of sub-Tg relaxation with increasing water content was confirmed by DMA. As a consequence, slow crack growth occurs at KI values as measured in the dry glass whereas fast crack growth occurs at much larger KI than that of the dry glass. Kinks and shoulders shown by the inert log v(KI)-curve indicate that bulk water does not simply affect bulk mechanical properties.
Premature failure of glass under load is caused by sub-critical crack growth (SCCG) originate from microscopic flaws at the surface. While SCCG is related to the humidity of the ambient atmosphere, leading to stress corrosion phenomena at the crack tip, the detailed mechanism and the effect of different network formers are still not fully understood. For more clarity, various soda silicate glasses with a second network former were investigated by double cantilever beam technique: Na2O*Al2O3*SiO2 (NAS), Na2O*B2O3*SiO2 (NBS), Na2O*PbO*SiO2 (NPbS).
Three effects on the crack growth velocity, v, versus stress intensity, KI, curves were found out. The slope in region I, which is limited by corrosion, increases in the order NAS < NBS ≲ NPbS. The velocity range of region II reflecting the transition between corrosion effected and inert crack growth (region III), varies within one order of magnitude between the glasses. The KI region of inert crack growth strongly scatters between 0.4 and 0.9 MPam1/2. For comparison, crack growth at different humidity in commercial soda lime silicate glass (NCS) was measured.
Statistical analysis of Vickers induced subcritical crack growth in soda-lime silicate glasses
(2018)
Studies on Vickers induced subcritical crack growth are controversially discussed since the stresses that drive the crack growth are distributed three dimensionally within the material and cannot be retraced by available methods. Hence, empirical approaches are used to calculate mechanical material parameters such as the stress intensity factor KI. However, the results of these approaches show large deviations from those measured by standardized techniques such as double cantilever beam (DCB) or double cleavage drilled compression (DCDC). Yet, small specimen sizes and low specimen quantities can prevent the execution of DCB and DCDC measurements. Here we present an approach that is based on a statistical analysis of Vickers induced radial cracks. For this purpose more than 150 single radial cracks were analyzed. The cracks were generated in a commercial soda-lime silicate glass. The experiments were performed in a glovebox purged with dry nitrogen gas to minimize the influence of atmospheric water on crack growth. The temporally resolved evolution of the radial cracks was monitored in-situ using an inverted microscope equipped with a camera system directly below the Vickers indenter. An automated image analysis software was used to determine the crack length over time. The data show that the crack propagation and thereby the crack velocities are not uniformly but statistically distributed. These findings allow, using the statistical mean value of the distributions in combination with DCB data, a precise formulation of KI for each measured crack length.
Among the very few techniques to localize hydrogen (H) at the microscale in steels, Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was proven to be a reliable tool. The necessity to detect hydrogen stems from its deleterious effects in metals, that are often used as structural components and to obtain better understanding of the underlying metallurgical mechanisms of hydrogen embrittlement (HE) which are still unclear.
Austenitic stainless steels are nowadays commonly used in a wide variety of application, from hydrogen transport and storage facilities to petrochemical and offshore applications where they are exposed to aggressive environments and therefore prone to HE. One of the greater risks in the austenitic class is the embrittlement of the material due to the instability of the γ austenite and its transformation into a brittle α martensitic phase. This transformation takes place due to the local stresses that are induced by the uptake of hydrogen during service. Nonetheless, it was shown that this transformation can occur as an artefact during SIMS analysis itself where Cs-sputtering is necessary not only to remove surface contaminations but mainly to enhance H/D secondary ion yield.
In the following contribution we show the influence of different sputtering conditions on AISI 304L austenitic stainless steel in order to distinguish the artefact from the hydrogen induced transformation. The material was charged electrochemically in a deuterium based electrolyte. Deuterium (D) must be in these experiments as a replacement for hydrogen which cannot be used because adsorbed hydrogen superimposes hydrogen originating from charging the sample in the SIMS images. ToF-SIMS analyses were conducted by ToF SIMS IV (IONTOF GmbH, Münster, Germany). The experiments were carried out on deuterium charged and non-charged samples. The structural characterization was carried out by SEM and EBSD examinations before and after charging, both with a Leo Gemeni 1530VP field-emission scanning electron microscope and a Zeiss Supra 40 instrument (Carl Zeiss Microscopy GmbH, Oberkochen, Germany). The results showed that the use of 1keV Cs+ beam induces stacking faults while higher sputter beam energies results in γ→α transformation.
High conductive silver metallization pastes are key components in advanced electronics and photovoltaics. Increasing demands on efficiency, miniaturization and ever shorter time-to-market require tailored glass-silver-pastes. In these pastes, low-melting glasses act as a sintering aid achieving better sintering, adhesion and contact formation for solar cells. Yet, the related liquid phase sintering of silver-glass-composites and the underlying mechanism of silver dissolution, transport and reprecipitation are rarely investigated. In this study, systematically varied low melting alkaline zinc borate, alkaline earth borate, and Pb- and Bi-glasses are investigated. Glass transition and crystallization are studied with dilatometry, DTA and XRD. Sintering of the pure glasses, pure silver and silver-glass-composites is analyzed with Hot Stage Microscopy, optical and electron microscopy. Since oxygen dissolved in silver powders can affect the silver dissolution as silver oxide in the matrix oxide glasses, the O2-content of silver powders is determined by Vacuum Hot Extraction. The glass transition temperature of the glasses under study varies between 370 °C and 590 °C whereas the sinter onset largely ranges between 400 °C and 600 °C. On the other hand, it scattered between 200 °C and 450 °C for selected commercial Ag-powders of different particle size and morphology.
Sintered bioactive glass scaffolds of defined shape and porosity, e.g. made via additive manufacturing, must provide sufficient bioactivity and sinterability. As higher bioactivity is often linked to high corrosion and crystallization tendency, a certain compromise between sintering ability and bioactivity is therefore required. Groh et al. developed a fluoride-containing bioactive glass (F3), which allows fiber drawing and shows a bioactivity well comparable to that of Bioglass®45S5.
To study whether and to what extent the sinterability of F3 glass powder is controlled by particle size, coarse and fine F3 glass powders (300-310µm and 0-32µm) were prepared by crushing, sieving and milling. Sintering, degassing and phase transformation during heating were studied with heating microscopy, vacuum hot extraction (VHE), DTA, XRD, and SEM.
For the coarse glass powder, sintering proceeds slowly and is limited by surface crystallization of primary Na2CaSi2O6 crystals. Although the crystallization onset of Na2CaSi2O6 is shifted to lower temperature, full densification is attained for the fine powder. This finding indicate that certain porosity might be tuned via particle size variation. Above 900°C, intensive foaming is evident for the fine powder. VHE studies revealed that carbon species are the main foaming source.
Quality Aspects of Additively Manufactured Medical Implants - Defect Detection in Lattice Parts
(2019)
Additive Manufacturing technologies are developing fast to enable a rapid and flexible production of parts. Tailoring products to individual needs is a big advantage of this technology, which makes it of special interest for the medical device industry and the direct manufacturing of final products. Due to the fast development, standards to assure reliability of the AM process and quality of the printed products are often lacking. The EU project Metrology for Additively Manufactured Medical Implants (MetAMMI) is aiming to fill this gap by investigating alternative and cost efficient non-destructive measurement methods.