4 Material und Umwelt
Filtern
Erscheinungsjahr
- 2023 (27) (entfernen)
Dokumenttyp
Referierte Publikation
- nein (27) (entfernen)
Schlagworte
- Per- and Polyfluoroalkyl substances (PFAS) (7)
- Combustion Ion Chromatography (4)
- Deponie (4)
- Kunststoffdichtungsbahn (4)
- Spannungsrissbeständigkeit (4)
- PFAS (3)
- Remediation (3)
- Rostasche (3)
- Soil (3)
- Anerkennungen (2)
- Beschleunigte Alterung (2)
- Kunststoffrasen (2)
- Lysimeter (2)
- Mechanochemical treatment (2)
- Mikroplastik (2)
- Richtlinien (2)
- Sewage sludge (2)
- Sorption (2)
- TED-GC/MS (2)
- X-ray absorption near-edge structure (XANES) spectroscopy (2)
- XANES (2)
- Zulassungen (2)
- Abfallbehandlung (1)
- Antimony (1)
- Bottom ash (1)
- Comsumer good samples (1)
- Construction and demolition waste (1)
- Electrochemical remediation (1)
- Emissions (1)
- Environmental analysis (1)
- Ersatzbaustoff (1)
- Ersatzbaustoffe (1)
- Fertilizer (1)
- Ground water (1)
- Groundwater (1)
- Incineration bottom ash (1)
- Jig (1)
- LC-MS/MS (1)
- Leaching (1)
- Permeable reactive barriers (1)
- Phosphorus (1)
- Plant-availability (1)
- Recycling (1)
- Road construction waste (1)
- Röntgenspektroskopie (1)
- Secondary building materials (1)
- Soil-like material (1)
- Speziierungsanalyse (1)
- Sum parameter analysis (1)
- Synchotron (1)
- Synchrotron (1)
- Thermal treatment (1)
- Uranium mining (1)
- Vanadium (1)
- Water analysis (1)
- Wet-mechanical treatment (1)
- XANES spectroscopy (1)
- XRF (1)
Organisationseinheit der BAM
- 4.3 Schadstofftransfer und Umwelttechnologien (27) (entfernen)
Eingeladener Vortrag
- nein (13)
The amount of plant-available phosphorus (P) in soil strongly influences the yield of plants in agriculture. Therefore, various simple chemical extraction methods have been developed to estimate the plant-available P pools in soil. More recently, several experiments with the DGT technique have shown that it has a much better correlation to plant-available P in soils than standard chemical extraction methods (e.g. calcium-acetate-lactate (CAL), Colwell, Olsen, water) when soils with different characteristics are considered. However, the DGT technique cannot give information on the plant-available P species in the soil. Therefore, we combined DGT with solution 31P nuclear magnetic resonance (NMR) spectroscopy. This was achieved by using a modified DGT device in which the diffusive layer had a larger pore size, the binding layer incorporated an adsorption material with a higher capacity, and the device had a larger exposure area. The spectroscopic investigation was undertaken after elution of the deployed DGT binding layer in a NaOH solution. Adsorption tests using solutions of known organic P compounds showed that a sufficient amount of these compounds could be adsorbed on the binding layer in order for them to be analyzed by solution 31P NMR spectroscopy. Furthermore, various intermediates of the hydrolysis of trimetaphosphate in soil could be also analyzed over time.
Over the past century, a range of synthetic compounds have been produced to improve humanity’s quality of life. These include pharmaceuticals, plastics, and other chemical compounds that possess properties making them potentially harmful when released to the environment (e.g., ecological and health impacts to humans and animals). Per- and polyfluoroalkyl substances (PFAS) are a large group of chemicals used in the formulations of thousands of consumer goods, including aqueous film-forming foams used to suppress aviation fires in training scenarios, non-stick cookware, fast-food wrappers, water-repellent fabrics, medical equipment, and plastic and leather products. Because of the recent regulations and restrictions on the use of long chain (≥C8) PFAS a significant shift in the industry towards short (C4-C7) and ultrashort (C1-C3) chain alternatives has been recognized the last years. Due to the high polarity and water solubility of ultrashort PFAS, the potential for bioaccumulation is low. However, the high persistence of ultrashort-chain PFAS will result in environmental accumulation, especially in aquatic environments, leading to potential risks for aquatic organisms and increased human external exposure through drinking water. Ultrashort PFAS like trifluoroacetic acid (TFA) are low to moderately toxic to a range of organisms. In addition, ultrashort PFAS can penetrate natural and anthropogenic barriers and eventually reach drinking water sources. Because common drinking water treatment techniques do not sufficiently remove them, they may reach human consumption. In the project we are focusing on detecting and removing PFAS, especially ultrashort-chain PFAS from contaminated groundwater. We are designing passive sampling devices, which can collect and monitor the temporal profile of PFAS species in groundwater. This will allow us to analyze PFAS contaminations in German and Israeli groundwater using state-of-the-art and novel analytical techniques and understand the extent of contamination. In addition to quantification, PFAS contaminated groundwater will be treated via a two-stage process to produce PFAS-free drinking water. As ultrashort-chain PFAS are difficult to analyze with the current target (LC-MS/MS) and sum parameter (AOF, EOF) analysis methods, we additionally using gas chromatography – mass spectrometry (GC-MS). Therefore, an analytical method based on GC-MS is in development to analyze the volatile ultrashort-chain PFAS (TFA, PFPrA, TFMS, PFEtS, PFPrS, trifluoroethanol, pentafluoropropanol and hexafluoro isopropanol) directly in contaminated groundwater samples with the headspace technique and in eluates of organic solvents from the developed passive sampler after direct injection. Moreover, a two-stages process is designed to increase the low concentrations found in groundwater using novel membranes processes such as closed-circuit reverse osmosis (CCRO) and mixed matrix composite nanofiltration membranes (MMCM). Next, the rejected streams containing higher concentrations of PFAS will be treated by coagulation, and the remaining PFAS adsorbed onto carbonaceous nanomaterials (CNMs). The DEFEAT-PFAS project will result in the development of novel tools to detect, quantify, and remove PFAS, especially ultrashort-chain PFAS from contaminated groundwater, and will acquire a new understanding of the extent of these contaminations.
Per- and polyfluoroalkyl substances (PFAS) are chemicals which were developed to improve humanity’s quality of life. Due to their high chemical stability and resistance to degradation by heat or acids, PFAS were used in a variety of consumer products. The continuous use of PFAS in household products and the discharge of PFAS from industrial plants into the sewer system resulted in the contamination of effluents and sewage sludge from wastewater treatment plants (WWTPs) (Roesch et al. 2022). Since sewage sludge is often used as fertilizer, its application on agricultural soils has been observed as a significant entry path for PFAS into the environment, specifically in our food chain. In Germany the sewage sludge/biosolid application on agricultural land was banned with the amendment of the German Sewage Sludge Ordinance and by 2029 sewage sludge application will be totally prohibited. However, phosphorus (P) from sewage sludge should still be recycled in WWTPs of cities with a population larger than 50,000 residents. To produce high-quality P-fertilizers for a circular economy, PFAS and other pollutants (e.g. pesticides and pharmaceuticals) must be separated from sewage sludge. Due to the strong diversity of industrial PFAS usage it is not clear if a safe application of novel recycled P-fertilizers from WWTPs can be guaranteed. Therefore, we analyzed various sewage sludges and wastewater-based fertilizers. Sewage sludge (SL) samples from various WWTPs in Germany and Switzerland, six sewage sludge ashes (SSA) from Germany, six thermally treated SL and SSA samples with different additives (temperatures: 700-1050 °C), two pyrolyzed SL samples (temperature: 400 °C) and two struvite samples from Germany and Canada were analyzed. The goal was to quantify PFAS in sewage sludges and wastewater-based P-fertilizers with the sum parameter extractable organic fluorine (EOF) by combustion ion chromatography (CIC). The results were compared with data from classical LC-MS/MS target analysis as well as selected samples by HR-MS suspect screening. The EOF values of the SLs mainly range between 154 and 538 µg/kg except for one SL which showed an elevated EOF value of 7209 µg/kg due to high organofluorine contamination. For the SSA samples the EOF values were lower and values between LOQ (approx. 60 µg/kg) and 121 µg/kg could be detected. For the pyrolyzed SLs no EOF values above the LOQ were detected. Moreover, the two wastewater-based struvite fertilizers contain 96 and 112 µg/kg EOF, respectively. In contrast to the EOF values, the sum of PFAS target values were relatively low for all SLs. Additional applied PFAS HR-MS suspect screening aimed to tentatively identify PFAS that could contribute to the hitherto unknown part of the EOF value. The majority of the detected fluorinated compounds are legacy PFAS such as short- and long-chain perfluorocarboxylic acids (PFCA), perfluorosulfonic acids (PFSA), polyfluoroalkyl phosphate esters (PAPs) and perfluorophosphonic acids (PFPA). Moreover, fluorinated pesticides, pharmaceutical as well as aromatic compounds were also identified, which are all included in the EOF parameter. Our research revealed that the current PFAS limit of 100 µg/kg for the sum of PFOS + PFOA in the German Fertilizer Ordinance is no longer up to date. Since the number of known PFAS already exceeds 10,000, the ordinance limit should be updated accordingly. Recent regulations and restrictions on using long-chain PFAS (≥C8) have resulted in a significant shift in the industry towards (ultra-)short-chain alternatives, and other, partly unknown, emerging PFAS. Ultimately, also fluorinated pesticides and pharmaceuticals, which end up as ultrashort PFAS in the WWTPs, have to be considered as possible pollutants in fertilizers from wastewater, too.
Current decontamination strategies of PFAS-burdened soils mainly consist of adsorption methods using adsorbents for fixation of PFAS in the ground. A second option is the utilization of a “pump and treat” process, cycling polluted soils through a washing plant leading to the concentration of the pollutants in the fine fraction. Only a subsequent, high-energy consuming pyrolysis process guarantees the total destruction of all fluorinated organic contaminants. These approaches are cost-intensive and not intended for the direct decomposition of all PFAS contaminants. Hence, there is a great demand for innovative developments and chemical treatment technologies, dealing with new strategies of tackling the PFAS problem. Thus, we investigated mechanochemical treatment of PFAS contaminated soils with various additives in a ball mill and analyzed the PFAS defluorination with gas chromatography mass spectrometry (GC-MS) and liquid chromatography tandem mass spectrometry (LC-MS/MS), respectively, as well as the fluoride mineralization by ion chromatography (IC) and fluorine K-edge X-ray absorption near-edge structure (XANES) spectroscopy.
Sustainability has become the conscientious and future-oriented principle of modern resource management and environmental protection because caring for the future is tantamount to providing manageable and healthy surroundings for ourselves. For the foreseeable future, geotechnical and environmental engineers must therefore be concerned with ensuring a healthy balance between extraction, processing, manufacturing, utilization, recycling, and disposal of materials and products.
Wie können industriell synthetisierte Schadstoffe aus einer Stoffklasse quantifiziert werden, deren genauer Umfang unbekannt ist und auf mehrere tausend Verbindungen geschätzt wird? Im Falle der per- und polyfluorierten alkylierten Substanzen (PFAS) stellen sich Wissenschaftler*innen weltweit seit über zehn Jahren diese Frage. Neben der etablierten Methodik der Einzelstoffanalytik (engl. target analytic) existieren Summenparameteranalysen zur Quantifizierung
organisch gebundener fluorierter Verbindungen in Umweltmedien und Konsumprodukten. An der Bundesanstalt für Materialforschung und -prüfung (BAM) beschäftigen wir uns mit der Weiterentwicklung von Summenparametermethoden am Beispiel von PFAS-belasteten Umweltkompartimenten wie Böden, Klärschlämmen und Gewässerproben sowie PFAS-haltigen Konsumgütern. In diesem Beitrag stellen wir zwei ausgewählte Fallbeispiele vor und diskutieren die Vor- und Nachteile der Methoden im Vergleich zur Einzelstoffanalytik.
Besides classical per- and polyfluorinated alkylated substances (PFAS), side-chain fluorinated polymers (SFPs) are widely applied as efficient anti-wetting and anti-greasing coatings in various daily applicated consumer products such as outdoor apparel, carpetry or paper-based food contact materials. Although the fluorinated sidechains are chemically bound to a base polymer, their release can be triggered by environmental influences or wear-off, thus contribute as significant sources of PFAS in the environment. Since only little knowledge of PFAS and SFP composition in consumer products is available, a comprehensive analytical approach might be beneficial.