4 Material und Umwelt
Filtern
Dokumenttyp
- Zeitschriftenartikel (4)
- Vortrag (3)
- Beitrag zu einem Tagungsband (1)
- Posterpräsentation (1)
Sprache
- Englisch (9) (entfernen)
Schlagworte
- Ecotoxicity (3)
- HP14 (3)
- Leaching (3)
- Recycling materials (3)
- Analytical methods (1)
- Antimony (1)
- Construction products (1)
- DSLT (1)
- Ecotoxicological tests (1)
- Groundwater (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (3)
Draft standards for the determination of organic pollutants in the solid matter of environmental matrices such as sludge, treated biowaste and soil have been basically developed in the framework of the European standardization project HORIZONTAL. A research project financed by the German Federal Environment Agency was initiated to finalize some of these CEN standard drafts, since fully validated standard procedures are crucial for the evaluation of their reliability in the context of implementation in legislation on environmental health.
Approach: Appropriate test materials (< 2mm particle size) were prepared and homogenized from contaminated soils, sludge and treated biowaste containing polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), dioxins, furans and dioxin-like-PCB and served, along with reference solutions, as the basis for international interlaboratory comparisons. Performance data of three analytical standard procedures were obtained by the statistical evaluation of results received from 11 to 29 participants per test material.
Results: The overall variation coefficients of reproducibility (between-lab standard deviations) for the sum parameters were roughly between 10 and 35 %. The variation coefficients of repeatability (within-lab standard deviations) range between 3 % and 8 % and show no trend considering the substance groups or matrices.
The highest coefficients of reproducibility were found for the analysis of PAHs, which were between 26 and 35 %, depending on the matrix, whereas 7-17 % reproducibility was observed for toxicity equivalents (TEQ) comprising dioxins, furans and dl-PCB.
Conclusions: Overall, the results confirm that the procedures described in the Technical Specifications are fit for purpose for all three matrices and that the feasibility of the HORIZONTAL approach, to cover several matrices with one standard per analyte, was thereby proven.
Construction products are in contact with water (e.g., rain, seepage water) during their service lifetime and may release potentially harmful compounds by leaching processes. Monitoring studies showed that compounds attributed to construction products are found in storm water and the receiving bodies of water and that the release of biocides in urban areas can be comparable to the input of pesticides from agricultural uses. Therefore, a prospective risk assessment of such products is necessary. Laboratory leaching tests have been developed by the Technical Committee CEN/TC 351 and are ready to use. One major task in the future will be the evaluation of the leaching test results, as concentrations found in laboratory experiments are not directly comparable to the field situations. Another Task will be the selection of compounds to be considered for construction products, which are often a complex mixture and contain additives, pigments, stabilization agents, etc. The formulations of the products may serve as a starting point, but total content is a poor predictor for leachability, and analysis of the eluates is necessary. In some cases, nontargeted approaches might be required to identify compounds in the eluates. In the identification process, plausibility checks referring to available information should be included. Ecotoxicological tests are a complementary method to test eluates, and the combined effects of all compounds—including Degradation products—are included. A bio test battery has been applied in a round robin test and was published in a guidance document. Published studies on the ecotoxicity of construction products show the tests’ suitability to distinguish between products with small and larger effects on the environment.
Column leaching tests are frequently used and accepted for investigation of release of hazardous substances from solid materials. Independent of differences due to the field of application or national regulations, column tests assume that local equilibrium is established in the experiment which facilitates transfer of results to field conditions. In the process of harmonization and standardization within Europe the question on the influence of flow rate and grain size distribution on the local equilibrium was raised. Thus, a set of experiments using two different masonry materials with varying grain size distribution and flow rate were conducted including stop/flow experiments. Results are compared to a numerical model which takes intraparticle pore diffusion-controlled release of Mo and V into the percolating water into account. Due to the relatively high intraparticle porosity of the materials (24–29%) data and model indicate that initially equilibrium-state conditions prevail followed by rapidly decreasing concentrations. The model fits data for Mo and V reasonably well; however, after the initial decline of concentrations (at L/S > 2) extended tailing is observed especially of elements occurring as oxides, which is not captured by the model.
Leachiing tests - a useful tool for the environmental impact assessment of construction products?
(2018)
Construction products and waste materials used for construction can be in contact with the environment and may release potential harmful compounds. Information on the total content of these substances in the product is not sufficient to assess its envrionmental impact since it does not consider realistic exposure conditions.The impact of these compounds is often assessed by using the total content in the product. This estimation lacks realistic exposure conditions.
Concerning the pathway to soil and groundwater by contact with rain or seepage water leaching tests, which were developed and standardized by the European Committee for Standardization, are available. While for secondary construction products and waste this investigation of the leaching behaviour is standard procedure and is already part of regulation in Germany (draft ordinance on reuse of mineral waste) and within Europe (landfill directive) the release from primary construction products got in the focus more recently. Several monitoring studies found unexpected high concentrations of substances used as herbicides and fungicides in surface water and stormwater originating from urban areas. As some of these compounds are even banned for the use in agricultural applications in Europe alternative sources as roof materials and façade coatings exposed to rain were suggested. Further field and laboratory tests confirmed construction products as sources of these substances in water.
The aim of this presentation is to show exemplary results of existing leaching methods and underline the strength and weaknesses of the test system with selected examples from our work. We especially draw the attention to the research which is still needed to close the gap between the results of leaching experiments and the subsequent risk assessment of the products.
The presentation gives an overview about the use of ecotoxicity testing in assessment of waste. Especially in cases with unknown composition this kind of test are useful. Recently, the assessment of the hazard property HP 14 "ecotoxicity" for the labelling of waste was published. The labelling procedure is explained in detail.
The presentation gives an overview about the use of ecotoxicity testing in assessment of waste. Especially in cases with unknown composition this kind of test are useful. Recently, the assessment of the hazard property HP 14 "ecotoxicity" for the labelling of waste was published. The labelling procedure is explained in detail.
The presentation gives an overview about the use of ecotoxicity testing in assessment of waste. Especially in cases with unknown composition this kind of test are useful. Recently, the assessment of the hazard property HP 14 "ecotoxicity" for the labelling of waste was published. The labelling procedure is explained in detail.