Any surface in the environment acts as hotspot for microbial attachment and activity. These biofilms represent the interface between humans and the environment.
While in the past biofilms were often seen as disturbance, we now start to understand the enormous potential of beneficial biofilms. They can be used in a broad range of applications and are sources for new microorganisms and traits. After all, biofilms represent a great example for a collaborative lifestyle.
The Microplastic Microbiome
(2024)
Microplastics represent man-made and newly emerging surfaces in our ecosystems, where they interact with microorganisms. The ecosystem in focus of this presentation will be the aquatic environment. It will be portrayed, which microorganisms use microplastics as a habitat, how environmental factors shape this colonization, and why the biodegradation of plastics in the ocean is an overall unlikely process. We will also discuss whether potentially pathogenic microorganisms use microplastics as a raft. Finally, possible adaptation mechanisms of plastic-colonizing microorganisms will be presented, such as the production of photoreactive molecules. The microplastic microbiome has a large potential to harbor so far unknown species with curious traits, representing an exciting research topic for the future.
The BAM Data Store
(2023)
As a partner in several NFDI consortia, the Bundesanstalt für Materialforschung und -prüfung (BAM, German federal institute for materials science and testing) contributes to research data standardization efforts in various domains of materials science and engineering (MSE). To implement a central research data management (RDM) infrastructure that meets the requirements of MSE groups at BAM, we initiated the Data Store pilot project in 2021. The resulting infrastructure should enable researchers to digitally document research processes and store related data in a standardized and interoperable manner. As a software solution, we chose openBIS, an open-source framework that is increasingly being used for RDM in MSE communities.
The pilot project was conducted for one year with five research groups across different organizational units and MSE disciplines. The main results are presented for the use case “nanoPlattform”. The group registered experimental steps and linked associated instruments and chemicals in the Data Store to ensure full traceability of data related to the synthesis of ~400 nanomaterials. The system also supported researchers in implementing RDM practices in their workflows, e.g., by automating data import and documentation and by integrating infrastructure for data analysis.
Based on the promising results of the pilot phase, we will roll out the Data Store as the central RDM infrastructure of BAM starting in 2023. We further aim to develop openBIS plugins, metadata standards, and RDM workflows to contribute to the openBIS community and to foster RDM in MSE.
Regional standardisation activities and how VAMAS can help in any way to promote activities are reported.
Activities related to organisational updates, government initiatives/priorities (especially related to Materials), details of any strategy documents publicly available, networks within Germany and how we engage are presented.
This presentation was held in an OECD Webinar introducing the newly developed and published OECD TG 125 on particle size and size distribution. The presentation is explaining the structure if the TG 125 and addresses all included methods and methodologies in a short and understandable way for the broader public. The presentation includes sections about nano-particles and nano-fibres.
Each year, an immense amount of plastic debris enters marine ecosystems, much of which ends up in the Great Pacific Garbage Patch (GPGP). The plastic fragments are home to a diverse community of microorganisms, and while researchers have gained a better understanding of these marine plastic biofilms, we lack insights into the physiology and genomic potential of the bacteria that colonize them. Examining the lifestyle of plastic colonizers from the GPGP is particularly intriguing, as the high concentration of plastics in this accumulation zone might allow for a microbial adaptation to this unique man-made habitat. A range of pigmentation was observed in 67 isolated strains obtained directly from plastic pieces sampled from the GPGP surface water. Sequence comparison between the cultivated bacterial strains and the 16S rRNA gene amplicon dataset confirmed that most of the cultivates could also be captured through DNA-only methods. Whole genome analysis of four taxonomically diverse representatives revealed multiple carotenoid pathways, including those to produce less common glycosylated carotenoids, like sarcinaxanthin glucoside. Further, we identified a potentially new Rhodobacteraceae species containing a photosynthetic gene cluster (PGC). Absorption analysis confirmed the actual production of the carotenoids and bacteriochlorophyll a. Floating plastics represent a habitat with strong UV-light exposure, making the protection with antioxidant carotenoids as well as the ability to use light as an energy source highly beneficial traits for plastic colonizers. Our findings indicate, that the production of pigments is a common adaption mechanism for plastic-associated bacteria, and that plastic biofilms present a so far overlooked source of rare carotenoids and light-harvesting mechanisms.
The presentation gives general information about the European Standard EN 16516 “Construction products – Assessment of release of dangerous substances – Determination of emissions into indoor air”. This test standard was developed based on the mandate M/366 of the European commission and is a horizontal reference method for the determination of volatile organic compounds (VOC) from different classes of construction (building) products. Specific test conditions are to be selected by the product TCs (technical committees) in a way that a product is tested under its intended condition of use.
The test is based on the use of emission test chambers which are operated at constant air change rate and climate (23°C, 50 % r.h.) over 28 days. The standard defines the conditions and requirements for the measurement including loading factor, air change rate, sampling, analysis and calculation of emission rates of the substances. A 30 m³ reference room is described which is used to calculate air concentrations from the determined emission rates.
The standard EN 16516 enables the evaluation of construction products regarding their emissions into indoor air under defined and comparable conditions. The evaluation includes the determination of identified target compounds, non-identified target compounds, volatile carcinogenic compounds and the sum values TVOC, TSVOC and R.
In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. VOC in combination may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. Emission concentrations can become further elevated in new or refurbished buildings where the rate of air exchange with fresh ambient air may be limited due to improved energy saving aspects. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use (building) materials proved to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable emission reference materials (ERM). For the emission test chamber procedure according to EN 16516, no artificial ERM is commercially available. The EU-funded EMPIR project MetrIAQ aims to fill this gap by developing new and improved ERMs. The goal is to obtain a material with a reproducible and temporally constant compound release (less than 10% variability over 14 days). Different approaches, such as the impregnation of porous materials, are being tested. The generation as well as results of the most promising materials will be presented.
Nonporous corundum powder was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices.The common crosslinker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter was oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). As a proof of concept, IgG was extracted with protein A from crude human plasma. The advantages of corundum include the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, convenient handling, and flexible application.
Micro-(nano-)encapsulation technology involves building of a barrier between the core and the environment and offers a number of benefits to preserve the functional and physicochemical properties of core material. Tremendous progress has been made in synthesizing well-defined capsules to achieve desired properties such as particle size, chemical composition, and controlled release of the payload.
Encapsulation of volatile organic compounds (VOCs) that could evaporate with a defined rate is of immense interest for application in emission reference materials (ERM). These are urgently needed for quality assurance and quality control purposes (QA/QC) required by test standards for the determination of chemical emissions of construction and other materials for interior use. As such ERMs are hardly available on the market, the EU-funded EMPIR project MetrIAQ [1] was started to fill this gap by developing a material with temporally constant emission of VOCs typically found in indoor air.
Different capsules in a size range between 5 and 50 μm were synthesized through an interfacial polyaddition/polycondensation reaction in direct (water-in-oil) system. As VOC several types of hydrophobic liquid materials were used. After synthesis, the morphology and physicochemical properties of capsules were characterized by electron microscopy, FTIR and DSC/TGA. An encapsulation efficiency up to 90% could be reached. The emission kinetic of volatile agents was studied in emission test chambers at 23 °C and 50% RH for 14 days. First results indicate that variation of the cross-linking grade of the shell material is one important parameter to adjust the desired emission rate. The overall aim is to achieve a consistent emission profile that decreases by less than 10 % over a target period of at least 14 days.
Micro-(nano-)encapsulation technology involves building a barrier between the core and the environment and offers several benefits to preserve the functional and physicochemical properties of core material. Tremendous progress has been made in synthesizing well-defined capsules to achieve desired properties such as particle size, chemical composition, and controlled release of loaded compounds.
Encapsulation of volatile organic compounds (VOCs) that could evaporate with a defined rate is of immense interest for application in emission reference materials (ERM). These are urgently needed for quality assurance and quality control purposes (QA/QC) required by test standards for the determination of chemical emissions of construction and other materials for interior use. As such ERMs are hardly available on the market, the EU-funded EMPIR project MetrIAQ was started to fill this gap by developing a material with temporally constant emission of VOCs typically found in indoor air.
Data for the publication "The role of extracellular polymeric substances of fungal biofilms in mineral attachment and weathering" (https://doi.org/10.1038/s41529-022-00253-1). It includes:
- The Summary of the EPS concentration, EPS sugar components and EPS linkages.
- The Summary of the XPS analysis of freeze-dried biofilm samples of all strains.
- The Summary of the pH, Mg, SI and Fe concentration, biomass and olivine dissolution rate for each time point of all dissolution experiments.
Since 1997, the Committee for Health-related Evaluation of Building Products (AgBB) has been developing the basis for building regulations for protection against indoor health risks that may arise when building products are used. In 2009, the AgBB decided to include relevant VVOCs in the assessment procedure. The ISO 16000-6 (2021) states that the use of the thermal desorption gas chromatography technique is appropriate for VVOCs, if adaptations are considered. However, a suitable method for the trustworthy quantification of VVOC emissions from building products and in the indoor air is still missing.
This webinar will present the results of a research project on the development of a procedure for VVOC analysis:
• identification of the gaps towards standardization
• investigations on gas standards and the suitability of chromatography columns
• investigations on sorbent combinations and water management
• validation of the method and screening of VVOC emissions from building products.
The diversity of fused filament fabrication (FFF) filaments continues to grow rapidly as the popularity of FFF-3D desktop printers for the use as home fabrication devices has been greatly increased in the past decade. Potential harmful emissions and associated health risks when operating indoors have induced many emission studies. However, the lack of standardization of measurements impeded an objectifiable comparison of research findings. Therefore, we designed a chamber-based standard method, i.e., the strand printing method (SPM), which provides a standardized printing procedure and quantifies systematically the particle emission released from individual FFF-3D filaments under controlled conditions. Forty-four marketable filament products were tested. The total number of emitted particles (TP) varied by approximately four orders of magnitude (1E9 ≤ TP ≤ 1E13), indicating that origin of polymers, manufacturer-specific additives, and undeclared impurities have a strong influence. Our results suggest that TP characterizes an individual filament product and particle emissions cannot be categorized by the polymer type (e.g., PLA or ABS) alone. The user's choice of a filament product is therefore decisive for the exposure to released particles during operation. Thus, choosing a filament product awarded for low emissions seems to be an easily achievable preemptive measure to prevent health hazards.
Healthy and energy efficient buildings must be free from disturbing odours. Odour emissions from building materials can be measured with the well-known and accepted standard ISO 16000-28 “Indoor air – Part 28: Determination of odour emissions from building products using test chambers”. For commonly used emission test chambers the sample air is collected in containers (bags) and presented to a group of panel members for the purpose of evaluating the odour. A standard sets requirements for the on-demand presentation in detail. These include the validation procedure for container materials, pre-treatment of bags, details on storage of filled bags and how to carry out the measurements. However, although these measures are proven in practice, incorrect measurements are still possible. Also errors can occur due to a very complex measurement procedure. So, there is a great need for research into how the odour samples are presented.
The proposal planned to be presented will introduce a new development in sample provision by using an adapter which enables collection and provision of sample air without storage or transport of bags. The adapter is a sample container which is permanently positioned on the emission test chamber´s outlet and continuously filled with sample air flowing through it. The flow is briefly interrupted at the time when a sample is taken by a panel member for the test.
The size of the container is sufficient to provide enough sample air for evaluation by at least one panel member via a funnel. Since sampling and presentation are technically connected, it means you can almost do away with storage or transportation and thus it can be presented almost unchanged to the panelmembers. The aim is to reduce measurement errors in the odour samples provision process and the improvement of measurement reproducibility. The paper presents the construction of the adapter as well as the results of emission and odour tests carried out so far.
One criterion to evaluate the odour of a sample is perceived
intensity П which is evaluated with the aid of a comparative scale. The procedure is well accepted but also time consuming and extensive. The study should help simplify the testing procedure by asking the panel members to only indicate whether a sample is perceived as less to equally intense or of greater intensity in comparison to a given acetone concentration of 7 pi on the comparative scale. In Germany a value of 7 pi is required for products to be suitable for the indoor use. The results show that the simplified test is basically suitable.
BAM is currently building up a platform of novel nanoRMs relying on iron oxide nanoparticles of different shape, size and surface chemistry. Iron oxide was chosen as a core material because of its relevance to the material and life sciences.
As a first candidate of this series, we present cubic iron oxide nanoparticles with a nominal edge length of 8 nm. These particles were synthesized by thermal decomposition of iron oleate in high boiling organic solvents adapting well-known literature procedures. After dilution to a concentration suitable for electron microscopy (TEM and SEM) as well as for small-angle X-ray scattering (SAXS) measurements, the candidate nanoRM was bottled and assessed for homogeneity and stability by both methods following the guidelines of ISO 17034 and ISO Guide 35.
The particle sizes obtained by both STEM-in-SEM and TEM are in excellent agreement with a minimum Feret of 8.3 nm ± 0.7 nm. The aspect ratio (AR) of the iron oxide cubes were extracted from the images as the ratio of minimum Feret to Feret resulting in an AR of 1.18 for TEM to 1.25 for SEM. Alternatively, a rectangular bounding box was fitted originating from the minimum Feret and the longest distance through the particle in perpendicular direction. This led to AR values of 1.05 for TEM and 1.12 for SEM, respectively. The results confirm the almost ideal cubic shape.
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids are used to introduce functional groups for further conjugations. The common cross-linker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter is oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower nonspecific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by SDS-PAGE. A binding capacity of 1.8 mg IgG per g of corundum powder was achieved. The advantages of corundum are the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, and flexible application.
Several aspects were explored towards the standardization of a suitable procedure. The use of gaseous standards is necessary and a standard gas mixture containing 60 substances was successfully generated and employed for further investigations. The suitability of different chromatography columns was addressed: The use of PLOT (Porous Layer Open Tubular) columns is well suitable for VVOC analysis. The recoveries of the 60 analytes on several adsorbents and their combinations were determined: A combination of a graphitized carbon black and a carbon molecular sieve showed great results for all analytes. Carbon molecular sieves adsorb water which can impair the analysis. Different options such as purging, the use of a drying system or splitting were investigated for water removal. This contribution will present experimental results supporting the standardization of a method for VVOC analysis.