4 Material und Umwelt
Filtern
Erscheinungsjahr
- 2022 (37) (entfernen)
Dokumenttyp
Schlagworte
- Leaching (6)
- PFAS (4)
- Transformation (4)
- XANES spectroscopy (4)
- Anerkennungen (3)
- Construction products (3)
- Per- and Polyfluoroalkyl substances (PFAS) (3)
- Rostasche (3)
- Zulassungen (3)
- Abdichtungssystem (2)
Organisationseinheit der BAM
- 4.3 Schadstofftransfer und Umwelttechnologien (37) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (14)
Here, we describe an optimized fast and simple extraction method for the determination of per- and polyfluorinated alkyl substances (PFASs) in soils utilizing high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR–CS–GFMAS). To omit the bias of the solid phase extraction (SPE) step commonly used during the analysis of extractable organically bound fluorine (EOF) we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol without any additional SPE. Four extraction steps were representative to determine a high proportion of the EOF (>80% of eight extractions). Comparison of the optimized method with and without an additional SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. Differences of up to 94% were observed which were not explainable by coextracted inorganic fluoride. Therefore, not only a more accurate but also a more economic as well as ecologic method (bypassing of unnecessary SPE) was developed. The procedural limit of quantification (LOQ) of the developed method was 10.30 μg/kg which was sufficient for quantifying EOF concentrations in all tested samples. For future PFAS monitoring and potential regulative decisions the herein presented optimized extraction method can offer a valuable contribution.
The main obstacle to bottom ash (BA) being used as a recycling aggregate is the content of salts and potential toxic elements (PTEs), concentrated in a layer that coats BA particles. This work presents a dry treatment for the removal of salts and PTEs from BA particles. Two pilotscale abrasion units (with/without the removal of the fine particles) were fed with different BA samples. The performance of the abrasion tests was assessed through the analyses of particle size and moisture, and that of the column leaching tests at solid-to-liquid ratios between 0.3 and 4. The results were: the particle-size distribution of the treated materials was homogeneous (25 wt % had dimensions <6.3 mm) and their moisture halved, as well as the electrical conductivity of the leachates. A significant decrease was observed in the leachates of the treated BA for sulphates (44%),
chlorides (26%), and PTEs (53% Cr, 60% Cu and 8% Mo). The statistical analysis revealed good correlations between chloride and sulphate concentrations in the leachates with Ba, Cu, Mo, and Sr, illustrating the consistent behavior of the major and minor components of the layer surrounding BA particles. In conclusion, the tested process could be considered as promising for the improvement of BA valorization.
Der Fachbeirat kommt bereits seit 13 Jahren in seiner jetzigen Form zusammen, um Zulassungsrichtlinien, weitere Dokumente und fachliche Fragestellungen zu beraten. Die Zeit bringt auch personelle Veränderungen mit sich, darüber wollen wir berichten. Derzeit wird die Zulassungsrichtlinie für Schutzschichten im Fachbeirat und in seiner Arbeitsgruppe Geotextilien und Kunststoff Dränelemente (AG Geotextilien) überarbeitet. Zudem wurde die Zulassungsrichtlinie für Kunststoffdichtungsbahnen auf den aktuellen Stand der Regelsetzung und Normung gebracht. Bestimmte Medien, die hier bei einigen Prüfungen verwendet werden, dürfen nicht mehr in der EU in Verkehr gebracht werden. Hier werden die Hintergründe und Zusammenhänge in Kürze aufgezeigt. Zuletzt wird die Diskussion in Bezug auf den Einsatz von Rezyklaten in den zugelassenen Produkten aufgeführt.
Der Fachbeirat kommt bereits seit 13 Jahren in seiner jetzigen Form zusammen, um Zulassungsrichtlinien, weitere Dokumente und fachliche Fragestellungen zu beraten. Die Zeit bringt auch personelle Veränderungen mit sich, darüber wollen wir berichten. Derzeit wird die Zulassungsrichtlinie für Schutzschichten im Fachbeirat und in seiner Arbeitsgruppe Geotextilien und Kunststoff Dränelemente (AG Geotextilien) überarbeitet. Zudem wurde die Zulassungsrichtlinie für Kunststoffdichtungsbahnen auf den aktuellen Stand der Regelsetzung und Normung gebracht. Bestimmte Medien, die hier bei einigen Prüfungen verwendet werden, dürfen nicht mehr in der EU in Verkehr gebracht werden. Hier werden die Hintergründe und Zusammenhänge in Kürze aufgezeigt. Zuletzt wird die Diskussion in Bezug auf den Einsatz von Rezyklaten in den zugelassenen Produkten aufgeführt.
Per- and polyfluoroalkyl substances (PFAS) have emerged over the course of the last twenty years as a global pollution issue. Altogether, there are currently more than 4700 known but only partly characterized fluorinated compounds identified by the Organization for Economic Cooperation and Development (OECD), as shown by a recently published classification proposal.
The ongoing production of new, yet unrestricted PFAS alternatives has become a major challenge for environmental routine analytics, since the state-of-the-art method LC-MS/MS relies on structural information and availability of isotope standards of the targeted compound. First reported by Miyake et al., fluorine sum parameters like adsorbable organic fluorine (AOF), extractable organic fluorine (EOF) and total fluorine (TF) can be applied to survey and detect the presence of large amounts of unidentified organofluorine compounds in environmental matrices. Today fluorine sum parameters have been established as a useful supplement to classic target-analytical approaches of PFAS and were implemented for the first time as a sum value “PFAS-total” in the recently revised Drinking Water Directive (2020/2184) by the European Commission.
In contrast, X-ray absorption near-edge structure (XANES) spectroscopy has been widely applied to identify low concentration of element-specific contamination without pre-treatment in environmental samples in the past. The XANES approach enables a penetration depth of approx. 1 µm (at fluorine K-edge energy; depending on the matrix) which is significantly deeper than for X-ray photoelectron spectroscopy (XPS; penetration depth approx. 10 nm). Furthermore, the method is fast, non-destructive and only simple preparation of the samples is required.
In our work, we combined both F-XANES spectroscopy and combustion ion chromatography (CIC) in order to present a new analytical perspective on the investigation of PFAS in environmental media and material samples.
Analytical Challenges for PFAS in Environmental Samples - Methods, Approaches and Applicability
(2022)
Per- and polyfluoroalkyl substances (PFAS) are anionic, cationic and zwitterionic synthetic products, in which the hydrogen atoms on the carbon skeleton of at least one carbon atom have been completely replaced by fluorine atoms and which include up to 1.7 M compounds, depending on the definition. As a result of continuous and prolific use, mainly in aviation firefighting foams, thousands of industrial and military installations have been found to contain contaminated soil, groundwater and surface water. Furthermore, because of the continuous contamination through PFAS containing commercial products, effluents and sewage sludge from WWTPs have been shown to be an important source of PFAS discharge into the aquatic environment. In the last few years, legacy PFAS (≥C4) have been found in various environments, including soil, water and wastewater, and their environmental pathways have been partly described.
Several long-chain PFAS species, and their respective salts are considered as persistent organic pollutants by the United Nations Stockholm Convention. These pollutants have been linked to altered immune and thyroid function, liver disease, lipid and insulin dysregulation, kidney disease, adverse reproductive and developmental outcomes, and cancer. A significant shift in the chemical industry towards production of short (C4-C7) and ultrashort (C1-C3) alternatives was observed in response to recently intensified regulations and restrictions on the use of long-chain (≥C8) PFAS. PFAS analysis in environmental samples is currently mainly done by liquid chromatography tandem mass spectrometry (LC-MS/MS). This efficient method is conducted in a targeted fashion analyzing a small subset of PFAS. The US EPA method for analysis of PFAS using LC-MS/MS for example currently lists 40 PFAS (≥C4). However, to get a better overview of the amount of “total PFAS,” sum parameter methods like total oxidizable precursor (TOP) assay and methods based on combustion ion chromatography (CIC) are in development. CIC results in data regarding the sum of absorbable organic fluorine (AOF) or extractable organic fluorine (EOF), which can also quantify other organically bound fluorine compounds such as fluorinated pesticides and pharmaceutical. Moreover, non-target and suspect screening mass spectrometry can be used to identify novel emerging PFAS and partly unknown fluorinated compounds in environmental samples. Furthermore, to analyze ultrashort PFAS (C1-C3), supercritical fluid chromatography (SFC), hydrophilic interaction chromatography (HILIC) and gas chromatography-mass spectrometry (GC-MS) are available, but further research is needed to develop reliable and accurate methods to quantify several ultrashort PFAS in environmental samples.
Additionally, for research purpose several spectroscopical methods like X-ray photoelectron spectroscopy (XPS), fluorine K-edge X-ray absorption near-edge structure (XANES)spectroscopy, particular induced gamma-ray emission (PIGE) spectroscopy and 19F nuclear magnetic resonance (NMR) spectroscopy are available.