4 Material und Umwelt
Filtern
Dokumenttyp
- Zeitschriftenartikel (4)
- Vortrag (4)
- Posterpräsentation (2)
- Beitrag zu einem Tagungsband (1)
- Forschungsbericht (1)
Schlagworte
- Leaching (5)
- Ecotoxicity (3)
- HP14 (3)
- Recycling materials (3)
- DSLT (2)
- Analytical methods (1)
- Antimony (1)
- Auslaugtests (1)
- Auswaschung (1)
- Bauprodukte (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (4)
Draft standards for the determination of organic pollutants in the solid matter of environmental matrices such as sludge, treated biowaste and soil have been basically developed in the framework of the European standardization project HORIZONTAL. A research project financed by the German Federal Environment Agency was initiated to finalize some of these CEN standard drafts, since fully validated standard procedures are crucial for the evaluation of their reliability in the context of implementation in legislation on environmental health.
Approach: Appropriate test materials (< 2mm particle size) were prepared and homogenized from contaminated soils, sludge and treated biowaste containing polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), dioxins, furans and dioxin-like-PCB and served, along with reference solutions, as the basis for international interlaboratory comparisons. Performance data of three analytical standard procedures were obtained by the statistical evaluation of results received from 11 to 29 participants per test material.
Results: The overall variation coefficients of reproducibility (between-lab standard deviations) for the sum parameters were roughly between 10 and 35 %. The variation coefficients of repeatability (within-lab standard deviations) range between 3 % and 8 % and show no trend considering the substance groups or matrices.
The highest coefficients of reproducibility were found for the analysis of PAHs, which were between 26 and 35 %, depending on the matrix, whereas 7-17 % reproducibility was observed for toxicity equivalents (TEQ) comprising dioxins, furans and dl-PCB.
Conclusions: Overall, the results confirm that the procedures described in the Technical Specifications are fit for purpose for all three matrices and that the feasibility of the HORIZONTAL approach, to cover several matrices with one standard per analyte, was thereby proven.
Column leaching tests are frequently used and accepted for investigation of release of hazardous substances from solid materials. Independent of differences due to the field of application or national regulations, column tests assume that local equilibrium is established in the experiment which facilitates transfer of results to field conditions. In the process of harmonization and standardization within Europe the question on the influence of flow rate and grain size distribution on the local equilibrium was raised. Thus, a set of experiments using two different masonry materials with varying grain size distribution and flow rate were conducted including stop/flow experiments. Results are compared to a numerical model which takes intraparticle pore diffusion-controlled release of Mo and V into the percolating water into account. Due to the relatively high intraparticle porosity of the materials (24–29%) data and model indicate that initially equilibrium-state conditions prevail followed by rapidly decreasing concentrations. The model fits data for Mo and V reasonably well; however, after the initial decline of concentrations (at L/S > 2) extended tailing is observed especially of elements occurring as oxides, which is not captured by the model.
Auslaugversuche wurden mit verschiedenen Bauprodukten durchgeführt, die unter Anwendungsbe-dingungen mit Niederschlägen in Kontakt kommen können. In das Testprogramm wurden Lacke für Außenanwendungen, Wärmedämmverbundsysteme, Dachziegel und polymere Dachfolien einbezogen.
Mit diesen Produkten wurden der von CEN TC 351 entwickelte dynamische Oberflächenauslaugtest (DSLT) und Immersionstests nach EN 16105 durchgeführt. Emissionsverläufe wurden sowohl für an-organische Komponenten als auch für organische Substanzen in den Eluaten ermittelt. Auslaugbare organische Substanzen wurden zuvor in Screeningtests identifiziert.
Um die mögliche Freisetzung von Stoffen aus Bauprodukten beurteilen zu können, ist es erforderlich, Emissionsverläufe zu beschreiben. Dazu sind die verwendeten Testverfahren geeignet. Um Baupro-dukte mit einem Blauen Engel als „Produkte mit geringer Auslaugung“ auszuloben, müssen die aus-laugbaren Substanzen komplett bekannt sein. Für organische Verbindungen ist das noch eine Heraus-forderung. Außerdem erfordert die Bewertung der Testergebnisse sowohl Übertragungsmodelle, die Vorhersagen über freisetzbare Stoffmengen unter Anwendungsbedingungen ermöglichen, als auch Vorgaben zu tolerierbaren Umweltkonzentrationen. Hier besteht noch Handlungsbedarf.
Leachiing tests - a useful tool for the environmental impact assessment of construction products?
(2018)
Construction products and waste materials used for construction can be in contact with the environment and may release potential harmful compounds. Information on the total content of these substances in the product is not sufficient to assess its envrionmental impact since it does not consider realistic exposure conditions.The impact of these compounds is often assessed by using the total content in the product. This estimation lacks realistic exposure conditions.
Concerning the pathway to soil and groundwater by contact with rain or seepage water leaching tests, which were developed and standardized by the European Committee for Standardization, are available. While for secondary construction products and waste this investigation of the leaching behaviour is standard procedure and is already part of regulation in Germany (draft ordinance on reuse of mineral waste) and within Europe (landfill directive) the release from primary construction products got in the focus more recently. Several monitoring studies found unexpected high concentrations of substances used as herbicides and fungicides in surface water and stormwater originating from urban areas. As some of these compounds are even banned for the use in agricultural applications in Europe alternative sources as roof materials and façade coatings exposed to rain were suggested. Further field and laboratory tests confirmed construction products as sources of these substances in water.
The aim of this presentation is to show exemplary results of existing leaching methods and underline the strength and weaknesses of the test system with selected examples from our work. We especially draw the attention to the research which is still needed to close the gap between the results of leaching experiments and the subsequent risk assessment of the products.
Construction products are in contact with water (e.g., rain, seepage water) during their service lifetime and may release potentially harmful compounds by leaching processes. Monitoring studies showed that compounds attributed to construction products are found in storm water and the receiving bodies of water and that the release of biocides in urban areas can be comparable to the input of pesticides from agricultural uses. Therefore, a prospective risk assessment of such products is necessary. Laboratory leaching tests have been developed by the Technical Committee CEN/TC 351 and are ready to use. One major task in the future will be the evaluation of the leaching test results, as concentrations found in laboratory experiments are not directly comparable to the field situations. Another Task will be the selection of compounds to be considered for construction products, which are often a complex mixture and contain additives, pigments, stabilization agents, etc. The formulations of the products may serve as a starting point, but total content is a poor predictor for leachability, and analysis of the eluates is necessary. In some cases, nontargeted approaches might be required to identify compounds in the eluates. In the identification process, plausibility checks referring to available information should be included. Ecotoxicological tests are a complementary method to test eluates, and the combined effects of all compounds—including Degradation products—are included. A bio test battery has been applied in a round robin test and was published in a guidance document. Published studies on the ecotoxicity of construction products show the tests’ suitability to distinguish between products with small and larger effects on the environment.
Ausgewählte Ergebnisse des UBA-Vorhabens "Beregnete Bauteile und Bauprodukte: Entwicklungen für Vergabegrundlagen für den Blauen Engel mit Hilfe von Auslaugtest" werden für organische und anorganische Analyten präsentiert. Ein Schwerpunkt ist den Einfluss der verschiedenen Schichten von WDVS-Systemen aufzuzeigen.
Brominated flame retardants have widely been used for more than 50 years and have been frequently detected in environmental samples as surface water and fish. Leaching from construction products was identified as one possible source. The use of substances as e.g. hexabromocyclododecane (HBCCD) was restricted recently due to increasing concern about negative impacts on the environment and human health caused by the persistent, bio accumulative and toxic properties. New polymeric brominated flame retardants have been developed to replace HBCCD in expanded polystyrene (XPS), which is used for insulation of buildings. It is assumed that the release from the polymer is much smaller in comparison to release of small molecules as HBCCD. The release from the polymer may include monomers or small fragments of different size. Thus, a sum parameter is needed. According to Schlummer et al. it is possible to detect brominated molecules using X-ray fluorescence spectroscopy by determination of brome content in XPS extracts. As only small brominated compounds can be extracted it also allows for the differentiation between the two classes of compounds. This method was applied to verify the presence of different kinds of flame retardants in XPS samples and to evaluate the leaching behavior.
The presentation gives an overview about the use of ecotoxicity testing in assessment of waste. Especially in cases with unknown composition this kind of test are useful. Recently, the assessment of the hazard property HP 14 "ecotoxicity" for the labelling of waste was published. The labelling procedure is explained in detail.