4 Material und Umwelt
Filtern
Dokumenttyp
Sprache
- Englisch (4)
Schlagworte
- Emission chamber (2)
- Antimicrobials (1)
- BODIPY (1)
- Biofilm (1)
- Comparison (1)
- Consumer article (1)
- Consumer products (1)
- EN 717-3 (1)
- Emission test chamber (1)
- Flask method (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Bacterial biofilms can pose a serious health risk to humans and are less susceptible
to antibiotics and disinfection than planktonic bacteria. Here, a novel method
for biofilm eradication based on antimicrobial photodynamic therapy utilizing
a nanoparticle in conjunction with a BODIPY derivative as photosensitizer was
developed. Reactive oxygen species are generated upon illumination with
visible light and lead to a strong, controllable and persistent eradication of
both planktonic bacteria and biofilms. One of the biggest challenges in biofilm
eradication is the penetration of the antimicrobial agent into the biofilm and
its matrix. A biocompatible hydrophilic nanoparticle was utilized as a delivery
system for the hydrophobic BODIPY dye and enabled its accumulation within the
biofilm. This key feature of delivering the antimicrobial agent to the site of action
where it is activated resulted in effective eradication of all tested biofilms. Here,
3 bacterial species that commonly form clinically relevant pathogenic biofilms
were selected: Escherichia coli, Staphylococcus aureus and Streptococcus
mutans. The development of this antimicrobial photodynamic therapy tool for
biofilm eradication takes a promising step towards new methods for the much
needed treatment of pathogenic biofilms.
Formaldehyde is considered as carcinogenic and is emitted from particleboards and plywood used in toy manufacturing. Currently, the flask method is frequently used in Europe for market surveillance purposes to assess formaldehyde release from toys, but its concordance to Levels measured in emission test chambers is poor. Surveillance laboratories are unable to afford laborious and expensive emission chamber testing to comply with a new amendment of the European Toy Directive; they need an alternative method that can provide reliable results. Therefore, the application of miniaturised emission test chambers was tested. Comparisons between a 1 m3 emission test chamber and 44 mL microchambers with two particleboards over 28 days and between a 24 L desiccator chamber and the microchambers with three puzzle samples over 10 days resulted in a correlation coefficient r2 of 0.834 for formaldehyde at steady state. The correlation between the results obtained in microchambers vs. flask showed a high variability over 10 samples (r2: 0.145),
thereby demonstrating the error-proneness of the flask method in comparison to methods carried out under ambient parameters. An exposure assessment was also performed for three toy puzzles: indoor formaldehyde concentrations caused by puzzles were not negligible (up to 8 µg/m3), especially when more conservative exposure scenarios were considered.
The ISO 16000 standard series provide guidelines for emission measurements of volatile organic compounds (VOCs) from building materials. However, polymer-based consumer products such as toys may also release harmful substances into indoor air. In such cases, the existing standard procedures are unsuitable for official control laboratories due to high costs for large emission testing chambers. This paper aims at developing and comparing alternative and more competitive methods for the emission testing of consumer products. The influence of the emission chamber size was investigated as smaller chambers are more suited to the common size of consumer products and may help to reduce the costs of testing. Comparison of the performance of a 203 l emission test chamber with two smaller chambers with the capacity of 24 l and 44 ml, respectively, was carried out by using a polyurethane reference material spiked with 14 VOCs during the course of 28 days. The area-specific emission rates obtained in the small chambers were always similar to those of the 203 l reference chamber after a few hours. This implies that smaller chambers can provide at least useful numbers on the extent of polymer-based consumer product emissions into indoor air, thereby supporting meaningful exposure assessments.
There is a need for an assessment of the emission properties of volatile organic compounds (VOCs) from consumer products. A method comparison was carried out to evaluate adapted and cost-effective procedures for such items. Smaller and automated emission chambers depicted similar kinetics compared to a 203 L standard chamber. Toy samples made of PVC (Polyvinyl chloride) emitted more VOCs compared to other tested polymeric products. The emissions from 2 selected samples were studied to allow an evaluation of the resulting room concentration and external exposure of a child. Obtained concentrations were not of concern.