4 Material und Umwelt
Filtern
Dokumenttyp
- Vortrag (4) (entfernen)
Referierte Publikation
- nein (4)
Schlagworte
- Additive manufacturing (1)
- Ammoniak (1)
- BODIPY dye (1)
- Fluorometric sensing (1)
- Gas sensing (1)
- Microbial (1)
- Mikrobiell (1)
- Multigassensorik (1)
- NDT (1)
- Particles (1)
Organisationseinheit der BAM
- 1.9 Chemische und optische Sensorik (4) (entfernen)
Eingeladener Vortrag
- nein (4)
Microbial contamination of fuels by fungi or bacteria poses risks such as corrosion and fuel system fouling, which can lead to critical problems in refineries and distribution systems and has a significant economic impact at every stage of the process. Many factors have been cited as being responsible for microbial growth, like the presence of water in the storage tanks. In fact, only 1 % water in a storage system is sufficient for the growth of microorganisms like bacteria or yeasts, as well as for the development of fungal biomass at the oil/water interface.
This work presents a rapid test for the accurate determination of genomic DNA from aqueous fuel extracts. The detection is based on the use of polystyrene-mesoporous silica core-shell particles onto which modified fluorescent molecular beacons are covalently grafted. These beacons contain in the hairpin loop a target sequence highly conserved in all bacteria, corresponding to a fragment of the 16S ribosomal RNA subunit. The designed single-stranded molecular beacon contained fluorescein as an internal indicator and a quencher in its proximity when not hybridized. Upon hybridization in presence of the target sequence, the indicator and the quencher are spatially separated, resulting in fluorescence enhancement. To perform the assay the developed particles were deposited on different glass fibre strips to obtain a portable and sensitive rapid test. The assays showed that the presence of genomic DNA extracts from bacteria down to 50–70 μg L–1 induced a fluorescence response. The optical read-out was adapted for on-site monitoring by fitting a 3D-printed case to a conventional smartphone, taking advantages of the sensitivity of the CMOS detector. Such embedded assembly enabled the detection of genomic DNA in aqueous extracts down to the mg L–1 range and represents an interesting step toward on-site monitoring of fuel contamination.
The project ProMoAM is presented. The goal of the project is to evaluate which NDT techniques or combination of techniques is suited for in-situ quality assurance in additive manufacturing of metals. To this end, also 3d-data fusion and visualization techniques are applied. Additional ex-situ NDT-techniques are used as references for defect detection and quantification. Feasability studies for NDT-techniques that are presently not applicable for in-situ use are performed as well.
The presentation gives a brief overview of the whole project and the different involved NDT-techniques.
Fluorometric sensing is a versatile approach for trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them as superior active component for the preparation of optical sensing devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents, illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications.
In the interdisciplinary project presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable. The dyes presented follow a “turn-on” fluorescence schematic, which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing. Further steps in the project include the assembly of instruments for test-atmosphere generation, the referencing of the sensor system, development and implementation of an optical setup, and the testing of the prototype device under laboratory conditions and in the field.
In this presentation, we give an overview over the recent developments on this topic in our groups. Highlights are hydrogen sulfide sensitive, BODIPY based transition metal complexes, which allow for a sensitive as well as selective detection of the toxic gas. In addition, we present a novel class of highly substituted BODIPY derivatives – pocket-BODIPYs – which are of a synthetically high versatility and can readily be modified to create pockets in the periphery of the molecule of defined geometries. This is illustrated on the successful encapsulation of benzene by a pocket-BODIPY derivative, confirmed by X-ray crystallographic analysis as well as by further spectroscopic and analytical methods.
Ammoniakemissionen in die Umwelt erfolgen insbesondere durch die Landwirtschaft (93,6 %), aber auch durch Verbrennungsprozesse in der die Abfallwirtschaft (2,3 %) und den Straßenverkehr (1,8 %). Dieser Stoff ist selbst in geringen Konzentrationen nicht nur eine Geruchsbelästigung, sondern auch eine Substanz mit ökologischer und klimatischer Relevanz.
Die Bestimmung von Ammoniak in relevanten Konzentrationen von kleiner 25 μg m-3 erfolgt im Allgemeinen über NH4+ als Analyten, spektralfotometrisch oder mit der Ionenchromatographie nach Überführung in die flüssige Phase. Wegen der niedrigen Konzentrationen an Ammoniak in der Außenluft wird meist eine gesammelte Probe verwendet oder die Bestimmung erfolgt nach einer aktiven, anreichernden Probenahme.
Die eigenen Arbeiten sollen dazu beitragen, die Ammoniak-Bestimmung in der Außenluft präziser, sowie schneller und kostengünstiger zu machen.
Die BAM prüfte daher kommerzielle elektrochemische und Metalloxid-basierte Sensoren, die für diesen Konzentrationsbereich aber nur bedingt geeignet sind. Deshalb wurden alternativ eigene Entwicklungen zum Nachweis von Ammoniak im Spurenbereich aufgenommen, wobei der Analyt über die Änderung der Fluoreszenz eines BODIPY-Farbstoffs bei 550 nm mittels eines portablen Fluoreszenz-Sensors direkt aus der Gasphase gemessen wird.
Zur Kalibrierung von Ammoniak-Sensoren und -Messgeräten steht ein stationäres System basierend auf der Mischung von zertifizierten Prüfgasen aus Druckflaschen mit kalibrierten Massendurchfluss-regler (MFC) zur Verfügung. Darüber hinaus erfolgt eine chemische Analyse der verwendeten Gasgemische mittels eines Massenspektrometers.
Für die Kalibrierung und Prüfung von Sensoren und Messgeräten vor Ort wurde ein mobiles Prüfsystem entwickelt. Die Generierung von Ammoniak-haltigen Gasen im Spurenbereich von 0,5 nmol/mol bis 500 nmol/mol erfolgt durch das Permeationsverfahren nach ISO 6145-10.
Für die Realisierung der Rückführbarkeit der Ammoniakbestimmung werden von den Nationalen Metrologischen Instituten sowie designierten Instituten Standards bereitgestellt und auch weiterentwickelt. Die primären metrologischen Standards beruhen auf SI-Einheiten und sind die Basis für eine Rückführbarkeit der Sensoren bzw. Analysengeräte.