4 Material und Umwelt
Filtern
Erscheinungsjahr
- 2019 (8) (entfernen)
Dokumenttyp
Referierte Publikation
- ja (8) (entfernen)
Schlagworte
- Leaching (4)
- Analytical methods (1)
- Biocides (1)
- Construction materials (1)
- Construction products regulation (CPR) (1)
- Deponie (1)
- Ecotoxicity (1)
- Fire-retardant paint (1)
- Forest soils (1)
- Geokunststoffe (1)
Organisationseinheit der BAM
- 4.3 Schadstofftransfer und Umwelttechnologien (8) (entfernen)
Draft standards for the determination of organic pollutants in the solid matter of environmental matrices such as sludge, treated biowaste and soil have been basically developed in the framework of the European standardization project HORIZONTAL. A research project financed by the German Federal Environment Agency was initiated to finalize some of these CEN standard drafts, since fully validated standard procedures are crucial for the evaluation of their reliability in the context of implementation in legislation on environmental health.
Approach: Appropriate test materials (< 2mm particle size) were prepared and homogenized from contaminated soils, sludge and treated biowaste containing polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), dioxins, furans and dioxin-like-PCB and served, along with reference solutions, as the basis for international interlaboratory comparisons. Performance data of three analytical standard procedures were obtained by the statistical evaluation of results received from 11 to 29 participants per test material.
Results: The overall variation coefficients of reproducibility (between-lab standard deviations) for the sum parameters were roughly between 10 and 35 %. The variation coefficients of repeatability (within-lab standard deviations) range between 3 % and 8 % and show no trend considering the substance groups or matrices.
The highest coefficients of reproducibility were found for the analysis of PAHs, which were between 26 and 35 %, depending on the matrix, whereas 7-17 % reproducibility was observed for toxicity equivalents (TEQ) comprising dioxins, furans and dl-PCB.
Conclusions: Overall, the results confirm that the procedures described in the Technical Specifications are fit for purpose for all three matrices and that the feasibility of the HORIZONTAL approach, to cover several matrices with one standard per analyte, was thereby proven.
An approach to achieve 'zero leakage' is discussed with respect to experience in Germany, where strict regulations for landfill lining and capping Systems have been developed and issued because of large environmental Problems related to landfills that accumulated in the 1970s and 1980s. Using a thick, high-quality high-density Polyethylene (HDPE) geomembrane (GM) that is installed free of residual waves and wrinkles in intimate contact with a compacted clay liner or geosynthetic clay liner of very low permeability, by a qualified, experienced, well-equipped and properly third-party-controlled installer, and which is protected by heavy protection layers designed with respect to the long-term performance of the GM may result in a liner or capping system of practically no leakage. This is demonstrated by analysing results of measurements obtained from permanently installed leak-detection Systems in combination with HDPE GMs. The survey was based on 32 German landfills with 1.276.500 m² of installed GMs.
In Denmark, increasing amounts of woody biomass are being used for the production of renewable energy, resulting in more wood ashes being generated. While these materials have been mainly landfilled, wood ashes may also be utilised for fertilizing and liming purposes on top of soils. Pre-treatments involving hardening or granulation may be carried out prior to soil application. In this study, two Danish wood ash samples were hardened and/or granulated. Lab-hardening induced rapid changes in the shape of the acid neutralisation capacity curve of the ashes. Up-flow column tests, assuming local equilibrium conditions, were employed to investigate the leaching from pre-treated ashes. Granules and loose ashes demonstrated similar leaching behaviours, indicating that similar geochemical processes were governing their leaching. In comparison with untreated fresh ashes, the hardened ashes demonstrated reduced leaching of Ca, Ba, Pb and Zn with concentration levels generally below or close to the analytical limits of quantification; to the contrary, the leaching of As, P, Sb, Si, V and Mg was enhanced in the hardened ashes. The release of alkalinity was reduced by hardening. In general, all granules were barely breakable by finger-pinching and they could withstand one month of continuous leaching, preserving their overall shape. The solubility of phosphorous in neutral ammonium citrate indicated that about 30–51% of the total P content in the ash samples was released, suggesting that the ashes could be potentially valuable as P-fertiliser if applied onto soil.
Column leaching tests are frequently used and accepted for investigation of release of hazardous substances from solid materials. Independent of differences due to the field of application or national regulations, column tests assume that local equilibrium is established in the experiment which facilitates transfer of results to field conditions. In the process of harmonization and standardization within Europe the question on the influence of flow rate and grain size distribution on the local equilibrium was raised. Thus, a set of experiments using two different masonry materials with varying grain size distribution and flow rate were conducted including stop/flow experiments. Results are compared to a numerical model which takes intraparticle pore diffusion-controlled release of Mo and V into the percolating water into account. Due to the relatively high intraparticle porosity of the materials (24–29%) data and model indicate that initially equilibrium-state conditions prevail followed by rapidly decreasing concentrations. The model fits data for Mo and V reasonably well; however, after the initial decline of concentrations (at L/S > 2) extended tailing is observed especially of elements occurring as oxides, which is not captured by the model.
Biocides are commonly applied to construction materials such as facade renders and paints in order to protect them from microbial spoilage. These renders and paints are exposed to weathering conditions, e.g., sunlight and rain. Pigments are interacting intensively with the spectrum of the incoming light; thus, an effect of paint pigments on phototransformation rates and reaction pathways of the biocides is hypothesized.
In this study, the phototransformation of four commonly used biocides (carbendazim, diuron, octylisothiazolinone (OIT) and terbutryn) in four different paint formulations differing solely in pigments (red and black iron oxides, white titanium dioxide, and one pigment-free formulation) were investigated. Paints surfaces were irradiated under controlled conditions. The results show that biocides degrade most rapidly in the pigment-free formulation. The degradation in the pigment-free formulation followed a first-order kinetic model with the respective photolysis rate constants: kp,Diuron=0.0090 h−1, kp,OIT=0.1205 h−1, kp,Terbutryn=0.0079 h−1.
Carbendazim concentrations did not change significantly. The degradation was considerably lower in the pigment-containing paints. The determination of several phototransformation products of terbutryn and octylisothiazolinone showed different transformation product ratios dependent on the pigment. Consequently, pigments not only reflect the incoming light, but also interact with the biocide photodegradation.
The environmental compatibility of reactive fire-retardant coatings (intumescent paints) was investigated by a combination of leaching and ecotoxicological tests. Three representative fire-retardant coating systems were tested using two leaching procedures: “Horizontal Dynamic Surface Leaching Test” (DSLT) and the “Intermittent Immersion Test” (IIT). All eluate fractions (8 for DSLT and 9 for IIT) were analyzed for pH, conductivity, concentration of total organic carbon and selected anions und cations. Additionally, a GC-MS screening of selected fractions was conducted for identification of organic compounds. Eluate fractions 1 + 2 and fraction 7 of the DSLT were analyzed in four ecotoxicological tests (algae, daphnia, fish egg, luminescent bacteria) and in one genotoxicity test (umu). Concentration of most analytes was rather low or below limit of detection for many eluates. Analytes detected in eluates of all three products are Zn, Ba, SO4(2−) and PO4(3−). Release patterns do not indicate a general trend: some compounds show maximum release in the first fractions while for others the maximum was observed in later test stages. Ecotoxic effects in eluates were found, which were higher in the eluate fraction 7 (maximum lowest ineffective dilution for luminescent bacteria (LIDL) 256) than in the eluate fraction 1 + 2 (maximum LIDL = 24). The sensitivity of the test systems was very different with highest effects for luminescent bacteria, followed by algae and daphnia and without effects in the fish egg test and umu test. A biotest battery for the comprehensive assessment is therefore advisable.
Leaching processes are responsible for the release of biocides from treated materials into the environment.
Adequate modeling of emission processes is required in order to predict emission values in the framework of the risk assessment of biocidal products intended for long-term service life. Regression approaches have been applied to data obtained from the long-term monitoring of biocide emissions in experiments involving semi-field conditions. Due to the complex interaction of different underlying mechanisms such as water and biocide diffusion and desorption, however, these attempts have proven to be of limited usefulness e at least, for the available biocide emission data. It seems that the behavior of the biocide emission curve depends to a considerable extent on whichever underlying mechanism is slowest at a given point in time, thus limiting the amount of biocide available for release. Building on results obtained in the past few years, the authors propose a criterion for determining which mechanism controls the leaching process at a given point in time based on the slope of the log-log emission curve. In addition, a first-order approximation of this slope value is presented which displays advantages both in terms of computability and interpretability. Finally, an algorithm for the determination of breakpoints in the slope of the log-log emission curve is presented for the demarcation of phases within which one mechanism acts as a limiting factor.
Vor 30 Jahren wurde die erste BAM-Zulassung für ein Geokunststoffprodukt in der Deponietechnik ausgestellt. Seither wurden immer wieder eigene wissenschaftliche Untersuchungen durchgeführt, neue Forschungsergebnisse herangezogen und die Prüftechnik weiterentwickelt, um die Eignung und Funktionsdauer von Kunststoffdichtungsbahnen, Schutzschichten, Kunststoff-Dränelementen, geotextilen Filtern oder Bewehrungsgittern beurteilen zu können. Einige dieser Entwicklungen werden hier diskutiert.