4 Material und Umwelt
Filtern
Dokumenttyp
- Vortrag (77)
- Zeitschriftenartikel (43)
- Posterpräsentation (24)
- Beitrag zu einem Tagungsband (17)
- Sonstiges (5)
- Forschungsbericht (4)
- Monografie (1)
- Buchkapitel (1)
- Forschungsdatensatz (1)
Schlagworte
- Nano (29)
- OECD (20)
- Nanomaterial (14)
- VOC (13)
- Bauprodukte (12)
- Emission (9)
- Prüfrichtlinie (9)
- Volatile organic compounds (8)
- Aerosol (7)
- BEMMA (7)
- Cascade impactor (7)
- ISO 16000-6 (7)
- Nanopartikel (7)
- EN 16516 (6)
- Geruch (6)
- TXRF (6)
- Emissionen (5)
- Museum (5)
- Nanomaterials (5)
- Nanoparticle (5)
- Reference material (5)
- Test guideline (5)
- Umweltsimulation (5)
- VVOCs (5)
- Analytical method (4)
- Architecture (4)
- Bundesoberbehörden (4)
- Chemical durability (4)
- Construction products (4)
- Corrosion (4)
- Emission test chamber (4)
- Formaldehyd (4)
- Gas chromatography (4)
- Guideline (4)
- Standardisation (4)
- Thermal desorption (4)
- UFP (4)
- Affinity chromatography (3)
- Air quality monitoring (3)
- Antibodies (3)
- ESEM (3)
- Electron microscopy (3)
- FFF-3D-Printer (3)
- Geruchsmessung (3)
- Glass (3)
- Low melting (3)
- Luftschadstoffe (3)
- Particle size distribution (3)
- Partikel (3)
- Perceived Intensity (3)
- Polyglycerol (3)
- Reference materials (3)
- Size (3)
- VOC-emission (3)
- Weathering (3)
- Additive Fertigung (2)
- Additive Manufacturing (2)
- Additive Manufacturing (AM) (2)
- Aerosol measurements (2)
- Aerosole (2)
- Air exchange rate (2)
- Ambient aerosols (2)
- Analytik (2)
- Behördenklausurtagung (2)
- Bewitterung (2)
- Biofilm (2)
- Biofilms (2)
- CO2 assisted impregnation (2)
- Capsules (2)
- Chamber test (2)
- Chemical analysis (2)
- Chemical characterization (2)
- Consumer products (2)
- Corona (2)
- Crystallization (2)
- DIN EN 16516 (2)
- Elektronisches Laborbuch (2)
- Element mass concentration (2)
- Emission chamber (2)
- Emission reference material (2)
- Emissions (2)
- Emissionskammer (2)
- Environmental simulation (2)
- European standard (2)
- FEM model (2)
- Fluorescence (2)
- Formaldehyde (2)
- Fume (2)
- GAeF (2)
- Glasmalfarben (2)
- Glutaraldehyde (2)
- Größenbestimmung (2)
- ICP-MS (2)
- Indoor air quality (2)
- Innenraum (2)
- Iron oxide nanoparticles (2)
- LA-ICP-MS (2)
- Laser Powder Bed Fusion (L-PBF) (2)
- Loading factor (2)
- Luft (2)
- MOF (2)
- Material emissions (2)
- Microbiome (2)
- Microplastics (2)
- Nano particle (2)
- Nanofasern (2)
- Nanomaterialien (2)
- Particle gas emission (2)
- Particle size (2)
- Particle size distributuion (2)
- Particles (2)
- Particulate emission (2)
- Plume (2)
- Pollutants (2)
- Prozessmonitoring (2)
- Purification (2)
- Radon (2)
- Reductive amination (2)
- Reference method (2)
- Round robin test (2)
- Sapphire (2)
- Schadstoffaustrag (2)
- Size distribution (2)
- Size resolved chemical composition (2)
- Spatter (2)
- Struvite (2)
- Test Guideline (2)
- Testguideline (2)
- Thermal extraction (2)
- Time resolved chemical composition (2)
- Total reflection X-ray spectroscopy (2)
- Ultrafine particles (2)
- VOC Emissionen (2)
- VOC-Emissionen (2)
- VVOC (2)
- Vitrinen (2)
- Wooden toys (2)
- 3D Printing (1)
- 3D printer (1)
- 3D printing (1)
- AEROMET II (1)
- AEROMET project (1)
- Accuracy (1)
- Additive manufacturing (1)
- Advanced Materials (1)
- Aerosol element alanysis (1)
- Aerosol element mass concentration (1)
- Aerosol gravimetry (1)
- Aerosol measurement instruments (1)
- Aerosol spectroscopy (1)
- Aerosolforschung (1)
- Aerosols (1)
- Aerosolsensor (1)
- Affinity extraction (1)
- Affinity support (1)
- AgBB Bewertung (1)
- Aging test (1)
- Aging tests (1)
- Air analysis (1)
- Air pollution (1)
- Air quality (1)
- Air sampling (1)
- Airborne Particles (1)
- Alkali zinc borate glass (1)
- Aluminium (1)
- Aluminum (1)
- Aluminum oxide (1)
- Ambient air (1)
- Ambient air pollution (1)
- Amino acid analysis (1)
- Ammoniak (1)
- Analytical chemistry (1)
- Analytische Methode (1)
- Anodization (1)
- Antibody purification (1)
- Aqueous synthesis (1)
- Architektur (1)
- Aromatic amino acid analysis AAAA (1)
- Aromatic amino acid analysis aaaa (1)
- BAM Data Store (1)
- BEMMA Bewertung (1)
- BFR (1)
- BMU (1)
- BODIPY dye (1)
- BSA (1)
- Bauproduktenverordnung (1)
- Beschichtung (1)
- Bewertung (1)
- Bewertungsverfahren (1)
- Bio-based insulation (1)
- Bio-weathering (1)
- Bioactive glass (1)
- Bioconjugation (1)
- Bioseparation (1)
- Biosphere (1)
- Black fungi (1)
- Blauer Engel (1)
- Blue Angel ecolabel (1)
- Bodenbelag (1)
- Bodenbeläge (1)
- Bovine serum albumin (1)
- Building product (1)
- Building products (1)
- Bürogeräte mit Druckfunktion (1)
- CCQM (1)
- COVID (1)
- CPC calibration (1)
- CRM (1)
- Calibration (1)
- Calibration transfer (1)
- Carrier (1)
- Cellulose ether (1)
- Cerium oxide (1)
- Chamber measurement (1)
- Characterisation (1)
- Characterization (1)
- Chemical composition (1)
- Chemische Beständigkeit (1)
- Climate responsive materials (1)
- Cobalt (1)
- Cognitive performance (1)
- Colored glasses (1)
- Comparison (1)
- Conservation (1)
- Construction Products (1)
- Construction product (1)
- Consumer article (1)
- Consumer articles (1)
- Core/shell nanoparticle (1)
- Corundum (1)
- Covid (1)
- Cross-sectioning (1)
- Cubical shape (1)
- DIN EN 717-1 (1)
- DMAS (1)
- Damage repair (1)
- Dendrimer (1)
- Diffusive sampling (1)
- Digitalisation (1)
- Digitalisierung (1)
- Dispay case (1)
- Dispergierung von Glaspartikeln (1)
- Dispersion of glass particle (1)
- Display case (1)
- Downstream processing (1)
- Druck (1)
- EDX Analysis (1)
- EN 717-1 (1)
- EN 717-3 (1)
- EU EMPIR (1)
- EU regulations (1)
- Earthen building materials (1)
- Effective uptake rate (1)
- Electronic Lab Notebook (ELN) (1)
- Electronic lab notebook (ELN) (1)
- Elektrolichtbogenofen (1)
- Element analysis (1)
- Elemental aerosol analysis (1)
- Elemental composition (1)
- Emerging Contaminants (1)
- Emission Test Chamber (1)
- Emission Testing (1)
- Emission chamber testing (1)
- Emission chambers (1)
- Emission reference materials (1)
- Emission test chamber procedure (1)
- Emission test method (1)
- Emissions of hazardous gases (1)
- Emissionsmessungen (1)
- Emissionsprüfkammer (1)
- Emissionsprüfung (1)
- Emisson testing (1)
- Enamel colors (1)
- Enamels (1)
- Environment (1)
- Environmental friendly (1)
- Exposure (1)
- Exposure risk (1)
- Extracellular pH (1)
- Extracellular polymeric substances (1)
- FFF-filament (1)
- FFF-printing (1)
- Faraday cup aerosol electrometer (1)
- Fatigue (1)
- Fiber (1)
- Fibre (1)
- Filament comparison (1)
- Flammschutzmittel (1)
- Flask method (1)
- Flexible shadow masks (1)
- Fluorometric sensing (1)
- Food (1)
- Forest fires (1)
- Forschungsdatenmanagement (1)
- Forschungsstrategie (1)
- Forsterite (1)
- Fungus (1)
- Gas analysis (1)
- Gas sensing (1)
- Gesundheit (1)
- Glas (1)
- Glasanalyse (1)
- Größe (1)
- Haze Samples (1)
- Heavy metal free (1)
- Historic buildings (1)
- Human plasma (1)
- Hyperbranched polymer (1)
- IAQ (1)
- IEQ (1)
- ISO REMCO (1)
- ISO/TC 229 Nanotechnologies (1)
- Idiopathic environmental intolerance (1)
- Igg (1)
- Immunoglobulins (1)
- Immunoprecipitation (1)
- In-situ Process Monitoring (1)
- In-situ analysis (1)
- Indoor Air Quality (1)
- Indoor Air: Adsorbent performance (1)
- Indoor Products (1)
- Indoor emission (1)
- Innenraumluft (1)
- Innenraumluftqualität (1)
- Innenraumluftqualtität (1)
- Inter-comparison (1)
- Inter-lab comparison (1)
- Intercomparison (1)
- Interlaboratory comparison (1)
- Iron oxide (1)
- Knock-out mutant (1)
- LCC (1)
- Lapis lazuli (1)
- Laser Printer (1)
- Laser printer emission (1)
- Layer-by-Layer (1)
- Linker (1)
- Low melting glasses (1)
- Low-tech approach (1)
- Luftgüte (1)
- Market surveillance (1)
- Mask fabrication (1)
- Material emissions testing (1)
- Mechanochemistry (1)
- Medieval glasses (1)
- Melanin Adhesion (1)
- Metallic silver precipitates (1)
- Metals (1)
- Methoden (1)
- Micro-XRF (1)
- Microchamber (1)
- Micropatterning (1)
- Migration (1)
- Mobile anodisation (1)
- Mobile application (1)
- Model aerosols (1)
- Molecular Organic Frameworks (1)
- Monoterpene (1)
- Multigassensorik (1)
- Multiple Displacement Amplification (1)
- Multiple chemical sensitivity (1)
- Museumsvitrine (1)
- Museumsvitrinen (1)
- NDT (1)
- NFDI (1)
- NGS (1)
- Nano CRM (1)
- Nano@BAM (1)
- NanoPlattform (1)
- Nanocarrier (1)
- Nanoparticles (1)
- Nanoplattform (1)
- Nanopowder (1)
- Nanosensor (1)
- Nanotechnologie (1)
- Neuartige Materialien (1)
- Nickel (1)
- Niedrig schmelzend (1)
- Non-destructive Materials (1)
- Nonspecific binding (NSB) (1)
- Novel sample preparation techniques (1)
- Oddy test (1)
- Odour (1)
- Office machines (1)
- Olivine (1)
- OpenBIS (1)
- Operating Procedure (1)
- Optical properties (1)
- Optische Tomografie (1)
- PBFSM (1)
- PGAA (1)
- PIXE (1)
- PM monitors (1)
- PP (1)
- PS (1)
- Particle (1)
- Particle Size (1)
- Particle emission (1)
- Particulate emissions (1)
- Partikeldurchmesser (1)
- Parylene C (1)
- Passive sampling (1)
- Periodate oxidation (1)
- Perowskit (1)
- Phase separation (1)
- Phosphates (1)
- Phosphonic acids (1)
- Phosphorous recovery (1)
- Phototrophic bacteria (1)
- Pigment analyses (1)
- Pilot comparison (1)
- Plastic biofilm (1)
- Plastic pollution (1)
- Polyelektrolyt (1)
- Polymer (1)
- Polypropylen (1)
- Polystyrol (1)
- Printing (1)
- ProMoAM (1)
- Process development (1)
- Process monitoring (1)
- Proficiency testing (1)
- Protein (1)
- Protein a (1)
- Protein hydrolysis (1)
- Protein immobilization (1)
- Protein quantification (1)
- Proton conductivity (1)
- Provenance studies (1)
- Prüfkammer (1)
- Prürfrichtlinie (1)
- QA/QC (1)
- Quality assurance (1)
- Quantum dot (1)
- REACH (1)
- RFA (1)
- Radon exhalation (1)
- Recovery rate (1)
- Recycling (1)
- Reduktionsprozess (1)
- Reference data (1)
- Reference nanoparticles (1)
- Reference procedures (1)
- Reference samples (1)
- Release kinetics (1)
- Research Data Infrastructure (1)
- Research Data Management (1)
- Research data management (1)
- Ringversuch (1)
- Robustness validation (1)
- Rround robin test (1)
- SARS (1)
- SAXS (1)
- SDS-PAGE (1)
- SMPS (1)
- SOP (1)
- Safety (1)
- Sample preparation (1)
- Schadgase (1)
- Schutzverglasung (1)
- Selective quantification (1)
- Self-assembled monolayer (SAM) (1)
- Self-assembled monolayers (SAM) (1)
- Semivolatile organic compounds (1)
- Sensor (1)
- Silver diffusion (1)
- Sintering (1)
- Small angle x-ray scattering (1)
- Solid phase (1)
- Solid-phase extraction (SPE) (1)
- Solvents (1)
- Spectroscopy (1)
- Spielzeug (1)
- Stained glasses (1)
- Standardarbeitsanweisungen (1)
- Subjective complaints (1)
- Surface chemistry (1)
- Sustainability (1)
- Synthesis (1)
- TEM (1)
- TXRF ambient air aerosol chemical analysis aerosol element composition (1)
- Tantal (1)
- Targeting, Nanoparticles (1)
- Test method (1)
- Thermal Desorption (1)
- Thermal Extraction (1)
- Thermal properties (1)
- Thermografie (1)
- Thermoplastic filaments (1)
- Transition metals (1)
- Transmission electron microscopy (1)
- Tyrosine (1)
- UV absorption (1)
- UV protection (1)
- Umweltmessung (1)
- Up-cycling (1)
- Uptake rate (1)
- VAMAS (1)
- VOC Emission (1)
- VOC emission (1)
- VOC transfer standards (1)
- VOC-Emission (1)
- Vitrine (1)
- Volatile organic compound (1)
- Volatile organic compounds (VOC) (1)
- WKI flask method (1)
- Weathering tests (1)
- Workflows (1)
- X-Ray analysis (1)
- XRF (1)
- ZIF (1)
- ZIF-8 (1)
- Zeolithe (1)
- Zinc oxide (1)
- natural ventilation (1)
- openBIS (1)
- pH (1)
- pH sensor (1)
- pHe (1)
- Äquivalenzdurchmesser (1)
Organisationseinheit der BAM
- 4.2 Material-Mikrobiom Wechselwirkungen (173) (entfernen)
Paper des Monats
- ja (3)
EN 16516 sets the test method and requirements for the determination of emissions of Volatile Organic Compounds (VOCs) from building materials into indoor air. To address the quality control requirements for the class of semi-VOCs (SVOCs), VSL developed gaseous reference materials. A novel home-made dynamic gas mixture preparation system, operating according to ISO 6145-4 (continuous injection method), has recently been developed and validated. Thanks to the stable temperature control up to 100 oC, the system can prevent condensation of the SVOCs in air at indoor air concentration levels. The in-situ obtained SVOC gas standards can be sampled in sorbent tubes to obtain SVOC transfer standards. A study was performed to determine the optimal sorbent material and storage conditions. This study will be presented together with the results of the 2018 Round Robin test for emission test chamber measurements organised by BAM. Using the novel system, VSL prepared transfer standards with known amounts of VOCs and SVOCs for participants to evaluate their analytical performance.
The chemical emissions from products are tested by means of emission test chambers under defined conditions (climate, loading, air change rate). The standard method for the determination of volatile organic compounds (VOC) is the sampling onto Tenax-tubes followed by thermal desorption (TDS) and gas chromatography-mass spectrometry (GC-MS) analysis. The EU-LCI list includes some very volatile organic compounds (VVOC) and some VOC for which there are limitations when using the standard method. For VVOC additional sampling is required using stronger absorbers like Carbotrap or multi-bed adsorption tubes. The analysis of VVOC also requires a different GC oven program and a different column for the separation. For the determination of formaldehyde and other low boiling aldehydes (e.g. acetaldehyde, acetone, propanal, propenal) DNPH-cartridges are used which are extracted with acetonitrile followed by liquid chromatography (HPLC-UV) analysis. The derivatisation of propenal and other unsaturated aldehydes (e.g. 2-butenal) with DNPH might lead to lower findings due to incomplete derivatization and forming of by-products. For a better quantification of acetic acid the use of ion chromatography (IC) is recommended because the analysis of acetic acid with the standard method (TDS) leads to lower findings due to break through during sampling. The use of ion chromatography for the analysis of organic acids requires a third sampling technique. The acids are adsorbed onto silica-gel and extracted with water.
Laser Powder Bed Fusion (L-PBF) is a promising additive manufacturing (AM) technology for metal part production especially for complex and lightweight structures or functional designs. In L PBF processes several by-products including welding plume and its condensates, spatter and ejected powder are generated during laser exposure. Investigations of micro- and nano-sized by-products have received little attention in literature. This study focuses on the analysis of particle emissions in L PBF of 316L stainless steel using a scattered light aerosol spectrometer and a fast mobility particle sizer spectrometer during the process which allows for in-situ analysis of particle sizes in the range of 6 nm to 100 µm. A distinct correlation of emission signals to part position can be revealed. In addition, a significant influence of laser scanning vector directions on emission signals is presented. Furthermore, differing powder layer thicknesses can be recognised by deviations in emission signals.
Laser Powder Bed Fusion (L-PBF) is a promising additive manufacturing (AM) technology for metal part production especially for complex and lightweight structures or functional designs. In L PBF processes several by-products including welding plume and its condensates, spatter and ejected powder are generated during laser exposure. Investigations of micro- and nano-sized by-products have received little attention in literature. This study focuses on the analysis of particle emissions in L PBF of 316L stainless steel using a scattered light aerosol spectrometer and a fast mobility particle sizer spectrometer during the process which allows for in-situ analysis of particle sizes in the range of 6 nm to 100 µm. A distinct correlation of emission signals to part position can be revealed. In addition, a significant influence of laser scanning vector directions on emission signals is presented. Furthermore, differing powder layer thicknesses can be recognised by deviations in emission signals.
Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat.
Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits¬anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor.
Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012.
The ISO 16000 standard series provide guidelines for emission measurements of volatile organic compounds (VOCs) from building materials. However, polymer-based consumer products such as toys may also release harmful substances into indoor air. In such cases, the existing standard procedures are unsuitable for official control laboratories due to high costs for large emission testing chambers. This paper aims at developing and comparing alternative and more competitive methods for the emission testing of consumer products. The influence of the emission chamber size was investigated as smaller chambers are more suited to the common size of consumer products and may help to reduce the costs of testing. Comparison of the performance of a 203 l emission test chamber with two smaller chambers with the capacity of 24 l and 44 ml, respectively, was carried out by using a polyurethane reference material spiked with 14 VOCs during the course of 28 days. The area-specific emission rates obtained in the small chambers were always similar to those of the 203 l reference chamber after a few hours. This implies that smaller chambers can provide at least useful numbers on the extent of polymer-based consumer product emissions into indoor air, thereby supporting meaningful exposure assessments.
Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat.
Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits-anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor.
Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012.
A reliable analysis of aerosol particle is curial for enforcing EU air quality regulations to protect human health, and for research on climate change effects [1]. Although metrics such as PM10 and PM2.5 are currently in use, the level of uncertainty of aerosol metrics is too high and the traceability is insufficient. Within the AEROMET project [2] procedures are developed aiming at reducing the uncertainties of particle mass, size, and number concentration measurements including the characterization of regulated components in airborne particles. Here, we present an approach how to improve the uncertainties of the particle mass by mobile total reflection x-ray fluorescence (TXRF) analysis. The combination of TXRF and aerosols sampling techniques supported by reference-free synchrotron radiation-based XRF enables a quantitative real-time analysis of particle mass. During in-field campaigns, the procedure was tested, monitoring the size dependent mass concentrations of specific elements in ambient aerosols under dynamic conditions. This approach allows a direct time and size-resolved analysis without laborious digestion steps and a reduced risk of contamination.
Aerosol particles were sampled in a 13-stage DLPI impactor on acrylic discs. TXRF analysis was performed on-site with the transportable spectrometer S2 PICOFOX (Bruker Nano GmbH). The TXRF quantification was based on internal standardization. At moderate air pollution levels (PM10 20 µg/m³) sampling times of less than 2 hours were enough to detect elements in different particle size bins. The on-site approach and the high sensitivity of TXRF enables the observation of rather quick changes in the quantity and distribution of elements in an ambient aerosol on the day of sampling. The analysis of the morning and afternoon sampling shifts reveals the occurrence of the elements Fe, Ca and Si in different size bins as well as their temporal change in respective mass concentrations over the day while the distributions of several other elements remain unchanged.
Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren.
Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden.
Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. Diese Entwicklungen werden hier aufgezeigt.
The objective of this study is to find out, to what extent the geochemical characteristics of lapis lazuli can be utilized in respect to its provenance. A wide range of variables is taken into consideration depending on the quantity of samples analysed from a specific geological region and the methods applied. In order to provide evidence, a multi-technique analytical approach using µXRF, ESEM, PGAA and PIXE is applied to samples from the most famous deposits of lapis lazuli. Special elements determined as fingerprints are compared in relation to the forming conditions obvious in textural features. The results and statistical output allow a differentiation that enables an optimized local classification of the blue stone. An absolute requirement for all geo-tracing performed on blue colored cultural objects of unknown provenance is awareness of the limits of analysis. The possible sources of lapis lazuli are tested by analysing the blue pigment used as paint on murals and ink on manuscripts from the Silk Road.
Today glass is broadly used in modern architecture. For indoor applications it is possible to produce decorated glass by using enamel colours and glass painting techniques without any problems. However, this is more limited for applications out of doors. Humidity and environmental pollution attack the surface of the coating and can damage it. There are only a few colours on the market which are resistant towards acids and bases until now. Additionally, most of those colours are opaque. To extend the colour palette, chemically resistant low melting coloured glasses are being developed which are transparent and intensively toned even in thin coating thicknesses. To achieve such an ambitious aim, many parameters have to combine and act in a complex manner. New compositions of lead borosilicate, zinc borosilicate and lead-zinc borosilicate glasses were produced and milled as powder. The thermal properties as well as the environmental stability were analysed. The influence of PbO and ZnO on the thermal properties and the environmental stability were investigated. Evaluation of the fusing results shows that the production and mixture of transparent vitreous enamels for the exterior side of glasses is possible. The tests made it clear that the original materials for making the vitreous enamels must be excellently ground and prepared to achieve a satisfactory result. The method to produce durable vitreous enamels for exterior application also seems to allow the production of glass colours.
Menschen, die in der gemäßigten Klimazone leben, verbringen bis zu 90% ihres Lebens in Innenräumen. Deshalb hat das Innenraumklima eine sehr große Bedeutung für deren Wohlergehen, Gesundheit und Leistungsfähigkeit. In Deutschland wird ca. 40% der eingesetzten Primärenergie für das Heizen, Kühlen und Klimatisieren der Innenräume verwendet.
Das Forschungsvorhaben hat eine Laufzeit vom Oktober 2013 bis März 2017. Es wird in Kooperation mit der Bundesanstalt für Materialforschung und –prüfung (BAM) und der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) durchgeführt. Die HTW Berlin koordiniert das Projekt. Die Rheinisch-Westfälische Technische Hochschule Aachen (RWTH) wird teilweise über einen Auftrag in das Projekt integriert.
Ziel des Projektes ist es Baustoffe auf ihre Geruchsemissionen zu untersuchen, um Bauprodukte mit niedrigen Emissionen und Gerüchen identifizieren zu können. Den Verbraucherinnen und Verbrauchern wird somit die Möglichkeit gegeben emissions- und geruchsarme Baustoffe zu wählen.
Die Aufgabenstellung des Projektes ist nachfolgend aufgeführt:
Arbeitspaket 1: Geruchsmessung bei Produkten mit dem Blauen Engel (siehe Kapitel 4 und 5);
Arbeitspaket 2: Untersuchung von Vergleichsmaßstäben (siehe Kapitel 6);
Arbeitspaket 3: Untersuchung der Linearität der Acetonskala (siehe Kapitel 7);
Arbeitspaket 4: Erstellung einer Produktdatenbank (siehe Kapitel 8).
Die Geruchsuntersuchung ist in den Vergabekriterien für den „Blauen Engel“ für textile Bodenbeläge (RAL UZ-128) eingebunden worden. Aus den weiteren Untersuchungen sind für die Normung wichtige Erkenntnisse erarbeitet worden.
Textile floor coverings are often used in offices and residential buildings. Large areas like meeting rooms, cinemas, theaters and hotels are often equipped with such coverings. They contribute to the comfort of the users as they provide high pedaling comfort and sound absorption. The weakness of these building materials is due to the odor emission that is released from the floor covering, which affects the comfort of the users. A bad air quality and the resulting dissatisfaction can lead to lower employee productivity. The research project of the Hochschule für Technik und Wirtschaft Berlin (HTW-Berlin) is promoted by the German Environment Agency (UBA). The project has the following title: Low-emission and low-odor building products for energy-efficient buildings - Development of requirements and concepts for the Blue Angel from a climate protection perspective; investigates the emission and odor behavior of textile floor coverings (Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude - Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht; untersucht das Emissions- und Geruchsverhalten textiler Bodenbeläge).
The project ProMoAM is presented. The goal of the project is to evaluate which NDT techniques or combination of techniques is suited for in-situ quality assurance in additive manufacturing of metals. To this end, also 3d-data fusion and visualization techniques are applied. Additional ex-situ NDT-techniques are used as references for defect detection and quantification. Feasability studies for NDT-techniques that are presently not applicable for in-situ use are performed as well.
The presentation gives a brief overview of the whole project and the different involved NDT-techniques.
Die von der BAM eingekauften Holzwerkstoffplatten (Verlegespanplatten, OSB, Multiplexplatten) verschiedener Hersteller zeigten teilweise hohe Formaldehyd-emissionen unter den Prüfbedingungen nach EN 16516, eine Spanplatte hielt den Grenzwert von 0,1 ppm selbst bei Prüfung nach DIN EN 717-1 nicht ein, dürfte also in Deutschland gar nicht in den Verkauf gelangen.
Holzwerkstoffe, die unter den Prüfbedingungen der DIN EN 717-1 die Formaldehydklasse E1 einhalten, können insbesondere bei großflächigem Einsatz im Innenraum zu Überschreitungen des Richtwertes für die Innenraumluft führen. Zusätzlich zur Anpassung des Luftwechsels ist auch der Parameter Beladung bei einer Überarbeitung der Norm anzupassen. In der DIN EN 16516 werden produktspezifische (am Einsatz der Produkte orientierte) Beladungsfaktoren vorgegeben. Für den Einsatz von Holzwerkstoffplatten ergäben sich Beladungen von 0,4 (Boden oder Decke), 1,0 (Wände), 1,4 (Wände plus Boden oder Decke) und 1,8 m²/m³ (Wände, Boden und Decke). Um die realen Bedingungen in modernen Gebäuden abzubilden, ist deshalb eine Beladung von 1,8 m²/m³ für die Prüfkammermessung erforderlich. Hierbei ist darauf hinzuweisen, dass für die Beladung im Referenzraum Möbel nicht berücksichtigt wurden.
Damit soll sichergestellt werden, dass die Einhaltung des Schutzniveaus bei realen Innenraumbedingungen auch unter den Randbedingungen eines niedrigen Luftwechsels sowie bei sommerlichen Bedingungen und heutigem Lüftungsverhalten der Menschen soweit wie möglich gewährleistet ist.
The church of Koszewko (Poland) is a brick building edified in the 15th century built on cobblestone foundations. There are five windows in the sanctuary. Three of them enclose heraldic panels from the Küssow’s family from the 15th century which are surrounded with Goethe glass from the 18th century to complete the windows. The colored heraldic panels are strongly damaged and corroded with massive paint layer losses, glass- and leadbreakages. Those medieval glass fragments have been shortly discovered and are of particular interest for Poland since only few medieval glazing have been conserved.
The damages as well as the glass compositions have been investigated with ESEM/EDX. Two categories of medieval glass compositions have been identified. The blue glass is particularly sensible to corrosion because of his high content in K2O. The colorless and the red glass samples belong to a stable glass type. Due to the thickness of the gel layer, it is easy to see that the degradation is strongly proceeded. The protection of those medieval stained-glass panels is absolute necessary.
The medieval panels have been restored and surrounded from a copper frame. Then they have been fixed on the wood frame in the church. The exterior glazing has been closed with a panel of Goethe glass. The gap between the Goethe- and the medieval glass is about 3 cm. The Goethe glass panel has been stabilized with a film based on polyester to protect the medieval glasses against any damages. In this way, a low cost protective glazing has been installed for a long-term conservation of each medieval stained-glass panels. The climate measurements over the period of one year on the restored windows are in process. The temperature and the relative humidity are recorded in the church interior, in the gap between the original and the Goethe glass and outdoors.
Quality Improvement of VOC chamber emission tests observed for 10 years with round robin tests
(2018)
In Europe, the Construction Products Regulation (CPR, 2011/305/EU) sets basic requirements (BR) on how construction works must be designed and built. BR 3 “hygiene, health and the environment” states low emissions of toxic gases, Volatile Organic Compounds (VOCVOCs), particles, etc. from building materials. Meanwhile, a worldwide network of professional Commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established.
Therefore, comparability of test results must be ensured. The participation in Round Robin Tests (RRTRRTs) is a means to prove a laboratory’s proficiency. Since 2006 BAM offers such proficiency test for emission chamber test every two years.
Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. BAM used different materials over the years. Currently, the best suited reference material is a cured lacquer surface which contained several VOCs added to the liquid lacquer system. The round robin tests 2014, 2016 and 2018 were conducted with such a system.
Compounds like Styrene or n-Alkanes like Decane or Tridecane were tested in many of the proficiency test operated by BAM. Up to now the relative standard deviation of these compounds decrease continuously. Starting with values about 30 % in 2008 we reached values for the mentioned compounds 15 to 20 % now. But even for more polar compounds improved results were received.
Over the years the results of a large group of laboratories detected many compounds with much higher accuracy than at the beginning. So, the comparability between results of different laboratories becomes much better.
Es lässt sich feststellen, dass eine Vielzahl unterschiedlicher flüchtiger organischer Verbindungen aus Bauprodukten freigesetzt werden kann. Hierbei gibt es in den meisten Bauproduktgruppen sowohl emissionsarme als auch emissionsreiche Produkte.
Manche Verbindungen sind produktgruppenspezifisch; so werden beispielsweise Siloxane aus Silikondichtmassen freigesetzt, andere Verbindungen sind eher unspezifisch wie Formaldehyd und Essigsäure, die aber in unterschiedlichen Konzentrationen aus einer Vielzahl von Produkten abgegeben werden und zu den am häufigsten emittierten Verbindungen zählen.
Es ist darauf hinzuweisen, dass VOC-Analytik und Gerüche im Allgemeinen keinen Zusammenhang zeigen.
Gerade bei modernen, dichten Bauten mit geringem natürlichem Luftwechsel sind hohe Schadstoffkonzentrationen zu erwarten, wenn nicht emissionsarme Materialien und Produkte zum Einsatz kommen.