The release of hazardous compounds from construction products can harm human health and the environment. To improve the sustainability of construction materials, the leaching of substances from construction products and their potential environmental impact should be assessed. Twenty-seven construction products from different product groups were examined with a combination of standardized leaching tests (dynamic surface leaching test and percolation test) and biotests (algae, daphnia, fish egg, luminescent bacteria, umu and Ames fluctuation tests). To identify the released substances, extensive qualitative and quantitative chemical analyses were performed, including gas chromatographic and liquid chromatographic screening techniques.
Results: Many of the tested eluates caused signifcant ecotoxic efects. Particularly high ecotoxicities were observed for grouts (lowest ineffective dilution (LID) up to 16384) and cork granules (LID up to 24578). The results of ecotoxicity tests allow the prioritization of the eluates that should be subjected to detailed chemical analyses. Organic screening by different methods and ranking the identifed substances based on recorded hazard classification is a suitable approach to identify the relevant toxic substances.
Conclusions: Determining the ecotoxicity of eluates from construction products records the summary effect of all leachable substances. This instrument is especially useful for construction products of complex and largely unknown composition. The ecotoxicological and the chemical–analytical approach complement each other in an ideal way to characterize the potential hazard of eluates from construction products and to identify the environmentally hazardous components in these eluates. Our results confirm that the proposed harmonized methods for testing eluate toxicity are an adequate and applicable procedure to move toward a more sustainable way of building and to reduce toxic effects of construction products in their use phase in the environment.
The environmental compatibility of reactive fire-retardant coatings (intumescent paints) was investigated by a combination of leaching and ecotoxicological tests. Three representative fire-retardant coating systems were tested using two leaching procedures: “Horizontal Dynamic Surface Leaching Test” (DSLT) and the “Intermittent Immersion Test” (IIT). All eluate fractions (8 for DSLT and 9 for IIT) were analyzed for pH, conductivity, concentration of total organic carbon and selected anions und cations. Additionally, a GC-MS screening of selected fractions was conducted for identification of organic compounds. Eluate fractions 1 + 2 and fraction 7 of the DSLT were analyzed in four ecotoxicological tests (algae, daphnia, fish egg, luminescent bacteria) and in one genotoxicity test (umu). Concentration of most analytes was rather low or below limit of detection for many eluates. Analytes detected in eluates of all three products are Zn, Ba, SO4(2−) and PO4(3−). Release patterns do not indicate a general trend: some compounds show maximum release in the first fractions while for others the maximum was observed in later test stages. Ecotoxic effects in eluates were found, which were higher in the eluate fraction 7 (maximum lowest ineffective dilution for luminescent bacteria (LIDL) 256) than in the eluate fraction 1 + 2 (maximum LIDL = 24). The sensitivity of the test systems was very different with highest effects for luminescent bacteria, followed by algae and daphnia and without effects in the fish egg test and umu test. A biotest battery for the comprehensive assessment is therefore advisable.