4 Material und Umwelt
Filtern
Dokumenttyp
Schlagworte
- Leaching (30) (entfernen)
Organisationseinheit der BAM
- 4 Material und Umwelt (30) (entfernen)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (9)
Potential use of incineration bottom ash in construction – Evaluation of environmental impact
(2018)
Around 5 million tonnes of MSWI bottom ash (BA) are generated per year in Germany. The incineration itself serves for metals as a concentrating and cleaning process. However, due to the almost exclusive wet extraction out of the furnace chamber the various metals are integrated in a heterogeneous and instable matrix. The metal recovery is therefore still a challenge relating the recovery rate and the purity, respectively. With state of the art treatment trains in Germany around 7.7% of ferrous metals and 1.3% of non-ferrous metals can be recovered out of MSWI BA. Large quantities of the mineral fraction are reused for sub-base material in road construction. A three month ageing period has been established as the common practice of further treatment of bottom ash before reuse applications. In the course of this aging the pH value of bottom ash decreases and contaminants are immobilized by processes like carbonation, hydration and oxidation. In particular leaching of heavy metals may be reduced to environmentally acceptable levels. However, the aging results in fixing of other valuable resources such as metals. Two laboratory scale lysimeters (30 cm in diameter) are being operated for more than three years aiming at the investigation of the long-term leaching behavior of a 0.25/45 mm mineral material obtained by treatment of MSWI bottom ash directly after incineration by a wet processing technology. Artificial rainwater is used as leachant (pH ≈ 6, ingredients NO32-, Cl-, SO42-, Na+, K+, Ca2+, Mg2+). The lysimeters are irrigated related to an average annual precipitation rate of 600 mm/a leading to a liquid to solid ratio (L/S) of about 0.7 per year of operation. Lysimeter tests are more adequate to simulate field scenarios and long-term leaching behavior in contrast to laboratory column tests particularly due to the unsaturated conditions and realistic contact time with the leachant.
In comparison to the leaching of bottom ash (aged for 3 month and non-treated) in column tests the chloride and sulfate leaching in the lysimeters was reduced as a consequence of the previous wet processing. The sulfate release kept almost constant limited by CaSO4 solubility up to an L/S of about 0.7 l/kg. The chloride concentrations dropped quickly, starting from 7300 mg/l, and are now at an almost constant level of 50 mg/l which is significantly above the chloride concentration in the leachant. After an initial decrease of the pH from about 10.4 to 8 at L/S of 0.2 l/kg, the pH increased again and leveled out around 9.8 up to L/S 2.2 l/kg. At an L/S of about 2.5 l/kg now, Cr, Cu are still released. The Cu and Cr concentrations in the leachates were about 760 µg/l and 90 µg/l respectively at the beginning. For both metals the concentration decreased to about 35 µg/l now. The Mo concentrations dropped steadily from 1300 to 250 µg/l, whereas V and Sb concentrations increased in the course of the tests. Fe and Mn are not detectable anymore. More results of this experimental study will be presented and discussed with a special focus on elements forming oxyanions.
The release of hazardous compounds from construction products can harm human health and the environment. To improve the sustainability of construction materials, the leaching of substances from construction products and their potential environmental impact should be assessed. Twenty-seven construction products from different product groups were examined with a combination of standardized leaching tests (dynamic surface leaching test and percolation test) and biotests (algae, daphnia, fish egg, luminescent bacteria, umu and Ames fluctuation tests). To identify the released substances, extensive qualitative and quantitative chemical analyses were performed, including gas chromatographic and liquid chromatographic screening techniques.
Results: Many of the tested eluates caused signifcant ecotoxic efects. Particularly high ecotoxicities were observed for grouts (lowest ineffective dilution (LID) up to 16384) and cork granules (LID up to 24578). The results of ecotoxicity tests allow the prioritization of the eluates that should be subjected to detailed chemical analyses. Organic screening by different methods and ranking the identifed substances based on recorded hazard classification is a suitable approach to identify the relevant toxic substances.
Conclusions: Determining the ecotoxicity of eluates from construction products records the summary effect of all leachable substances. This instrument is especially useful for construction products of complex and largely unknown composition. The ecotoxicological and the chemical–analytical approach complement each other in an ideal way to characterize the potential hazard of eluates from construction products and to identify the environmentally hazardous components in these eluates. Our results confirm that the proposed harmonized methods for testing eluate toxicity are an adequate and applicable procedure to move toward a more sustainable way of building and to reduce toxic effects of construction products in their use phase in the environment.
The environmental compatibility of reactive fire-retardant coatings (intumescent paints) was investigated by a combination of leaching and ecotoxicological tests. Three representative fire-retardant coating systems were tested using two leaching procedures: “Horizontal Dynamic Surface Leaching Test” (DSLT) and the “Intermittent Immersion Test” (IIT). All eluate fractions (8 for DSLT and 9 for IIT) were analyzed for pH, conductivity, concentration of total organic carbon and selected anions und cations. Additionally, a GC-MS screening of selected fractions was conducted for identification of organic compounds. Eluate fractions 1 + 2 and fraction 7 of the DSLT were analyzed in four ecotoxicological tests (algae, daphnia, fish egg, luminescent bacteria) and in one genotoxicity test (umu). Concentration of most analytes was rather low or below limit of detection for many eluates. Analytes detected in eluates of all three products are Zn, Ba, SO4(2−) and PO4(3−). Release patterns do not indicate a general trend: some compounds show maximum release in the first fractions while for others the maximum was observed in later test stages. Ecotoxic effects in eluates were found, which were higher in the eluate fraction 7 (maximum lowest ineffective dilution for luminescent bacteria (LIDL) 256) than in the eluate fraction 1 + 2 (maximum LIDL = 24). The sensitivity of the test systems was very different with highest effects for luminescent bacteria, followed by algae and daphnia and without effects in the fish egg test and umu test. A biotest battery for the comprehensive assessment is therefore advisable.
The leaching behavior of scandium (Sc) from bauxite residues can differ significantly when residues of different geological backgrounds are compared. The mineralogy of the source rock and the physicochemical environment during bauxitization affect the association of Sc in the bauxite i.e., how Sc is distributed amongst different mineral phases and whether it is incorporated in and/or adsorbed onto those phases. The Sc association in the bauxite is in turn crucial for the resulting Sc association in the bauxite residue. In this study systematic leaching experiments were performed on three different bauxite residues using a statistical design of experiments approach. The three bauxite residues compared originated from processing of lateritic and karstic bauxites from
Germany, Hungary, and Russia. The recovery of Sc and Fe was determined by ICP-OES measurements. Mineralogical changes were analyzed by X-ray-diffraction and subsequent Rietveld refinement. The effects of various parameters including temperature, acid type, acid concentration, liquid-to-solid ratio and residence time were studied. A response surface model was calculated for the selected case of citric acid leaching of Hungarian bauxite residue. The investigations showed that the type of bauxite residue has a strong influence. The easily leachable fraction of Sc can vary considerably between the types, reaching ~20–25% in German Bauxite residue and ~50% in Russian bauxite residue. Mineralogical investigations revealed that a major part of this fraction was released from secondary phases such as cancrinite and katoite formed during Bayer processing of the bauxite.
The effect of temperature on Sc and Fe recovery is strong especially when citric acid is used. Based on the exponential relationship between temperature and Fe-recovery it was found to be particularly important for the selectivity of Sc over Fe. Optimization of the model for a maximum Sc recovery combined with a minimum Fe
recovery yielded results of ~28% Sc recovery at <2% Fe recovery at a temperature of 60 ◦C, a citric acid normality of 1.8, and a liquid-to-solid ratio of 16 ml/g. Our study has shown that detailed knowledge about the Sc association and distribution in bauxite and bauxite residue is key to an efficient and selective leaching of Sc
from bauxite residues.
Auslaugversuche wurden mit verschiedenen Bauprodukten durchgeführt, die unter Anwendungsbe-dingungen mit Niederschlägen in Kontakt kommen können. In das Testprogramm wurden Lacke für Außenanwendungen, Wärmedämmverbundsysteme, Dachziegel und polymere Dachfolien einbezogen.
Mit diesen Produkten wurden der von CEN TC 351 entwickelte dynamische Oberflächenauslaugtest (DSLT) und Immersionstests nach EN 16105 durchgeführt. Emissionsverläufe wurden sowohl für an-organische Komponenten als auch für organische Substanzen in den Eluaten ermittelt. Auslaugbare organische Substanzen wurden zuvor in Screeningtests identifiziert.
Um die mögliche Freisetzung von Stoffen aus Bauprodukten beurteilen zu können, ist es erforderlich, Emissionsverläufe zu beschreiben. Dazu sind die verwendeten Testverfahren geeignet. Um Baupro-dukte mit einem Blauen Engel als „Produkte mit geringer Auslaugung“ auszuloben, müssen die aus-laugbaren Substanzen komplett bekannt sein. Für organische Verbindungen ist das noch eine Heraus-forderung. Außerdem erfordert die Bewertung der Testergebnisse sowohl Übertragungsmodelle, die Vorhersagen über freisetzbare Stoffmengen unter Anwendungsbedingungen ermöglichen, als auch Vorgaben zu tolerierbaren Umweltkonzentrationen. Hier besteht noch Handlungsbedarf.
Column leaching tests are frequently used and accepted for investigation of release of hazardous substances from solid materials. Independent of differences due to the field of application or national regulations, column tests assume that local equilibrium is established in the experiment which facilitates transfer of results to field conditions. In the process of harmonization and standardization within Europe the question on the influence of flow rate and grain size distribution on the local equilibrium was raised. Thus, a set of experiments using two different masonry materials with varying grain size distribution and flow rate were conducted including stop/flow experiments. Results are compared to a numerical model which takes intraparticle pore diffusion-controlled release of Mo and V into the percolating water into account. Due to the relatively high intraparticle porosity of the materials (24–29%) data and model indicate that initially equilibrium-state conditions prevail followed by rapidly decreasing concentrations. The model fits data for Mo and V reasonably well; however, after the initial decline of concentrations (at L/S > 2) extended tailing is observed especially of elements occurring as oxides, which is not captured by the model.
Brominated flame retardants have widely been used for more than 50 years and have been frequently detected in environmental samples as surface water and fish. Leaching from construction products was identified as one possible source. The use of substances as e.g. hexabromocyclododecane (HBCCD) was restricted recently due to increasing concern about negative impacts on the environment and human health caused by the persistent, bio accumulative and toxic properties. New polymeric brominated flame retardants have been developed to replace HBCCD in expanded polystyrene (XPS), which is used for insulation of buildings. It is assumed that the release from the polymer is much smaller in comparison to release of small molecules as HBCCD. The release from the polymer may include monomers or small fragments of different size. Thus, a sum parameter is needed. According to Schlummer et al. it is possible to detect brominated molecules using X-ray fluorescence spectroscopy by determination of brome content in XPS extracts. As only small brominated compounds can be extracted it also allows for the differentiation between the two classes of compounds. This method was applied to verify the presence of different kinds of flame retardants in XPS samples and to evaluate the leaching behavior.
Leachiing tests - a useful tool for the environmental impact assessment of construction products?
(2018)
Construction products and waste materials used for construction can be in contact with the environment and may release potential harmful compounds. Information on the total content of these substances in the product is not sufficient to assess its envrionmental impact since it does not consider realistic exposure conditions.The impact of these compounds is often assessed by using the total content in the product. This estimation lacks realistic exposure conditions.
Concerning the pathway to soil and groundwater by contact with rain or seepage water leaching tests, which were developed and standardized by the European Committee for Standardization, are available. While for secondary construction products and waste this investigation of the leaching behaviour is standard procedure and is already part of regulation in Germany (draft ordinance on reuse of mineral waste) and within Europe (landfill directive) the release from primary construction products got in the focus more recently. Several monitoring studies found unexpected high concentrations of substances used as herbicides and fungicides in surface water and stormwater originating from urban areas. As some of these compounds are even banned for the use in agricultural applications in Europe alternative sources as roof materials and façade coatings exposed to rain were suggested. Further field and laboratory tests confirmed construction products as sources of these substances in water.
The aim of this presentation is to show exemplary results of existing leaching methods and underline the strength and weaknesses of the test system with selected examples from our work. We especially draw the attention to the research which is still needed to close the gap between the results of leaching experiments and the subsequent risk assessment of the products.
The potential release of hazardous substances from polymer-based products is currently in the focus of environmental policy. Environmental simulations are applied to expose such products to selected aging conditions and to investigate release processes. Commonly applied aging exposure types such as solar and UV radiation in combination with water contact, corrosive gases, and soil contact as well as expected general effects on polymers and additional ingredients of polymer-based products are described. The release of substances is based on mass-transfer processes to the material surfaces. Experimental approaches to investigate transport processes that are caused by water contact are presented. For tailoring the tests, relevant aging exposure types and release quantification methods must be combined appropriately. Several studies on the release of hazardous substances such as metals, polyaromatic hydrocarbons, flame retardants, antioxidants, and carbon nanotubes from polymers are summarized exemplarily. Differences between natural and artificial exposure tests are discussed and demonstrated for the release of flame retardants from several polymers and for biocides from paints. Requirements and limitations to apply results from short-term artificial environmental exposure tests to predict long-term environmental behavior of polymers are presented.
Throughout their life cycles—from production, usage, through to disposal—materials and products interact with the environment (water, soil, and air). At the same time, they are exposed to environmental influences and, through their emissions, have an impact on the environment, people, and health. Accelerated experimental testing processes can be used to predict the long-term environmental consequences of innovative products before these actually enter the environment.
We are living in a material world. Building materials, geosynthetics, wooden toys, soil, nanomaterials, composites, wastes and more are research subjects examined by the authors of this book. The interactions of materials with the environment are manifold. Therefore, it is important to assess the environmental impact of these interactions. Some answers to how this task can be achieved are given in this Special Issue.