4 Material und Umwelt
Filtern
Dokumenttyp
Referierte Publikation
- ja (20) (entfernen)
Schlagworte
- DRIFTS (5)
- Non-invasive analysis (4)
- Reverse glass painting (4)
- Archaeometry (3)
- Papyrus (3)
- Raman spectroscopy (3)
- Coptic (2)
- Manuscripts (2)
- Pigment identification (2)
- Thermal desorption (2)
Organisationseinheit der BAM
- 4.5 Kunst- und Kulturgutanalyse (20) (entfernen)
Paper des Monats
- ja (1)
Tuschenanalyse im P 11702
(2021)
Near-inframed reflectography and imaging X-Ray flourescence analysis reveal that carbon inks of two different compositions were used in the papyrus manuscript Berlin P 11702. in contrast with the writing ink, one of the carbon drawing inks contained a significant addition of iron. This result emphasises the need for routine instrumental ink analysis.
The miraculously preserved 2000-year-old Dead Sea Scrolls, ancient texts of invaluable historical significance, were discovered in the mid-20th century in the caves of the Judean desert. The texts were mainly written on parchment and exhibit vast diversity in their states of preservation. One particular scroll, the 8-m-long Temple Scroll is especially notable because of its exceptional thinness and bright ivory color. The parchment has a layered structure, consisting of a collagenous base material and an atypical inorganic overlayer. We analyzed the chemistry of the inorganic layer using x-ray and Raman spectroscopies and discovered a variety of evaporitic sulfate salts. This points toward a unique ancient production technology in which the parchment was modified through the addition of the inorganic layer as a writing surface. Furthermore, understanding the properties of these minerals is particularly critical for the development of suitable conservation methods for the preservation of these invaluable historical documents.
On the use of Carbograph 5TD as an adsorbent for sampling VVOCs: validation of an analytical method
(2023)
A standardised method for the analysis of very volatile organic compounds (VVOCs) in indoor air is still missing. This study evaluates the use of Carbograph 5TD as an adsorbent for 60 compounds (47 VVOCs + 13 VOCs) by comparing their recoveries with different spiking modes. The influence of the spiking of the tubes in dry nitrogen, humidified air or along the whole flushing duration mimicking real sampling was investigated. 49 substances (36 VVOCs from C1 to C6) had recoveries over 70% on the adsorbent in humidified air and were validated. The linearity of the calibration curves was verified for every spiking mode and the limits of detection (LOD) and quantification (LOQ) were determined. The LOQs were lower than the existing indoor air guideline values. The robustness of the method was considered by studying the influence of the sampling volume, the sampling flow rate, the humidity level and the storage of the tubes. In general, the most volatile or polar substances were the less robust ones. The combined measurement uncertainty was calculated and lies below 35% for a vast majority of the substances. An example of an emission chamber test using polyurethane foam is shown: Carbograph 5TD performs much better than Tenax® TA for VVOCs and emissions from n-butane were quantified with combined measurement uncertainty.
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.
A non-invasive methodological approach has been carried out to identify the pigments and classify the binding media of the reverse painting on glass Kreuzabnahme (1914/15) by Carlo Mense.
Mense was a member of the group Rhenish Expressionists around August Macke and got interested in the technique of painting on the reverse side of a glass panel. The studied painting indicates a remarkably painted reverse and front side, which creates a unique visual appearance of the glass. The applied noninvasive, spectroscopic approach includes X-ray fluorescence, VIS spectroscopy, Raman spectroscopy and diffuse reflectance infrared Fourier transform spectroscopy. The measurements revealed inorganic Pigments mixed with drying oil as binder. Together with common pigments, such as lead white, barium sulphate, bone black, cinnabar, chrome yellow, ochre, and viridian, an unusual additional material was found, Strontium white.
The emission of ultrafine particles from small desktop Fused Filament Fabrication (FFF) 3D printers has been frequently investigated in the past years. However, the vast majority of FFF emission and exposure studies have not considered the possible occurrence of particles below the typical detection limit of Condensation Particle Counters and could have systematically underestimated the total particle emission as well as the related exposure risks. Therefore, we comparatively measured particle number concentrations and size distributions of sub-4 nm particles with two commercially available diethylene glycol-based instruments – the TSI 3757 Nano Enhancer and the Airmodus A10 Particle Size Magnifier. Both instruments were evaluated for their suitability of measuring FFF-3D printing emissions in the sub-4 nm size range while operated as a particle counter or as a particle size spectrometer. For particle counting, both instruments match best when the Airmodus system was adjusted to a cut-off of 1.5 nm. For size spectroscopy, both instruments show limitations due to either the fast dynamics or rather low levels of particle emissions from FFF-3D printing in this range. The effects are discussed in detail in this article. The findings could be used to implement sub-4 nm particle measurement in future emission or exposure studies, but also for the development of standard test protocols for FFF-3D printing emissions.
The collection Manuscripta Americana in Berlin consists of fragmented codices acquired by Alexander von Humboldt in Mexico. Some of these Humboldt Codices are published as hieroglyphic writings of the Aztecs in “Vues des Cordilleres et Monuments des Peuples indigènes de l’Amerique”. Starting from a special compilation of seven fragments on plate 36 in the “Atlas”, we investigated the corresponding original fragments using material analysis in order to clarify their historical relations. The analyses were carried out with X-ray fluorescence analysis, VIS spectroscopy, and infrared spectroscopy in diffuse reflection and revealed typical indigenous colors like cochineal, indigo, and organic yellows (e.g. mangrove and zacatlaxcalli). Four fragments under investigation show exactly the same material and thus must once have belonged together in one compendium. An additional manuscript from Mizquiahuala also shown on plate 36 can be matched to another one that is not published in the “Atlas”.
In the transition from carbon to iron-gall inks, the two documents from the Egyptian Museum and Papyrus Collection in Berlin with shelfmarks P 13500 and P 13501 discussed in this work present an important case. Their inks appear brownish, although they date back to the fourth and third century BCE, when carbon inks are believed to have been commonly if not exclusively used. Using imaging micro-X-ray fluorescence and infrared reflectography, we discovered that the inks in both documents contain a significant amount of copper in addition to carbon. Comparing the extant recipes for black writing inks and the experimental evidence, we suggest that these inks are a transition between the pure carbon and the iron-gall inks. Such inks may have been quite common before the production of iron-gall ink was clearly understood and established.
This work highlights the rediscovery of the technique of reverse glass painting by the artists of the “Blaue Reiter” collective in the early 20th-century and focusses particularly on the role of Wassily Kandinsky (1866–1944). Kandinsky created more than 70 reverse paintings on glass and showed several of them in exhibitions together with paintings on canvas and cardboard, implying a coequal importance of these techniques. Four of his early (1911–1914) reverse glass paintings (Auferstehung, Allerheiligen II, Rudern, Apokalyptischer Reiter II) were selected for investigation and their iconography, painting techniques and painting materials were examined. Two paintings were executed on so-called cathedral glass, revealing a “hammered surface”, whereas Kandinsky used a corrugated glass panel for Rudern. A multi-analytical, non-invasive approach [X-ray fluorescence (XRF), diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), VIS spectroscopy (VIS), Raman spectroscopy] was taken to identify the pigments and classify the binding media. The results reveal a broad palette of materials. Several pigments like lead white, zinc white, Strontium yellow, Prussian blue, viridian, cadmium yellow, ultramarine blue, cinnabar and carbon black were found in most of the four paintings. The use of the rare synthetic organic pigments PR60 and PB52 is discussed. In two works of art, cadmium carbonate is associated with cadmium yellow. The identification of aluminium foil along with tin foils in Rudern indicates an early use of this material for reverse glass paintings.
Fused filament fabrication (FFF) is a material extrusion-based technique often used in desktop 3D printers. Polymeric filaments are melted and are extruded through a heated nozzle to form a 3D object in layers. The extruder temperature is therefore a key parameter for a successful print job but also one of the main emission driving factors as harmful pollutants (e.g., ultrafine particles) are formed by thermal polymer degradation. The awareness of potential health risks has increased the number of emission studies in the past years. However, studies usually refer their calculated emission data to the printer set extruder temperature for comparison purposes. In this study, we used a thermocouple and an infrared camera to measure the actual extruder temperature and found significant temperature deviations to the displayed set temperature among printer models. Our result shows that printing the same filament feedstocks with three different printer models and with identical printer set temperature resulted in a variation in particle emission of around two orders of magnitude. A temperature adjustment has reduced the variation to approx. one order of magnitude. Thus, it is necessary to refer the measured emission data to the actual extruder temperature as it poses a more accurate comparison parameter for evaluation of the indoor air quality in user scenarios or for health risk assessments.