4 Material und Umwelt
Filtern
Dokumenttyp
- Vortrag (77)
- Zeitschriftenartikel (43)
- Posterpräsentation (24)
- Beitrag zu einem Tagungsband (17)
- Sonstiges (5)
- Forschungsbericht (4)
- Monografie (1)
- Buchkapitel (1)
- Forschungsdatensatz (1)
Schlagworte
- Nano (29)
- OECD (20)
- Nanomaterial (14)
- VOC (13)
- Bauprodukte (12)
- Emission (9)
- Prüfrichtlinie (9)
- Volatile organic compounds (8)
- Aerosol (7)
- BEMMA (7)
- Cascade impactor (7)
- ISO 16000-6 (7)
- Nanopartikel (7)
- EN 16516 (6)
- Geruch (6)
- TXRF (6)
- Emissionen (5)
- Museum (5)
- Nanomaterials (5)
- Nanoparticle (5)
- Reference material (5)
- Test guideline (5)
- Umweltsimulation (5)
- VVOCs (5)
- Analytical method (4)
- Architecture (4)
- Bundesoberbehörden (4)
- Chemical durability (4)
- Construction products (4)
- Corrosion (4)
- Emission test chamber (4)
- Formaldehyd (4)
- Gas chromatography (4)
- Guideline (4)
- Standardisation (4)
- Thermal desorption (4)
- UFP (4)
- Affinity chromatography (3)
- Air quality monitoring (3)
- Antibodies (3)
- ESEM (3)
- Electron microscopy (3)
- FFF-3D-Printer (3)
- Geruchsmessung (3)
- Glass (3)
- Low melting (3)
- Luftschadstoffe (3)
- Particle size distribution (3)
- Partikel (3)
- Perceived Intensity (3)
- Polyglycerol (3)
- Reference materials (3)
- Size (3)
- VOC-emission (3)
- Weathering (3)
- Additive Fertigung (2)
- Additive Manufacturing (2)
- Additive Manufacturing (AM) (2)
- Aerosol measurements (2)
- Aerosole (2)
- Air exchange rate (2)
- Ambient aerosols (2)
- Analytik (2)
- Behördenklausurtagung (2)
- Bewitterung (2)
- Biofilm (2)
- Biofilms (2)
- CO2 assisted impregnation (2)
- Capsules (2)
- Chamber test (2)
- Chemical analysis (2)
- Chemical characterization (2)
- Consumer products (2)
- Corona (2)
- Crystallization (2)
- DIN EN 16516 (2)
- Elektronisches Laborbuch (2)
- Element mass concentration (2)
- Emission chamber (2)
- Emission reference material (2)
- Emissions (2)
- Emissionskammer (2)
- Environmental simulation (2)
- European standard (2)
- FEM model (2)
- Fluorescence (2)
- Formaldehyde (2)
- Fume (2)
- GAeF (2)
- Glasmalfarben (2)
- Glutaraldehyde (2)
- Größenbestimmung (2)
- ICP-MS (2)
- Indoor air quality (2)
- Innenraum (2)
- Iron oxide nanoparticles (2)
- LA-ICP-MS (2)
- Laser Powder Bed Fusion (L-PBF) (2)
- Loading factor (2)
- Luft (2)
- MOF (2)
- Material emissions (2)
- Microbiome (2)
- Microplastics (2)
- Nano particle (2)
- Nanofasern (2)
- Nanomaterialien (2)
- Particle gas emission (2)
- Particle size (2)
- Particle size distributuion (2)
- Particles (2)
- Particulate emission (2)
- Plume (2)
- Pollutants (2)
- Prozessmonitoring (2)
- Purification (2)
- Radon (2)
- Reductive amination (2)
- Reference method (2)
- Round robin test (2)
- Sapphire (2)
- Schadstoffaustrag (2)
- Size distribution (2)
- Size resolved chemical composition (2)
- Spatter (2)
- Struvite (2)
- Test Guideline (2)
- Testguideline (2)
- Thermal extraction (2)
- Time resolved chemical composition (2)
- Total reflection X-ray spectroscopy (2)
- Ultrafine particles (2)
- VOC Emissionen (2)
- VOC-Emissionen (2)
- VVOC (2)
- Vitrinen (2)
- Wooden toys (2)
- 3D Printing (1)
- 3D printer (1)
- 3D printing (1)
- AEROMET II (1)
- AEROMET project (1)
- Accuracy (1)
- Additive manufacturing (1)
- Advanced Materials (1)
- Aerosol element alanysis (1)
- Aerosol element mass concentration (1)
- Aerosol gravimetry (1)
- Aerosol measurement instruments (1)
- Aerosol spectroscopy (1)
- Aerosolforschung (1)
- Aerosols (1)
- Aerosolsensor (1)
- Affinity extraction (1)
- Affinity support (1)
- AgBB Bewertung (1)
- Aging test (1)
- Aging tests (1)
- Air analysis (1)
- Air pollution (1)
- Air quality (1)
- Air sampling (1)
- Airborne Particles (1)
- Alkali zinc borate glass (1)
- Aluminium (1)
- Aluminum (1)
- Aluminum oxide (1)
- Ambient air (1)
- Ambient air pollution (1)
- Amino acid analysis (1)
- Ammoniak (1)
- Analytical chemistry (1)
- Analytische Methode (1)
- Anodization (1)
- Antibody purification (1)
- Aqueous synthesis (1)
- Architektur (1)
- Aromatic amino acid analysis AAAA (1)
- Aromatic amino acid analysis aaaa (1)
- BAM Data Store (1)
- BEMMA Bewertung (1)
- BFR (1)
- BMU (1)
- BODIPY dye (1)
- BSA (1)
- Bauproduktenverordnung (1)
- Beschichtung (1)
- Bewertung (1)
- Bewertungsverfahren (1)
- Bio-based insulation (1)
- Bio-weathering (1)
- Bioactive glass (1)
- Bioconjugation (1)
- Bioseparation (1)
- Biosphere (1)
- Black fungi (1)
- Blauer Engel (1)
- Blue Angel ecolabel (1)
- Bodenbelag (1)
- Bodenbeläge (1)
- Bovine serum albumin (1)
- Building product (1)
- Building products (1)
- Bürogeräte mit Druckfunktion (1)
- CCQM (1)
- COVID (1)
- CPC calibration (1)
- CRM (1)
- Calibration (1)
- Calibration transfer (1)
- Carrier (1)
- Cellulose ether (1)
- Cerium oxide (1)
- Chamber measurement (1)
- Characterisation (1)
- Characterization (1)
- Chemical composition (1)
- Chemische Beständigkeit (1)
- Climate responsive materials (1)
- Cobalt (1)
- Cognitive performance (1)
- Colored glasses (1)
- Comparison (1)
- Conservation (1)
- Construction Products (1)
- Construction product (1)
- Consumer article (1)
- Consumer articles (1)
- Core/shell nanoparticle (1)
- Corundum (1)
- Covid (1)
- Cross-sectioning (1)
- Cubical shape (1)
- DIN EN 717-1 (1)
- DMAS (1)
- Damage repair (1)
- Dendrimer (1)
- Diffusive sampling (1)
- Digitalisation (1)
- Digitalisierung (1)
- Dispay case (1)
- Dispergierung von Glaspartikeln (1)
- Dispersion of glass particle (1)
- Display case (1)
- Downstream processing (1)
- Druck (1)
- EDX Analysis (1)
- EN 717-1 (1)
- EN 717-3 (1)
- EU EMPIR (1)
- EU regulations (1)
- Earthen building materials (1)
- Effective uptake rate (1)
- Electronic Lab Notebook (ELN) (1)
- Electronic lab notebook (ELN) (1)
- Elektrolichtbogenofen (1)
- Element analysis (1)
- Elemental aerosol analysis (1)
- Elemental composition (1)
- Emerging Contaminants (1)
- Emission Test Chamber (1)
- Emission Testing (1)
- Emission chamber testing (1)
- Emission chambers (1)
- Emission reference materials (1)
- Emission test chamber procedure (1)
- Emission test method (1)
- Emissions of hazardous gases (1)
- Emissionsmessungen (1)
- Emissionsprüfkammer (1)
- Emissionsprüfung (1)
- Emisson testing (1)
- Enamel colors (1)
- Enamels (1)
- Environment (1)
- Environmental friendly (1)
- Exposure (1)
- Exposure risk (1)
- Extracellular pH (1)
- Extracellular polymeric substances (1)
- FFF-filament (1)
- FFF-printing (1)
- Faraday cup aerosol electrometer (1)
- Fatigue (1)
- Fiber (1)
- Fibre (1)
- Filament comparison (1)
- Flammschutzmittel (1)
- Flask method (1)
- Flexible shadow masks (1)
- Fluorometric sensing (1)
- Food (1)
- Forest fires (1)
- Forschungsdatenmanagement (1)
- Forschungsstrategie (1)
- Forsterite (1)
- Fungus (1)
- Gas analysis (1)
- Gas sensing (1)
- Gesundheit (1)
- Glas (1)
- Glasanalyse (1)
- Größe (1)
- Haze Samples (1)
- Heavy metal free (1)
- Historic buildings (1)
- Human plasma (1)
- Hyperbranched polymer (1)
- IAQ (1)
- IEQ (1)
- ISO REMCO (1)
- ISO/TC 229 Nanotechnologies (1)
- Idiopathic environmental intolerance (1)
- Igg (1)
- Immunoglobulins (1)
- Immunoprecipitation (1)
- In-situ Process Monitoring (1)
- In-situ analysis (1)
- Indoor Air Quality (1)
- Indoor Air: Adsorbent performance (1)
- Indoor Products (1)
- Indoor emission (1)
- Innenraumluft (1)
- Innenraumluftqualität (1)
- Innenraumluftqualtität (1)
- Inter-comparison (1)
- Inter-lab comparison (1)
- Intercomparison (1)
- Interlaboratory comparison (1)
- Iron oxide (1)
- Knock-out mutant (1)
- LCC (1)
- Lapis lazuli (1)
- Laser Printer (1)
- Laser printer emission (1)
- Layer-by-Layer (1)
- Linker (1)
- Low melting glasses (1)
- Low-tech approach (1)
- Luftgüte (1)
- Market surveillance (1)
- Mask fabrication (1)
- Material emissions testing (1)
- Mechanochemistry (1)
- Medieval glasses (1)
- Melanin Adhesion (1)
- Metallic silver precipitates (1)
- Metals (1)
- Methoden (1)
- Micro-XRF (1)
- Microchamber (1)
- Micropatterning (1)
- Migration (1)
- Mobile anodisation (1)
- Mobile application (1)
- Model aerosols (1)
- Molecular Organic Frameworks (1)
- Monoterpene (1)
- Multigassensorik (1)
- Multiple Displacement Amplification (1)
- Multiple chemical sensitivity (1)
- Museumsvitrine (1)
- Museumsvitrinen (1)
- NDT (1)
- NFDI (1)
- NGS (1)
- Nano CRM (1)
- Nano@BAM (1)
- NanoPlattform (1)
- Nanocarrier (1)
- Nanoparticles (1)
- Nanoplattform (1)
- Nanopowder (1)
- Nanosensor (1)
- Nanotechnologie (1)
- Neuartige Materialien (1)
- Nickel (1)
- Niedrig schmelzend (1)
- Non-destructive Materials (1)
- Nonspecific binding (NSB) (1)
- Novel sample preparation techniques (1)
- Oddy test (1)
- Odour (1)
- Office machines (1)
- Olivine (1)
- OpenBIS (1)
- Operating Procedure (1)
- Optical properties (1)
- Optische Tomografie (1)
- PBFSM (1)
- PGAA (1)
- PIXE (1)
- PM monitors (1)
- PP (1)
- PS (1)
- Particle (1)
- Particle Size (1)
- Particle emission (1)
- Particulate emissions (1)
- Partikeldurchmesser (1)
- Parylene C (1)
- Passive sampling (1)
- Periodate oxidation (1)
- Perowskit (1)
- Phase separation (1)
- Phosphates (1)
- Phosphonic acids (1)
- Phosphorous recovery (1)
- Phototrophic bacteria (1)
- Pigment analyses (1)
- Pilot comparison (1)
- Plastic biofilm (1)
- Plastic pollution (1)
- Polyelektrolyt (1)
- Polymer (1)
- Polypropylen (1)
- Polystyrol (1)
- Printing (1)
- ProMoAM (1)
- Process development (1)
- Process monitoring (1)
- Proficiency testing (1)
- Protein (1)
- Protein a (1)
- Protein hydrolysis (1)
- Protein immobilization (1)
- Protein quantification (1)
- Proton conductivity (1)
- Provenance studies (1)
- Prüfkammer (1)
- Prürfrichtlinie (1)
- QA/QC (1)
- Quality assurance (1)
- Quantum dot (1)
- REACH (1)
- RFA (1)
- Radon exhalation (1)
- Recovery rate (1)
- Recycling (1)
- Reduktionsprozess (1)
- Reference data (1)
- Reference nanoparticles (1)
- Reference procedures (1)
- Reference samples (1)
- Release kinetics (1)
- Research Data Infrastructure (1)
- Research Data Management (1)
- Research data management (1)
- Ringversuch (1)
- Robustness validation (1)
- Rround robin test (1)
- SARS (1)
- SAXS (1)
- SDS-PAGE (1)
- SMPS (1)
- SOP (1)
- Safety (1)
- Sample preparation (1)
- Schadgase (1)
- Schutzverglasung (1)
- Selective quantification (1)
- Self-assembled monolayer (SAM) (1)
- Self-assembled monolayers (SAM) (1)
- Semivolatile organic compounds (1)
- Sensor (1)
- Silver diffusion (1)
- Sintering (1)
- Small angle x-ray scattering (1)
- Solid phase (1)
- Solid-phase extraction (SPE) (1)
- Solvents (1)
- Spectroscopy (1)
- Spielzeug (1)
- Stained glasses (1)
- Standardarbeitsanweisungen (1)
- Subjective complaints (1)
- Surface chemistry (1)
- Sustainability (1)
- Synthesis (1)
- TEM (1)
- TXRF ambient air aerosol chemical analysis aerosol element composition (1)
- Tantal (1)
- Targeting, Nanoparticles (1)
- Test method (1)
- Thermal Desorption (1)
- Thermal Extraction (1)
- Thermal properties (1)
- Thermografie (1)
- Thermoplastic filaments (1)
- Transition metals (1)
- Transmission electron microscopy (1)
- Tyrosine (1)
- UV absorption (1)
- UV protection (1)
- Umweltmessung (1)
- Up-cycling (1)
- Uptake rate (1)
- VAMAS (1)
- VOC Emission (1)
- VOC emission (1)
- VOC transfer standards (1)
- VOC-Emission (1)
- Vitrine (1)
- Volatile organic compound (1)
- Volatile organic compounds (VOC) (1)
- WKI flask method (1)
- Weathering tests (1)
- Workflows (1)
- X-Ray analysis (1)
- XRF (1)
- ZIF (1)
- ZIF-8 (1)
- Zeolithe (1)
- Zinc oxide (1)
- natural ventilation (1)
- openBIS (1)
- pH (1)
- pH sensor (1)
- pHe (1)
- Äquivalenzdurchmesser (1)
Organisationseinheit der BAM
- 4.2 Material-Mikrobiom Wechselwirkungen (173) (entfernen)
Paper des Monats
- ja (3)
EN 16516 sets the test method and requirements for the determination of emissions of Volatile Organic Compounds (VOCs) from building materials into indoor air. To address the quality control requirements for the class of semi-VOCs (SVOCs), VSL developed gaseous reference materials. A novel home-made dynamic gas mixture preparation system, operating according to ISO 6145-4 (continuous injection method), has recently been developed and validated. Thanks to the stable temperature control up to 100 oC, the system can prevent condensation of the SVOCs in air at indoor air concentration levels. The in-situ obtained SVOC gas standards can be sampled in sorbent tubes to obtain SVOC transfer standards. A study was performed to determine the optimal sorbent material and storage conditions. This study will be presented together with the results of the 2018 Round Robin test for emission test chamber measurements organised by BAM. Using the novel system, VSL prepared transfer standards with known amounts of VOCs and SVOCs for participants to evaluate their analytical performance.
The chemical emissions from products are tested by means of emission test chambers under defined conditions (climate, loading, air change rate). The standard method for the determination of volatile organic compounds (VOC) is the sampling onto Tenax-tubes followed by thermal desorption (TDS) and gas chromatography-mass spectrometry (GC-MS) analysis. The EU-LCI list includes some very volatile organic compounds (VVOC) and some VOC for which there are limitations when using the standard method. For VVOC additional sampling is required using stronger absorbers like Carbotrap or multi-bed adsorption tubes. The analysis of VVOC also requires a different GC oven program and a different column for the separation. For the determination of formaldehyde and other low boiling aldehydes (e.g. acetaldehyde, acetone, propanal, propenal) DNPH-cartridges are used which are extracted with acetonitrile followed by liquid chromatography (HPLC-UV) analysis. The derivatisation of propenal and other unsaturated aldehydes (e.g. 2-butenal) with DNPH might lead to lower findings due to incomplete derivatization and forming of by-products. For a better quantification of acetic acid the use of ion chromatography (IC) is recommended because the analysis of acetic acid with the standard method (TDS) leads to lower findings due to break through during sampling. The use of ion chromatography for the analysis of organic acids requires a third sampling technique. The acids are adsorbed onto silica-gel and extracted with water.
Laser Powder Bed Fusion (L-PBF) is a promising additive manufacturing (AM) technology for metal part production especially for complex and lightweight structures or functional designs. In L PBF processes several by-products including welding plume and its condensates, spatter and ejected powder are generated during laser exposure. Investigations of micro- and nano-sized by-products have received little attention in literature. This study focuses on the analysis of particle emissions in L PBF of 316L stainless steel using a scattered light aerosol spectrometer and a fast mobility particle sizer spectrometer during the process which allows for in-situ analysis of particle sizes in the range of 6 nm to 100 µm. A distinct correlation of emission signals to part position can be revealed. In addition, a significant influence of laser scanning vector directions on emission signals is presented. Furthermore, differing powder layer thicknesses can be recognised by deviations in emission signals.
Laser Powder Bed Fusion (L-PBF) is a promising additive manufacturing (AM) technology for metal part production especially for complex and lightweight structures or functional designs. In L PBF processes several by-products including welding plume and its condensates, spatter and ejected powder are generated during laser exposure. Investigations of micro- and nano-sized by-products have received little attention in literature. This study focuses on the analysis of particle emissions in L PBF of 316L stainless steel using a scattered light aerosol spectrometer and a fast mobility particle sizer spectrometer during the process which allows for in-situ analysis of particle sizes in the range of 6 nm to 100 µm. A distinct correlation of emission signals to part position can be revealed. In addition, a significant influence of laser scanning vector directions on emission signals is presented. Furthermore, differing powder layer thicknesses can be recognised by deviations in emission signals.
Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat.
Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits¬anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor.
Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012.
The ISO 16000 standard series provide guidelines for emission measurements of volatile organic compounds (VOCs) from building materials. However, polymer-based consumer products such as toys may also release harmful substances into indoor air. In such cases, the existing standard procedures are unsuitable for official control laboratories due to high costs for large emission testing chambers. This paper aims at developing and comparing alternative and more competitive methods for the emission testing of consumer products. The influence of the emission chamber size was investigated as smaller chambers are more suited to the common size of consumer products and may help to reduce the costs of testing. Comparison of the performance of a 203 l emission test chamber with two smaller chambers with the capacity of 24 l and 44 ml, respectively, was carried out by using a polyurethane reference material spiked with 14 VOCs during the course of 28 days. The area-specific emission rates obtained in the small chambers were always similar to those of the 203 l reference chamber after a few hours. This implies that smaller chambers can provide at least useful numbers on the extent of polymer-based consumer product emissions into indoor air, thereby supporting meaningful exposure assessments.
Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat.
Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits-anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor.
Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012.
A reliable analysis of aerosol particle is curial for enforcing EU air quality regulations to protect human health, and for research on climate change effects [1]. Although metrics such as PM10 and PM2.5 are currently in use, the level of uncertainty of aerosol metrics is too high and the traceability is insufficient. Within the AEROMET project [2] procedures are developed aiming at reducing the uncertainties of particle mass, size, and number concentration measurements including the characterization of regulated components in airborne particles. Here, we present an approach how to improve the uncertainties of the particle mass by mobile total reflection x-ray fluorescence (TXRF) analysis. The combination of TXRF and aerosols sampling techniques supported by reference-free synchrotron radiation-based XRF enables a quantitative real-time analysis of particle mass. During in-field campaigns, the procedure was tested, monitoring the size dependent mass concentrations of specific elements in ambient aerosols under dynamic conditions. This approach allows a direct time and size-resolved analysis without laborious digestion steps and a reduced risk of contamination.
Aerosol particles were sampled in a 13-stage DLPI impactor on acrylic discs. TXRF analysis was performed on-site with the transportable spectrometer S2 PICOFOX (Bruker Nano GmbH). The TXRF quantification was based on internal standardization. At moderate air pollution levels (PM10 20 µg/m³) sampling times of less than 2 hours were enough to detect elements in different particle size bins. The on-site approach and the high sensitivity of TXRF enables the observation of rather quick changes in the quantity and distribution of elements in an ambient aerosol on the day of sampling. The analysis of the morning and afternoon sampling shifts reveals the occurrence of the elements Fe, Ca and Si in different size bins as well as their temporal change in respective mass concentrations over the day while the distributions of several other elements remain unchanged.
Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren.
Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden.
Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. Diese Entwicklungen werden hier aufgezeigt.
The objective of this study is to find out, to what extent the geochemical characteristics of lapis lazuli can be utilized in respect to its provenance. A wide range of variables is taken into consideration depending on the quantity of samples analysed from a specific geological region and the methods applied. In order to provide evidence, a multi-technique analytical approach using µXRF, ESEM, PGAA and PIXE is applied to samples from the most famous deposits of lapis lazuli. Special elements determined as fingerprints are compared in relation to the forming conditions obvious in textural features. The results and statistical output allow a differentiation that enables an optimized local classification of the blue stone. An absolute requirement for all geo-tracing performed on blue colored cultural objects of unknown provenance is awareness of the limits of analysis. The possible sources of lapis lazuli are tested by analysing the blue pigment used as paint on murals and ink on manuscripts from the Silk Road.