4 Material und Umwelt
Filtern
Dokumenttyp
- Vortrag (77)
- Zeitschriftenartikel (44)
- Posterpräsentation (24)
- Beitrag zu einem Tagungsband (17)
- Sonstiges (4)
- Forschungsbericht (4)
- Monografie (1)
- Buchkapitel (1)
- Preprint (1)
- Forschungsdatensatz (1)
Schlagworte
- Nano (29)
- OECD (20)
- Nanomaterial (14)
- VOC (13)
- Bauprodukte (12)
- Emission (9)
- Prüfrichtlinie (9)
- Volatile organic compounds (8)
- Aerosol (7)
- BEMMA (7)
- Cascade impactor (7)
- ISO 16000-6 (7)
- Nanopartikel (7)
- EN 16516 (6)
- Geruch (6)
- TXRF (6)
- Emissionen (5)
- Museum (5)
- Nanomaterials (5)
- Nanoparticle (5)
- Reference material (5)
- Test guideline (5)
- Umweltsimulation (5)
- VVOCs (5)
- Analytical method (4)
- Architecture (4)
- Bundesoberbehörden (4)
- Chemical durability (4)
- Construction products (4)
- Corrosion (4)
- Emission test chamber (4)
- Formaldehyd (4)
- Gas chromatography (4)
- Guideline (4)
- Standardisation (4)
- Thermal desorption (4)
- UFP (4)
- Affinity chromatography (3)
- Air quality monitoring (3)
- Antibodies (3)
- Biofilm (3)
- ESEM (3)
- Electron microscopy (3)
- FFF-3D-Printer (3)
- Geruchsmessung (3)
- Glass (3)
- Low melting (3)
- Luftschadstoffe (3)
- Microplastics (3)
- Particle size distribution (3)
- Partikel (3)
- Perceived Intensity (3)
- Polyglycerol (3)
- Reference materials (3)
- Size (3)
- VOC-emission (3)
- Weathering (3)
- Additive Fertigung (2)
- Additive Manufacturing (2)
- Additive Manufacturing (AM) (2)
- Aerosol measurements (2)
- Aerosole (2)
- Air exchange rate (2)
- Ambient aerosols (2)
- Analytik (2)
- Behördenklausurtagung (2)
- Bewitterung (2)
- Biofilms (2)
- CO2 assisted impregnation (2)
- Capsules (2)
- Chamber test (2)
- Chemical analysis (2)
- Chemical characterization (2)
- Consumer products (2)
- Corona (2)
- Crystallization (2)
- DIN EN 16516 (2)
- Elektronisches Laborbuch (2)
- Element mass concentration (2)
- Emission chamber (2)
- Emission reference material (2)
- Emissions (2)
- Emissionskammer (2)
- Environmental simulation (2)
- European standard (2)
- FEM model (2)
- Fluorescence (2)
- Formaldehyde (2)
- Fume (2)
- GAeF (2)
- Glasmalfarben (2)
- Glutaraldehyde (2)
- Größenbestimmung (2)
- ICP-MS (2)
- Indoor air quality (2)
- Innenraum (2)
- Iron oxide nanoparticles (2)
- LA-ICP-MS (2)
- Laser Powder Bed Fusion (L-PBF) (2)
- Loading factor (2)
- Luft (2)
- MOF (2)
- Material emissions (2)
- Microbiome (2)
- Nano particle (2)
- Nanofasern (2)
- Nanomaterialien (2)
- Particle gas emission (2)
- Particle size (2)
- Particle size distributuion (2)
- Particles (2)
- Particulate emission (2)
- Plume (2)
- Pollutants (2)
- Prozessmonitoring (2)
- Purification (2)
- Radon (2)
- Reductive amination (2)
- Reference method (2)
- Round robin test (2)
- Sapphire (2)
- Schadstoffaustrag (2)
- Size distribution (2)
- Size resolved chemical composition (2)
- Spatter (2)
- Struvite (2)
- Test Guideline (2)
- Testguideline (2)
- Thermal extraction (2)
- Time resolved chemical composition (2)
- Total reflection X-ray spectroscopy (2)
- Ultrafine particles (2)
- VOC Emissionen (2)
- VOC-Emissionen (2)
- VVOC (2)
- Vitrinen (2)
- Wooden toys (2)
- 3D Printing (1)
- 3D printer (1)
- 3D printing (1)
- AEROMET II (1)
- AEROMET project (1)
- Accuracy (1)
- Additive manufacturing (1)
- Advanced Materials (1)
- Aerosol element alanysis (1)
- Aerosol element mass concentration (1)
- Aerosol gravimetry (1)
- Aerosol measurement instruments (1)
- Aerosol spectroscopy (1)
- Aerosolforschung (1)
- Aerosols (1)
- Aerosolsensor (1)
- Affinity extraction (1)
- Affinity support (1)
- AgBB Bewertung (1)
- Aging test (1)
- Aging tests (1)
- Air analysis (1)
- Air pollution (1)
- Air quality (1)
- Air sampling (1)
- Airborne Particles (1)
- Alkali zinc borate glass (1)
- Aluminium (1)
- Aluminum (1)
- Aluminum oxide (1)
- Ambient air (1)
- Ambient air pollution (1)
- Amino acid analysis (1)
- Ammoniak (1)
- Analytical chemistry (1)
- Analytische Methode (1)
- Anodization (1)
- Antibody purification (1)
- Aqueous synthesis (1)
- Architektur (1)
- Aromatic amino acid analysis AAAA (1)
- Aromatic amino acid analysis aaaa (1)
- BAM Data Store (1)
- BEMMA Bewertung (1)
- BFR (1)
- BMU (1)
- BODIPY dye (1)
- BSA (1)
- Bauproduktenverordnung (1)
- Beschichtung (1)
- Bewertung (1)
- Bewertungsverfahren (1)
- Bio-based insulation (1)
- Bio-weathering (1)
- Bioactive glass (1)
- Bioconjugation (1)
- Bioseparation (1)
- Biosphere (1)
- Black fungi (1)
- Blauer Engel (1)
- Blue Angel ecolabel (1)
- Bodenbelag (1)
- Bodenbeläge (1)
- Bovine serum albumin (1)
- Building product (1)
- Building products (1)
- Bürogeräte mit Druckfunktion (1)
- CCQM (1)
- COVID (1)
- CPC calibration (1)
- CRM (1)
- Calibration (1)
- Calibration transfer (1)
- Carrier (1)
- Cellulose ether (1)
- Cerium oxide (1)
- Chamber measurement (1)
- Characterisation (1)
- Characterization (1)
- Chemical composition (1)
- Chemische Beständigkeit (1)
- Climate responsive materials (1)
- Cobalt (1)
- Cognitive performance (1)
- Colored glasses (1)
- Comparison (1)
- Conservation (1)
- Construction Products (1)
- Construction product (1)
- Consumer article (1)
- Consumer articles (1)
- Core/shell nanoparticle (1)
- Corundum (1)
- Covid (1)
- Cross-sectioning (1)
- Cubical shape (1)
- DIN EN 717-1 (1)
- DMAS (1)
- Damage repair (1)
- Dendrimer (1)
- Diffusive sampling (1)
- Digitalisation (1)
- Digitalisierung (1)
- Dispay case (1)
- Dispergierung von Glaspartikeln (1)
- Dispersion of glass particle (1)
- Display case (1)
- Downstream processing (1)
- Druck (1)
- EDX Analysis (1)
- EN 717-1 (1)
- EN 717-3 (1)
- EU EMPIR (1)
- EU regulations (1)
- Earthen building materials (1)
- Effective uptake rate (1)
- Electronic Lab Notebook (ELN) (1)
- Electronic lab notebook (ELN) (1)
- Elektrolichtbogenofen (1)
- Element analysis (1)
- Elemental aerosol analysis (1)
- Elemental composition (1)
- Emerging Contaminants (1)
- Emission Test Chamber (1)
- Emission Testing (1)
- Emission chamber testing (1)
- Emission chambers (1)
- Emission reference materials (1)
- Emission test chamber procedure (1)
- Emission test method (1)
- Emissions of hazardous gases (1)
- Emissionsmessungen (1)
- Emissionsprüfkammer (1)
- Emissionsprüfung (1)
- Emisson testing (1)
- Enamel colors (1)
- Enamels (1)
- Environment (1)
- Environmental friendly (1)
- Exposure (1)
- Exposure risk (1)
- Extracellular pH (1)
- Extracellular polymeric substances (1)
- FFF-filament (1)
- FFF-printing (1)
- Faraday cup aerosol electrometer (1)
- Fatigue (1)
- Fiber (1)
- Fibre (1)
- Filament comparison (1)
- Flammschutzmittel (1)
- Flask method (1)
- Flexible shadow masks (1)
- Fluorometric sensing (1)
- Food (1)
- Forest fires (1)
- Forschungsdatenmanagement (1)
- Forschungsstrategie (1)
- Forsterite (1)
- Fungus (1)
- Gas analysis (1)
- Gas sensing (1)
- Gesundheit (1)
- Glas (1)
- Glasanalyse (1)
- Größe (1)
- Haze Samples (1)
- Heavy metal free (1)
- Historic buildings (1)
- Human plasma (1)
- Hyperbranched polymer (1)
- IAQ (1)
- IEQ (1)
- ISO REMCO (1)
- ISO/TC 229 Nanotechnologies (1)
- Idiopathic environmental intolerance (1)
- Igg (1)
- Immunoglobulins (1)
- Immunoprecipitation (1)
- In-situ Process Monitoring (1)
- In-situ analysis (1)
- Indoor Air Quality (1)
- Indoor Air: Adsorbent performance (1)
- Indoor Products (1)
- Indoor emission (1)
- Innenraumluft (1)
- Innenraumluftqualität (1)
- Innenraumluftqualtität (1)
- Inter-comparison (1)
- Inter-lab comparison (1)
- Intercomparison (1)
- Interlaboratory comparison (1)
- Iron oxide (1)
- Knock-out mutant (1)
- LCC (1)
- Lapis lazuli (1)
- Laser Printer (1)
- Laser printer emission (1)
- Layer-by-Layer (1)
- Linker (1)
- Low melting glasses (1)
- Low-tech approach (1)
- Luftgüte (1)
- Market surveillance (1)
- Mask fabrication (1)
- Material emissions testing (1)
- Mechanochemistry (1)
- Medieval glasses (1)
- Melanin Adhesion (1)
- Metallic silver precipitates (1)
- Metals (1)
- Methoden (1)
- Micro-XRF (1)
- Microchamber (1)
- Microorganisms (1)
- Micropatterning (1)
- Migration (1)
- Mobile anodisation (1)
- Mobile application (1)
- Model aerosols (1)
- Molecular Organic Frameworks (1)
- Monoterpene (1)
- Multigassensorik (1)
- Multiple Displacement Amplification (1)
- Multiple chemical sensitivity (1)
- Museumsvitrine (1)
- Museumsvitrinen (1)
- NDT (1)
- NFDI (1)
- NGS (1)
- Nano CRM (1)
- Nano@BAM (1)
- NanoPlattform (1)
- Nanocarrier (1)
- Nanoparticles (1)
- Nanoplattform (1)
- Nanopowder (1)
- Nanosensor (1)
- Nanotechnologie (1)
- Neuartige Materialien (1)
- Nickel (1)
- Niedrig schmelzend (1)
- Non-destructive Materials (1)
- Nonspecific binding (NSB) (1)
- Novel sample preparation techniques (1)
- Oddy test (1)
- Odour (1)
- Office machines (1)
- Olivine (1)
- OpenBIS (1)
- Operating Procedure (1)
- Optical properties (1)
- Optische Tomografie (1)
- PBFSM (1)
- PGAA (1)
- PIXE (1)
- PM monitors (1)
- PP (1)
- PS (1)
- Particle (1)
- Particle Size (1)
- Particle emission (1)
- Particulate emissions (1)
- Partikeldurchmesser (1)
- Parylene C (1)
- Passive sampling (1)
- Periodate oxidation (1)
- Perowskit (1)
- Phase separation (1)
- Phosphates (1)
- Phosphonic acids (1)
- Phosphorous recovery (1)
- Phototrophic bacteria (1)
- Pigment (1)
- Pigment analyses (1)
- Pilot comparison (1)
- Plastic biofilm (1)
- Plastic pollution (1)
- Polyelektrolyt (1)
- Polymer (1)
- Polypropylen (1)
- Polystyrol (1)
- Printing (1)
- ProMoAM (1)
- Process development (1)
- Process monitoring (1)
- Proficiency testing (1)
- Protein (1)
- Protein a (1)
- Protein hydrolysis (1)
- Protein immobilization (1)
- Protein quantification (1)
- Proton conductivity (1)
- Provenance studies (1)
- Prüfkammer (1)
- Prürfrichtlinie (1)
- QA/QC (1)
- Quality assurance (1)
- Quantum dot (1)
- REACH (1)
- RFA (1)
- Radon exhalation (1)
- Recovery rate (1)
- Recycling (1)
- Reduktionsprozess (1)
- Reference data (1)
- Reference nanoparticles (1)
- Reference procedures (1)
- Reference samples (1)
- Release kinetics (1)
- Research Data Infrastructure (1)
- Research Data Management (1)
- Research data management (1)
- Ringversuch (1)
- Robustness validation (1)
- Rround robin test (1)
- SARS (1)
- SAXS (1)
- SDS-PAGE (1)
- SMPS (1)
- SOP (1)
- Safety (1)
- Sample preparation (1)
- Schadgase (1)
- Schutzverglasung (1)
- Selective quantification (1)
- Self-assembled monolayer (SAM) (1)
- Self-assembled monolayers (SAM) (1)
- Semivolatile organic compounds (1)
- Sensor (1)
- Silver diffusion (1)
- Sintering (1)
- Small angle x-ray scattering (1)
- Solid phase (1)
- Solid-phase extraction (SPE) (1)
- Solvents (1)
- Spectroscopy (1)
- Spielzeug (1)
- Stained glasses (1)
- Standardarbeitsanweisungen (1)
- Subjective complaints (1)
- Surface chemistry (1)
- Sustainability (1)
- Synthesis (1)
- TEM (1)
- TXRF ambient air aerosol chemical analysis aerosol element composition (1)
- Tantal (1)
- Targeting, Nanoparticles (1)
- Test method (1)
- Thermal Desorption (1)
- Thermal Extraction (1)
- Thermal properties (1)
- Thermografie (1)
- Thermoplastic filaments (1)
- Transition metals (1)
- Transmission electron microscopy (1)
- Tyrosine (1)
- UV absorption (1)
- UV protection (1)
- Umweltmessung (1)
- Up-cycling (1)
- Uptake rate (1)
- VAMAS (1)
- VOC Emission (1)
- VOC emission (1)
- VOC transfer standards (1)
- VOC-Emission (1)
- Vitrine (1)
- Volatile organic compound (1)
- Volatile organic compounds (VOC) (1)
- WKI flask method (1)
- Weathering tests (1)
- Workflows (1)
- X-Ray analysis (1)
- XRF (1)
- ZIF (1)
- ZIF-8 (1)
- Zeolithe (1)
- Zinc oxide (1)
- natural ventilation (1)
- openBIS (1)
- pH (1)
- pH sensor (1)
- pHe (1)
- Äquivalenzdurchmesser (1)
Organisationseinheit der BAM
- 4.2 Material-Mikrobiom Wechselwirkungen (174) (entfernen)
Paper des Monats
- ja (3)
Indoor air quality is affected by the emission of volatile organic compounds (VOC) or the odour from building products. Odours can be measured by applying the standard ISO 16000-28:2020.
In the study presented here proposals for further technical development of the ISO method are presented. The sampling procedure and evaluation
method of the perceived intensity are investigated in particular because they have a major influence on reproducibility of measurement results.
Healthy and energy efficient buildings must be free from disturbing odours. Odour emissions from building materials can be measured with the well-known and accepted standard ISO 16000-28 “Indoor air – Part 28: Determination of odour emissions from building products using test chambers”. For commonly used emission test chambers the sample air is collected in containers (bags) and presented to a group of panel members for the purpose of evaluating the odour. A standard sets requirements for the on-demand presentation in detail. These include the validation procedure for container materials, pre-treatment of bags, details on storage of filled bags and how to carry out the measurements. However, although these measures are proven in practice, incorrect measurements are still possible. Also errors can occur due to a very complex measurement procedure. So, there is a great need for research into how the odour samples are presented.
The proposal planned to be presented will introduce a new development in sample provision by using an adapter which enables collection and provision of sample air without storage or transport of bags. The adapter is a sample container which is permanently positioned on the emission test chamber´s outlet and continuously filled with sample air flowing through it. The flow is briefly interrupted at the time when a sample is taken by a panel member for the test.
The size of the container is sufficient to provide enough sample air for evaluation by at least one panel member via a funnel. Since sampling and presentation are technically connected, it means you can almost do away with storage or transportation and thus it can be presented almost unchanged to the panelmembers. The aim is to reduce measurement errors in the odour samples provision process and the improvement of measurement reproducibility. The paper presents the construction of the adapter as well as the results of emission and odour tests carried out so far.
One criterion to evaluate the odour of a sample is perceived
intensity П which is evaluated with the aid of a comparative scale. The procedure is well accepted but also time consuming and extensive. The study should help simplify the testing procedure by asking the panel members to only indicate whether a sample is perceived as less to equally intense or of greater intensity in comparison to a given acetone concentration of 7 pi on the comparative scale. In Germany a value of 7 pi is required for products to be suitable for the indoor use. The results show that the simplified test is basically suitable.
Sintered bioactive glass scaffolds of defined shape and porosity, e.g. made via additive manufacturing, must provide sufficient bioactivity and sinterability. As higher bioactivity is often linked to high corrosion and crystallization tendency, a certain compromise between sintering ability and bioactivity is therefore required. Groh et al. developed a fluoride-containing bioactive glass (F3), which allows fiber drawing and shows a bioactivity well comparable to that of Bioglass®45S5.
To study whether and to what extent the sinterability of F3 glass powder is controlled by particle size, coarse and fine F3 glass powders (300-310µm and 0-32µm) were prepared by crushing, sieving and milling. Sintering, degassing and phase transformation during heating were studied with heating microscopy, vacuum hot extraction (VHE), DTA, XRD, and SEM.
For the coarse glass powder, sintering proceeds slowly and is limited by surface crystallization of primary Na2CaSi2O6 crystals. Although the crystallization onset of Na2CaSi2O6 is shifted to lower temperature, full densification is attained for the fine powder. This finding indicate that certain porosity might be tuned via particle size variation. Above 900°C, intensive foaming is evident for the fine powder. VHE studies revealed that carbon species are the main foaming source.
Equipping ZIF particles with a polyelectrolyte membrane provides functional groups at their interface, enabling further conjugations necessary for applications such as targeted drug delivery. Previous approaches to coat ZIF particles with polyelectrolytes led to surface corrosion of the template material. This work overcomes previous limitations by performing a Layer-by-Layer (LbL) polyelectrolyte coating onto ZIF-8 and ZIF-67 particles in nonaqueous environment. Using the 2-methylimidazolium salt of polystyrensulfonic acid instead of the acid itself and polyethyleneimine in methanol led to intact ZIF particles after polyelectrolyte coating. This was verified by electron microscopy. Further, zetapotential and atomic force microscopy measurements confirmed a continuous polyelectrolyte multilayer built up. The here reported adaption to the well-studied (LbL) polyelectrolyte selfassembly process provides a facile method to equip ZIF particles with a nanometer thin polyelectrolyte multilayer membrane.
In this work, we use a gas sensor system consisting of a commercially available gas sensor in temperature cycled operation. It is trained with an extensive gas profile for detection and quantification of hazardous volatile organic compounds (VOC) in the ppb range independent of a varying background of other, less harmful VOCs and inorganic interfering gases like humidity or hydrogen. This training was then validated using a different gas mixture generation apparatus at an independent lab providing analytical methods as reference. While the varying background impedes selective detection of benzene and naphthalene at the low concentrations supplied, both formaldehyde and total VOC can well be quantified, after calibration transfer, by models trained with data from one system and evaluated with data from the other system. The lowest achievable root mean squared errors of prediction were 49 ppb for formaldehyde (in a concentration range of 20–200 ppb) and 150 μg/m³ (in a concentration range of 25–450 μg/m³) for total VOC. The latter uncertainty improves to 13 μg/m³ with a more confined model range of 220–320 μg/m³. The data from the second lab indicate an interfering gas which cannot be detected analytically but strongly influences the sensor signal. This demonstrates the need to take into account all sensor relevant gases, like, e.g., hydrogen and carbon monoxide, in analytical reference measurements.
Fluorometric sensing is a versatile approach for trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them as superior active component for the preparation of optical sensing devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents, illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications.
In the interdisciplinary project presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable. The dyes presented follow a “turn-on” fluorescence schematic, which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing. Further steps in the project include the assembly of instruments for test-atmosphere generation, the referencing of the sensor system, development and implementation of an optical setup, and the testing of the prototype device under laboratory conditions and in the field.
In this presentation, we give an overview over the recent developments on this topic in our groups. Highlights are hydrogen sulfide sensitive, BODIPY based transition metal complexes, which allow for a sensitive as well as selective detection of the toxic gas. In addition, we present a novel class of highly substituted BODIPY derivatives – pocket-BODIPYs – which are of a synthetically high versatility and can readily be modified to create pockets in the periphery of the molecule of defined geometries. This is illustrated on the successful encapsulation of benzene by a pocket-BODIPY derivative, confirmed by X-ray crystallographic analysis as well as by further spectroscopic and analytical methods.
Dass Viren sich über Aerosolpartikel ausbreiten können, wurde bereits in vielen Studien gezeigt. Als Aerosol bezeichnet man ein Gemisch aus Luft mit darin verteilten festen oder flüssigen Partikeln. Ein Aerosol ist dabei immer dynamisch, da Partikel neugebildet, in oder mit der Luft transportiert und aus der Luft entfernt werden oder sich im luftgetragenen Zustand verändern. Zum Verständnis der Rolle von Aerosolpartikeln als Übertragungsweg von SARS-CoV-2 ist daher die Kenntnis der verschiedenen Prozesse in einem Aerosol von besonderer Bedeutung. Mit diesem Papier möchte die GAeF einen Beitrag dazu leisten, den momentan so häufig anzutreffenden Begriff „Aerosol“ sowie die relevanten Aerosolprozesse anschaulich darzustellen und zu erläutern. Dabei wird im Rahmen dieses Papiers nur auf die wesentlichen Grundlagen eingegangen.
Für ein tiefergehendes Verständnis der teilweise komplexen Prozesse sei auf die angeführte Sekundärliteratur verwiesen. Das Papier fasst eine Vielzahl von Studien zur Entstehung von virenbeladenen Aerosolpartikeln sowie deren Ausbreitung zusammen. Darauf basierend kann festgestellt werden, dass ausgeatmete Aerosolpartikel auch bei der Corona-Pandemie eine prominente Rolle bei der Verbreitung der Viren spielen. Abschließend geht dieses Papier auf mögliche Maßnahmen zur Verringerung der Ausbreitung von Aerosolpartikeln ein. Die diskutierten Maßnahmen orientieren sich an der derzeitigen öffentlichen Diskussion und beinhalten entsprechend die folgenden Punkte: Lüften, Luftreiniger, Lüftungsanlagen und Masken. Es werden Hinweise zum richtigen und sinnvollen Einsatz dieser Maßnahmen gegeben. Aerosolpartikel haben Größen zwischen ca. 0,001 und mehreren 100 Mikrometern (und nicht wie in vielen Publikationen derzeit definiert < 5μm) und verteilen sich mit Luftströmungen relativ schnell, auch über größere Distanzen. Größere Aerosolpartikel sinken – abhängig von ihrer Größe und Dichte – zu Boden; kleine Aerosolpartikel können hingegen sehr lange in der Luft verbleiben (s. Kapitel 3). Jeder Mensch stößt durch die Atmung sowie beim Sprechen, Husten und Niesen flüssige Aerosolpartikel unterschiedlicher Größen aus (s. Kapitel 4). Ist eine Person mit einem Virus, wie z. B. SARS-CoV-2, infiziert, so können diese Aerosolpartikel Viren enthalten, die in die Luft gelangen und von anderen Personen eingeatmet werden können. SARS-CoV-2 hat eine Größe von 0,06 bis 0,14 Mikrometer, die exhalierten flüssigen Aerosolpartikel sind hingegen größer. Die flüssigen Aerosolpartikel können aber je nach Umgebungsbedingungen durch Verdunstung schrumpfen (s. Kapitel 3.3). Für den Partikeltransport und die Partikelabscheidung ist dabei jeweils die aktuelle Partikelgröße relevant. Das höchste Infektionsrisiko besteht in geschlossenen Innenräumen, da sich hierin Aerosolpartikel anreichern können. Insbesondere hier sind entsprechend Maßnahmen zu treffen, die eine Reduktion der Aerosolpartikelkonzentration ermöglichen.
Vor dem Hintergrund der Aerosolwissenschaften ordnet die GAeF die aktuellen Maßnahmen zur Eindämmung der Pandemie wie folgt ein:
• Prinzipiell gilt: Keine Maßnahme kann für sich alleine funktionieren! Das Zusammenspiel der verschiedensten Maßnahmen ist nach derzeitigem Wissensstand der beste Weg zur Minimierung des Infektionsrisikos.
• Abstand halten ist wichtig, denn mit zunehmendem Abstand werden direkt ausgeatmete Viren verdünnt, und die Wahrscheinlichkeit sich anzustecken sinkt. Der vielfach vorgeschriebene Mindestabstand kann als Anhaltspunkt dienen, sollte aber insbesondere bei längeren Zusammenkünften und auch in Innenräumen mit verringerter Luftbewegung vergrößert und durch weitere Maßnahmen (s.u.) ergänzt werden.
• Masken helfen, einen Teil der exhalierten Partikel (und Viren) zu filtern. Dadurch sinkt die Konzentration der exhalierten Partikel (und Viren) in einem Raum und damit das Infektionsrisiko. Hierbei ist zu beachten, dass die ausgeatmeten Aerosolpartikel durch anhaftende Feuchtigkeit relativ groß sind und somit auch von einfachen Masken effizient zurückgehalten werden können. Da diese Partikel aber mit längerer Verweilzeit in der Raumluft schrumpfen, sind einfache Mund-Nasen-Bedeckungen für den Selbstschutz weniger effizient. Hierfür sind Atemschutzmasken erforderlich, die auch für feine Partikel eine hohe Abscheidung zeigen, z. B. der Klassen FFP2, N95 oder KN95. Diese sind sowohl für den Selbst- als auch den Fremdschutz effizient, sofern sie über kein Ausatemventil verfügen. Masken mit Ausatemventil dienen hingegen nur dem Selbstschutz und widersprechen daher dem Solidaritätskonzept, dass Mitmenschen durch kollektives Maskentragen geschützt werden.
• Gesichtsvisiere, die ohne zusätzliche Verwendung von Masken eingesetzt werden, sind hinsichtlich Aerosolpartikeln weitgehend nutzlos, da die Luft mit Partikeln (und Viren) ungefiltert um die Visiere herumströmt. Gesichtsvisiere werden im klinischen Alltag zusätzlich zu Masken getragen, um Tröpfcheninfektion über die Schleimhäute der Augen zu verhindern. Ebenfalls weitgehend unwirksam gegen die Aerosolverbreitung in Innenräumen sind mobile oder fest installierte Plexiglasbarrieren. Diese können nur kurzfristig die kleinräumige Ausbreitung eines Aerosols, z. B. im Kassenbereich eines Supermarkts, verhindern, bieten aber längerfristig keinen Schutz. Gesichtsvisiere und Plexiglasscheiben dienen im Wesentlichen als Spuck- und Spritzschutz gegenüber großen Tröpfchen.
• Im Freien finden so gut wie keine Infektionen durch Aerosolpartikel statt. Allerdings können Tröpfcheninfektionen auftreten, insbesondere in Menschenansammlungen, wenn Mindestabstände nicht eingehalten und/oder keine Masken getragen werden. In geschlossenen Räumen ist Lüften unerlässlich, um die ausgeatmete Luft in einem Raum durch frische Luft von draußen zu ersetzen. Häufiges Stoß- und Querlüften sind dabei vergleichbar effektiv wie dauernd das Fenster vollständig geöffnet zu lassen. Aus energetischer Sicht ist Stoß- oder Querlüften insbesondere im Winter allerdings effizienter. CO2-Monitore können bei der Überwachung der Luftqualität in Innenräumen helfen. Sie zeigen an, wann gelüftet werden sollte und wann die Luft in einem Raum während des Lüftens ausreichend gewechselt ist. Sie können jedoch nur als Indikator verwendet werden und verhindern selbst bei Einhaltung der vorgeschlagenen CO2-Grenzkonzentrationen keine direkte Infektion durch unmittelbar benachbarte Personen.
• Luftreiniger können einen sinnvollen Beitrag leisten, um die Partikel- und Virenkonzentration in einem Raum zu reduzieren. Bei der Beschaffung von Luftreinigern muss darauf geachtet werden, dass diese für den betrachteten Raum und die betrachtete Anwendung ausreichend dimensioniert sind, um die Partikel- und Virenlast signifikant zu verringern. Dem Luftdurchsatz des Gerätes kommt dabei eine größere Bedeutung zu, als der reinen Effizienz des Filters. Aus energetischen und Kostenerwägungen kann die Verwendung hocheffizienter Filter sogar kontraproduktiv sein. Fest verbaute Lüftungsanlagen können ebenso sinnvoll sein, sofern sie die Luft filtern, um die Partikel- und Virenlast in einem Raum zu verringern. Hierbei ist es zur Vermeidung von Infektionen sinnvoll, diese möglichst mit 100 % Frischluft zu betreiben.
Aus Sicht der Gesellschaft für Aerosolforschung besteht erheblicher Forschungsbedarf insbesondere an den interdisziplinären Grenzen zu Forschungsfeldern der Epidemiologie, Infektiologie, Virologie, Lüftungstechnik und Strömungsmechanik. Die Durchführung gezielter Studien sollte kurzfristig mit speziellen Förder- und Forschungsprogrammen ermöglicht werden. Dieses Papier wurde von Mitgliedern der Gesellschaft für Aerosolforschung verfasst und wird von einer Vielzahl internationaler Aerosolexperten unterstützt (s. Kapitel 8). Neben der vorliegenden Version existiert auch eine englischsprachige Übersetzung (siehe www.info.gaef.de). Sämtliche Abbildungen in diesem Papier stehen unter folgendem Link zum kostenlosen Download bereit: https://www.info.gaef.de/positionspapier. Bei jeder Verwendung ist „Gesellschaft für Aerosolforschung e. V.“ als Quelle zu nennen.
Many studies have already shown that viruses can spread via aerosol particles. An aerosol is a mixture of air with solid or liquid particles dispersed in it. To understand the role of aerosol particles as a transmission path of SARS-CoV-2, knowledge of the different processes in an Aerosol is therefore of particular importance. With this paper, GAeF would like to contribute to a better understanding of the term “aerosol” and the relevant aerosol processes. In the context of this paper only the essential basics will be discussed. For a deeper understanding of the partly complex processes, please refer to the literature mentioned at the end of the paper.
The paper summarises a large number of studies on the formation of virus-laden aerosol particles and their spread. Based on this, it can be concluded that exhaled aerosol particles may play a prominent role in the spread of viruses in the corona pandemic. Finally, this paper discusses possible measures to reduce the spread of aerosol particles. The measures discussed are based on the current public debate including ventilation, air purifiers, HVAC systems and masks. Advice is given on the correct and sensible use of these measures.
An aerosol is always dynamic, as particles are newly formed, transported in or with the air, removed from the air or change in the airborne state. Aerosol particles have sizes between approx. 0.001 and several 100 micrometres (and not < 5 μm as currently defined in many publications) and spread relatively quickly with air currents, even over longer distances. Larger aerosol particles sink to the ground, depending on their size and density, while small aerosol particles can remain in the air for a very long time (see Section 3). Every person emits liquid aerosol particles of various sizes through breathing and when speaking, coughing and sneezing (see Section 4). If a person is infected with a virus, such as SARS-CoV-2, these aerosol particles can contain viruses that can be released into the air and inhaled by other people. SARS-CoV-2 has a size of 0.06 to 0.14 micrometres, but the exhaled liquid aerosol particles are larger. The liquid aerosol particles can shrink by evaporation, depending on the ambient conditions (see Section 3.3). Particle size is relevant for particle transport and particle separation. The highest risk of infection exists in closed indoor spaces, as aerosol particles can accumulate there.
Here in particular, appropriate measures must be taken to reduce the concentration of aerosol particles (see Section 5).
Against the background of aerosol science, the GAeF classifies the current measures to contain the pandemic as follows:
• In principle, no measure can work on its own! According to the current state of knowledge, the interaction of the most varied measures is the best way to minimise the risk of infection.
• Keeping distance is important, because with increasing distance, directly exhaled viruses are diluted and the probability of infection decreases. The often prescribed minimum distance can be used as a guide, but it should be increased and supplemented by other measures (see below), especially for longer meetings and also indoors with reduced air movement.
• Masks help to filter some of the exhaled particles (and viruses). This reduces the concentration of exhaled particles (and viruses) in a room and thus the risk of infection. It should be noted here that the exhaled aerosol particles are relatively large due to adhering moisture and can therefore also be efficiently retained by simple masks. However, since these particles shrink with longer dwell time in the room air, simple mouth-nose masks are less efficient for self-protection. Respiratory masks are required for this purpose, which show a high degree of separation even for fine particles, e.g. of classes FFP2, N95 or KN95. These are efficient for both self-protection and protection of others unless they have an exhalation valve. Masks with an exhalation valve, on the other hand, are only for self-protection and therefore contradict the solidarity concept that fellow human beings are protected by collective mask wearing. Face shields which are used without additional masks are largely useless with regard t• aerosol particles, as the air with particles (and viruses) flows unfiltered around the shields. In everyday clinical practice, facial shields are worn in addition to masks to prevent droplet infection via the mucous membranes of the eyes. Mobile or permanently installed Plexiglas barriers are also largely ineffective against the spread of aerosols indoors. These can only prevent the smallscale spread of an aerosol in the short term, e.g. in the checkout area of a supermarket, but offer no protection in the longer term. Face shields and Plexiglas panels essentially serve as spit and splash protection against large droplets.
• Outdoors, there are practically no infections caused by aerosol transmission. However, droplet infections can still occur, especially in crowds, if minimum distances are not observed and/or masks are not worn. In closed rooms, ventilation is essential to replace the exhaled air in a room with fresh air from outside. Frequent airing and cross-ventilation is just as effective as leaving the window open all the time. From an energy point of view, however, it is more efficient to ventilate the room, especially in winter. CO2 monitors can help to monitor indoor air quality. They indicate when it is necessary to ventilate and when the air in a room has been sufficiently changed during ventilation. However, they can only be used as an indicator and even if the proposed CO2 limit concentrations are met, they do not prevent direct infection by people in the immediate vicinity.
• Air purifiers can make a useful contribution to reducing the concentration of particles and viruses in a room. When procuring air purifiers, care must be taken to ensure that they are adequately dimensioned for the room and application in question in order to significantly reduce the particle and virus load. The air throughput of the unit is more important than the pure efficiency of the filter. For energy and cost reasons, the use of highly efficient filters can even be counterproductive. Permanently installed ventilation systems can also be useful, provided they filter the air to reduce the particle and virus load in a room. To avoid infections, it is advisable to operate them with 100 % fresh air if possible.
From the point of view of the Gesellschaft für Aerosolforschung, there is a considerable need for research, especially at the interdisciplinary borders to research fields of epidemiology, infectiology, virology, ventilation technology and fluid mechanics. The implementation of targeted studies should be made possible at short notice with special funding and research programmes.
This paper was written originally in German by members of the Gesellschaft für Aerosolforschung and is supported by a large number of international aerosol experts. Both the English and German version as well as all images in the paper are available for free download at the following link: https://www.info.gaef.de/positionspapier. The “Gesellschaft für Aerosolforschung e. V.” must be named as the source, whenever an image is used.