4 Material und Umwelt
Filtern
Dokumenttyp
- Posterpräsentation (14) (entfernen)
Referierte Publikation
- nein (14)
Schlagworte
- Leaching (3)
- PFAS (3)
- Combustion ion chromatography (2)
- Per- and Polyfluoroalkyl substances (PFAS) (2)
- Adsorbable organically bound fluorine (AOF) (1)
- Antimony (1)
- Artificial ageing (1)
- Bottom ash (1)
- Combustion Ion Chromatography (1)
- Combustion ion chromatography (CIC) (1)
- Comsumer good samples (1)
- Construction products (1)
- DSLT (1)
- Ersatzbaustoffe (1)
- Extractable organically bound fluorine (EOF) (1)
- Flame-retardant (1)
- Geosynthetics (1)
- Ground water (1)
- Headspace GC-MS (1)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (1)
- Lysimeter (1)
- Micro plastic (1)
- Mikroplastik (1)
- Organo fluorine analysis (1)
- PAK (1)
- Passive sampling (1)
- Per- and polyfluorinated alkyl substances (PFASs) (1)
- Perfluorocarboxylic acid (PFCA) (1)
- Phosphorus (1)
- Plant-availability (1)
- Polyfluorinated alcohol (PFOH) (1)
- Remediation (1)
- Rostasche (1)
- SPE extraction (1)
- Schwermetalle (1)
- Sewage extraction (1)
- Sewage sludge (1)
- Soil (1)
- Soil extraction (1)
- Solubility (1)
- Sorption (1)
- Sum parameter analyis (1)
- Surfacewaters (1)
- TED-GC/MS (1)
- Ultrashort PFAS (1)
- Wastewater (1)
- XPS (1)
- XRF (1)
Organisationseinheit der BAM
- 4.3 Schadstofftransfer und Umwelttechnologien (14) (entfernen)
Brominated flame retardants have widely been used for more than 50 years and have been frequently detected in environmental samples as surface water and fish. Leaching from construction products was identified as one possible source. The use of substances as e.g. hexabromocyclododecane (HBCCD) was restricted recently due to increasing concern about negative impacts on the environment and human health caused by the persistent, bio accumulative and toxic properties. New polymeric brominated flame retardants have been developed to replace HBCCD in expanded polystyrene (XPS), which is used for insulation of buildings. It is assumed that the release from the polymer is much smaller in comparison to release of small molecules as HBCCD. The release from the polymer may include monomers or small fragments of different size. Thus, a sum parameter is needed. According to Schlummer et al. it is possible to detect brominated molecules using X-ray fluorescence spectroscopy by determination of brome content in XPS extracts. As only small brominated compounds can be extracted it also allows for the differentiation between the two classes of compounds. This method was applied to verify the presence of different kinds of flame retardants in XPS samples and to evaluate the leaching behavior.
Abstract: Since it is unknown for many applications, which PFASs are used and how they enter the environment, target analysis-based methods reach their limits. The two most frequently used sum parameters are the adsorbable organically bound fluorine (AOF) and the extractable organically bound fluorine (EOF). Both can be quantified using either combustion ion chromatography (CIC) or high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). Here we provide an insight on the advantageous and disadvantageous of both sum parameters and both detection methods. Our study is based on the analysis of surface water samples. Next to total fluorine (TF) analysis, AOF and EOF were determined as well as CIC and HR-CS-GFMAS are compared and results are comparatively discussed. Fluorine mass balancing revealed that, the AOF/TF proportion was higher than the EOF/TF proportion. The AOF made up 0.14–0.81% of TF and the EOF 0.04–0.28% of TF. Although, organically bound fluorine represents only a small portion of TF, PFASs are of worldwide concern, because of their extreme persistence and their bioaccumulation potential. The EOF-HR-CS-GFMAS method turned out to be more precise and sensitive than the AOF-CIC method and is a promising tool for future monitoring studies/routine analysis of PFASs in the environment.
Per- and polyfluoroalkyl substances (PFAS) were classified as a group of highly concerning chemicals over the last decades. Because of the high persistence of PFAS, their previous use led to contamination of the environment and human population. Due to ongoing use and incomplete remediation or destruction methods, the PFAS background in the environment is growing continuously.
The presence of ultrashort PFAS (with ≤3 carbon atoms) in the environment is often overlooked despite their contributions to PFAS levels. These compounds may directly contaminate the environment and arise from degradation of polyfluorinated compounds as well as incomplete PFAS destruction in certain industrial processes. Nonetheless, few approaches for targeted analysis of ultrashort PFASs have been developed, except for trifluoroacetic acid (TFA). Beside liquid (LC-MS/MS), supercritical fluid (SFC-MS/MS), and ion chromatography (IC-MS)-based systems, gas chromatography coupled with mass spectrometry (GC-MS) is a promising method for detection and quantification of ultrashort PFAS.
The goal of this study was to develop a simple headspace GC-MS method for the quantification of ultrashort perfluorocarboxylic acids (PFCAs) and polyfluorinated alcohols (PFOHs) in water samples. In contrast to PFOHs, functionalization of PFCAs was required for quantification. This was done by esterification with methanol at 80 °C, which can be carried out directly in the headspace GC-MS system.
Moreover, several parameters were optimized to achieve a low limit of quantification (LOQ) for the analytes used: i) The ratio of the aqueous solution, methanol, and available gas phase within the analysis vessel, ii) the concentration of additional acid in esterification mixtures of PFCAs, iii) shaking frequency and iv) shaking time before analysis. After optimizing the procedure, we were able to quantify ultrashort PFCAs and PFOHs. Thus, our developed headspace GC-MS method has the potential to be used as an alternative target analysis for ultrashort-chain PFCAs and PFOHs in various water samples (groundwater, wastewater).
Aschen und Schlacken aus der thermischen Abfallbehandlung enthalten eine Vielzahl von Schwermetallverbindungen. Für Antimon, Chrom, Kupfer, Molybdän und Vanadium werden in der neuen Ersatzbaustoffverordnung Eluatgrenzwerte für die Verwertung festgelegt. Aschen und Schlacken werden aus der Abfallverbrennungsanlage nass ausgetragen und vor einer Verwertung in der Regel mehrere Wochen gelagert. Dabei finden hydraulische Reaktionen statt und enthaltenes CaO wird zu einem Großteil in Calciumcarbonat umgewandelt. Während wässrige Eluate von frischen Aschen pH-Werte von 12 und höher aufweisen, sind die Eluate nach einigen Wochen weniger stark alkalisch. Die gemessenen Schwermetallkonzentrationen sind daher dann auch deutlich niedriger, mit Ausnahme von Antimon (Sb) und Vanadium (V). Hier steigen die Konzentration mit der Lagerungsdauer. Grund sind sinkende Konzentrationen von Ca-Ionen, die sonst zu einer Ausfällung von Antimonaten und Vanadaten führen. Zu hohe Eluatwerte von Sb und V können durch Sorption an Eisenoxidverbindungen gemindert werden. Als besonders wirkungsvoll hat sich Schwertmannit (Eisen-Oxyhydroxysulfat) erwiesen. Es entsteht durch Oxidation von pyrithaltigem Material durch Mikroorganismen und wird deshalb in Gebieten gefunden, in denen Braunkohle abgebaut wurde, z.B. in der Lausitz. Weitere untersuchte Eisenoxidverbindungen waren Hämatit und Schlämme aus der Abtrennung von Eisen und Mangan in Wasserwerken.