Fused filament fabrication (FFF) on desktop 3D printers is a material extrusion-based technique often used by educational institutions, small enterprises and private households. Polymeric filaments are melted and extruded through a heated nozzle to form a 3D object in layers. The extrusion temperature is therefore a key parameter for a successful print job, but also one of the main driving factors for the emission of harmful air pollutants, namely ultrafine particles and volatile organic gases, which are formed by thermal stress on the polymeric feedstock. The awareness of potential health risks has increased the number of emission studies in the past years. However, the multiplicity of study designs makes an objective comparison of emission data challenging because printer hardware factors such as the actual extruder temperature (TE) and also feedstockspecific emissions are not considered. We assume that across the market of commercial low- and mid-price FFF printers substantial deviations between actual and set extruder temperatures exist, which have a strong effect on the emissions and hence may bias the findings of exposure studies. In our last publication, we presented a standardized feedstock-specific emission test method and showed that for each investigated feedstock an increase in actual extruder temperature was accompanied by an increase in particle emissions (Tang and Seeger, 2022). Therefore, any systematic discrepancy between set and actual extruder temperature matters. In this study, we used a thermocouple and an infrared camera to measure the actual extruder temperatures at different heights. We found significant under- and overestimation of the actual extruder temperatures by the respective set temperatures in three commercial printers. This caused a broad variation of the measured total numbers of emitted particles (TP), even when the same feedstock was operated. For the determination of TP, we followed the DE-UZ 219 test guideline. In a second round we repeated the tests with all printers adjusted to exactly the same extruder temperatures, i.e., to TE=230°C for ABS and TE=210°C for PLA. All measurements were conducted in a 1 m³ emission test chamber. Particle emissions in the size range between 4 nm and 20 μm were detected. Printing on three different printer models without temperature adjustment resulted for each of the investigated feedstocks in a variation in TP of around two orders of magnitude. After temperature adjustment, this was substantially reduced to approx. one order of magnitude and hence minimizes the bias of printer hardware on the emissions. Our findings suggest that adjustment of the extruder temperature should be mandatory in emission testing standards. It also poses a more accurate benchmark and provides more reliable emission data for evaluation of indoor air quality or for health risk assessments. In addition, a proper temperature setting is in the interest of the user. Some commercial FFF printers may have a higher actual extruder temperature than displayed and unintended overheating may not only impair the print quality but may cause unnecessarily increased exposure to particle emissions.
The current state of preservation of the DSS results from the synergetic effect of various factors such as great age, post-discovery treatments, poor storage conditions, environmental influences and exhibitions. With rare exceptions, neither the initial state nor a list of the treatments performed on each DSS fragment is known. Reconstruction of the individual fragment history will have to rely upon advanced analytical techniques to identify the treatments and their effects.
Management of the scrolls may be divided roughly into three periods: a) the scholarly archiving period, from 1948 to the mid-1960s; b) first attempts at conservation, from the mid-1960s to late-1980s; c) Israel Antiquities Authority Scrolls Lab, from 1991 onwards.
In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. Different VOC combinations may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use materials proven to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability and metrological traceability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable reference materials. The emission test chamber procedure according to EN 16516 comprises several steps from sample preparation to sampling of test chamber air and chromatographic analysis. Quality assurance and quality control (QA/QC) must therefore be ensured. Currently, there is a lack of suitable reference products containing components relevant for the health-related evaluation of building products.
The EU-funded EMPIR project 20NRM04 MetrIAQ (Metrology for the determination of emissions of dangerous substances from building materials into indoor air) aims to develop 1) gaseous primary reference materials (gPRM), which are used for the certification of gaseous (certified) reference materials (gCRM) and 2) emission reference materials (ERM).
Most commercial gas standards of indoor-relevant compounds are not certified due to the lack of primary reference materials to which the project aims to contribute. The gPRM under development is a gas-phase standard containing trace levels of VOCs in nitrogen or air from the check standard according to EN 16516 (n-hexane, methyl isobutyl ketone, toluene, butyl acetate, cyclohexanone, o-xylene, phenol, 1,3,5-trimethylbenzene) with a target uncertainty of 5 %. The gPRM can be sampled into sorbent tubes to obtain transfer standards in the form of gCRM.
The well characterised ERM represents a sample of a test specimen, e.g. building material, that is loaded into the emission test chamber for a period of several days and is used to evaluate the whole emission test chamber procedure. It shall have a reproducible and temporally constant compound release of less than 10 % variability over 14 days. Different approaches for retarded VOC release, such as the encapsulation of pure compounds and the impregnation of porous materials, are being tested to reach this aim. Furthermore, the design of the ERM is accompanied by the development of a numerical model for the prediction of the emissions for each of the target VOCs. The current progress of the work on both materials will be presented.
Interest in the type of skin used in scriptural materials and preparation methods increased from the nineteenth into the twentieth century. This was due partly to the number of newly discovered fragments and to the invention of new instruments and scientific procedures to identify animal skins and produce qualitative means to demonstrate specific preparation reagents and techniques. The invention of various means of analyzing the DNA of organic materials brought about a revolution in archaeology and in conservation. Difficulties in overcoming contamination of archaeological samples resulted in a number of controversies but also produced advances and improvement in the techniques of ancient DNA analysis and interpretation of results.
Physico-chemical analyses of writing materials offer insight into various questions associated with historical, cultural, and conservational aspects of manuscript studies. The catalogue of questions that can be addressed with these methods includes authenticity, dating, the attribution of various parts of the text to different scribes and the relation between the primary and secondary texts. Similarly, preservation of the manuscripts requires knowledge of the composition of the original materials versus old repairs, identification of damage, as well as recognition of natural aging and degradation processes. The material sciences can contribute data about the chemical compositions of the writing materials, elucidation of the techniques of their production and the absolute age of organic components, as well as characterization of corrosion effects, evaluation of conservation treatment, and monitoring of the preservation state.
Ancient Inks
(2023)
In the last decade scientists and scholars have accumulated more knowledge on black ink used for writing in Antiquity and the early Middle Ages.
Ready availability of non-destructive testing instruments employed in interdisciplinary projects on historic manuscripts have made it possible to determine the composition of ink and to compare it with the extant records.
The ink analysis protocol developed through cooperation between the Bundesanstalt für Materialforschung und -prüfung in Berlin and the Centre for the Study of Manuscript Cultures at the University of Hamburg involves the use of imaging techniques for ink screening, followed by spectroscopic analysis. In our presentation, we will begin by briefly reviewing the history of writing inks and discussing the three main categories: carbon-based inks, plant, and iron-gall inks. We will address their chronology, precursors, and mixed forms, as well as the features that allow for their identification. Then, we will present the techniques we use in ink analysis, whereby we would like to highlight the limitations, advantages, and disadvantages of each approach. Finally, we will discuss the new mass-spectrometric method based on micro-sampling and using atmospheric solid analysis probe (ASAP).
Colours on East Asian Maps
(2023)
Maps and colours have a close connection. Drawn or printed in black on white, subsequently added colours enhance maps with additional information. Colours were not just there to improve maps aesthetically, but they regulated how they were read and thus reinforced their meanings, significances and ideas. Colour is an important key to a more precise understanding of the map’s purposes and uses; moreover, colours are also an important aspect of a map’s materiality. The material scientific analysis makes it possible to find out more about the making of colours and the process of colouring maps. By skillfully deploying colours, map colourists were able to create mimetic representations of nature or codify information in an abstract form. The use of colours involved many considerations as to the materials. ‘Reading’ colours in this way gives a glimpse into the social lives of mapmakers as well as map users and reveals the complexity of the historical and social context in which maps were produced and how the maps were actually made. Within the scope of the three-year joint research project Coloured Maps (2018–2021), we undertook an in-depth and systematic study of hand-drawn and hand-coloured maps from East Asia in the Museum am Rothenbaum (MARKK) in Hamburg and produced between the seventeenth and twentieth centuries.
With a multi-perspective approach and transdisciplinary methods (humanities and the sciences), we were able to pool and compare the research results from different fields of research on Asian maps. The aim of this publication is to provide a first general overview of the subject of colours on maps in East Asia in the period from the seventeenth to the early twentieth century and to stimulate further research on the topic.
Round robin tests of odour and VOC emissions from building products – What have we learned so far?
(2023)
Emission testing of volatile organic compounds (VOC) and odour from materials and products is commonly based on emission test chamber measurements. These measurements are often the basis of mandatory or voluntary labelling procedures. To ensure the comparability of results from different testing laboratories their performance must be verified. For this purpose, round robin tests (RRTs) are conducted. Bundesanstalt für Materialforschung und - prüfung (BAM) offers such a RRT every two years using well characterised test materials with defined VOC emissions. In addition to the VOC quantification, the evaluation of odour is also implemented in the round robin tests. At the beginning, only perceived intensity (PI) was tested but over the years also the acceptance evaluation was considered. In principle, the results of PI and acceptance evaluation are comparable. The advantage of PI is the lower number of panel members necessary for one evaluation.
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test every two years using well-characterised test materials (one sealant, one furniture board and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 41 VOCs were included of which 37 gave test chamber air concentrations between 10 and 98 µg/m³. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Four compounds had higher concentrations between 250 and 1105 µg/m³. The relative standard deviations (RSD) of BAM proficiency tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 23% in 2021. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%.